Civil Aviation Boards / Undertakings / PSU Closing in 19 days TDR #56726896

Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - Annual Operation Maintenance Of Electrical Mechanical Installations In Integrated Operational Offices Building And 11 Kv Substation And Allied Works At Mumbai (2026-28); As Per Bid / Te

Issued by Boards / Undertakings / PSU · Mumbai Suburban, Maharashtra
Tender Value
2.16 Crore
Estimated cost
Bid Submission
19 Aug 2026
19 days left
EMD
6.49 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - Annual Operation Maintenance Of Electrical Mechanical Installations In Integrated Operational Offices Building And 11 Kv Substation And Allied Works At Mumbai (2026-28); As Per Bid / Tender Document And.. - Operation And Maintenance Of Electrical & Mechanical Installations, Internal & External Ei Such As Light Fixtures, Fans, Light & Power Points, Lt Panels, Solar Street Lightning, Etc. By Carrying Out Operation, Repair, Maintenance, Attending To Complaints / Faults / Breakdowns And Taking Rectification Action, Ensuring Serviceability / Satisfactory Working Condition Of The Systems Installed In The Operational Offices Building I/C Preventive Maintenance, Maintenance Of Records / Documentation Etc. By Deploying Qualified Manpower In Two Shifts & General Shift (Each Shift Of Eight Hours) On All Working Days Including Sunday & Holidays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Operation And Maintenance Of Electrical & Mechanical Installations, Ht/Lt Panels, Synchronising Panel Of Dg Sets Etc. By Carrying Out Operation, Repair, Maintenance, Attending To Complaints / Faults / Breakdowns And Taking Rectification Action, Ensuring Serviceability / Satisfactory Working Condition Of The Systems Installed In The Substation I/C Preventive Maintenance, Maintenance Of Records / Documentation Etc. By Deploying Qualified Manpower In Three Shifts & General Shift (Each Shift Of Eight Hours) On All Working Days Including Sunday & Holidays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Operation Of 3 X 275Tr Water Cooled Screw Chillers Of Hvac System & Building Management System And Associated Equipments / Installations Viz, Chilled Water Pumps And Condensor Water Pumps, Cooling Towers, Ahus, Make-Up Water Tank, Expansion Tank, Hvac Panels Etc. Installed In The Operational Offices Building By Carrying Out Day To Day Operation And Maintaining Records / Documentation Etc. By Deploying Qualified Manpower In 2 Shifts (Each Shift Of Eight Hours) On All Working Days, Holidays & Excluding Sundays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Operation And Maintenance Of Water Pumping System Viz, Monoblock Pumps, Dewatering Pumps, Sewage Pumps, Dewatering Diesel Pump Etc. By Carrying Out Operation, Repair, Maintenance, Attending To Complaints / Faults / Breakdowns And Taking Rectification Action, Ensuring Serviceability / Satisfactory Working Condition Of The Systems Installed In The Operational Offices Building I/C Preventive Maintenance, Maintenance Of Records / Documentation Etc. By Deploying Qualified Manpower In In 2 Shifts (Each Shift Of Eight Hours) On All Working Days, Holidays & Excluding Sundays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Comprehensive Annual Maintenance Contract ( Camc) Of Façade Cleaning System Including Regular Maintenance Of Cradle, Motor, Winches, Gear Box, Rope Wires, Safety Device Etc. The Camc Includes Repairing Of Electric Control Box, Electric Switch Gear, Electric Motor , Gear Box, Winches, Checking Of Nuts Bolts, Wire Ropes, Replacement Of All Components Etc Complete As Required For Smooth And Trouble Free Operation Of Entire System . , Servicing And Testing Of Following 11 Kv Ht Panel Including Overhauling/Servicing Of Vcbs From Oem/Oem Authorised Agency, Of Following Ratings, Maintainance Of Complete Ht Panel Including Servicing & Testing Of Ct & Pt, Checking All Operational Mechanisms, Functions, Tripping Actions, Calibration Of Protective Relays & Testing With Secondary Current Injection Technique, Carrying Preventive Maintenance & Attending Breakdown Calls And And Submitting The Test Reports Accordingly Etc.Complete As Required. For Ioobincomer Panel:-630A, Tp Vcb :- 01 Nosoutgoing Panel:-630A, Tp Vcb :- 03 Nosmake & Model : Schneider & Hvx-X Type(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Servicing & Testing Of Following 11/0.433 Kv, Dry Type Cast Resin Transformers Of 1500 Kva, Volt Make By Carrying Out Preventive Maintenance Activity Of Transformer As Per Oem Recommendations To Keep The Transformer In Serviceable Condition. Work Includes Opening The Complete Encloser, Bus Bars, Ht & Lt Side Boxes, Cable Etc. Checking Of All The Safety Equipments, Cleaning, Servicing & Testing And Submission Of Service Reports Accordingly After Completion Of The Work As Per The Requirement.(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Servicing & Testing Of Following 11/0.433 Kv, Dry Type Cast Resin Transformers Of 1000 Kva, Kirloskar Make By Carrying Out Preventive Maintenance Activity Of Transformer As Per Oem Recommendations To Keep The Transformer In Serviceable Condition. Work Includes Opening The Complete Enclouser, Bus Bars, Ht & Lt Side Boxes, Cable Etc. Checking Of All The Safety Equipments, Cleaning, Servicing & Testing And Submission Of Service Reports Accordingly After Completion Of The Work As Per The Requirement.(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Overhauling /Servicing Of Following Schneider Make 415V Electrical Acbs From Oem/Oem Authorised Agency Integrated In Main Hvac Mcc Panel Including Checking All Operational Mechanisms, Functions, Positions, Tripping Actions As Per Oem Guidelines & Submitting Test Reports Accordingly Etc.Complete As Required. 1250 A, Fp Acb:- 03 Nos.800 A Fp Acb:- 04 Nos.(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Repair Of 10 To 15 Hp Submersible/ Monoblock Pump Including , Lifting And Lowering Of Pump From The Sump ( Approx 3 Lac Liter), Transportation And Copper Rewinding , Replacement Of Bearing, Seal Etc. Complete As Required. , Repair Of Up To10 Hp Submersible/Monoblock Pump Including , Lifting And Lowering Of Pump From The Sump ( Approx 40000 Liter), Transportation And Copper Rewinding , Replacement Of Bearing, Seal Etc. Complete As Required. , Repair Of 2X2 Ceiling Mounted Led Panel Lights Including Supply Of Drivers, Leds Etc Complete As Required. , Repair Of 36 W, 1X4 Ceiling Mounted Led Panel Lights Including Supply Of Drivers, Leds Etc Complete As Required. , Repair Of 25W/35W/40W Post Top Led L S Including Supply Of Drivers, Leds Etc Complete As Required. , Repair Of 70 W Led Street Lights Including Supply Of Drivers, Leds Etc Complete As Required. , Location And Finding Of Fault In Underground Lt Cable By Pin Pointing Method Etc Complete As Required. , Providing And Fixing Of Led Type Fixtures (Minimum 80 Led Lights Per Day) For Façade Lighting With Colour Changing Module On Rental Basis For Illuminating The Integrated Operational Offices Building, Rhq, Wr, Mumbai On Front Side Of The Building Replicating National Flag (Tri-Colours And Ashok Chakra) For 2 Days Including Providing Lighting Accessories, Manpower, Transportation Of Material To & Fro Complete Etc. As Required For Independence Day & Republic Day, Or As An When Required. , Provision Of 1.5 Tr Split Air Conditioners On Hiring Basis, Including Sitc, Transportation, Dismantling And Taken Back Complete As Required. , Provision Of 2 Tr Split Air Conditioners On Hiring Basis, Including Sitc, Transportation, Dismantling And Taken Back Complete As Required.

BOQ

Sl. No. Item TitleItem Description
1Operation and Maintenance of Electrical & Mechanical installations, Internal & External EI such as Light fixtures, fans, light & power points, LT panels, solar street lightning, etc. by carrying out operation, repair, maintenance, attending to complaints / faults / breakdowns and taking rectification action, ensuring serviceability / satisfactory working condition of the systems installed in the Operational Offices Building i/c preventive maintenance, maintenance of records / documentation etc. by deploying qualified manpower in two shifts & General shift (each shift of eight hours) on all working days including Sunday & Holidays as per special conditions of contract & additional special conditions of contract.Operation and Maintenance of Electrical & Mechanical installations, Internal & External EI such as Light fixtures, fans, light & power points, LT panels, solar street lightning, etc. by carrying out operation, repair, maintenance, attending to complaints / faults / breakdowns and taking rectification action, ensuring serviceability / satisfactory working condition of the systems installed in the Operational Offices Building i/c preventive maintenance, maintenance of records / documentation etc. by deploying qualified manpower in two shifts & General shift (each shift of eight hours) on all working days including Sunday & Holidays as per special conditions of contract & additional special conditions of contract.
2Operation and Maintenance of Electrical & Mechanical installations, HT/LT panels, Synchronising panel of DG sets etc. by carrying out operation, repair, maintenance, attending to complaints / faults / breakdowns and taking rectification action, ensuring serviceability / satisfactory working condition of the systems installed in the substation i/c preventive maintenance, maintenance of records / documentation etc. by deploying qualified manpower in three shifts & General shift (each shift of eight hours) on all working days including Sunday & Holidays as per special conditions of contract & additional special conditions of contract.Operation and Maintenance of Electrical & Mechanical installations, HT/LT panels, Synchronising panel of DG sets etc. by carrying out operation, repair, maintenance, attending to complaints / faults / breakdowns and taking rectification action, ensuring serviceability / satisfactory working condition of the systems installed in the substation i/c preventive maintenance, maintenance of records / documentation etc. by deploying qualified manpower in three shifts & General shift (each shift of eight hours) on all working days including Sunday & Holidays as per special conditions of contract & additional special conditions of contract.
3Operation of 3 x 275TR water cooled screw chillers of HVAC system & Building management system and associated equipments / installations viz, chilled water pumps and condensor water pumps, cooling towers, AHUs, make-up water tank, expansion tank, HVAC panels etc. installed in the Operational Offices Building by carrying out day to day operation and maintaining records / documentation etc. by deploying qualified manpower in 2 shifts (each shift of eight hours) on all working days, Holidays & excluding sundays as per special conditions of contract & additional special conditions of contract.Operation of 3 x 275TR water cooled screw chillers of HVAC system & Building management system and associated equipments / installations viz, chilled water pumps and condensor water pumps, cooling towers, AHUs, make-up water tank, expansion tank, HVAC panels etc. installed in the Operational Offices Building by carrying out day to day operation and maintaining records / documentation etc. by deploying qualified manpower in 2 shifts (each shift of eight hours) on all working days, Holidays & excluding sundays as per special conditions of contract & additional special conditions of contract.
4Operation and Maintenance of Water pumping system viz, Monoblock pumps, Dewatering pumps, sewage pumps, dewatering diesel pump etc. by carrying out operation, repair, maintenance, attending to complaints / faults / breakdowns and taking rectification action, ensuring serviceability / satisfactory working condition of the systems installed in the Operational Offices Building i/c preventive maintenance, maintenance of records / documentation etc. by deploying qualified manpower in in 2 shifts (each shift of eight hours) on all working days, Holidays & excluding sundays as per special conditions of contract & additional special conditions of contract.Operation and Maintenance of Water pumping system viz, Monoblock pumps, Dewatering pumps, sewage pumps, dewatering diesel pump etc. by carrying out operation, repair, maintenance, attending to complaints / faults / breakdowns and taking rectification action, ensuring serviceability / satisfactory working condition of the systems installed in the Operational Offices Building i/c preventive maintenance, maintenance of records / documentation etc. by deploying qualified manpower in in 2 shifts (each shift of eight hours) on all working days, Holidays & excluding sundays as per special conditions of contract & additional special conditions of contract.
5Comprehensive Annual Maintenance Contract ( CAMC) of façade cleaning system including regular maintenance of cradle, motor, winches, gear box, rope wires, safety device etc. The CAMC includes repairing of electric control box, electric switch gear, electric motor , gear box, winches, checking of nuts bolts, wire ropes, replacement of all components etc complete as required for smooth and trouble free operation of entire system .Comprehensive Annual Maintenance Contract ( CAMC) of façade cleaning system including regular maintenance of cradle, motor, winches, gear box, rope wires, safety device etc. The CAMC includes repairing of electric control box, electric switch gear, electric motor , gear box, winches, checking of nuts bolts, wire ropes, replacement of all components etc complete as required for smooth and trouble free operation of entire system .
6Servicing and testing of following 11 KV HT Panel including Overhauling/Servicing of VCBs from OEM/OEM Authorised Agency, of following ratings, maintainance of complete HT panel including servicing & testing of CT & PT, checking all operational mechanisms, functions, tripping actions, calibration of protective relays & testing with secondary current injection technique, carrying preventive maintenance & attending breakdown calls and and submitting the test reports accordingly etc.complete as required. For IOOBIncomer Panel:-630A, TP VCB :- 01 NosOutgoing Panel:-630A, TP VCB :- 03 NosMake & Model : Schneider & HVX-X Type(Any emergency breakdown visit shall be attended free of cost)Servicing and testing of following 11 KV HT Panel including Overhauling/Servicing of VCBs from OEM/OEM Authorised Agency, of following ratings, maintainance of complete HT panel including servicing & testing of CT & PT, checking all operational mechanisms, functions, tripping actions, calibration of protective relays & testing with secondary current injection technique, carrying preventive maintenance & attending breakdown calls and and submitting the test reports accordingly etc.complete as required. For IOOBIncomer Panel:-630A, TP VCB :- 01 NosOutgoing Panel:-630A, TP VCB :- 03 NosMake & Model : Schneider & HVX-X Type(Any emergency breakdown visit shall be attended free of cost)
7Servicing & Testing of following 11/0.433 KV, Dry type cast resin transformers of 1500 KVA, Voltamp Make by carrying out preventive maintenance activity of transformer as per OEM recommendations to keep the transformer in serviceable condition. Work includes opening the complete encloser, bus bars, HT & LT side boxes, cable etc. checking of all the safety equipment’s, cleaning, servicing & testing and submission of service reports accordingly after completion of the work as per the requirement.(Any emergency breakdown visit shall be attended free of cost)Servicing & Testing of following 11/0.433 KV, Dry type cast resin transformers of 1500 KVA, Voltamp Make by carrying out preventive maintenance activity of transformer as per OEM recommendations to keep the transformer in serviceable condition. Work includes opening the complete encloser, bus bars, HT & LT side boxes, cable etc. checking of all the safety equipment’s, cleaning, servicing & testing and submission of service reports accordingly after completion of the work as per the requirement.(Any emergency breakdown visit shall be attended free of cost)
8Servicing & Testing of following 11/0.433 KV, Dry type cast resin transformers of 1000 KVA, Kirloskar Make by carrying out preventive maintenance activity of transformer as per OEM recommendations to keep the transformer in serviceable condition. Work includes opening the complete enclouser, bus bars, HT & LT side boxes, cable etc. checking of all the safety equipment’s, cleaning, servicing & Testing and submission of service reports accordingly after completion of the work as per the requirement.(Any emergency breakdown visit shall be attended free of cost)Servicing & Testing of following 11/0.433 KV, Dry type cast resin transformers of 1000 KVA, Kirloskar Make by carrying out preventive maintenance activity of transformer as per OEM recommendations to keep the transformer in serviceable condition. Work includes opening the complete enclouser, bus bars, HT & LT side boxes, cable etc. checking of all the safety equipment’s, cleaning, servicing & Testing and submission of service reports accordingly after completion of the work as per the requirement.(Any emergency breakdown visit shall be attended free of cost)
9Overhauling /servicing of following Schneider make 415V electrical ACBs from OEM/OEM Authorised Agency integrated in Main HVAC MCC Panel including checking all operational mechanisms, functions, positions, tripping actions as per OEM guidelines & submitting test reports accordingly etc.complete as required. 1250 A, FP ACB:- 03 Nos.800 A FP ACB:- 04 Nos.(Any emergency breakdown visit shall be attended free of cost)Overhauling /servicing of following Schneider make 415V electrical ACBs from OEM/OEM Authorised Agency integrated in Main HVAC MCC Panel including checking all operational mechanisms, functions, positions, tripping actions as per OEM guidelines & submitting test reports accordingly etc.complete as required. 1250 A, FP ACB:- 03 Nos.800 A FP ACB:- 04 Nos.(Any emergency breakdown visit shall be attended free of cost)
10Repair of 10 to 15 HP Submersible/ Monoblock Pump including , lifting and lowering of pump from the sump ( approx 3 lac liter), transportation and copper rewinding , replacement of bearing, seal etc. complete as required.Repair of 10 to 15 HP Submersible/ Monoblock Pump including , lifting and lowering of pump from the sump ( approx 3 lac liter), transportation and copper rewinding , replacement of bearing, seal etc. complete as required.
11Repair of up to10 HP Submersible/Monoblock Pump including , lifting and lowering of pump from the sump ( approx 40000 liter), transportation and copper rewinding , replacement of bearing, seal etc. complete as required.Repair of up to10 HP Submersible/Monoblock Pump including , lifting and lowering of pump from the sump ( approx 40000 liter), transportation and copper rewinding , replacement of bearing, seal etc. complete as required.
12Repair of 2X2 ceiling mounted LED Panel Lights including supply of drivers, LEDs etc complete as required.Repair of 2X2 ceiling mounted LED Panel Lights including supply of drivers, LEDs etc complete as required.
13Repair of 36 W, 1X4 ceiling mounted LED Panel Lights including supply of drivers, LEDs etc complete as required.Repair of 36 W, 1X4 ceiling mounted LED Panel Lights including supply of drivers, LEDs etc complete as required.
14Repair of 25W/35W/40W Post Top LED Lamps including supply of drivers, LEDs etc complete as required.Repair of 25W/35W/40W Post Top LED Lamps including supply of drivers, LEDs etc complete as required.
15Repair of 70 W LED Street Lights including supply of drivers, LEDs etc complete as required.Repair of 70 W LED Street Lights including supply of drivers, LEDs etc complete as required.
16Location and finding of fault in underground LT Cable by pin pointing method etc complete as required.Location and finding of fault in underground LT Cable by pin pointing method etc complete as required.
17Providing and fixing of LED type fixtures (minimum 80 LED lights per day) for façade lighting with colour changing module on rental basis for illuminating the Integrated Operational Offices Building, RHQ, WR, Mumbai on front side of the building replicating national flag (Tri-colours and Ashok chakra) for 2 days including providing lighting accessories, manpower, transportation of material to & fro complete etc. as required for Independence Day & Republic Day, or as an when required.Providing and fixing of LED type fixtures (minimum 80 LED lights per day) for façade lighting with colour changing module on rental basis for illuminating the Integrated Operational Offices Building, RHQ, WR, Mumbai on front side of the building replicating national flag (Tri-colours and Ashok chakra) for 2 days including providing lighting accessories, manpower, transportation of material to & fro complete etc. as required for Independence Day & Republic Day, or as an when required.
18Provision of 1.5 TR Split Air Conditioners on hiring basis, including SITC, transportation, dismantling and taken back complete as required.Provision of 1.5 TR Split Air Conditioners on hiring basis, including SITC, transportation, dismantling and taken back complete as required.
19Provision of 2 TR Split Air Conditioners on hiring basis, including SITC, transportation, dismantling and taken back complete as required.Provision of 2 TR Split Air Conditioners on hiring basis, including SITC, transportation, dismantling and taken back complete as required.

AI Tender Summary

OUR REF NO 56726896
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 2.16 Crore
LAST DATE 19-08-2026
Authority
Authority Name Airports Authority Of India
Work Description Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - Annual Operation Maintenance Of Electrical Mechanical Installations In Integrated Operational Offices Building And 11 Kv Substation And Allied Works At Mumbai (2026-28); As Per Bid / Tender Document And.. - Operation And Maintenance Of Electrical & Mechanical Installations, Internal & External Ei Such As Light Fixtures, Fans, Light & Power Points, Lt Panels, Solar Street Lightning, Etc. By Carrying Out Operation, Repair, Maintenance, Attending To Complaints / Faults / Breakdowns And Taking Rectification Action, Ensuring Serviceability / Satisfactory Working Condition Of The Systems Installed In The Operational Offices Building I/C Preventive Maintenance, Maintenance Of Records / Documentation Etc. By Deploying Qualified Manpower In Two Shifts & General Shift (Each Shift Of Eight Hours) On All Working Days Including Sunday & Holidays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Operation And Maintenance Of Electrical & Mechanical Installations, Ht/Lt Panels, Synchronising Panel Of Dg Sets Etc. By Carrying Out Operation, Repair, Maintenance, Attending To Complaints / Faults / Breakdowns And Taking Rectification Action, Ensuring Serviceability / Satisfactory Working Condition Of The Systems Installed In The Substation I/C Preventive Maintenance, Maintenance Of Records / Documentation Etc. By Deploying Qualified Manpower In Three Shifts & General Shift (Each Shift Of Eight Hours) On All Working Days Including Sunday & Holidays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Operation Of 3 X 275Tr Water Cooled Screw Chillers Of Hvac System & Building Management System And Associated Equipments / Installations Viz, Chilled Water Pumps And Condensor Water Pumps, Cooling Towers, Ahus, Make-Up Water Tank, Expansion Tank, Hvac Panels Etc. Installed In The Operational Offices Building By Carrying Out Day To Day Operation And Maintaining Records / Documentation Etc. By Deploying Qualified Manpower In 2 Shifts (Each Shift Of Eight Hours) On All Working Days, Holidays & Excluding Sundays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Operation And Maintenance Of Water Pumping System Viz, Monoblock Pumps, Dewatering Pumps, Sewage Pumps, Dewatering Diesel Pump Etc. By Carrying Out Operation, Repair, Maintenance, Attending To Complaints / Faults / Breakdowns And Taking Rectification Action, Ensuring Serviceability / Satisfactory Working Condition Of The Systems Installed In The Operational Offices Building I/C Preventive Maintenance, Maintenance Of Records / Documentation Etc. By Deploying Qualified Manpower In In 2 Shifts (Each Shift Of Eight Hours) On All Working Days, Holidays & Excluding Sundays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Comprehensive Annual Maintenance Contract ( Camc) Of Façade Cleaning System Including Regular Maintenance Of Cradle, Motor, Winches, Gear Box, Rope Wires, Safety Device Etc. The Camc Includes Repairing Of Electric Control Box, Electric Switch Gear, Electric Motor , Gear Box, Winches, Checking Of Nuts Bolts, Wire Ropes, Replacement Of All Components Etc Complete As Required For Smooth And Trouble Free Operation Of Entire System . , Servicing And Testing Of Following 11 Kv Ht Panel Including Overhauling/Servicing Of Vcbs From Oem/Oem Authorised Agency, Of Following Ratings, Maintainance Of Complete Ht Panel Including Servicing & Testing Of Ct & Pt, Checking All Operational Mechanisms, Functions, Tripping Actions, Calibration Of Protective Relays & Testing With Secondary Current Injection Technique, Carrying Preventive Maintenance & Attending Breakdown Calls And And Submitting The Test Reports Accordingly Etc.Complete As Required. For Ioobincomer Panel:-630A, Tp Vcb :- 01 Nosoutgoing Panel:-630A, Tp Vcb :- 03 Nosmake & Model : Schneider & Hvx-X Type(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Servicing & Testing Of Following 11/0.433 Kv, Dry Type Cast Resin Transformers Of 1500 Kva, Volt Make By Carrying Out Preventive Maintenance Activity Of Transformer As Per Oem Recommendations To Keep The Transformer In Serviceable Condition. Work Includes Opening The Complete Encloser, Bus Bars, Ht & Lt Side Boxes, Cable Etc. Checking Of All The Safety Equipments, Cleaning, Servicing & Testing And Submission Of Service Reports Accordingly After Completion Of The Work As Per The Requirement.(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Servicing & Testing Of Following 11/0.433 Kv, Dry Type Cast Resin Transformers Of 1000 Kva, Kirloskar Make By Carrying Out Preventive Maintenance Activity Of Transformer As Per Oem Recommendations To Keep The Transformer In Serviceable Condition. Work Includes Opening The Complete Enclouser, Bus Bars, Ht & Lt Side Boxes, Cable Etc. Checking Of All The Safety Equipments, Cleaning, Servicing & Testing And Submission Of Service Reports Accordingly After Completion Of The Work As Per The Requirement.(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Overhauling /Servicing Of Following Schneider Make 415V Electrical Acbs From Oem/Oem Authorised Agency Integrated In Main Hvac Mcc Panel Including Checking All Operational Mechanisms, Functions, Positions, Tripping Actions As Per Oem Guidelines & Submitting Test Reports Accordingly Etc.Complete As Required. 1250 A, Fp Acb:- 03 Nos.800 A Fp Acb:- 04 Nos.(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Repair Of 10 To 15 Hp Submersible/ Monoblock Pump Including , Lifting And Lowering Of Pump From The Sump ( Approx 3 Lac Liter), Transportation And Copper Rewinding , Replacement Of Bearing, Seal Etc. Complete As Required. , Repair Of Up To10 Hp Submersible/Monoblock Pump Including , Lifting And Lowering Of Pump From The Sump ( Approx 40000 Liter), Transportation And Copper Rewinding , Replacement Of Bearing, Seal Etc. Complete As Required. , Repair Of 2X2 Ceiling Mounted Led Panel Lights Including Supply Of Drivers, Leds Etc Complete As Required. , Repair Of 36 W, 1X4 Ceiling Mounted Led Panel Lights Including Supply Of Drivers, Leds Etc Complete As Required. , Repair Of 25W/35W/40W Post Top Led L S Including Supply Of Drivers, Leds Etc Complete As Required. , Repair Of 70 W Led Street Lights Including Supply Of Drivers, Leds Etc Complete As Required. , Location And Finding Of Fault In Underground Lt Cable By Pin Pointing Method Etc Complete As Required. , Providing And Fixing Of Led Type Fixtures (Minimum 80 Led Lights Per Day) For Façade Lighting With Colour Changing Module On Rental Basis For Illuminating The Integrated Operational Offices Building, Rhq, Wr, Mumbai On Front Side Of The Building Replicating National Flag (Tri-Colours And Ashok Chakra) For 2 Days Including Providing Lighting Accessories, Manpower, Transportation Of Material To & Fro Complete Etc. As Required For Independence Day & Republic Day, Or As An When Required. , Provision Of 1.5 Tr Split Air Conditioners On Hiring Basis, Including Sitc, Transportation, Dismantling And Taken Back Complete As Required. , Provision Of 2 Tr Split Air Conditioners On Hiring Basis, Including Sitc, Transportation, Dismantling And Taken Back Complete As Required.
Basic Detail
Tender No GEM/2026/B/7850309
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 29 Jul 2026
Submission Date 19 Aug 2026
Open Date 19 Aug 2026
Finance
Tender Value 2.16 Crore
Tender Fee Ref. Documents
EMD 6.49 Lakhs
Exemption Not Available
Document List
4477635e-c819-4c21-81dc-d1af7b2a2fd8.pdf
1785320314.xlsx
1785320490.pdf
1785320491.pdf
1785320506.pdf
1785320521.pdf
1785320609.pdf
1785320612.pdf
tendoc29_3f04eac6-95ba-484a-b6b21785320989460_engg-e-wr-3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

4477635e-c819-4c21-81dc-d1af7b2a2fd8.pdf

xlsx

1785320314.xlsx

pdf

1785320490.pdf

pdf

1785320491.pdf

pdf

1785320506.pdf

pdf

1785320521.pdf

pdf

1785320609.pdf

pdf

1785320612.pdf

pdf

tendoc29_3f04eac6-95ba-484a-b6b21785320989460_engg-e-wr-3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders