Drinking Water Supply and Sanitation Government Departments Closing in 7 days TDR #56734678

Tender For Renovation Of Power Distribution Arrangement With Allied Works At P.H.No- High Lift Of Kola Ground Water Based W/S Scheme Under Emd, Phe Dte.In 24Pgs(N).

Issued by Government Departments · Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Aug 2026
7 days left
EMD
12000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Power Distribution Arrangement With Allied Works At P.H.No- High Lift Of Kola Ground Water Based W/S Scheme Under Emd, Phe Dte.In 24Pgs(N).

BOQ

Name of Work:- Renovation of power distribution arrangement with allied works at P.H.No- High Lift of KOLA Ground water based W/S Scheme under EMD, PHE Dte.in 24Pgs(N).
Sl. No. Item Description
1Dismantling the existing damaged main switch , Changeover , cable etc. & allied from existing position all complete & kept at site.
2Supply & delivery at site of 25 Sq. mm. 1.1 KV grade 3½ core Al. conductor armoured P.V.C. /XLPE insulated cable. NB: Cable to be supplied as per sire requirement.( Make: GLOSTER/NICCO/Polycab / Havell’s/Mescab/any other approved make)
3Supply, Delivery and Storage at Site of 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor wall Mounted 415 Volt MCC Panel( 12.5 HP) having following specification:-Incommer : i) FP MCCB with O/L , S/C Protection(63Amps,25KA)- 01 no. ii) Digital Ammeter -------------- 01 no. iii) Ammeter Selector Switch---------------- 01 no iv) C.T for Ammeter (60 : 5)-------------- 03 nos. v) Digital Voltmeter---------------- 01 no.
4vi) Voltmeter Selector Switch,--------01 no. vii) SP MCB for voltmeter (6 Amp) ------- 03 nos. viii)Phase Indicating Lamp ------- 03 nos. ix Voltage monitoring relay.....01No.x) Voltage trip Indicator.........01Noxi) Surge protection Device----01No. xii)TPN MCB (25A ,10Ka)....01No. xiii) Auto Phase Reversal Correction Device---- 01 no. Xiv) Logic Contactor(4A) ----01 no.
5Outgoing: i) MPCB (16 -20 Amps)------------- 02 no. ii) Motor Protection Relay(0.5-80)A..........02 no. iii) Contractor (32 Amp)-------------------- 04 no. iv) Contractor (25 Amp)-------------------- 02 no. v)Capacitor (4 KVAR)--------------------- 02 no. vi)Contactor for capacitor(12 Amps)----------- 02 no. vii)TP MCB for capacitor (16 Amps) --------------- 02no.
6viii)Star-Delta Timer (3-120 Sec) ----------- 02 no. ix)On-Delay timer ....02Nos x) DP MCB (6 Amp) --------- 02 no. xi)ON/OFF/Trip Indicator -------- 06 nos xii) Start/Stop Push Button--------- 04nos.
7For Chlorinator: i) TP MCB (16 Amp) -----01no. ii) Over Load Relay (1.0 - 1.4 Amp) ----01 no. iii) Contactor(9Amp) ------01 no. iv) Water Level Controller ------- 01 no. v) ON/OFF/Trip Indicator ------ 03 nos. vi)Start/Stop Push Buttom------- 02 nos.
8Installation of the above Panel on as in item no. 3 wall with complete cable connection as per direction supplying all required materials and commissioning the same as per satisfaction of E.I.C
9Supply & delivery at site of 100 Amp TPN Rewire able type switch fuse.( Make Havells/ GEC/ Standard/any other approved make)
10Supply & delivery at site of 100Amps wall mounted 4-way Bus-Bar chamber having 4nos. Copper bus-bar.( Make Havells/ L&T/ Standard/any other approved make)
11Supply & delivery at site of 100 Amp. 4 pole on load change over switch. ( Make Havells/ Standard/any other approved make)
12Fitting, fixing of main switch & bus-bar as in item no. 5 to 7 on flat iron frame/angle iron frame on wall by supplying all necessary fixing materials including welding all complete as per direction.
13Laying of cable as in item no. 2 on wall/surface including S&F of MS saddles with earthing attachment in 10 SWG GI(HOT DIP) wire making holes etc. as necessary mending good damages and paint all complete. i) 25 Sq.mm 3½ core.
14Finishing the end of cable by crimping method including supplying of suitable size Al. thimble, tapes, jointing materials & supplying and fixing suitable type compression gland for above cable including supply of brass gland, rubber ring etc. i) 25 Sq.mm 3½ core.
15Supply, Delivery at site Single core 1.1 KV Grade 6 Sq. mm. PVC insulated Copper flexible Cable as per Relevant IS.NB: Cable to be supplied as per sire requirement.( Make: GLOSTER/NICCO/Polycab / Havell’s/Mescab/any other approved make)
16Laying of cable as in item no. 13 on wall/surface including S&F of MS saddles with earthing attachment in 10 SWG GI(HOT DIP) wire making holes etc. as necessary mending good damages and paint all complete.
17Finishing the end of cable by crimping method including supplying of suitable size Al. thimble, tapes, jointing materials & supplying and fixing suitable type compression gland for above cable including supply of brass gland, rubber ring etc.
18Earthing with 50mm dia. G.I. pipe 3.64mm thick x 3Mtr.(10ft.) long and 1 x 4SWG G.I. wire(4Mtr. long) 13mm diametre x 80mm (3inch) long G.I. Bolts, double nuts, washer including S & F 15mm diametre G.I. pipe protection(1Mtr. Long) to be filled with bitumen partly below ground level to an average depth of 3.65Mtr.(12ft.) below the ground level and restoring the surface duly rammed.[This cost includes earth pit and its necessary lid making]
19Extra for treatment of soil by salt and charcoal coke for pipe electrode.
20Connecting the equipments body to earth busbar including S &F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floorwith GI saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc.
21Brick work around the earth pits, neat cement finishing, supply & fitting fixing of MS cover plates above the earth pits all complete as per satisfaction of E.I.C.
22Making internal electrification of P/House by 2 X 1.5 sq.mm. PVC cu. wire through suitable size casing for 2 nos. tube light point, 2 nos. bulb point, 2 nos. Fan point and 1 no. 5A, 3 ping plug point with earthing attachment as per approved make and brand on wall all complete as per I.E. rules and direction.
23Supply fitting fixing of 1200 mm, sweep Ceiling Fan[ Make:- Khaitan/Polar/Havell’s/Orient/CGL/any other approved make]
24Supply fitting fixing of 15watt LED tube set. [ Make:- Philips/CGL/Havell’s/Orient/CGL/any other approved make]
25Supply fitting fixing of 15watt LED Bulb. [ Make:- Philips/CGL/Havell’s/Orient/CGL/any other approved make]
26Testing, Commissioning the whole installation upto entire satisfaction of E.I.C.
27Add: GST @ 18%
28Add: LWC @ 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56734678
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 17-08-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Renovation Of Power Distribution Arrangement With Allied Works At P.H.No- High Lift Of Kola Ground Water Based W/S Scheme Under Emd, Phe Dte.In 24Pgs(N).
Basic Detail
Tender No WBPHED/EE/EMD/NIET-04/2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 30 Jul 2026
Submission Date 17 Aug 2026
Open Date 20 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 12000
Exemption Not Available
Document List
c1053d21-6667-4cf2-a9ab-7527b1fef74b.html
Tendernotice_1 (16).pdf
Tendernotice_2 (2).pdf
BOQ_2542676.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

c1053d21-6667-4cf2-a9ab-7527b1fef74b.html

pdf

Tendernotice_1 (16).pdf

pdf

Tendernotice_2 (2).pdf

xls

BOQ_2542676.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders