Tender For Provision Of Deficient Lay Apart Store In Front Of Technical Building For Storage Of Aircraft Tyres, Sonobuoys And Various Store Of Aircraft Sue To Survey At Inas 316 At installation Hansa. (Tender Id No. 2026_Mes_781601_1)
Tender Overview
Project Description
Tender for Provision Of Deficient Lay Apart Store In Front Of Technical Building For Storage Of Aircraft Tyres, Sonobuoys And Various Store Of Aircraft Sue To Survey At Inas 316 At installation Hansa. (Tender Id No. 2026_Mes_781601_1)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-Aug-2026 | Revised Tender Pages | Other | 19-Aug-2026 |
| 2 | 04-Aug-2026 | Revised BOQ | BOQ | 19-Aug-2026 |
| 3 | 19-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard /dense soil |
| 2 | Excavation in trenches n,exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in hard/dense soil. |
| 3 | M&L PCC 1:4:8 type D2(using 40mm graded aggregate)as in foundation filling and mass concrete etc. |
| 4 | M&L for re-inforced cement concrete 1:2:4 type B-1 (20mm graded aggregate) as in footings, including attached plaster and buttresses etc complete. |
| 5 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete. |
| 6 | M&L for re-inforced cement concrete Nominal mix 1:2:4 type B-1(20mm graded aggregate) as in slab supported on wall, beams, plinth beams,Chajjas, roofs, landing, etc comp. |
| 7 | M&L for RCC (Nominal Mix ) type B1, 1:2:4 (20mm graded aggregate) in columns, pillars, post and struts |
| 8 | M&L for MS TMT bars 10mm dia and over, cut to lenth, bend to shape required, including cranking, bending, sprially for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 9 | M&L for MS TMT bars 5 mm dia and over, upto and including 10 mm dia in stirrups, spaces and binders. |
| 10 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete. |
| 11 | Formwork to soffits of suspended slab such as roof slab, floor slab etc |
| 12 | Fomwork to sides and soffits or arches |
| 13 | M&L for Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid seperately. |
| 14 | M&L for rendering 10mm in CM (1:6) over concrete wall surfaces finished even and smooth without using extra cement. |
| 15 | M&L for prepration on newly plaster surface of walls and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over treated surfaces |
| 16 | M&L for preparation of newly plastered surfaces of walls and applying two coat of distemper over a coat of primer and 3mm thick wall care puttycomplete all as specified and directed. |
| 17 | M&L hard core of gauge n.exc 63mm, deposited, spread and levelled in layers nexc 15 cm thick, watered and rammed to a true surface. |
| 18 | Returning/filling in including spreading, levelling, watering and well remming in hard/dense soil. |
| 19 | Removing excavated material n.exc 50m and depositing where directed at a level n exc 1.5m above the starting point. |
| 20 | M&L for 100 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as cement concrete in Sub-base floors, and pavings finishing cement concrete surface even and smooth without using extra cement |
| 21 | M&L for 25 mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in floorings, as in sub base of floor tiles in ground floor.complete all as specified |
| 22 | M&L for 15 mm thick screed bed in CM 1:4 for laying floor tiles . |
| 23 | M&L machine cut Kota stone slab 18-20 mm as in flooring etc laid over cement screed bed jointed with grey cement slurry mixed with pigment to match the shade the slab including rubbing and polishing complete. |
| 24 | M&L machine cut Kota stone slab 18-20 mm as in riser of steps,skirting ,dado and window cill etc laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade Including baking coat 10mm thick CM (1:4) and rubbing and polishing complete. |
| 25 | S&F in steelrolling shutters with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, crected in position as indicated, complete: gear operated type with bevel gear box and crank handle, thickness of lath 1.25 mm |
| 26 | S&F ball bearing for rolling shutters |
| 27 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi hamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) (A) Area not exceeding 2.00 sqm each |
| 28 | Providing and fixing factory made uPVC white colour fixed window made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame 60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose.) (A) Area not exceeding 1.00 sqm each |
| 29 | S &F Aluminium powder coated grill model / design no DG 104 ( 10 mm thick ) with DL-102 frame all as specified and as directed. Make: Decogrill or equivalent as approved by GE. |
| 30 | S&F 4mm thick sheetglass ordinary quality exceeding 0.5 sqm each pane |
| 31 | Providing 10mm thick plaster in CM (1:3) mixed with 3% integral water proofing compound over roof top surface finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid seperately |
| 32 | M&L for rendering 5 mm in CM (1:3) over concrete ceilling surfaces finished even and smooth without using extra cement. |
| 33 | M&L for Preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over alkaliresistant priming coat on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling. |
| 34 | M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection surface finished even and smooth using with extra cement |
| 35 | M&L Preparing new surfaces of iron and steel and applying one coat of redoxide zinc chrome primer and two coats of synthetic enamel paint over 10 cm width or girth comp. |
| 36 | M&L Chequered cement tiles 20cmx20cmx25cm thick, set, jointed and pointed in neat cement slurry in floor with grey cement and pigmen.t |
| 37 | M&L for Providing, cement concrete type B1 (1:2:4) using 20 mm graded aggregate in mud stops,copings, kneelers,apex stons, bed plate,etc rounded or chamfered on edges |
| 38 | M&L for Applying evenly a priming/tack coat with bituminous primer at 5 kg per 10 sq metre complete all as specified and directed |
| 39 | M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application completed all as specified. |
| 40 | Supply only water proofing compound |
| 41 | M & L for Point wiring with 1.5 sqmm (nominal area ) PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with stranded copper conductor in and incl stove enamelled steel concealed conduit (medium grade) and conduit accessories along with continuous earth wire 1.5 sqmm PVC insulated and unsheathed single core FRLS cable 1100 volts grade stranded copper conductor and connected to common earth dully, with 1.6 mm thick cadmium plated sunk MS pressed steel terminal box for one flame proof light/fan point controlled by one flame proof swicth. |
| 42 | M & L for Point wiring with 2.5 sqmm (nominal area ) PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with stranded copper conductor in and incl stove enamelled steel concealed conduit (medium grade) and conduit accessories along with continuous earth wire 2.5 sqmm PVC insulated and unsheathed single core FRLS cable 1100 volts grade stranded copper conductor and connected to common earth dully, with 1.6 mm thick cadmium plated sunk MS pressed steel terminal box for one flame proof light point controlled by one flame proof swicth. |
| 43 | M & L for Cutting chases, pinning in, making good to facings where required in stone concrete block or slab walls and pointing in cement mortar 1:3 to ends or edges of landings, steps, sunsheds, shelves, lintels etc and cutting chases for reqd size concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete as specified & directed |
| 44 | S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as specified. |
| 45 | S & F Flame proof exhaust fans AC single phase 230/240 V of size 305 mm sweep including necessary wall opening and fixing arrangement all as specified. |
| 46 | S & F Flame proof Louvers suitable for 305 mm exhaust fan all as specified. |
| 47 | S & F Flame Proof T /L fittings 4' Long 20 Watt single LED in aluminium alloy LM6 with wire guard |
| 48 | S & F Flame Proof three Phase and neutral plug, switch and socket 16 Amps capacity |
| 49 | Supply and fix single point air termination alluminium rod, 12mm dia, 300mm long including provision of mounting on upto 1 mtr length GI pipe, nuts bolts, washers, rigid fixed on top roof height and insulated from base complete all as specified and directed by Engr-in-charge. |
| 50 | Supply and fix aluminium strip 25mm x 3 mm complete with saddles and fixing screws for fitting the strip |
| 51 | M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed. |
| 52 | M & L for test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled and scrwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw complete all as specified and directed by Engr-in-charge. |
| 53 | Supply and fix tubes light grade with all fittings 40 mm dia fixed on the roof for Air termination |
| 54 | M&ll for PCC 1:3:6 Type C-I using 20 mm gradaed agrgate for PCC of size 0.15m x 0.15m x 0.15m cube with MS ferule for maounting GI pipe 40 mm Dia |
| 55 | Excavation in trenches by cutting of road crossing/PCC hard standing or hard soil, for laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. |
| 56 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed by Engr-in-charge. |
| 57 | Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed by Engr-in-charge. |
| 58 | Supply and lay Double walled corrugated pipe (DWC ) confirming to IS 14930 heavy duty 63/50 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed. |
| 59 | Supply and Laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 50 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified and directed by Engr-in-charge. |
| 60 | S&F in repairs MCB DB TPN 4 way DB 230 V, IP-54 with 200 A rated bus bar double door type complete all as specified and as directed. |
| 61 | S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 62 | S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 63 | M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge. |
| 64 | Supply and install high wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of 2 Ton capacity |
| 65 | M & L for FRLS sub main wiring with two runs of single core PVC insulated unsheathed 1100V grade multistranded copper conductor cable 4 Sqmm size incl suitable size in steel conduit concealed conduit 20 mm dia medium grade ISI marked including fittings and accessories incl one run 4 Sqmm PVC insulated unsheathed copper conductor cable as earth wire complete all as specified. |
| 66 | S&F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified. |
| 67 | Supply and install voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender