Drinking Water Supply and Sanitation Government Departments Closing in 3 days TDR #56734682

Tender For Repairing & Replacement Of Pumping Machinery And Allied Works At P.H.No- High Lift Of Helencha Ground Water Based W/S Scheme Under Emd, Phe Dte.In 24Pgs(N).

Issued by Government Departments · Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Aug 2026
3 days left
EMD
41500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repairing & Replacement Of Pumping Machinery And Allied Works At P.H.No- High Lift Of Helencha Ground Water Based W/S Scheme Under Emd, Phe Dte.In 24Pgs(N).

BOQ

Name of Work:- Repairing & replacement of pumping machinery and allied works at P.H.No- High Lift of Helencha Ground water based W/S Scheme under EMD, PHE Dte.in 24Pgs(N).
Sl. No. Item Description
1Dismantling the existing damaged pump-motor, valves , pipes & allied from its existing position all complete.
2Supply, delivery and storage at site Lift Type 150 mm Foot valve combined with stainer as per IS : 4038 PN-0.6.(AT SUCTION HEADER )(Make - IVI/Jupiter/ Durga/other approved make)
3Supply, delivery and storage at site 125 mm dia double flanged Cast Iron manually operated non-rising spindle sluice valve generally conforming toIS:14846 PN-1.0. (AT SUCTION HEADER )(Make - IVI/Jupiter/ Durga/other approved make)
4Supply, delivery and storage at site of CI doble flanged single door swing check 125 mm dia N.R.V as per IS : 5312, Part-I, PN-1.0 . (AT DELIVERY SIDE OF PUMP)(Make - IVI/Jupiter/ Durga/other approved make)
5Supply delivery at site of 150 mm dia 5.4 mm thick MS ERW pipe as per relevant IS for suction line.
6Supply delivery at site of 125 mm dia 5.4 mm thick MS ERW pipe as per relevant IS for delivery line.
7Supply and delivery at site of horizontal split casing Centrifugal pumping machinery having capacity 100 M3/Hr. against a total head of 35 mtrs, coupled with suitable rating squirrel cage TEFC ,IE3 foot mounted motor suitable for 3 Ph, 415V± 10%, 50 Hz ,1500 rpm, continuous rating ( S1 Duty) IP-55 enclosure, with Class ‘F’ insulation suitable for ambient temperature 50ºC ( Temperature rise limited to class “B” ) Make:- Pump-Kirloskar/Mather & Platt/WPIL/Any other approved make. Motor- Crompton Greaves / Kirloskar/ KEC/ABB/Marathon/Any other approved make.[ Test Certificates, Characteristic Curve, Guarantee Certificates should be submitted at the time of delivery]
8Installation of above pump-motor set alongwith fitting fixing of valves ,pipes in new orientation on its existing position as in item no.(2 to 7) after making suitable size new foundation of pump-motor by supplying all other necessary materials and proper alignment complete as per direction of E.I.C.
9Supply, Delivery and Storage at Site of 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor wall Mounted 415 Volt MCC Panel(30HP) having following specification:-Incommer : i) FP MCCB with O/L , S/C Protection(100Amps,25KA)- 01 no. ii) Digital Ammeter -------------- 01 no. iii) Ammeter Selector Switch---------------- 01 no iv) C.T for Ammeter (100 : 5)-------------- 03 nos. v) Digital Voltmeter---------------- 01 no.
10vi) Voltmeter Selector Switch,--------01 no. vii) SP MCB for voltmeter (6 Amp) ------- 03 nos. viii)Phase Indicating Lamp ------- 03 nos. ix Voltage monitoring relay.....01No.x) Voltage trip Indicator.........01Noxi) Surge protection Device----01No. xii)TPN MCB (25A ,10Ka)....01No. xiii) Auto Phase Reversal Correction Device---- 01 no. Xiv) Logic Contactor(4A) ----01 no.
11Outgoing: i) MPCB (30-42Amps)------------- 02 no. ii) Motor Protection Relay(0.5-80)A..........02 no. iii) Contractor (40 Amp)-------------------- 04 no. iv) Contractor (32 Amp)-------------------- 02 no. v)Capacitor (10 KVAR)--------------------- 02 no. vi)Contactor for capacitor(25 Amps)----------- 02 no. vii)TP MCB for capacitor (25 Amps) --------------- 02no.
12viii)Star-Delta Timer (3-120 Sec) ----------- 02 no. ix)On-Delay timer ....02Nos x) DP MCB (6 Amp) --------- 02 no. xi)ON/OFF/Trip Indicator -------- 06 nos xii) Start/Stop Push Button--------- 04nos.
13For Chlorinator: i) TP MCB (16 Amp) -----01no. ii) Over Load Relay (1.0 - 1.4 Amp) ----01 no. iii) Contactor(9Amp) ------01 no. iv) Water Level Controller ------- 01 no. v) ON/OFF/Trip Indicator ------ 03 nos. vi)Start/Stop Push Buttom------- 02 nos.
14Installation of the above Panel on as in item no. 9 wall with complete cable connection as per direction supplying all required materials and commissioning the same as per satisfaction of E.I.C
15Supply, Delivery at site Single core 1.1 KV Grade 10 Sq. mm. PVC insulated Copper flexible Cable as per Relevant IS.NB: Cable to be supplied as per sire requirement.( Make : GLOSTER/NICCO/Polycab / Havell’s/Mescab/any other approved make)
16Laying of cable as in item no. 11 on wall/surface including S&F of MS saddles with earthing attachment in 10 SWG GI(HOT DIP) wire making holes etc. as necessary mending good damages and paint all complete.
17Finishing the end of cable by crimping method including supplying of suitable size Al. thimble, tapes, jointing materials & supplying and fixing suitable type compression gland for above cable including supply of brass gland, rubber ring etc.
18Supply fitting fixing of 150 mm dia (0 - 7 Kg/cm2) Pressure Gauge with syphon wih stop cock (Approved make)
19Supply fitting fixing of 0 - 760 mm range Vaccume gauge with suitable stop cock.
20Making priming arrangement for . High lift pump by supplying suitable size 500 litre pvc tank, pipe,sluice valve & all other necessary materials and making gland water removal arrangement by suitable size pvc pipe to carry out the work as per direction of E.I.C.
21Painting of the installation (viz. pumps,valves, pipe lines etc. by two coats of epoxy paint (colour to be decided by EIC) over a coat of primer as per direction of EIC.
22Testing, Commissioning the whole installation upto entire satisfaction of E.I.C.
23Add: GST @ 18%
24Add: LWC @ 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56734682
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 17-08-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Repairing & Replacement Of Pumping Machinery And Allied Works At P.H.No- High Lift Of Helencha Ground Water Based W/S Scheme Under Emd, Phe Dte.In 24Pgs(N).
Basic Detail
Tender No WBPHED/EE/EMD/NIET-04/2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 30 Jul 2026
Submission Date 17 Aug 2026
Open Date 20 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 41500
Exemption Not Available
Document List
BOQ_2542675.xls
cc4dfd1c-c2e1-49e6-a685-ba54174ce05c.html
Tendernotice_1 (16).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Aug 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2542675.xls

html

cc4dfd1c-c2e1-49e6-a685-ba54174ce05c.html

pdf

Tendernotice_1 (16).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders