Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #56736695

Tender For Repair Maintenance Of Air Conditioning And Refrigeration System Ac Plant At Af Stn Sarsawa Under Ge Af Sarsawa

Issued by Statutory Bodies & Commissions/Committees · Saharanpur, Uttar Pradesh
Tender Value
30 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
8 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Saharanpur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Maintenance Of Air Conditioning And Refrigeration System Ac Plant At Af Stn Sarsawa Under Ge Af Sarsawa

BOQ

Name of Work:- REPAIR MAINT OF AIR CONDITIONING AND REFRIGERATION SYSTEM AC PLANT AT AF STN SARSAWA UNDER GE AF SARSAWA
Sl. No. Item Description
1Periodical servicing/maintenance of floor mounted Air Handling Unit (AHU) of capacity 8338 CFM by carrying following works :-(i) Removal of air filters (primary & secondary) from filter section, removal of dirt/dust partical by compressed air blower followed by washing under running tap water and refixing at site after complete dry .(ii) Removal of dirt/dust particals from aluminium fins of cooling coil by soft brushing followed by air blowing and cleaning of cooling coil by forced spray chemically (such as veni clean solution) all as directed by Engineer-in-Charge.(iii) Cleaning & removing of complete scale from bottom tray and drain pipe of AHUs as directed at site by the Engineer-in-Charge.(iv) Cleaning of drain pipe from AHUs tray to out side plant room manually as well as any de-scaling solution for draining. (v) Checking serviceability/tightening of fan motor V-belt, pulley block, fan blades assembly. (vi) Checking serviceability/tightening of AHU door lache and greasing/oiling.
2All as per Item No. 1.00 here-in-before but for floor mounted AHU of capacity 8342 CFM.
3All as per Item No. 1.00 here-in-before but for floor mounted AHU of capacity 6043 CFM.
4All as per Item No. 1.00 here-in-before but for floor mounted AHU of capacity 4738 CFM.
5All as per item srl no. 1 here in before but for celing suspended AHU of capacity 4200 CFM
6Material and labour for leakage detection in refrigeration line circuit of scroll chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in 0- charge
7Material and labour for leakage detection in refrigeration line circuit of s package type AC plant of capacity 16.5 TR chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in-charge.
8Material and labour for leakage detection in refrigeration line circuit of s package type AC plant of capacity 9 TR chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in-charge.
9Material and labour for leakage detection in refrigeration line circuit of s package type AC plant of capacity 7 TR chiller, plugging the same, nitrogen pressure testing, vacummizing and testing and commissioning complete all as specified and directed by Engineer -in-charge.
10Material and labour for De-Scaling of 13 TR condenser cells & tubes unit by chemical circulation, rodding with wire brush to remove deposited scale in condenser including replacement of end plate gasket complete all as specified and directed by Engineer -in-charge.
11Material and labour for charging of refrigerant gas 407C complete all as specified and directed by Engineer -in-charge.Make :Floron/Mrfron/DuPont/MPCL
12Material and labour for charging of refrigerant gas 410 complete all as specified and directed by Engineer -in-charge.Make :Floron/Mrfron/DuPont/MPCL
13Material and labour for charging of refrigerant gas R22 complete all as specified and directed by Engineer -in-charge.Make :Floron/Mrfron/DuPont/MPCL
14Supply & fix in replacement washable synthetic non vowen type pre air filter having efficiency 90% down to 10 Micron of size :- 610 x 610 x 50 mm complete all as specified and directed by Engineer -in-charge.Make: Llyod/Mihir/Danfoss/Indfoss
15All as per Item No. 14.00 here-in-before but of size 610 x 305 x 50 mm.
16Supply & fix in replacement box type bag filter of class MERV-13 washable :- 610 x 610 x 50 mm complete all as specified and directed by Engineer -in-charge.(Make: Llyod/Mihir/Danfoss/Indfoss)
17All as per Item No. 14.00 here-in-before but of size 610 x 305 x 50 mm.
18Supply and fix in replacement of fan belt (Model No A 1509 LP/A 58) for AHU blower motor complete all as specified and directed by Engineer -in-charge.Make : Fenner/Polyplus/Dunlop.
19Supply and fix in replacement mecury in glass filled industrial thermometer 100mm dia SS of temp range 0-50 deg centigrade complete with syphon and isolating valve complete all as directed by Engr-in-Charge.Make : Fiebig/H. Guru/Emerald
20Supply and fix in replacement industrial type pressure gauge 100 mm dia SS of dual pressure range PSI & Kg/Sqcm (0-150PSI & 0-10.6Kg/Sqcm) complete with syphon and isolating valve complete all as specified and directed by Engineer -in-charge.Make : Fiebig/H. Guru/Emerald
21Supply and fix in replacement of water flow switch having pressure rating 150 PSI, temp rating 100 deg centigrade, switching current rating 15Amp, 250V suitable for 25mm thread mounting complete all as specified and directed by Engineer -in-charge.Make : Honeywell/Rapid Cool/Danfoss
22Supply and fix in replacement hermetic type liquid line filter drier having MAP/MWP : 667 psig/46 bar complete all as specified and directed by Engineer -in-charge.Make : Honeywell/Rapid Cool/Danfoss
23Supply and fix in replacement scroll compressor Model No. SZ185S4RC suitable for water cooled chiller unit complete all as specified and directed by Engineer -in-charge.Make : Danfoss/equivalent
24Supply and fix in replacement anti freeze thermostat in chiller line of adjustable range -30 to +15 deg C complete with stainless steel capillary tube of 2m long with bolted connector, IP44. Make :- Sporlon/Danfoss/Alco/Indfoss/Carel.
25Material and labour for periodical servicing/maint of electric driven condensor pump set of rating 10HP comprising of following job works :-(i) Removal of pump set from condenser line and foundation.(ii) Dismantling of motor end covers and taking out stator unit(iii) Removal of carbon/dust particals from motor stator winding by air blower followed by its chemical washing and varnishing complete as directed by Engineer-in-Charge.(iv) Greasing of bearings. (v) Checking & tightening of pump impeller. (vi) Re-fixing of pump set in position and making all connections and testing complete.
26All as per item No. 25 here-in-before but chiller pump set of capacity 7.5HP.
27All as per item No. 25 here-in-before but CT fan motor of capacity 5 HP.
28All as per item No. 25 here-in-before but blower motor of floor mounted AHU of capacity 5 HP.
29All as per item No. 25 here-in-before but blower motor of celing suspended AHU of capacity 2 HP.
30All as per item No. 25 here-in-before but blower motor of outdoor unit of capacity 0.5/1 HP.
31Material and labour for rewinding of squarell cage induction motor 3-phase, 415V, 2900 RPM, 10 HP with supper enamelled copper wire as per original gauge and pattern including removal, refixing, to & fro transportation, electrical connection at site and testing complete all as specified and directed by Enginee-in-Charge.
32All as per item No. 31 here-in-before but of capacitity 7.5HP.
33All as per item No. 31 here-in-before but of capacitity 5HP.
34All as per item No. 31 here-in-before but of capacitity 2 HP.
35All as per item No. 31 here-in-before but of capacitity 1/0.5 HP.
36Taking out / down faulty, unserviceable LT UG cable from trenches/duct/ LT poles, nominal cross sectional area from 10 sqmm to 50 Sqmm including disconnecting of cable and taking out PCC covers of any description complete all as specified & directed. Notes: (i) Excavation & Earth work shall be measured & paid separately.(ii) Serviceable cable covers/bricks will be kept aside for re-use and the unserviceable one shall be credited to contractor.
37Supply, laying and testing of XLPE insulated PVC innersheathed GI wire armoured, heavy duty electric cable with copper conductor ,1100 volts grade cross sectional area 10 Sqmm, 3 core as per IS 7098(Part-1) 1988 amended up to date, laid on wall/celing/floor with appropriate GI clamps / fixing arrangement with termination with copper lugs as per standard practice complete all as specified and directed.
38Supply, laying and testing in replacement XLPE insulated PVC innersheathed GI wire/strip armoured, heavy duty electric cable with stranded aluminium conductor ,1100 volts grade cross sectional area 50 Sqmm, 3.5 core as per IS 7098(Part-1) 1988 amended up to date, laid on wall/celing/floor with appropriate GI clamps / fixing arrangement with termination with aluminium lugs as per standard practice complete all as specified and directed.
39Supply, laying and testing in replacement XLPE insulated PVC innersheathed GI wire/strip armoured, heavy duty electric cable with stranded aluminium conductor ,1100 volts grade cross sectional area 16 Sqmm, 4 core as per IS 7098(Part-1) 1988 amended up to date, laid on wall/celing/floor with appropriate GI clamps / fixing arrangement with termination with aluminium lugs as per standard practice complete all as specified and directed.
40Supply, laying and testing in replacement XLPE insulated PVC innersheathed GI wire/strip armoured, heavy duty electric cable with stranded aluminium conductor ,1100 volts grade cross sectional area 25 Sqmm, 4 core as per IS 7098(Part-1) 1988 amended up to date, laid on wall/celing/floor with appropriate GI clamps / fixing arrangement with termination with aluminium lugs as per standard practice complete all as specified and directed.
41Supply & fixing PVC insulated unsheathed with stranded copper conductor of 06 Sqmm single core, green colour, FRLH, 1100 V grade as per IS 694, laid on wall/celing/floor with appropriate GI clamps / fixing arrangement with termination with copper lugs as per standard practice complete all as specified and directed.
42Supply and fixing in replacement single phase preventer 415 V AC, 50 Hz with tripping provision on reverse phase,phase failiure, over/under voltage complete all as specified and directed. Make : Minilec/Bentex/BCH
43Supply and fix in replacement non skid synthetic rubber insulated mat 2mm thick for voltage upto 3.3 KV for electrical pupose as per IS 15652-2006 of size 2mx1m complete all as specified and directed. Make : Vardhman/Jyoti/Safe Volt
44Material and labour for Earthing in replacement complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised iron earth strip 32 X 6 mm by means of bolts, washers ,watering pipe 20mm dia, medium grade GI pipe,with welded funnel and wire mesh and 40mm dia medium grade GI pipe with fitting as protection pipe for strip from plate electrode to test point /plant/machineries etc. including concrete pit in PCC (1:3:6) type C-I having outer dimension 60cmx60cmx60cm and internal dimension 30cmx30cmx30cm, pre-caste RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia deformed bares @15 cm centre to centre both direction and 10 mm dia MS handle of suitable size charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in electrical plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
45Supply and fixing in replacement 32mm x 6 mm GI strip earth continuity conductor or main earthing lead fixed to wall on wooden gutties or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified and directed.
46Supply and fixing in replacement 4.00 mm dia GI wire as earth continuity conductor or main earthing lead fixed to wall on wooden gutties or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified and directed.
47Supply and fixing in replacement of 100mm dia Butterfly valves (Manualy operated) with CI Body, stainless steel disc, nitrile rubber seal & O ring,PN-16 Pressure rating for chilled water circulation complete all as specified and directed.Make : Zoloto/Bir/Advance
48Supply and fixing in replacement of 80mm dia Butterfly valves (Manualy operated) with CI Body, stainless steel disc, nitrile rubber seal & O ring,PN-16 Pressure rating for chilled water circulation complete all as specified and directed.Make : Zoloto/Bir/Advance
49Supply and fixing in replacement of 50mm dia Butterfly valves (Manualy operated) with CI Body, stainless steel disc, nitrile rubber seal & O ring,PN-16 Pressure rating for chilled water circulation complete all as specified and directed.Make : Zoloto/Bir/Advance
50Supply and fixing in replacement Y-strainer CI body with SS strainer for water circuit complete with all fittings, jointing materials etc suitable for 100 mm dia complete all as specified and directed. Make : Zoloto/Bir/Emrerald
51Supply and fixing in replacement Pot -strainer CI body with SS strainer for water circuit complete with all fittings, jointing materials etc suitable for 100 mm dia. Make : Zoloto/Bir/Emrerald
52Supply and fixing in replacement gun metal gate valve for water circuit complete with all fittings, jointing materials etc suitable for 20 mm dia complete all as specified and directed.Make : Zoloto/Bir/Emrerald
53Supply and fix in replacement gun metal gate valve for water circuit complete with all fittings, jointing materials etc suitable for 25 mm dia. Make : Zoloto/Bir/Emrerald
54Supply and replacement of copper tubing 1/4 \\" (as per sample) at installation all as directed by Engr-in-charge.
55Supply and replacement of copper tubing 5/8 \\" (as per sample) at installation all as directed by Engr-in-charge.
56Supply and replacement of brass flow nuts 1/4 \\" to 5/8 \\" (as per sample) all as specified and directed.
57S&F aluminium powder coated bird screen with front side lovers and back side jali for free flow air and tripping big size mosquitto and particles comple all as specified and directed.
58Supply & fixing in replacement Electronic starting circuit relay circuit for 8.75 TR compressor (As per sample) complete all as specified and as directed. complete all as specified and directed by Engr-in-Charge. Make Blue star/equivalent as replaced
59Supply & fixing in replacement sealed unit compressor of cap 7.0 TR suitable for package type AC complete all as specified and as directed by Emgr-in-Charge.Note : Repaired and repainted compressor not accepted only gnuine compressor are accepted. with test report and year warranty certificate from OEM. Make :Voltas / equivalent as replaced
60Supply & fix in replacement sealed unit compressor of cap 5.5 TR suitable for package type AC complete all as specified and as directed by Emgr-in-Charge.Note : Repaired and repainted compressor not accepted only gnuine compressor are accepted. with test report and year warranty certificate from OEM complete all as specified and directed.Make :Voltas / equivalent as replaced
61Supply & fix in replacement sealed unit compressor of cap 4.5 TR suitable for package type AC complete all as specified and directed by Engr-in-Charge.Note : Repaired and repainted compressor not accepted only gnuine compressor are accepted. with test report and year warranty certificate from OEM complete all as specified and directed.Make Blue star /equivalent as replaced
62Material and labour for replacement of compressor oil suitable for danfoss make scroll chillers complete all as specified and directed.
63Supply and fixing as in replacement ball bearing No.6205 complete all as specified and directed. Make : SKF/NBC/TATA
64Supply and fixing as in replacement ball bearing No.6203 complete all as specified and directed. Make : SKF/NBC/TATA
65Supply and fixing as in replacement terminal plate suitable for 10HP/7.5 HP motor complete all as specified and directed.
66Material and labour for remetalling of bearing housing in 5HP to 10 HP rating motor end cover with machineble welding rod lathe work to make size as per inner dia of bearing and polishing complete all as directed by Eng-in-Charge
67Material and labour for remetalling of bearing seat on shaft of 5HP to 10 HP rating motor with machineble welding rod lathe work to make size as per inner dia of bearing and polishing complete all as directed by Eng-in-Charge.
68Supply and fixing as in replacement Contactor kit for ML – 1.5 complete all as specified and directed by Eng-in-Charge.
69Supply and fixing as in replacement Contactor kit for ML – 2.0 complete all as specified and directed by Eng-in-Charge.
70Supply and fixing as in replacement contactor coil for ML-1.5 complete all as specified and directed by Eng-in-Charge.
71Supply and fixing as in replacement contactor coil for ML-2.0 complete all as specified and directed by Eng-in-Charge.
72Supply and fixing as in replacement Contractor 3pole short circuit 5 KA RMS, SYM,600V Max, Maxfuse 125A/CB 125A, 60/75 C Cu-wire only Torque-45 complete all as specified and directed by Eng-in-Charge.
73Material and labour for FRP coating to base tank of cooling tower of capacity 125 TR to prevent the leakage and corrosion and deposition of scale material etc including preparation of surface by scrubbing the inner and outer surfaces of base tank with the help of sand paper and brush and applying to coat of FRP material complate all as specified and directed by Engineer -in- charge
74Mild steel for MS work confirming to Fe-410-O or Fe-310-O as in hanges, supports chaneel, clamps etc including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of syntheic enamel paint over a coating of red oxide primer.
75Supply and fixing as in replacement Direct-on-Line (DOL) starter suitable for Three Phase, 415 Volts, 3 HP centrifugal pump set and connection by using lugs/thimbles complete all as specified and as directed.
76Supply and fixing non return valve (NRV) of size 100mm bore, cast iron body, as per IS 5312 (ISI marked), heavy duty, class 'PN-1.6', gun metal seat, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint complete all as specified and as directed including dismantling & taking out old unserviceable non return valve of 50mm bore complete all as specified and directed by Eng-in-Charge.
77Material and labour for repair to LT Panel Indoor type by disconnecting all electric connections, removal of complete internal wiring and replacing the internal wiring with & including new, PVC insulated stranded copper conductor FRLS cables of existing size but not less than 6 sqmm with proper copper lugs, thimbles, minor extras and replacing other unserviceable accessories to make the panel fully functional complete all as specified and directed by Eng-in-Charge. Note: Accessories except wiring/lugs/thimbles/minor extras directed to be replaced shall be measured and paid separately under respective items.
78Supply and fixing in replacement MCB, SPN, 32 Amps, 240 Volts, AC supply, with overlaod and short circuit protection, 'C' curve and rupturing capacity 10 kA complete all as specified and directed by Eng-in-Charge.
79Supply and fixing in replacement MCB, SPN, 40 to 63 Amps, 240 Volts, AC supply, with overlaod and short circuit protection, 'C' curve and rupturing capacity 10 kA complete all as specified and as directed.
80Supply and fixing in replacement MCB, TP ,25 to 63 Amps, 415 Volts, AC supply, with overlaod and short circuit protection, 'C' curve and rupturing capacity 10 kA complete all as specified and as directed.
81Supply and fixing in replacement MCB, 4 Pole, 63 Amps, 415 Volts, AC supply, with overlaod and short circuit protection, 'C' curve and rupturing capacity 10 kA complete all as specified and as directed.
82Material and labour welding work in repair including cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, as required, in the case of metal nexc 6mm thick complete including taking down the article and refixing in position after welding all as specified and directed by Engineer-in-Charge.
83Supplying, fixing, jointing and testing, ISI marked, heavy grade, class C, MS pipe, 150mm dia, conforming to IS: 1239-1982, including fittings such as coupling, bends, elbow and tee screwed/flanged joints, nuts&bolts, rubber packing rings, fixed on wall, hanged with ceiling through clamps, hangers, brackets, pipe supports, etc, as per the site requirement in long/short pieces complete all as specified and directed by Eng-in-Charge.
84Supplying, fixing, jointing and testing, ISI marked, heavy grade, class C, MS pipe, 100mm dia, conforming to IS: 1239-1982, including fittings such as coupling, bends, elbow and tee screwed/flanged joints, nuts&bolts, rubber packing rings, fixed on wall, hanged with ceiling through clamps, hangers, brackets, pipe supports, etc, as per the site requirement in long/short pieces complete all as specified and directed by Eng-in-Charge.
85Supplying, fixing, jointing and testing, ISI marked, heavy grade, class C, MS pipe, 80mm dia, conforming to IS: 1239-1982, including fittings such as coupling, bends, elbow and tee screwed/flanged joints, nuts&bolts, rubber packing rings, fixed on wall, hanged with ceiling through clamps, hangers, brackets, pipe supports, etc, as per the site requirement in long/short pieces complete all as specified and directed by Eng-in-Charge.
86Supplying, fixing, jointing and testing, ISI marked, heavy grade, class C, MS pipe, 65mm dia, conforming to IS: 1239-1982, including fittings such as coupling, bends, elbow and tee screwed/flanged joints, nuts&bolts, rubber packing rings, fixed on wall, hanged with ceiling through clamps, hangers, brackets, pipe supports, etc, as per the site requirement in long/short pieces complete all as specified and directed by Eng-in-Charge.
87Material and labour in replacement of crankage heater suitable for scroll compressor model No. SZ185S4RC make : Danfoss complete all as specified & directed.
88Material and labour in replacement of power contactor 45 Amp, 415volt, 4 pole including NO/NC point complete all as specified & directedMake : Schneider, Siemens, ABB , Chint , Schneider
89Supply and fix in replacement cooling tower fan blade assembly 1500mm dia with 4 nos FRP blades and 01 no aluminium hub suitable for weldon make 125TR cooling tower complete all as specified & directed.
90Supply and fix in replacement PVC fillings of size 600x300x150mm suitable for Weldon make 125TR cooling tower complete all as specified & directed.Note : Items to be procurred from OEM of cooling tower only
91Supply only cooling tower fan motor squirrel cage ,TEFC, IP-55, 3-phase, 415V, 50Hz, 960 RPM, 5 HP direct driven, extended shaft, flange mounted complete all as specified & directed.Make : Oswal/Siemens/Swing
92Supply and fix in replacement 125 TR Weldon make cooling tower fan motor FRP canopy with stands complete all as specified & directed.
93Supply fix in replacement 4 way Supply air Grill Diffusers / return air grill of extruded aluminum of size 600 mm x 150mm as per existing site matching , powder coated as specified and complete with Flush, 20mm flanges with PVC gasket, removable core type, square/rectangular as required, complete all as specified & directed.
94Supply and fix in replacement of rotaional moulded poly ethylene water storage tank (cylindrical vertical with closed top ) hoisted and fixed in position of capacity 1000 Liters with inlet/outlet valves, float Valve and full way Gate Valve of 32mm dia and drain valve of 40mm dia as required all as specified and directed.
95Material and labour for PCC 1:2:4 type B2 using 40mm grade stone aggregate as in foundation work for cooling tower or making good of disturbed surface complete all as specified and as directed by Engineer in-charge.
96Supply and fixing as in replacement of strip heaters metal enclosed with external mettalic fins 3 KW (make dasspan/striplex) installed at return air passage including thermostat complete all as specified and directed.
97Supply, installation, testing & commissioning in replacement of LT panel board, CPRI approved outdoor type, IP 66 protection, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet side covers with double door front and back hinged doors with proper locking arrangement, lifting lugs, rubber gasket on front and back to make it dust and vermin proof, powder coated including 1000 Amp rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable complete comprising of following accessories all as specified and directed by the Engr in-charge. (Note: LT panel shall be provided with mounting legs made up angle iron of size 50 x 50 x 6 mm on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed :-Note : The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item.INCOMMING: (a) MCCB, 4 pole 415 volt, Manual draw type micoprocessor based 630 Amps capacity 50KA-01 No. (b) Digital Amperemeter,digital Volt meter, digital frequency meter, digital energy meter selector switch etc - 01 No (c) LED indicating lamps three Nos (RYB)-01 Set.OUTGOING:- (a) MCCB 4 pole 415 volt, 200 Amps capacity 25 KA. -03 No. (for chiller unit -03 No) (b) MCCB 4 pole 415 volt, 160 Amps capacity 25 KA. -04 No. (for AHU ) (c) MCCB 4 pole 415 volt, 125 Amps capacity 25 KA. -02 No. (for CFU and main pump control panel )
98Supply and fixing as in replacement MCCB 630 Amps, 4 pole, 415 Volts with micro processer release with braking capacity 50 KA complete all as specified and directed
99Supply and fixing as in replacement MCCB , 4 Pole,200 Amp,25 KA,415 Volt, 50 Hz, Adjustable thermal magnetic Protection unit complete all as specified and directed.
100Supply and fixing as in replacement MCCB , 4 Pole,160 Amp,25 KA,415 Volt, 50 Hz, Adjustable thermal magnetic Protection unit complete all as specified and directed.
101Supply and fixing as in replacement MCCB , 4 Pole,125 Amp,25 KA,415 Volt, 50 Hz, Adjustable thermal magnetic Protection unit complete all as specified and directed.
102Supply and fixing as in replacement MCCB , 4 Pole,63 Amp 16 KA,415 Volt, 50 Hz, Adjustable thermal magnetic Protection unit complete all as specified and directed.
103Material and labour for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, 25 mm thickness of insulation as specified and including the following:-(a) Material and labour for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Material and labour for applying rubber based adhesive CPRX compound. (c) Material and labour for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
104S&F in replacement of perforated Hot Dipped Galvanised Iron cable tray of size 300mmx50mmx 1.2mm thick galvanised iron sheet of following size cable tray with perforation not more than 17.5% including all accessories i.e bends, coupler, cable tie, joined with connectors, suspended from the ceiling with G.I. suspenders, G.I. bolts & nuts, etc as required, complete all as specified and directed.
105For Credit Schedule refer Tender documents. The amount of Credit schedule will be deducted from total quoted amount of BOQ to arrive Contract Sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56736695
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Maintenance Of Air Conditioning And Refrigeration System Ac Plant At Af Stn Sarsawa Under Ge Af Sarsawa
Basic Detail
Tender No CWE/AF AMB/SAR-T02/2026-27
Bidding Type Tender
Location
City Saharanpur
State Uttar Pradesh
Key Dates
Publish Date 29 Jul 2026
Submission Date 19 Aug 2026
Open Date 21 Aug 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
68eb502b-c00a-4d5e-8f02-bacaafe72be3.html
BOQ_875546.xls
Tender02T.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Aug 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

68eb502b-c00a-4d5e-8f02-bacaafe72be3.html

xls

BOQ_875546.xls

pdf

Tender02T.pdf

pdf

Tendernotice_1.pdf

Disclaimer