Housing Urban and Rular Development Local Bodies Closing in 6 days TDR #56727296

Tender For maintenance of Various Colonies Under Nazul A/C-Ii ,Dwarka Zone. Sh:- Running Maintenance And Operation Of 82.5 Kva D.G. Set, Submersible Pump Sets, I.E.I And Compound Lighting & Repairing And Servicing Of Desert Cooler, Water Cooler And A

Issued by Local Bodies · Delhi, Delhi
Tender Value
26.86 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
6 days left
EMD
53737
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for maintenance of Various Colonies Under Nazul A/C-Ii ,Dwarka Zone. Sh:- Running Maintenance And Operation Of 82.5 Kva D.G. Set, Submersible Pump Sets, I.E.I And Compound Lighting & Repairing And Servicing Of Desert Cooler, Water Cooler And Air Conditioner At Office Complex Central Nursery, Sector-5,And Dda Lm Office Sector -6, Dwarka.

BOQ

Name of Work:- M/o various colonies under nazul A/c-II ,Dwarka zone. SH:- Running Maintenance and Operation of 82.5 KVA D.G. set, Submersible pump sets, I.E.I and compound lighting & Repairing and servicing of desert cooler, water cooler and air conditioner at office complex Central Nursery, Sector-5,and DDA LM office sector -6, Dwarka.
Sl. No. Item Description
1Running Maintenance and Operation of submersible pump set and D.G. set, compound lighting, internal electrification and other electric installtions as per inventory, terms & conditions attached.
2Supplying of following electrical accessories suitable for 220 volt A.C. supply i/c connections, testing etc as reqd.a) SP MCB- 6 to 32 Amp.
3b) DP MCB- 6 to 32 Amp.
4c) FP MCB -63 Amp.
5d) Condensor 2.5 mfd for ceiling fans
6e) Two module Stepped type electronic fan regulator
7f)5/6 amps switch modular
8g)3 pin 5/6 A socket outlet modular
9h)15/16 A switch modular
10i)6 pin 15/16 A socket outlet modular
11Supply, Installation, testing & commissioning of LT panel(Double door), fabricated in complartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, doors of 2 mm thick sheet & 3 mm thick for glands plates i/c cleaning and finishing complete with 9 tank process for powder coating(minimum 50-70 micron) of approved shade & colour, short circuit withstand capacity of 36 KA for 1 Sec., bottom base channel of MS Section not less than 100 mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common aluminium earth bar of size 50mm x 10 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 Sqmm. FRLS PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half having knock outs for cable glands of required size, EP DM gaskets of suitable shape & size at doors /windows /covers /joints to make the panel dust & vermin proof, DMC/SMC bus bar of high conductivity,DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz AC supply system and with 20% spare space, lifting hooks & suitable lighting shall also be provided in panels. A) Section-I (Incomer) 1) 320A 4P 36KA MCCB with Thermomagnetic Release -01 No.2) Extended Rotary Handle DN3B-1 No. 3)Multi Function Meter(A,V,F,PF,KW,KVA,KWH,KVAH) CL-1.0 LED Type-- 1 No. 4) Current Transformer 300/5A CL-1.0 15VA Resin Cast Type --3 Nos. 5) 3Phase Digital Ammeter and Voltmeter CL-1.0 LED Type-2 Nos. 6) Ammeter , voltmeter & auto manual Selector Switch- 3 Nos. 7) Indication Lamps LED Type 22.5MM for 3 Phase, ON (Red), OFF (Green) & TRIP (Amber)-6 Nos. 8) Control MCB 6Amp Single pole 10KA MCB- 1 No. 9) Section-II, BUS BAR Section 400 Amp aluminium BUS BAR electrolytic grade B) Section-II (Outgoing) 1) 160 A FP 36KA MCCB with Thermal Magnetic Based Release (O/L & S/C) with Extended Rotary Handle - 9 Nos.
12Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumenmaintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified ratingand Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup forall testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)18- 22 watt
13Supplying and Replacement of 300 mm sweep extra size metallic exhaust fan i/c connection, testing etc complete as reqdi/c rebate .
14Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, remote(preferably mobile app based) for speed control and all remainingaccessories including safety pin, nut bolts, washers, temperature rise=75degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fanSupply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min(Minimum
15Supplying and Drawing of following sizes of FLRS PVC insulated copper conductor single core cable (multi stranded) of 1.1 KV grade i/c connection & testing etc as reqd.a) 1 x 1.5 sq.mm
16Rewinding of 1200 mm size ceiling fan i/c change of ball bearing, bush i/c dismentaling & refixing the same, connection, testing etc as reqd i/c rebate for dismantle material.
17Lifting of submersible pump set along with flanged G.I. pipe from the deep bore well i/c dismantling of sub. Cable, G.I. pipe, flange and delivery line etc as reqd.
18Lowering of submersible pump set along with flanged G.I. pipe into the deep borewell i/c connection of flanged, G.I. pipe, delivery line, water proof jointing of sub. Cable i.c nuts, bolts, washers, rubber insertion, testing & commissioning etc as reqd.
19Servicing of 82.5 KVA D.G. set (Kirloskar make) i/c S/R of following parts/accessories, cartage testing on load etc complete as reqd. (Servicing of D.G. set has to be got done through authorised dealer of OEM)i) Oil filter --- 1 No.ii) Diesel filter (pre-micro)--- 1 setiii) Air cleaner elements --- 1 No.iv) Coolant ---- 5 ltr.v) Engine Oil ,vi) Labour charges for servicing, functioning and testing--- 1 jobvii) Radiator cleaning charges --- 1 job i/c removal & refixing
20Supplying of following sizes of XLPE Al. conductor armoured power cable of 1.1 KV grade i/c connection & testing etc as reqd.a) 4c x 50 sq.mm.
21b) 2c x 25 sq.mm.
22Laying of one no. PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground i/c excavation, sand cushioning, protective covering and refilling the trench etc as reqd.i) upto 35 sq. mm
23ii) Above 35 sq. mm and upto 95 sq.mm
24Supplying and Replacement of pump set suitable for 18”/20” sweep desert coolers with 1.5 mtr lift i/c dismantling, refixing, connection, testing etc. as required
25Supplying and Replacement of wood wool pads set with Jali suitable for 18”/20” sweep desert coolers i/c removing of old pads & binding of new pads & Jali with binding wire etc. Complete as required
26Supplying and Replacement of 3 Core (0.75 Sq mm) PVC insulated , PVC sheathed copper conductor flexible circular cable in desert coolers i/c connection testing etc. complete as required.
27Supplying and Replacement of 5/6 Amp, 3 pin plug top for the existing desert coolers i/c connection testing etc. Complete as required i/c rebate for dismantled material.
28Supplying and fixing of 3 core copper readymade lead with 5/6 Amp, 3 pin plug top for the existing desert coolers i/c connection testing etc. Complete as required.
29Supplying and Replacement 4 MFD Capacitor for the existing desert coolers i/c connection testing etc. Complete as required i/c rebate for dismantled material .
30Supplying and Replacement of 18\\" x 18\\" and 35\\" height desert cooler body having water tank made out of 20 SWG MS sheet with front grill, openable type side covers made out not less than 24 SWG suitable for 18\\"/20\\" sweep dia motor, selector switch, front grill one set wooden wool pads, 1/2 \\" distribution pipe, one plug top 15 amp and 3 core round wire 1.5 sq.mm.
31PVC flexible pipe
32PVC distributor
33Supplying and Replacement of new cooler motor kit 220 V AC suitable for 18”/20” sweep desert coolers in the existing/new coolers body i/c connection testing & commissioning etc. as required i/c rebate for dismantled material.
34Painting of desert coolers of 18”/20” sweep i/c supplying of enamel paint, primer, emery paper, old dhoti etc for cleaning, painting & refixing the same at existing location etc. complete as required.
35Servicing of water cooler 120/150 ltr. Per hour capacity i/c cleaning of base plate/hose plate with chemical, cleaning of water tank, checking of condenser coil & washing & cleaning of water tank, oiling/greasing of fan motor & reinstallation in the same position/location, testing etc. complete as required.
36Servicing of split / Window type A.C. of 1.5 ton capacity i/c cleaning with chemical of condenser coil, evaporation coil, lubricating and replacement of air filter pads, reinstallation of AC in the same position testing etc. as required
37Supplying and Charging of Refrigerant Gas of Split type A.C./Window type of 1.5 Ton capacity i/c connection, testing & commissioning etc. as required.
38Supplying and Replacement of the following items in the existing body i/c labour etc. as required i/c rebate for dismantled material.i) Fan motor blade Set. 18”/20” (M.S.)
39Supplying & Replacement of M.S leg arm 4 pcs. In the existing body i/c labour charge ,nut bolts, washer complete etc as required.
40Servicing of RO of vardhman make with replacment of all filter (all filter are capable to maintain upto 3 Month ) with associated parts as reqd. at site Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56727296
AUTHORITY Local Bodies
TENDER VALUE 26.86 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Various Colonies Under Nazul A/C-Ii ,Dwarka Zone. Sh:- Running Maintenance And Operation Of 82.5 Kva D.G. Set, Submersible Pump Sets, I.E.I And Compound Lighting & Repairing And Servicing Of Desert Cooler, Water Cooler And Air Conditioner At Office Complex Central Nursery, Sector-5,And Dda Lm Office Sector -6, Dwarka.
Basic Detail
Tender No 16/EE/ELD-5/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 29 Jul 2026
Submission Date 05 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 26.86 Lakhs
Tender Fee Ref. Documents
EMD 53737
Exemption Not Available
Document List
18a1b995-a9a8-4691-98d3-84fbf4aaa104.html
BOQ_966503.xls
NIT16PDF.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

18a1b995-a9a8-4691-98d3-84fbf4aaa104.html

xls

BOQ_966503.xls

pdf

NIT16PDF.pdf

pdf

Tendernotice_1.pdf

Disclaimer