Tender For Repair/ Maintenance Of High Mast Light, Floods Lights, Solar Light, Gate/ Garden Lights, Post Top Light, Solar Water Heater And Improvement Of Em Installations At Itarana Mil Stn Under Ge Alwar
Tender Value
91 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
25 days left
EMD
1.61 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Alwar → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of High Mast Light, Floods Lights, Solar Light, Gate/ Garden Lights, Post Top Light, Solar Water Heater And Improvement Of Em Installations At Itarana Mil Stn Under Ge Alwar
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting and taking down the street light fitting from the pole and repair of street light fitting of any type, capacity & make by replacement of unserviceable spare parts & making the fitting functional and refixing after repairs all as specified and directed by Engineer-in-Charge. |
| 2 | Disconnecting and taking down High Mast light from the steel tower and repair of High Mast fitting of any type, capacity & make by replacement of spare parts & making the fitting functional and refixing after repairs all as specified and directed by Engineer-in-Charge. Note for item No. 1 & 2 : (i) Spare parts/accessories required to be replace shall be measured and paid seperately as \\"supply only\\" under the relevent items. (ii) Scope of work including for minor stores ie. PVC insulation tap, screw, insulation sleeve, nut bolt & washer and flexible cable 2.5 sq mm. (iii) Any complaint measured one time in same location/pole/light during contract period. No extra payment will be made for repeating complaint on same location during contract period. (iv) Contractor shall depute daily two Nos mistry/electrician in MES office (MRS) for receiving and rectify the complaint. (v) The rate including all the T&P of i.e. ladder/vehicle/required for execution of work shall be arranged by the contractor. |
| 3 | Supply only for repairs surge protection device (SPD) for LED street light fitting (45-60) watt. |
| 4 | Supply only for repairs BIS registered potted electronic driver suitable for LED street light fitting (45-60) watt. |
| 5 | Supply only for repairs surge protection device (SPD) for LED street light fitting (72-90) watt. |
| 6 | Supply only for repairs BIS registered potted electronic driver suitable for LED street light fitting (72-90) watt. |
| 7 | Supply only for repairs surge protection device (SPD) for LED street light fitting (100-150) watt. |
| 8 | Supply only for repairs BIS registered potted electronic driver suitable for LED street light fitting (100-150) watt. |
| 9 | S&F in repair for 2.5 sqmm, PVC insulated, Round Sheathed, twin core aluminium Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694, from street light feeder/junction box to street light fittings |
| 10 | S&F in repair for 2.5 sqmm, PVC insulated and FRLS PVC Round Sheathed, twin core Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694, from street light feeder/junction box to street light fittings |
| 11 | S&F in repair for 6 sqmm PVC insulated & sheathed single core copper conductor cable repair for street light feeder panel /junction box/re-wiring fitting-fixtures etc. |
| 12 | M&L in repairs for rigid steel conduit, welded of 20 mm dia for protection of wire fixing on pole as required with 2 Nos clamps complete all as specified and directed by Engr-in-Charge. |
| 13 | S&F in repairs street light bracket made to shape at required angle made out of 40 mm dia ( light grade ) GI tubing of length not less than 1.2m long suitable for fixing /holding street light fittings including mild steel flate iron 50 x 6 mm clamp 02 Nos with bolts, nuts and washer complete all as specified & directed. |
| 14 | S&F in repairs decorative gate light/garden light made up of high grade unbreakable (MUSHROOM PRISMATIC) polycarbonate material including 10/12W LED Lamp B22 base including taking down of old U/S light. |
| 15 | S&F in repair for pole mounted juction box made out of one piece moulded SMC IP65 protection having aluminium bus bars 100 Amp single phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance free size 300x200x100 mm fixing on pole with MS flat 25x3mm clamp including nut bolts front openable all as specified and directed. |
| 16 | S&F in repair of Automatic street light switch using Infrared Sensor based three phase Nature Switch for automatic switching off street lights, Nature switch operation should be based on Natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. 03 Nos contactors each of 25 Amp and incoming-outgoing MCBs single pole (03 Nos each) rating 25 Amp and Auto/Manual (sensor By pass) selection option should be enclosed in a pole/wall mountable enclosure made of Rust proof , Electric shock proof, Termite proof and FR grade SMC junction box conforming to IP-54.Model : complete all as directed by Engr-in-Charge. |
| 17 | Replacement of old unsv & Supply, Installation, commissioning and testing of Lithium based energy integrated solar street light 40 Watt in single metal/FRP body encases solar panel 44/46Wp monocrystalline, Lithium ferro phosphate battery, solar panel and charger built into the luminaire 11.1/12.8V, 42AH with inbuilt BMS, High brightness W-LED (160-180 lm/watt) lamp, CRI>0, Colour temperature 6500K, microcontrollerbased charge controller cum driver, automatic dimming function with PIR motion senor, Dusk to down operation, working temperature: (-) 10C to (+) 55C, weight: 10-12 kg, with adjustable MS clamp, bracket suitable for pole/wall mounting, protection : Short circuit, overload, Reverse polarity and battery protections complete all as specified. NOTE- (i) Firm should give warranty for the complete fitting including all Electric/Electronics connected parts for minimum 5 years. (ii) The complete documents regarding warranty shall be handed over to the GE at the time of execution of the items. In turn contractor may obtain. Warranty/ Extended warranty from the manufacturer for the above period. |
| 18 | Repairs to Street light panels and Nature switch by replacement of unserviceable electric items such as Timer, contactor, MCB, MCCB, busbar etc wiring of suitable size copper conductor cable single core etc and setting of timer including dismantling of unserviceable parts. Note : Spare parts measured and paid seperately under the relevent item as \\"Supply only\\" |
| 19 | Supply& fixing in repairs MCB SP 6 to 32 Amps , 230 Volts, AC complete. |
| 20 | Supply only selecter switch four step. |
| 21 | Supply only electric contactor 3 pole suitable for (25-40) Amps 240 Volts AC complete. |
| 22 | Supply only Astronomical time switch Digital type for street light 240 volts , 50 Hz complete. |
| 23 | M&L for painting of APFC/LT/SL panel board of any sizes with one coats of synthetic enamel paint smoke grey including preperation of old painted surfaces by scrapping of old surface and making good surface all as specified and directed by Engineer-in-charge. |
| 24 | M&L for earthing in repairs complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m deep below normal ground level and connected to and including galvanized iron strip 25x4 mm as earth lead by means of GI nuts, bolts, check nuts, washers thimbles, etc. as shown in electrical plate No. 3 of SSR Part-I and connection to main switch board/test point/panel/equipment and testing on including excavation and earth work in any type of soil, returning filling in, and removal of surplus soil to a distance not exc. 50m, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20mm bore for watering and 40 mm bore 3m long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25mm x 3mm bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided with CI frame etc.complete all as specified & as directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 40 mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 25 | S&F in repairs steel tubular swaged pole 09 meter long type 410 SP-31 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.20 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint over a coat of aluminium red oxide primer to remaining portion of pole and marking pole number and including dismantling and taking down old unserviceable PCC pole of any size/height & type including earth work incl demolition of PCC all as specified & as directed. Note : (i) Excavation & earthwork, PCC in foundation & coping shall be measured and paid for separately. (ii) Serviceable street light fitting and pole mounted junction box taking out from u/s pole and same refixing to the new pole. |
| 26 | Supply and laying in replacement XLPE insulated, armoured, heavy duty electric cables with stranded aluminium conductor, 1100 volts laid in trenches, ducts, pipes, drawn across the roads/paths/drains/along poles/walls/floors/equipment etc including jointing and testing complete all as specified of size 4 core 25 sqmm. |
| 27 | (A) All as per item No 26 but of size 10 Sqmm x4 core |
| 28 | (B) All as per item No 26 but of size 10 Sqmm x 2 core |
| 29 | (B) All as per item No 26 but of size 16 Sqmm x 2 core |
| 30 | (B) All as per item No 26 but of size 16 Sqmm x 4 core |
| 31 | (B) All as per item No 26- but of size 6 Sqmm x 2 core |
| 32 | Excavation in trenches n. exc. 1.5Mtr width n.exc 1.5 Mtr in depth for laying of cables & foundation of poles, stay assembly and getting cut in any type of soil. |
| 33 | M & L for sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment. |
| 34 | M/L for brick work with FLY ASH BRICKS as Per IS-13757(1993) burnt clay fly ash building bricks, with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed. |
| 35 | Returning, filling in including spreading levelling , watering and well ramming in layers not exc. 25cm in any type soil |
| 36 | Removing of surplus excavated soil to a distance not exc. 50m and depositing where directed at a levelnot exc 1.5 Mtr abovethe starting point. |
| 37 | M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, or fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete all as specified and directed. |
| 38 | Boring of holes under road,pavement, hard standing by trench less technology using ultra sound technique and necessary machine including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure. |
| 39 | S&F in repairs LED flood light 150 Watt 230 volt AC outdoor type made up of pressure die cast aluminium housing with integrated IP lens and SMD LEDs with IP-66 protection with efficiency 120 lumens per watt alongwith 10kv SPD including all fixing accessories complete. |
| 40 | All as per item ser No. 39.00 here-in-before but of cap 200Watt. |
| 41 | All as per item ser No. 39.00 here-in-before but of cap 250Watt. |
| 42 | M&L for flexible steel spring pipe, 25 mm dia for protection of wire fixing on pole as required complete all as specified and directed by Engr-in-Charge. |
| 43 | Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule complete all as specified. |
| 44 | M&L for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation of stay assembly & poles and similar works complete all as specified.Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. |
| 45 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate in mass concrete for pole all as directed by Engineer-in-Charge. |
| 46 | M&L for PCC 1:2:4 type B2 using 20 mm graded stone aggregate in coping concrete for pole all as directed by Engineer-in-Charge. |
| 47 | M&L for painting to PCC LT pole 9 metre long of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.2 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint over cross arms, brackets, bracings, clamps, hooks etc and marking pole numbers including preparation of old surfaces for painting complete all as specifiedand directed. |
| 48 | M&L for painting to steel tubular LT pole 9 metre long of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.2 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint to remaining portion of steel pole, over cross arms, brackets, bracings, clamps, hooks etc and marking pole numbers including preparation of old surfaces for painting complete all as specified and directed. |
| 49 | Supply and fixing MCCB, 4 Pole, 415 Volts -50HZ , Magnetic fix type 25 to 63 Amps,16 KA capacity including dismantling of unservieable MCCBs. |
| 50 | Supply and fixing MCCB, 4 Pole, 415 Volts -50HZ , Magnetic fix type 100 Amps, 16 KA capacity including dismantling of unservieable MCCBs. |
| 51 | Supply and fixing Globe shaped light for Existing garden light in frosted finish made up of Polycarbonate suitable for LED 9/10 watt all as specified and directed & taking out old U/S Globe. |
| 52 | S & F Garden light BAMBOO Type fitting LED 9 W including LED lamp and necessary PCC work/FI nuts, bolts for mounting the fitting complete all as directed by Engineer-in-Charge including taking down U/S light any type any size . Make : Havells Cat No. LHEVBDP71N6K008 or equivalent in list of makes |
| 53 | S&F MCCB ,4 pole ,250 Amps. Rating rupturing capacity 36 KA ,415 Volts grade AC,50Hz ,with adjustable thermal ,magnetic release and making connections ,including disconnecting and taking down old U/S MCCB ,complete all as specified and directed. |
| 54 | S&F MCCB ,4 pole ,160 Amps. Rating rupturing capacity 36 KA ,415 Volts grade AC,50Hz ,with adjustable thermal ,magnetic release and making connections ,including disconnecting and taking down old U/S MCCB ,complete all as specified and directed. |
| 55 | S&F in repairs LED security light fitting 90 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete. |
| 56 | All as per item ser No. 56.00 here-in-before but of cap 100Watt. |
| 57 | All as per item ser No. 56.00 here-in-before but of cap 120Watt. |
| 58 | S&F in repairs post top lantern LED type 20 watt 230V AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 59 | S&F in repairs post top lantern LED type 40 watt 230V AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 60 | S&F in repairs street light fittings MONARCH, cast iron pole 4mtr height, antique copper colour, incl 2x40 watt LED light bowl type incl 2.5 sqmm pvc copper cable connecting to LED lamp and base of wiring pole is provided with 3 Nos of hot dip galvanised type anchor bolts incl earth work and PCC 1:3:6 C2 using 40 mm graded stone aggregate as in foundation size 45x45x150cm for poles. |
| 61 | S&F in repairs decorative colour of 3 mtr length having pole material GI PU painted pipe and light material as polycarbonate acrylic of length as per Halonix Cat Part No HLDC-45-75-TRI-3M with rated voltage and frequency 240V 150 Hz, system voltage 75W ±10%, system current <0.382mA power factor >0.90 colour out put suffron, white & green (Tiranga colour with same sequence) and driver efficiency ≥80%. Base plate of the pole light shall be of dia 300mm and thickness 12mm PCB hole 260mm dia & 25mm dia light shall be mounted on a half feet PCC plaster, properly fixed with plate and foundation bolts. Make : Halonix or equivalent in list of makes. |
| 62 | M&L of broken coping/new/ refixing of existing pole with PCC 1:2:4 type B2 using 20 mm graded stone aggregate in coping concrete for pole INCLUDING TAKING DOWN OLD all as directed by Engineer-in-Charge. |
| 63 | M & L for servicing of complete Solar Heating System of 100 LPD to 500 LPD comprising of solar flat plate collector/tube type collector. The detail scope of work consists of the following (i) Cleaning of solar flat plate collector with detergent and after that with coline solution and removing all type of grease/mud etc and cleaned as per direction. (ii) Cleaning/descaling of complete copper tubing system of solar flate plate collector with suitable cleaning solution including necessary brazing welding if required/repair to leakage and tested as per OEM direction.(iii) Taking down, cleaning of tube of ETC type collector and refixing of tubes, checking and prevention of any leakages, functioning of NRV & gate valves . (iv) Cleaning of hot water MS tank with cleaning agent and necessary gas welding/brazing if required to stope minor leakage. (v) Cleaning of OHT water tank connected with storage hot water tank of geyser. Note: Hose pipe clamps, nut, bolt, washer etc for replacement shall be measured and paid seprately under relevent item of this schedule. |
| 64 | S&F polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 1000 LPD complete all as specified and directed by Engr-in-Charge including taking down old unserviceable items. |
| 65 | S&F polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 500 LPD complete all as specified and directed by Engr-in-Charge including taking down old unserviceable items. |
| 66 | S&F polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 200 LPD complete all as specified and directed by Engr-in-Charge including taking down old unserviceable items. |
| 67 | S&F polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 100 LPD complete all as specified and directed by Engr-in-Charge including taking down old unserviceable items. |
| 68 | S&F tubes of Evacuated tube collector (ETC) type 1800mm long tubes with inner dia 47mm and outer dia 58mm with frame and frame angle 30 degree complete all as specified and directed by Engr-in-Charge including taking down old unserviceable items. |
| 69 | S&F tubes of Evacuated tube collector (ETC) type 2100mm long tubes with inner dia 47mm and outer dia 58mm with frame and frame angle 30 degree complete all as specified and directed by Engr-in-Charge including taking down old unserviceable items. |
| 70 | S & F 1000 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with thermostat and heater coil 3 KW and suitable size of MS powder coated stand 50x5 mm angle frame with required PCC work 1:2:4 for foundation/fixing all as specified and directed by Engr-In-Charge including taking down old unserviceable items. |
| 71 | S & F 500 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with thermostat and heater coil 3 KW and suitable size of MS powder coated stand 50x5 mm angle frame with required PCC work 1:2:4 for foundation/fixing all as specified and directed by Engr-In-Charge including taking down old unserviceable items. |
| 72 | S & F 200 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with thermostat and heater coil 3 KW and suitable size of MS powder coated stand 35x4 mm angle frame with required PCC work 1:2:4 for foundation/fixing all as specified and directed by Engr-In-Charge including taking down old unserviceable items. |
| 73 | S & F 100 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with thermostat and heater coil 3 KW and suitable size of MS powder coated stand 35x4 mm angle frame with required PCC work 1:2:4 for foundation/fixing all as specified and directed by Engr-In-Charge including taking down old unserviceable items. |
| 74 | S & F 500 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with 30/32 tube holes of 58mm diameter and outer PPGI with thermostat and heater coil 3 KW and suitable size of MS powder coated stand 50x5 mm angle frame with required PCC work 1:2:4 for foundation/fixing all as specified and directed by Engr-In-Charge including taking down old unserviceable items. |
| 75 | S & F 200 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with 20 tube holes of 58mm diameter and outer PPGI with thermostat and heater coil 3 KW and suitable size of MS powder coated stand 35x4 mm angle frame with required PCC work 1:2:4 for foundation/fixing all as specified and directed by Engr-In-Charge including taking down old unserviceable items. |
| 76 | S & F 100 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with 10 tube holes of 58mm diameter and outer PPGI with thermostat and heater coil 3 KW and suitable size of MS powder coated stand 35x4 mm angle frame with required PCC work 1:2:4 for foundation/fixing all as specified and directed by Engr-In-Charge including taking down old unserviceable items. |
| 77 | S&F for heating element for solar water heating system of capacity 2 KW and including taking down existing heating element complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items. |
| 78 | S&F for heating element for solar water heating system of capacity 3 KW and including taking down existing heating element complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items. |
| 79 | S&F for thermostat 2/3 KW suitable for 100 to 1000 litres capacity of solar water heater and including taking down existing thermostat complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items. |
| 80 | Supply & Fix for rotational moulded synthetic (HDPE) water storage tank of capacity of 1000 litre capacity triple layered, cylindrical vertical with closed top hoisted and fixed in position and including taking down existing tank all as specified in SSR Part-I complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items. |
| 81 | Supply & Fix for rotational moulded synthetic (HDPE) water storage tank of capacity of 500 litre capacity triple layered, cylindrical vertical with closed top hoisted and fixed in position and including taking down existing tank all as specified in SSR Part-I complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items. |
| 82 | S&F for GI tubing 20 mm dia medium grade galvanised with necessary fittings such as tees, elbows, bends, reducers, union etc laid in wall ceiling & Floor including all fittings and including taking out existing tubing complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items. |
| 83 | S&F for GI tubing 15 mm dia medium grade galvanised with necessary fittings such as tees, elbows, bends, reducers, union etc laid in wall ceiling & Floor including all fittings and including taking out existing tubing complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items. |
| 84 | M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.00 Sqmm (FRLS) in PVC casing caping including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 4.00 Sqmm (FRLS) of continous earth wire green in colour and including taking down existing submain wiring complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items.(Note :- Two runs of 4.00 Sqmm cable & one run of 4.00 Sqmm cable shall be paid as one unit length) |
| 85 | S & F sheet metal single pole and neutral enclosure with a two pin and eath plug and socket complete with one single pole MCB 20 Amp 240 V and including taking down existing plug complete all as specified & directed by Engineer-in-charge. |
| 86 | S&F in repair sheet metal enclosure MCB SPN DB 2 way 240 volts single door with magnetic locking system complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items. |
| 87 | S&F in repair MCB's single pole and neutral 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items. Please Enable Macros to View BoQ information |
| 88 | S&F in repair MCB's single pole and neutral 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge including taking down old unserviceable items. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 25 daysAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender