Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #56727507

Tender For Special Repair To Bldg No T-118 Of Is Det And Provn Of Pathway With Interlocking Tiles At Certain Places Along With Provn Of Gate Under Aor Of Ge 871 Ews.

Issued by Statutory Bodies & Commissions/Committees · Chamoli, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Aug 2026
17 days left
EMD
70300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chamoli → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Bldg No T-118 Of Is Det And Provn Of Pathway With Interlocking Tiles At Certain Places Along With Provn Of Gate Under Aor Of Ge 871 Ews.

BOQ

Name of Work:- SPECIAL REPAIR TO BLDG NO T-118 OF IS DET AND PROVN OF PATHWAY WITH INTERLOCKING TILES AT CERTAIN PLACES ALONG WITH PROVN OF GATE UNDER AOR OF GE 871 EWS.
Sl. No. Item Description
1SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS.
2Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed.
3Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed.
4Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed.
5Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified and as directed.
6Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified and as directed.
7Dismantling timber scantlings 40 Sqcm and over in section, unframed work, in any position, complete all as specified and as directed.
8Excavation in post holes (or similar holes) in any type of soil, each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed
9Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation filling, complete all as specified and as directed.
10Rolled mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS:1161-1979 grade St.-240, complete all as specified and as directed.
11Rolled mild steel in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.confirming to Fe 410-W (Gde- E- 250) quality- A, complete all as specified and as directed.
12Brickwork with fly ash modular bricks, straight or curved on plan exceeding 6.0 mtr mean radius built in cement mortar 1:6, complete all as specified and as directed.
13Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 75mm thick, as in plinth protection, finish even and smooth without using extra cement, complete all as specified and as directed.
14Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 100mm thick, as in sub base, finish even and smooth without using extra cement, complete all as specified and as directed.
15Plain cement concrete M-15(1:2:4), type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, 25mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed.
16Chequered cement concrete coloured tiles, pre-polished, size 200mmx200mmx20/25mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over 20mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed.
17Non-skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed.
18Granite (of any type) work (table rubbed and polished), 20mm thick, as in cooking plateform, steps, jambs, pillars, window cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, and including laid over screed bed or bedding layer 20mm thick in cement mortar 1:6, complete all as specified and as directed.
19Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar work including polishing the edges, complete all as specified and as directed.
20Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed.
21Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement) on external surfaces including mixing water proofing compound @ 200ml per 50 Kg of cement content, complete all as specified and as directed.Note: Water proofing compound shall be measured and paid separately under respective item of BOQ.
22Supply only liquid water proofing compound, complete all as specified and as directed.
23Preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion and including over one coat of chalk whiting to prepare the surface even and smooth, complete all as specified and as directed.
24Preparation of new plastered surfaces of walls and applying two coats of cement paint over one coat of priming plastered and other surfaces with alkali resistant priming paintlime wash, complete all as specified and as directed.
25Pre-painted galvalume aluminium zinc coating galvanised iron based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specifed and directed.
26Pre-painted galvalume aluminium zinc coating galvanised iron based plain steel sheet 0.80mm of any colour having tensile strength of 550Mpa as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), fixed with self tapping screws complete all as specifed and directed.
27Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed.
28Galvanised iron frame work for seamless ceiling comprising of galvanised iron perimeter channnel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.90mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at appro 900mm centre to centre with galvanised iron cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.20mtrs length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.50mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including hangers 6.0mm dia galvanised iron (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of galvanised iron flat 40mmx3mm size 60mm long and expansion hold fasteners 12.50mm dia. 40mm long, complete all as specified and as directed.
29Providing and fixing everest board 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, grid size 595x595mm, for false ceiling all as specified, complete all as specified and as directed.
30Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and as directed.
31Powder coated (minimum thickness of powder coating 50 micron), anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and as directed.
32Anodised aluminium powder coated of any colour (Thickness or powder coating not less than 50 micron), window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 Nos.) suitable handle (1 No.), screws etc, complete all as specified and as directed.
33Sheet glass, 4.0mm thick, tinted, ordinary quality and glazing with oil putty size not exceeding 0.50 Sqm in each pane, fixing in square or any size, complete all as specified and as directed.
34Toughened glass, 10mm thick, as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required, having antique finish including stainless steel handles, locking arrangements and necessary fittings/ accessories, complete all as specified and as directed.Note: size and shape of handles will be approved by Garrison Engineer.
35Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed.
36Mortice lock, brass, vertical type, size 100 mm, 4-lever, suitable for aluminium door, complete all as specified and as directed.
37Curtain rod, 20mm dia, mild steel, fancy type, any colour coated or chromium plated with fixing and inlcuing end knobs, fixing brackets, stops, round rings to hold the curtain, fixing with wall plugs and screws, complete all as specified and as directed.
38Door closer hydraulically regulated, designation No. 2, universal type, Aluminium (extruded section body), suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed, complete all as specified and as directed.
39Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed.
40PVC sheet fillet 5mm thick of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and as directed.
41Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and as directed.
42Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in Hard/Dense soil, complete all as specified and as directed.
43Hardcore of broken stone or boulders gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and as directed.
44Plain cement concrete M-7.50(1:4:8), type D-1 (using 20mm graded crushed stone aggregate), 100mm thick, as in sub base, finish even and smooth without using extra cement, complete all as specified and as directed.
45Machine pressed precast concrete interlocking paver block 60mm thick, M-35 Grade any shape and size casted in plastic moulds and compacted on vibratory table confirming to IS: 15658-2006 with grey cement and pigment, laid over 25mm thick sand cushioning, complete all as specified and directed.
46Providing and laying at or near ground level factory made kerb stone of precast plain cement concrete, conforming to M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and as directed.
47Removing excavated soil not exceeding 50mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and as directed.
48Dismantling structural steel work including doors, gates but excluding framed truss etc, complete all as specified and as directed.
49Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition), including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed.
50Preparation of new or previously untreated surfaces of concrete, brick, stone, etc., exceeding 10cm in width or girth of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed.
51Dismantaling of brickwork or stone/ boulder masonry, including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar or cement lime mortar of any description, complete all as specified and as directed.
52Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, any type of soil, complete all as specified and as directed.
53Plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation filling, complete all as specified and as directed.
54Reinforced cement concrete, design mix M-25 (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc and mass concrete, complete all as specified and as directed.
55Reinforced cement concrete, design mix M-25 (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts, complete all as specified and as directed.
56Formwork, use and waste type, as in sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to get fair finish surfaces of concrete, complete all as specified and as directed.
57Formwork, use and waste type, as in to sides of pillars, posts, struts, piers, columns and stanchions, to get fair finish surfaces of concrete, complete all as specified and as directed.
58Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
59Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
60Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, any type of soil, complete all as specified and as directed.
61Removing excavated materials exceeding 250mtrs but not exceeding 500mtrs and depositing where directed at a level not exceeding 1.50 metres above the starting point, complete all as specified and as directed.
62Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, conforming to Fe-410-W (Gde E- 250) quality-B, complete all as specified and as directed.
63Mild steel, plain, black sheet 0.63mm thick, in covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required
64Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed.
6540mm thick sand stone slabs polished, set and jointed in cement and stone dust mortar 1:3 and pointed in cement mixed with approved pigment to match, omplete all as specified and as directed.
66SCHEDULE 'A' PART-II : BOQ OF WORKS FOR E/M WORKS.
67Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed. Please Enable Macros to View BoQ information
68Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56727507
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 18-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Bldg No T-118 Of Is Det And Provn Of Pathway With Interlocking Tiles At Certain Places Along With Provn Of Gate Under Aor Of Ge 871 Ews.
Basic Detail
Tender No 8151/E8
Bidding Type Tender
Location
City Chamoli
State Uttarakhand
Key Dates
Publish Date 29 Jul 2026
Submission Date 18 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 70300
Exemption Available
Document List
252647c8-348f-4faf-9312-ae596875a7d5.html
BOQ_875554.xls
E-Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

252647c8-348f-4faf-9312-ae596875a7d5.html

xls

BOQ_875554.xls

pdf

E-Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail