Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #56731240

Tender For Special Repair To Bldg Nos Top/21/137 (B Coy Living Shelter) , Top/21/139 (B Coy Chdh) And Top/21/164 (B Coy Living Shelter) Of Age B/R And Age E/M Under Ge Tenga

Issued by Statutory Bodies & Commissions/Committees · kameng, Arunachal Pradesh
Tender Value
47.90 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
2 days left
EMD
95800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kameng → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Bldg Nos Top/21/137 (B Coy Living Shelter) , Top/21/139 (B Coy Chdh) And Top/21/164 (B Coy Living Shelter) Of Age B/R And Age E/M Under Ge Tenga

BOQ

Name of Work:-
Sl. No. Item Description
1Dismantling boarding, any description, fixed in any position with nails
2M&L for Anodised aluminium frame powder coated(min thickness of powder coating 50 micron) for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
3S&F for Anodised aluminium window and ventilator shutters powder coated(min thickness of powder coating 50 micron), fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
4Supply only 5.5mm Sheet glass, ordinary quality, in squares exc 0.5 sq. m each pane as specified.
5Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings as specified.
6M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
7M&L for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
8S&F 4 mm thick ply wood, grade BWR, type BB, fixed with nails to timber frame work on ceiling surfaces.
9S&F 6 mm thick ply wood, grade BWR, type BB, fixed with nails to timber frame work on wall surfaces.
10S&F 12 mm thick prelaminated particle board,interior grade, prelaminated one side with decorative choice lamination, and other side balancing white lamanation, fixed with screw to timber frame work.
11M&L for preparation of new wooden surfaces of any description, not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
12Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
13M&L for 75mm thick Pcc type B-2, 1:2:4 (using 40mm graded stone agg) as in floors complete all as specified and directed.
14M&L for 15 mm thick Screed bed or bedding layer of cement mortar 1:4 for laying floor finishes complete all as specified.
15M&L for Joint free coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
16M&L for 75mm thick Pcc type C-2, 1:3:6 (using 40mm graded stone agg) as in plinth protection complete all as specified and directed.
17Taking down cement or cement lime plaster, any description incl racking out joints, hacking for key, scrubbing down with water etc.
18M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4 to receive wall tiles complete all as specified.
19M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
20Material and labour for preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
21Dismantling wrought iron or mild steel work of any description not otherwise provided for as specified.
22M&L for Rolled sections Fe-410 W(Gde E-250)quality B as in framing for cladding, glazing and thelike fixed with angle cleats and connecting plates, etc. complete all as specified and directed.
23M&L for preparing new steel surface of any description and applying two coat of synthetic enamel over a coat of red oxide zinc chrome primer complete on surfaces complete all as specified and directed.
24Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar .
25M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete all as specified and directed.
26M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces with CM 1:4, finished even & smooth w/o using extra cement complete all as specified.
27M&L for preparing plastered newly surface of any description and applying two coat of cement base paint on walls surface over a coat of alkali resitent primer as specified.
28Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
29M&L for 20 mm thick Screed bed or bedding layer of cement mortar 1:4 for laying floor finishes complete all as specified.
30M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
31Dismantling of CI soil, rain water pipes, cast and vent pipes of any dia, any pattern including all fittings.
32S&F PVC (SWR) pipes single socketed 75 mm bore in any length with rubber ring joints fixed to walls
33S&F PVC (SWR) bends any radius, 75 mm bore
34S&F PVC (SWR) junction single, (single T) equal or unequal with access door 75mm bore.
35Taking up or down 15 mm bore steel water tubing and connections including clfor refixing or removal to store
36S&F 15mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches.
37Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
38All as per item No. 36 here in before One 3 pin socket outlet, 6 Amps on the same board with other switches, with cables 1.5sq. mm size
39All as per item No. 36 here in before but for one 3 pin socket outlet 6 Amps three pin controlled by one switch on independent board complete all as specified directed.
40All as per item No. 36 here in before but for one 5 pin socket outlet 16 Amp and 6 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire complete all as specified.
41M&L for in replacement of Point wiring with 2.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC pipe of adequate size with all fittings and accessories) including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 2.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
42S&F Socket outlet 2 in 1, 3 pin, 5 amp flush type
43S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type
44Supply & fixing switch piano flush type (ISI marked), single pole, one way 15 Amp, 240 Volts complete all as specified & directed.
45Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed.
46Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed.
47Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, three core flexible copper conductor cable of size from ceiling rose complete all as directed.
48S&F LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connenting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as spicified and directed.
49Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. complete all as directed.
50S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbersclmaps, all fixing arrangements such as fastners, bilts, nuts washers etc all as specified and directed.
51Supply and fix sheet metal enclosures for DBs Double door when MCBs to be used 230 volts 8 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board.
52S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 V complete all as specified and directed.
53S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 V complete all as specified and directed.
54S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed cable with multistranded copper conductor 6 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipe along with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 6 sqmm earth wire and 2 Run of 6 sqmm cable shall be measured as one run.)
55Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
56Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc)
57Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC.
58Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out complete all as specified and as directed.
59Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
60Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
61M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
62Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat all as specified and directed
63Supply and laying galvanised tube light grade ISI marked of size 40 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed.
64Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 16 sqmm 2 core complete all as specified and directed
65Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers
66Supply and fix electric water heater(Geyser), storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 litre, BEE 5 star rated adjustable temprature setting 0-90 degree C complete with accessories such as safety wall, thermostate, NRV indication lamps, inlet outlet connections,air vent connections, connection pieces including all fixing arrangements such as fastners, bilts, nuts washers etc including making good disturbed wall surfaces matching with the existing surface and finishing complete all as specified and directed by Engr in charge
67S&F Stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of size 15 mm.
68S&F Bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified & as directed by engr-in-charge.
69M & L for PVC connections 15mm size with PTMT nuts of length 450mm for hot and cold water connection complete
70S&F distribution board vertical type TPN 415 Volt for fixing 4 pole MCCB, double door IP 43 protection, 4 way with copper bus bars, neutral links , earth link, earthing studs, blanking plates, interconnection between incomer MCCB and bus bar duly prewired fixed flush to wall / other surface complete all as specified and as directed.
71S & F MCCB, 04 Pole, capacity 100 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) in the existing panel with suitable connecting copper terminals at site complete all specified and directed.
72Supplying, laying, jointing & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 25 sqmm 4 core as per IS 7098 Pt-II laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as directed and specified. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56731240
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.90 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Bldg Nos Top/21/137 (B Coy Living Shelter) , Top/21/139 (B Coy Chdh) And Top/21/164 (B Coy Living Shelter) Of Age B/R And Age E/M Under Ge Tenga
Basic Detail
Tender No 8231/E8
Bidding Type Tender
Location
City kameng
State Arunachal Pradesh
Key Dates
Publish Date 29 Jul 2026
Submission Date 19 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 47.90 Lakhs
Tender Fee 500
EMD 95800
Exemption Available
Document List
8806dd27-3fc0-4372-928d-57610d829704.html
BOQ_875610.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

8806dd27-3fc0-4372-928d-57610d829704.html

xls

BOQ_875610.xls

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders