Tender For Provn Of Work Services For Induction Of Ad System At Air Force Station Barnala
Tender Value
6.56 Crore
Estimated cost
Bid Submission
03 Sep 2026
27 days left
EMD
6.53 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ludhiana → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Work Services For Induction Of Ad System At Air Force Station Barnala
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. |
| 2 | Provn of sub station building in permanent specifications complete all as specified and shown on drawings. |
| 3 | Construction of parking shed for vehicles complete all as specified and as shown on drawings. |
| 4 | NOTE: Schedule ‘A’ Part II to XVI under Ser No 2.01 to 2.08 are Prepriced by MES. |
| 5 | Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part II |
| 6 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part III |
| 7 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION SUPPLY\\" as listed in Schedule ‘A’ Part IV |
| 8 | Lump sum price worked out by the Contractor for “ROAD AND PATH WORK\\" as listed in Schedule ‘A’ Part V |
| 9 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’ Part VI |
| 10 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY WORK” as listed in Schedule ‘A’ Part VII |
| 11 | Lump sum price worked out by the Contractor for “STREET LIGHT WORK” as listed in Schedule ‘A’ Part VIII |
| 12 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY WORK\\" as listed in Schedule ‘A’ Part IX |
| 13 | SCHEDULE `A' PART - X MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. |
| 14 | \\"INTERNAL WATER SUPPLY\\" |
| 15 | S&F for chromium plated stop valve, two way 15mm bore, cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr in Charge. |
| 16 | \\"INTERNAL ELECTRIC SUPPLY\\" |
| 17 | S&F light fitting with building security light fitting with LED TYPE 35 watt optic lenses with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 32 mm bore “light grade” brackets 1.5 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge |
| 18 | \\"EXTERNAL WATER SUPPLY\\" |
| 19 | Supply and fixing 40 mm bore metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, and earthwork in any type of soil or breaking/cutting into road/sides/cement concrete, etc. and making good the disturbed surfaces as per existing condition, complete all as specified and directed. |
| 20 | Supply and fixing 25 mm bore metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, and earthwork in any type of soil or breaking/cutting into road/sides/cement concrete, etc. and making good the disturbed surfaces as per existing condition, complete all as specified and directed. |
| 21 | M&L masonary valve pit of size 450 x 450 x 600 (internal size) in PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation, brick wall with sub class `B’ bricks built in CM 1:6 PCC 1:2:4 type B1 using 20mm graded stone aggregate for coping rendering in CM (1:4), 15mm thick including provision of MS sheet cover 2mm thick fixed to MS angle frame made out of 50x50x6mm thick with 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surfaces and locking arrangements including dismantling old one with necessary excavation and earth work in any type of soil all as specified and shown on drawing complete, all as specified and directed by Engineer-in-Charge. |
| 22 | \\"SEWAGE DISPOSAL WORKS\\" |
| 23 | M&L for Construction RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, base slab, baffle walls and roof slab including beams etc. with vent shaft, manhole opening with cover connection etc., complete with effective depth of 1.5 mtr and overall depth 3 meter for 100 users with upflow filters etc., all as specified and shown on drawing complete, all as specified and directed by Engineer-in-Charge. |
| 24 | 15. M&L for Construction of soakage well in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring and solid in M-25 concrete including intercepting chamber, screen chamber brick work in CM, RCC cover slab in M-25/RR masonry/SFRC cover, interconnecting pipes of RCC/DWC, complete filled with brick bats, complete of size 1.8 M × 3.0 m deep. |
| 25 | \\"STREET LIGHT WORK\\" |
| 26 | Supply and fix LED street light fitting of not less than 90 watt, LED having 6000K/3000K CCT of IP 66 protected luminaire with high power LED enclosed in pressure die-cast aluminium frame IK-07, alongwith GI pipe 40 mm dia medium grade of length not less than 2.5 RM bend to an angle as per site directions, fixed to the pole/ Wall with MS clamp made up of 40 x 6 mm flat, nut, bolts, washers, etc complete all as specified and directed. |
| 27 | S&F SMC based outdoor type Junction Box pole mounted having four Nos aluminium bus bar 100 Amps for cable connections and looping including MCB SP 06 Amp, C Curve, 10 kA, fixed to pole/wall with necessary clamps, nuts, bolts etc., complete all as specified and directed. |
| 28 | \\"EXTERNAL ELECTRIC SUPPLY WORKS\\" |
| 29 | Supply, installting, Commissioning & testing HT 11 KV, 3 Phase 50 Hz , rupturing capacity 350 MVA indoor type , VCB PANEL totally metal clad withdrawable type Vacuum Circuit Breaker including suitable as Incomer , including cable connection with Copper busbar of suitable rating. horizontal isolation horizontal drawout type VCB of capacity minimum 800 Amps rated current, . The switchgear panel shall be made up of CRCA sheet steel duly powder coated or equivalant not less than 2.5mm thick for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof.Note: - Foundation as per Company Engineering Drawing is included in item Rate quoted by contractor .and all as per Directed By EIC.(i) Continuous current rating minimum-800A.(ii) Short circuit withstand current minimum 25 KVA for 1 Sec.(iii) Operating Mechanism of the VCB are suitable for 10000 Mechanical Operations(iv)CT Ratio should be 200-100/5-5, core 1: Class 1 ,15 VA Core 2: 5P10. 15VA burden(v)Cast resin drawout type potential transformer 11 KV/V3/110V/V3/110V/3, 100 VA , CI 0.5 (vi) Protection arrangements for the breaker shall comprise of the following:-(a)Each of the incomer switchgear units shall be provided with over current (50/51) and earth fault (50N/51N) protection, this relay shall also provide over voltage (59), under voltage (27),Line Differential(87L),over flux(24),phase protection function. The over voltage element shall have setting of 100 to 200% in steps of 1% and under voltage element shall have setting of 30 to 90% in steps of 1%. The main protection relays should be SCADA compatible with IEC 61850 Edition 2 on 2 nos. FO ports. Relay should generate GOOSE message as per IEC 61850 standard for interlocking and also ensure interoperability with third party relays. |
| 30 | (b)Master Trip Relay(c)TCS Relay(d)Surge Protection through LA(vii) The following meters, indications and acessories are to be provided with the panel: -(a) Digital Volt Meter/Ammeter with built in selector switch(b) Necessary DC Supply with powerpack, healthy indication lamp & switch.(c) Multi-function meter.(d) Control:-(d1) TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement.(d2) Local/remote selector switch for breaker open/close operations.VCB Panels should be Manufactured, designed & supplied by OEM only.VCB Panels from the System houses are not acceptableAll the main components like VCB/Relays/VI should be of same manufacturer.Vacuum interrupter shall be of OEM Make only.VCBs should be supplied with Vacuum interrupter with which Type Testing is doneThe offered panels shall be tested for IAC level of 25KA for 1Sec. VCBs should be Type Tested for E2/C2/M2 Class.VCB Should having inbuild power bank of OEM as per suitable rating with suitable Battery Bank of OEM .All type test should be as per as per IEC 62271-100-2021. |
| 31 | Supply, installation, testing and commissioning of 11 KV 630 Amps, 25kA/26.3KA for 3 Sec (Rated Short Circuit), extensible both side, Outdoor type, 3 way RMU with 2 LBS & 1 VCB, SF6 insulated, 11 KV Ring Main Unit contained within Robotically welded Stainless Steel Tank & RMU Main Tank should be of 3mm thick stainless steel robotically welded with degree of protection IP67 suitable for outdoor use, type tested for internal arc test for IAC AFL for 21KA for 1sec.HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works.Short Time withstand (STC) rating of the RMU should be 25kA/26.3KA for 3secs. Load Break Switch should be type tested for mechanical endurance of min.5000 nos. of operations. (M2 class).RMU shall be suitable for operation at an altitude of upto 1000 meter above MSL. RMU should be with manufacturers own make of Vacuum Interrupter & Self Powered Relay.The RMU shall be complete all as specified and directed and comprising of the following:- Note Foundation as per Company Engineering Drawing is included in item Rate quoted by contractor .and all as per Directed By EIC.(1) 630 Amp, 21KA, triple pole, manually operated Vacuum Ciruit Breaker encapsulated in SF6 Stainless steel tank with independent spring mechanism and fully rated earth switch with provision for earth of the cable.(2) cable boxes at each of the circuit breakers shall be suitable for bottom entry of HV cables of size up to 1x3C x 400 sq.mm and shall be located to the front/side/Rear side of the RMU.Necessary Terminal Protector Boots should be supplied with each RMU. Compound filled cable boxes are not acceptable |
| 32 | (3) 630 Amp, 21KA, triple pole, single break, 3-postion ('ON', 'OFF' and 'EARTH') ring main switches, each with independent manual charged spring mechanism and fully rated earth switch, with provision for earth and test of the cable.(4) cable boxes at each LBS shall be suitable for bottom entry of HV cables of size up to 1x3C x 400 sq.mm and shall be located to the front/side/Rear side of the RMU.Necessary Terminal Protector Boots should be supplied with each RMU. Compound filled cable boxes are not acceptableThe Ring Main Unit should comprise of the following accessories: (a) 1 Mimic diagram on front panel complete with status indicators. (b) 1 Set of positive standard mechanical interlocks. (c) Set of current transformers for protective relays with suitable ratio class CT 200-100/5 A, Class 5P10, 2.5VA for protection on each breaker portion.(d) Self Powered Numerical relay with 3 O/c and 1 E/F on each breaker. (e) 1 No. Battery 2x12V DC, 7AH rating (Battery life as per manufacturer standard)(f) Capacitor voltage dividers serving live-line cable indicators with Phase comparison sockets for each function.(g) 1 No. SF6 gas pressure indicator for each SF6 Gas tank.(h) Front bottom entry of HT cables.(j) Suitable right angle boots. (k) Cable Bushings should be site replaceable typeThe RMU Panel should have following general characteristics: |
| 33 | Rated Voltage : 11kVRated Power Frequency withstand Voltage : 28kVRated Lightning Impulse withstand Voltage : 75kVRated Frequency : 50 HzRated Current : 630 AmpsShort Time withstand Current & duration : 25kA/26.3 KA for 3 Secs Short Circuit Breaking Current : 21 KAShort Circuit Making Capacity : 52.5 KApCB Operating Duty Sequence : 0-3min-CO-3min-CORMU Should having inbuild power bank of OEM as per suitable rating with suitable Battery Bank of OEM . |
| 34 | Supply, installation, testing and commissioning of 11 KV 630 Amps, 25kA/26.3KA for 3 Sec (Rated Short Circuit), extensible both side, Outdoor type, 4 way RMU with 1 LBS & 3 VCB, SF6 insulated, 11 KV Ring Main Unit contained within Robotically welded Stainless Steel Tank & RMU Main Tank should be of 3mm thick stainless steel robotically welded with degree of protection IP67 suitable for outdoor use, type tested for internal arc test for IAC AFL for 21KA for 1sec.HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works.Short Time withstand (STC) rating of the RMU should be 25kA/26.3KA for 3secs. Load Break Switch should be type tested for mechanical endurance of min.5000 nos. of operations. (M2 class).RMU shall be suitable for operation at an altitude of upto 1000 meter above MSL. RMU should be with manufacturers own make of Vacuum Interrupter & Self Powered Relay.The RMU shall be complete all as specified and directed and comprising of the following:- Note Foundation as per Company Engineering Drawing is included in item Rate quoted by contractor .and all as per Directed By EIC.(1) 630 Amp, 21KA, triple pole, manually operated Vacuum Ciruit Breaker encapsulated in SF6 Stainless steel tank with independent spring mechanism and fully rated earth switch with provision for earth of the cable.(2) cable boxes at each of the circuit breakers shall be suitable for bottom entry of HV cables of size up to 1x3C x 400 sq.mm and shall be located to the front/side/Rear side of the RMU.Necessary Terminal Protector Boots should be supplied with each RMU. Compound filled cable boxes are not acceptable. |
| 35 | (3) 630 Amp, 21KA, triple pole, single break, 3-postion ('ON', 'OFF' and 'EARTH') ring main switches, each with independent manual charged spring mechanism and fully rated earth switch, with provision for earth and test of the cable.(4) cable boxes at each LBS shall be suitable for bottom entry of HV cables of size up to 1x3C x 400 sq.mm and shall be located to the front/side/Rear side of the RMU.Necessary Terminal Protector Boots should be supplied with each RMU. Compound filled cable boxes are not acceptableThe Ring Main Unit should comprise of the following accessories: (a) 1 Mimic diagram on front panel complete with status indicators.(b) 1 Set of positive standard mechanical interlocks. (c) Set of current transformers for protective relays with suitable ratio class CT 200-100/5 A, Class 5P10, 2.5VA for protection on each breaker portion.(d) Self Powered Numerical relay with 3 O/c and 1 E/F on each breaker. (e) 1 No. Battery 2x12V DC, 7AH rating (Battery life as per manufacturer standard)(f) Capacitor voltage dividers serving live-line cable indicators with Phase comparison sockets for each function.(g) 1 No. SF6 gas pressure indicator for each SF6 Gas tank.(h) Front bottom entry of HT cables.(j) set of right angle boots. (k) Cable Bushings should be site replaceable typeThe RMU Panel should have following general characteristics: Please Enable Macros to View BoQ information |
| 36 | (3) 630 Amp, 21KA, triple pole, single break, 3-postion ('ON', 'OFF' and 'EARTH') ring main switches, each with independent manual charged spring mechanism and fully rated earth switch, with provision for earth and test of the cable.(4) cable boxes at each LBS shall be suitable for bottom entry of HV cables of size up to 1x3C x 400 sq.mm and shall be located to the front/side/Rear side of the RMU.Necessary Terminal Protector Boots should be supplied with each RMU. Compound filled cable boxes are not acceptableThe Ring Main Unit should comprise of the following accessories: (a) 1 Mimic diagram on front panel complete with status indicators.(b) 1 Set of positive standard mechanical interlocks. (c) Set of current transformers for protective relays with suitable ratio class CT 200-100/5 A, Class 5P10, 2.5VA for protection on each breaker portion.(d) Self Powered Numerical relay with 3 O/c and 1 E/F on each breaker. (e) 1 No. Battery 2x12V DC, 7AH rating (Battery life as per manufacturer standard)(f) Capacitor voltage dividers serving live-line cable indicators with Phase comparison sockets for each function.(g) 1 No. SF6 gas pressure indicator for each SF6 Gas tank.(h) Front bottom entry of HT cables.(j) set of right angle boots. (k) Cable Bushings should be site replaceable typeThe RMU Panel should have following general characteristics: Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 31 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender