Tender For Providing Of Veh Insp Shed In 848 Fd Wksp (Area 123 X 30 Ft) Of Age B/R And Age E/M Under Ge Tenga
Tender Value
37.80 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
2 days left
EMD
75600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kameng → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Providing Of Veh Insp Shed In 848 Fd Wksp (Area 123 X 30 Ft) Of Age B/R And Age E/M Under Ge Tenga
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard / dense soil complete all as specified and directed. |
| 2 | Surface dressing n exc 15 cm deep in hard/dense soil complete all as specified and directed. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 4 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed. |
| 5 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 6 | M&L for Pre-cast cement concrete block masonry type C-1 1:3:6(20mm graded agg) in CM 1:6 with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and directed. |
| 7 | Use & waste Formwork Flat to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick(Horizontal or sloping)as specified. |
| 8 | Use & waste Formwork Flat to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter as specified and directed. |
| 9 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips as specified and directed. |
| 10 | M&L for Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips as in striupps as specified and directed. |
| 11 | M&L for RCC B1 1:2:4(20mm graded agg) Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 12 | M&L for RCC B1 1:2:4(20mm graded agg) Foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed. |
| 13 | M&L for Particle board 25mm thick medium density, flat pressed,single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and directed. |
| 14 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces,finished even & smooth w/o using extra cement in CM 1:4 complete all as specified and directed. |
| 15 | M&L for Hard core, (broken stone or boulders) broken to gauge exc 63 mm and n exc 100mm deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed. |
| 16 | M&L for 100mm thick Cement concrete type C-2, 1:3:6 (using 40mm graded agg) as in foundations, filling and mass concrete |
| 17 | M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 18 | M&L for PCC 1:2:4 type B-2 using (40 mm graded stone aggregate) in walls orretaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 19 | M&L for Cement concrete B2 1:2:4(40mm graded agg) in foundations,filling and mass concrete complete all as specified and directed. |
| 20 | M&L for Providing, cement concrete B1 1:2:4(20mm graded agg) in roof kerbs or mud stops, rounded or chamfered on edges. |
| 21 | M&L for 75mm thick Pcc type B-2, 1:2:4 (using 40mm graded stone agg) as in plinth protection finishing even and smooth w/o using extra cement complete all as specified and directed. |
| 22 | S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete as specified. |
| 23 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed. |
| 24 | S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed. |
| 25 | M&L for preparation of newly steel surface of any description, over 10cm in width or girth,not otherwise described with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 26 | M&L for preparation of newly plastered surface and applying with two coat of cement base paint over a coat of chalk whitning primer on walls complete all as specified and directed. |
| 27 | Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 28 | All as per item No. 27 here in before One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5sq. mm size |
| 29 | All as per item No. 27 here in before but for one 5 pin socket outlet 15 Amp and 5 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm complete all as specified. |
| 30 | S&F Socket outlet 2 in 1, 3 pin, 5 amp flush type |
| 31 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type |
| 32 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 15 Amp, 240 Volts complete all as specified & directed. |
| 33 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed. |
| 34 | M&L for new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 70 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including clamps, nut, bolt & any angle required at site for fixing complete as specified and directed. |
| 35 | S&F in distribution board vertical type TPN 415 Volt for fixing MCB/Isolator as incomer, double door IP 43 protection, 4 way with copper bus bars, neutral links , earth link, earthing studs, blanking plates, interconnection between incomer MCB and bus bar duly prewired fixed flush to wall / other surface complete all as specified and as directed. |
| 36 | S&F MCB TPN having braking capacity 10KA, 63 Amps, 415 V complete all as specified and directed. |
| 37 | S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 V complete all as specified and directed. |
| 38 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 39 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 35 Sqmm 3.5 core complete all as specified and directed. |
| 40 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out complete all as specified and as directed. |
| 41 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning. |
| 42 | Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender