Drinking Water Supply and Sanitation Government Departments Closing in 14 days TDR #56726383

Tender For Sambhal Water Supply Reorganization Scheme Under Amrut 2.0

Issued by Government Departments · Sambhal, Uttar Pradesh
Tender Value
123.65 Crore
Estimated cost
Bid Submission
13 Aug 2026
14 days left
EMD
1.23 Crore
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sambhal → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Sambhal Water Supply Reorganization Scheme Under Amrut 2.0

BOQ

Name of Work:- Sambhal Water Supply Reorganization Scheme Under AMRUT 2.0
Sl. No. Item Description
1Civil Works
2Rising Main
3Supply of following size of D.I. Pipe Class K-9 for rising main conforming to latest relevent to I.S.8329/2000 specification including railway frieght, insurance charges F.O.R. and supply of D.I. specials etc. complete as per instructions of Engineer-in-charge. All pipes should be supplied from the firm enlisted by Material Manager UP Jal Nigam Lucknow and should be proper inspection, testing, certification & marking by M/s Crown Agents India Pvt. Ltd. New Delhi, Elites India Pvt. Ltd., SGS India Pvt Ltd. New Delhi, & CIPET Lucknow.
4200mm dia D.I. Class-K9
5350mm dia D.I. Class-K9
6400mm dia D.I. Class-K9
7Supply of following sizes of D.I. D/F sluice valves as per I.S. 14846:2000 TESTED TO 10 Kg/sqm fixing in pipe line trenches, jointing and testing complete.
8200mm dia
9350mm dia
10400mm dia
11Carting of following sizes D.I.D./F Sluice Valve and specials and lowering them into the trenches, fixing in position and jointing them with pipelines and testing etc. complete including supply of jointing materials.
12200 mm dia
13350 mm dia
14400 mm dia
15Excavation for pipeline work in Ordinary Soil with lift up to 1.5 m and lead up to 50 m including filling back the excavated earth into the trenches with watering, ramming and disposal of surplus earth with in 50 m lead.
16Carting, Laying and Jointing of following size of DI pipes and specials and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete including testing of pipe lines and cutting of pipes.
17200 mm dia
18350 mm dia
19400 mm dia
20Supply of all materials and construct following chambers as per type design with supply of all labour, T&P etc. complete.
21Masonary Type Chamber
22Thrust Block
23RCC 1:1.5:3
24Mild Steel
25Dismantling following type of surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials required for proper completion of the work as per instruction of Engineer-in-charge.
26CC Road
27Interlocking Tiles Road
28Reinstatement following type of surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials required for proper completion of the work as per instruction of Engineer-in-charge.
29CC road will be prepared with 10cm thick P.C.C. 1:2:4 Cemant, Coarse Sand & Stone Grit over base concrete 15cm P:C:C 1:4:8 with Cement, Coarse Sand & 40mm Stone Ballast after compacting the earth surface properly. The C.C. Surface must be compacted with surface vibrator, including all materials, labour, T&P etc. complete.
30Interlocking Tile Road : Tiles must be of the thickness and grade similer to that of the dismantled tiles over base concrete 100mm thick P:C:C 1:4:8 cement, local sand & stone ballast as per existing road.The thickness of tiles shall be same as that of existing road, including all materials, labour, T&P etc. complete with 40% new tiles.
31Distribution System
32Supply of following size of pipe for distribution system conforming to latest relevent to I.S. 4984/2016 & 8329/2000 (HDPE Pipe and DI Pipe) specification including railway frieght, insurance charges F.O.R. and supply of HDPE & D.I. specials etc. complete as per instructions of Engineer-in-charge. All pipes should be supplied from the firm enlisted by Material Manager UP Jal Nigam Lucknow and should be proper inspection, testing, certification & marking by M/s Crown Agents India Pvt. Ltd. New Delhi, Elites India Pvt. Ltd., SGS India Pvt Ltd. New Delhi, & CIPET Lucknow.
33HDPE Pipe PN-6 PE - 100
34110 mm dia
35140 mm dia
36160mm dia
37DI K-7 Pipe
38200 mm DI K‐7
39250 mm DI K‐7
40300 mm DI K‐7
41350 mm DI K‐7
42400 mm DI K‐7
43450 mm DI K‐7
44500 mm DI K‐7
45Carting, Laying and Jointing by Electro Fusion Method of following size & type of pipes and specials from store to site of work and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete including testing of pipe lines and cutting of pipes and interconnection in existing pipeline wherever required.
46HDPE Pipe PN-6 PE - 100
47110 mm dia
48140 mm dia
49160 mm dia
50DI K-7 Pipe
51200 mm DI K‐7
52250 mm DI K‐7
53300 mm DI K‐7
54350 mm DI K‐7
55400 mm DI K‐7
56450 mm DI K‐7
57500 mm DI K‐7
58Excavation for pipeline work in Ordinary Soil with lift up to 1.5 M and lead up to 50 M including filling back the excavated earth into the trenches with watering, ramming and disposal of surplus earth with in 50 M lead.
59Supply of following Type/ sizes D.I.D./F valve including F.O.R. destination and taxes and insurance etc. complete as per relevant IS.
60Sluice Valve
61100 mm dia
62125 mm dia
63150 mm dia
64200 mm dia
65250 mm dia
66300 mm dia
67350 mm dia
68400 mm dia
69Scour Valve 100mm dia
70Fire Hydrant 80mm dia
71C.I. Single ball type air valve 20mm dia
72Carting of following sizes D.I. D./F Sluice Valve and specials from store to site of work and lowering them into the trenches, fixing in position and jointing them with pipelines and testing etc. complete including supply of jointing materials.
73Sluice Valve
74100 mm dia
75125 mm dia
76150 mm dia
77200 mm dia
78250 mm dia
79300 mm dia
80350 mm dia
81400 mm dia
82Scour Valve 100mm dia
83Fire Hydrant 80mm dia
84C.I. Single ball type air valve 20mm dia
85Supply of all materials and construct following chambers as per type design & drawing with supply of all labour, T&P etc. complete.
86Masonary Type Chamber
87Surface Box Type Chamber
88Fire Hydrant Chamber
89Air Valve Chamber
90VFD Pump Chamber
91Dismantling following type of surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials required for proper completion of the work as per instruction of Engineer-in-charge.
92BOE Road
93Bituminous Road (PR)
94CC Road
95Interlocking Road
96Reinstatement following type of surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials required for proper completion of the work as per instruction of Engineer-in-charge.
97B.O.E. Road with 40% new brick and 60% used old bricks over 30mm compacted local sand including all materials labour, T&P etc. complete.
98Bituminous roads with granular sub base (G1-100mm, G2-75mm, G3-75mm thick), 50mm thick bituminous macadum over priming coat and tack coat and 30mm thick SDBC/BC over tack coat and disposal of all debris and surplus earth with in 8km distance or as per direction of Engineer-in-Charge, including all materials, labour, T&P etc. complete
99CC road will be prepared with 10cm thick P.C.C. 1:2:4 Cemant, Coarse Sand & Stone Grit over base concrete 15cm P:C:C 1:4:8 with Cement, Coarse Sand & 40mm Stone Ballast after compacting the earth surface properly. The C.C. Surface must be compacted with surface vibrator, including all materials, labour, T&P etc. complete.
100Interlocking Tile Road : Tiles must be of the thickness and grade similer to that of the dismantled tiles over base concrete 100mm thick P:C:C 1:4:8 cement, local sand & stone ballast as per existing road.The thickness of tiles shall be same as that of existing road, including all materials, labour, T&P etc. complete with 40% new tiles.
101Provision of crossing of Nalas & culvert complete i.e. total material MS 6mm thick covering pipe with appoxy paint both side, dismentling and repair of nala walls floor etc. (including supply of all materials including FOR destinaion inclusive of all taxes and duties third party inspection charge, transit insurance, freight, loading, unloading and stacking in store etc. complete) & labour cost as per type design & as per unit estimate type desing and drawing and as per instruction of Engineer-in- charge.
102Nala Crossing (more than 0.5 m to 1.50 m)
103Nala Crossing (more than 1.5 m to 3.50 m)
104Culvert Crossing (for more than 3.5 m wide and above)
105Making ferrule connection of various nominal dia of distribution mains in different type of roads including dismantling and reinstatement for trenches with fixing of saddle piece. service connections. fittings. and fixing of brass ferrule of 15mm size including tapping the main, include the cost of excavation and subsequent backfill fo trenches and cost of fitting and specials, including labour charges for cutting, threading & fitting of GI pipe and specials including supply of binding materials such as safeda and teflon tape etc. Including making hole in the wall for crossing of GI pipe also repairing the same with mortar and also including crossing of drain with all labour T&P etc complete including material i.e. 3 meter 20mm dia (OD) HDPE pipe (12.5 kg/cm2), 2 meter 20mm (OD) GI pipe, Class-B, EL-bow 20mm (OD) GI for above pipe Class-B, Clamp with saddle, TAP/Stop Cock (Brass) 15mm, Ferrule brass HDPE 15mm with end cap (heavy duty), 20mm dia PP-Adopter and 20mm dia GI-Union.
106In BOE Road
107Upto 110mm dia
108For 125mm to 160mm dia
109In Bituminus Road (PR)
110Upto 110mm dia
111For 125mm to 160mm dia
112For 180mm to 250mm dia
113For 300mm dia
114For 350mm to 500mm dia
115In CC Road
116Upto 110mm dia
117For 125mm to 160mm dia
118For 180mm to 250mm dia
119For 300mm dia
120For 350mm to 500mm dia
121In Interlocking Tiles Road (IL)
122Upto 110mm dia
123For 125mm to 160mm dia
124For 180mm to 250mm dia
125For 300mm dia
126For 350mm to 500mm dia
127In Kaccha (KC)
128Upto 110mm dia
129For 125mm to 160mm dia
130For 180mm to 250mm dia
131For 300mm dia
132For 350mm to 500mm dia
133Shifting of existing house connection to following sizes of new distribution pipes including supply, carting of specials, lowering them into trenches cutting, fixing them in proper alignment and jointing with old serviceable material including bailing out of water, necessary, excavation for connection and barricading including all labour, T&P etc. required for proper completion of the work in all types of roads.
134In CC Road
135Upto 110mm dia
136In Interlocking Tiles Road (IL)
137Upto 110mm dia
138Variation in 20mm (OD) dia HDPE pipe w.r.t. 3.0 mtr.
139Variation in 20mm (OD) dia GI pipe w.r.t. 2.0 mtr.
140Provision of crossing of state highway/ Major Road by trenchless technology for distribution main including cost of machinery, repairing of roads etc as per unit estimate enclosed including supply of MS pipe and all materials including all taxes and duties third party inspection charge, transit insurance, freight, loading, unloading and stacking in departmental store etc. complete
141300 mm dia 6 mm thick with MS Casing
142350 mm dia 6 mm thick with MS Casing
143Overhead Tank Zone - 9 (2500 KL/25m Stagging) : Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911. Made up level will be as per site conditions and as per directions of Engineer-in-charge and minimum will be 0.70m.
144All Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456.
145Minimum depth of foundation below original ground level will be 3.0 M.
146Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure.
147If SBC is found more than 8.0 tonne/sqm then minimum SBC will be considered as 8.0 tonne/sqm.
1481m wide RCC stair case from ground lavel to balcony.
149M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body ( from manhole in top dome to bootom dome).
1501 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.
151Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.
152Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.
153Electro Megnetic Flow Meter
154Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.
155D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.
156Supply, fixing, jointing of following size of D.I. D/F Pipes with D.I. D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, over flow and washout as per latest / relevent I.S. specifications with all jointing materials for proper completion of work including other appurtenant works and excavation in all types of soil as per site conditions and as per directions of Engineer-in-charge.
157Supply and Fixing of following sizes D.I. D/F sluice valves with hand wheels as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete as per site conditions and as per directions of Engineer-in-charge.
158Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil.
159Construction of surface box type Sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement.
160Construction of washout/ overflow chamber as per departmental type design and drawing.
161Construction of R. C. C. Floor & Drain and all other necessary work as per departmental type drawing and design.
162Painting of all concrete surface and steel pipe worrks with three coats of approved cement paint and anticorrosive paints.
163Testing & Commission etc. all complete work.
164Testing of bearing capacity of soil from a recognized Govt. Engineering College or as directed by department.
165Overhead Tank Zone - 10 (2700 KL/25m Stagging) : Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911. Made up level will be as per site conditions and as per directions of Engineer-in-charge and minimum will be 0.70m.
166All Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456.
167Minimum depth of foundation below original ground level will be 3.0 M.
168Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure.
169If SBC is found more than 8.0 tonne/sqm then minimum SBC will be considered as 8.0 tonne/sqm.
1701m wide RCC stair case from ground lavel to balcony.
171M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body ( from manhole in top dome to bootom dome).
1721 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.
173Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.
174Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.
175Electro Megnetic Flow Meter
176Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.
177D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.
178Supply, fixing, jointing of following size of D.I. D/F Pipes with D.I. D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, over flow and washout as per latest / relevent I.S. specifications with all jointing materials for proper completion of work including other appurtenant works and excavation in all types of soil as per site conditions and as per directions of Engineer-in-charge.
179Supply and Fixing of following sizes D.I. D/F sluice valves with hand wheels as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete as per site conditions and as per directions of Engineer-in-charge.
180Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil.
181Construction of surface box type Sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement.
182Construction of washout/ overflow chamber as per departmental type design and drawing.
183Construction of R. C. C. Floor & Drain and all other necessary work as per departmental type drawing and design.
184Painting of all concrete surface and steel pipe worrks with three coats of approved cement paint and anticorrosive paints.
185Testing & Commission etc. all complete work.
186Testing of bearing capacity of soil from a recognized Govt. Engineering College or as directed by department.
187Overhead Tank Zone - 11 (2100 KL/25m Stagging) : Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911. Made up level will be as per site conditions and as per directions of Engineer-in-charge and minimum will be 0.70m.
188All Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456.
189Minimum depth of foundation below original ground level will be 3.0 M.
190Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure.
191If SBC is found more than 8.0 tonne/sqm then minimum SBC will be considered as 8.0 tonne/sqm.
1921m wide RCC stair case from ground lavel to balcony.
193M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body ( from manhole in top dome to bootom dome).
1941 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.
195Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.
196Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.
197Electro Megnetic Flow Meter
198Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.
199D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.
200Supply, fixing, jointing of following size of D.I. D/F Pipes with D.I. D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, over flow and washout as per latest / relevent I.S. specifications with all jointing materials for proper completion of work including other appurtenant works and excavation in all types of soil as per site conditions and as per directions of Engineer-in-charge.
201Supply and Fixing of following sizes D.I. D/F sluice valves with hand wheels as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete as per site conditions and as per directions of Engineer-in-charge.
202Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil.
203Construction of surface box type Sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement.
204Construction of washout/ overflow chamber as per departmental type design and drawing.
205Construction of R. C. C. Floor & Drain and all other necessary work as per departmental type drawing and design.
206Painting of all concrete surface and steel pipe worrks with three coats of approved cement paint and anticorrosive paints.
207Testing & Commission etc. all complete work.
208Testing of bearing capacity of soil from a recognized Govt. Engineering College or as directed by department.
209Overhead Tank Zone - 12 (2000 KL/25m Stagging): Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911. Made up level will be as per site conditions and as per directions of Engineer-in-charge and minimum will be 0.70m.
210All Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456.
211Minimum depth of foundation below original ground level will be 3.0 M.
212Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure.
213If SBC is found more than 8.0 tonne/sqm then minimum SBC will be considered as 8.0 tonne/sqm.
2141m wide RCC stair case from ground lavel to balcony.
215M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body ( from manhole in top dome to bootom dome).
2161 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.
217Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.
218Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.
219Electro Megnetic Flow Meter
220Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.
221D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.
222Supply, fixing, jointing of following size of D.I. D/F Pipes with D.I. D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, over flow and washout as per latest / relevent I.S. specifications with all jointing materials for proper completion of work including other appurtenant works and excavation in all types of soil as per site conditions and as per directions of Engineer-in-charge.
223Supply and Fixing of following sizes D.I. D/F sluice valves with hand wheels as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete as per site conditions and as per directions of Engineer-in-charge.
224Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil.
225Construction of surface box type Sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement.
226Construction of washout/ overflow chamber as per departmental type design and drawing.
227Construction of R. C. C. Floor & Drain and all other necessary work as per departmental type drawing and design.
228Painting of all concrete surface and steel pipe worrks with three coats of approved cement paint and anticorrosive paints.
229Testing & Commission etc. all complete work.
230Testing of bearing capacity of soil from a recognized Govt. Engineering College or as directed by department.
231Overhead Tank Zone - 13 (1700 KL/25m Stagging) : Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911. Made up level will be as per site conditions and as per directions of Engineer-in-charge and minimum will be 0.70m.
232All Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456.
233Minimum depth of foundation below original ground level will be 3.0 M.
234Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure.
235If SBC is found more than 8.0 tonne/sqm then minimum SBC will be considered as 8.0 tonne/sqm.
2361m wide RCC stair case from ground lavel to balcony.
237M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body ( from manhole in top dome to bootom dome).
2381 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.
239Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.
240Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.
241Electro Megnetic Flow Meter
242Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.
243D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.
244Supply, fixing, jointing of following size of D.I. D/F Pipes with D.I. D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, over flow and washout as per latest / relevent I.S. specifications with all jointing materials for proper completion of work including other appurtenant works and excavation in all types of soil as per site conditions and as per directions of Engineer-in-charge.
245Supply and Fixing of following sizes D.I. D/F sluice valves with hand wheels as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete as per site conditions and as per directions of Engineer-in-charge.
246Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil.
247Construction of surface box type Sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement.
248Construction of washout/ overflow chamber as per departmental type design and drawing.
249Construction of R. C. C. Floor & Drain and all other necessary work as per departmental type drawing and design.
250Painting of all concrete surface and steel pipe worrks with three coats of approved cement paint and anticorrosive paints.
251Testing & Commission etc. all complete work.
252Testing of bearing capacity of soil from a recognized Govt. Engineering College or as directed by department.
253Overhead Tank Zone - 14 (2300 KL/25m Stagging) : Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911. Made up level will be as per site conditions and as per directions of Engineer-in-charge and minimum will be 0.70m.
254All Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456.
255Minimum depth of foundation below original ground level will be 3.0 M.
256Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure.
257If SBC is found more than 8.0 tonne/sqm then minimum SBC will be considered as 8.0 tonne/sqm.
2581m wide RCC stair case from ground lavel to balcony.
259M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body ( from manhole in top dome to bootom dome).
2601 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.
261Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.
262Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.
263Electro Megnetic Flow Meter
264Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.
265D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.
266Supply, fixing, jointing of following size of D.I. D/F Pipes with D.I. D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, over flow and washout as per latest / relevent I.S. specifications with all jointing materials for proper completion of work including other appurtenant works and excavation in all types of soil as per site conditions and as per directions of Engineer-in-charge.
267Supply and Fixing of following sizes D.I. D/F sluice valves with hand wheels as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete as per site conditions and as per directions of Engineer-in-charge.
268Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil.
269Construction of surface box type Sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement.
270Construction of washout/ overflow chamber as per departmental type design and drawing.
271Construction of R. C. C. Floor & Drain and all other necessary work as per departmental type drawing and design.
272Painting of all concrete surface and steel pipe worrks with three coats of approved cement paint and anticorrosive paints.
273Testing & Commission etc. all complete work.
274Testing of bearing capacity of soil from a recognized Govt. Engineering College or as directed by department.
275Repairing of existing OHT 2500KL/22m Stagging in Zone-1
276Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners also included structural testing of the existing OHT from reputed govt. engineering institution etc. as directed by Engineer- in-Charge.
27725mm thick in Grade M 25 with cement content not less than 330 kg per cum.
27850mm thick in Grade M 25 with cement content not less than 330 kg per cum.
279Dismantling cement concrete floor of OHT including base concrete.
28025 mm thick 1:2:4 plain cement concrete floor with cement,coarse sand and 20 mm gauge approved stone ballast laid in panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cemnet,4 part of local sand and 8 part 1st class brick ballast 4 cm gauge (1:4:8) and removing any over lapping of mortar at the joist of panel if an and giving them uniform finished including supply material, labour,T&P etc required for proper compltion of work.
281R.C.C. work with cement, coarse sand and 20mm stone ballast 1:1.5:3 in floor of OHT excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50mm thick binding wire and including necessary centering and shuttering supply of all material, labour, T&P etc required for proper completion the work.
282M.S. or iron work in plain work in floor of OHT to provide minimum reinforcement brought to required shape as necessary including binding for proper completion of the work including supply of steel and its wastage.
283Supply and fixing 75x75x6mm M.S. angle iron ladder with 20mm dia round bar about 250mm c/c out side and inside of tank, including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
284Supply and fixing 50x50x6mm M.S. angle iron railing post including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
285Supply and fixing 20mm dia G.I. pipe with specials in railing including supply of all material, labour & T&P etc. complete for proper completion of the work.
286Supply and fixing of M.S. main hole cover at top dome including grounting painting, supply of all materials, labour, T&P etc. complete.
287Providing & fixing fly proof Galvanised M.S. wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
288Supply and fixing of lighting conductor of approved quality of copper/ GI strips (32 mm x 6 mm) from top to bottom of the tank as per ISI standard including supply of all materials, labour, T&P etc. complete.
289Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. earthing materials such as pipe, wire/earthing plate including supply of all materials, labour, T&P etc. complete.
290Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
291Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work in Two coats over existing old RCC surface including supply of all material, labour, T&P etc. complete.
292Providing necessary scafolding/shuttering for repairing, removing of old color paint and color painting work on O.H.T. surface form bottom to top dome & Stair case including supply of all material, labour etc. complete.
293Cleaning of Over Head R.C.C. Tank including disposal of silt and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i) Tank shall be emptied of water & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the OHT shall then scrubbed thoroughly with wire brush etc, and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine. (iv)The treated surface shall be dried using air jetting and all loose paricles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc, as per direction of Engineer-in-charge.
294Construction of U type Drain 200mm x150mm including supply of all material, Labour and T&P etc. complete for proper completion of the work.
295Repairing of existing OHT 2200KL/20m Stagging in Zone-2
296Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners also included structural testing of the existing OHT from reputed govt. engineering institution etc. as directed by Engineer- in-Charge.
29725mm thick in Grade M 25 with cement content not less than 330 kg per cum.
29850mm thick in Grade M 25 with cement content not less than 330 kg per cum.
299Dismantling cement concrete floor of OHT including base concrete.
30025 mm thick 1:2:4 plain cement concrete floor with cement,coarse sand and 20 mm gauge approved stone ballast laid in panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cemnet,4 part of local sand and 8 part 1st class brick ballast 4 cm gauge (1:4:8) and removing any over lapping of mortar at the joist of panel if an and giving them uniform finished including supply material, labour,T&P etc required for proper compltion of work.
301R.C.C. work with cement, coarse sand and 20mm stone ballast 1:1.5:3 in floor of OHT excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50mm thick binding wire and including necessary centering and shuttering supply of all material, labour, T&P etc required for proper completion the work.
302M.S. or iron work in plain work in floor of OHT to provide minimum reinforcement brought to required shape as necessary including binding for proper completion of the work including supply of steel and its wastage.
303Supply and fixing 75x75x6mm M.S. angle iron ladder with 20mm dia round bar about 250mm c/c out side and inside of tank, including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
304Supply and fixing 50x50x6mm M.S. angle iron railing post including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
305Supply and fixing 20mm dia G.I. pipe with specials in railing including supply of all material, labour & T&P etc. complete for proper completion of the work.
306Supply and fixing of M.S. main hole cover at top dome including grounting painting, supply of all materials, labour, T&P etc. complete.
307Providing & fixing fly proof Galvanised M.S. wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
308Supply and fixing of lighting conductor of approved quality of copper/ GI strips (32 mm x 6 mm) from top to bottom of the tank as per ISI standard including supply of all materials, labour, T&P etc. complete.
309Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. earthing materials such as pipe, wire/earthing plate including supply of all materials, labour, T&P etc. complete.
310Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
311Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work in Two coats over existing old RCC surface including supply of all material, labour, T&P etc. complete.
312Providing necessary scafolding/shuttering for repairing, removing of old color paint and color painting work on O.H.T. surface form bottom to top dome & Stair case including supply of all material, labour etc. complete.
313Cleaning of Over Head R.C.C. Tank including disposal of silt and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i) Tank shall be emptied of water & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the OHT shall then scrubbed thoroughly with wire brush etc, and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine. (iv)The treated surface shall be dried using air jetting and all loose paricles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc, as per direction of Engineer-in-charge.
314Construction of U type Drain 200mm x150mm including supply of all material, Labour and T&P etc. complete for proper completion of the work.
315Repairing of existing OHT 1500KL/17m Stagging in Zone-3
316Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners also included structural testing of the existing OHT from reputed govt. engineering institution etc. as directed by Engineer- in-Charge.
31725mm thick in Grade M 25 with cement content not less than 330 kg per cum.
31850mm thick in Grade M 25 with cement content not less than 330 kg per cum.
319Dismantling cement concrete floor of OHT including base concrete.
32025 mm thick 1:2:4 plain cement concrete floor with cement,coarse sand and 20 mm gauge approved stone ballast laid in panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cemnet,4 part of local sand and 8 part 1st class brick ballast 4 cm gauge (1:4:8) and removing any over lapping of mortar at the joist of panel if an and giving them uniform finished including supply material, labour,T&P etc required for proper compltion of work.
321R.C.C. work with cement, coarse sand and 20mm stone ballast 1:1.5:3 in floor of OHT excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50mm thick binding wire and including necessary centering and shuttering supply of all material, labour, T&P etc required for proper completion the work.
322M.S. or iron work in plain work in floor of OHT to provide minimum reinforcement brought to required shape as necessary including binding for proper completion of the work including supply of steel and its wastage.
323Supply and fixing 75x75x6mm M.S. angle iron ladder with 20mm dia round bar about 250mm c/c out side and inside of tank, including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
324Supply and fixing 50x50x6mm M.S. angle iron railing post including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
325Supply and fixing 20mm dia G.I. pipe with specials in railing including supply of all material, labour & T&P etc. complete for proper completion of the work.
326Supply and fixing of M.S. main hole cover at top dome including grounting painting, supply of all materials, labour, T&P etc. complete.
327Providing & fixing fly proof Galvanised M.S. wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
328Supply and fixing of lighting conductor of approved quality of copper/ GI strips (32 mm x 6 mm) from top to bottom of the tank as per ISI standard including supply of all materials, labour, T&P etc. complete.
329Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. earthing materials such as pipe, wire/earthing plate including supply of all materials, labour, T&P etc. complete.
330Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
331Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work in Two coats over existing old RCC surface including supply of all material, labour, T&P etc. complete.
332Providing necessary scafolding/shuttering for repairing, removing of old color paint and color painting work on O.H.T. surface form bottom to top dome & Stair case including supply of all material, labour etc. complete.
333Cleaning of Over Head R.C.C. Tank including disposal of silt and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i) Tank shall be emptied of water & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the OHT shall then scrubbed thoroughly with wire brush etc, and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine. (iv)The treated surface shall be dried using air jetting and all loose paricles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc, as per direction of Engineer-in-charge.
334Construction of U type Drain 200mm x150mm including supply of all material, Labour and T&P etc. complete for proper completion of the work.
335Repairing of existing OHT 800KL/16m Stagging in Zone-4
336Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners also included structural testing of the existing OHT from reputed govt. engineering institution etc. as directed by Engineer- in-Charge.
33725mm thick in Grade M 25 with cement content not less than 330 kg per cum.
33850mm thick in Grade M 25 with cement content not less than 330 kg per cum.
339Dismantling cement concrete floor of OHT including base concrete.
34025 mm thick 1:2:4 plain cement concrete floor with cement,coarse sand and 20 mm gauge approved stone ballast laid in panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cemnet,4 part of local sand and 8 part 1st class brick ballast 4 cm gauge (1:4:8) and removing any over lapping of mortar at the joist of panel if an and giving them uniform finished including supply material, labour,T&P etc required for proper compltion of work.
341R.C.C. work with cement, coarse sand and 20mm stone ballast 1:1.5:3 in floor of OHT excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50mm thick binding wire and including necessary centering and shuttering supply of all material, labour, T&P etc required for proper completion the work.
342M.S. or iron work in plain work in floor of OHT to provide minimum reinforcement brought to required shape as necessary including binding for proper completion of the work including supply of steel and its wastage.
343Supply and fixing 75x75x6mm M.S. angle iron ladder with 20mm dia round bar about 250mm c/c out side and inside of tank, including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
344Supply and fixing 50x50x6mm M.S. angle iron railing post including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
345Supply and fixing 20mm dia G.I. pipe with specials in railing including supply of all material, labour & T&P etc. complete for proper completion of the work.
346Supply and fixing of M.S. main hole cover at top dome including grounting painting, supply of all materials, labour, T&P etc. complete.
347Providing & fixing fly proof Galvanised M.S. wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
348Supply and fixing of lighting conductor of approved quality of copper/ GI strips (32 mm x 6 mm) from top to bottom of the tank as per ISI standard including supply of all materials, labour, T&P etc. complete.
349Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. earthing materials such as pipe, wire/earthing plate including supply of all materials, labour, T&P etc. complete.
350Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
351Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work in Two coats over existing old RCC surface including supply of all material, labour, T&P etc. complete.
352Providing necessary scafolding/shuttering for repairing, removing of old color paint and color painting work on O.H.T. surface form bottom to top dome & Stair case including supply of all material, labour etc. complete.
353Cleaning of Over Head R.C.C. Tank including disposal of silt and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i) Tank shall be emptied of water & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the OHT shall then scrubbed thoroughly with wire brush etc, and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine. (iv)The treated surface shall be dried using air jetting and all loose paricles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc, as per direction of Engineer-in-charge.
354Construction of U type Drain 200mm x150mm including supply of all material, Labour and T&P etc. complete for proper completion of the work.
355Repairing of existing OHT 1700KL/20m Stagging in Zone-5
356Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners also included structural testing of the existing OHT from reputed govt. engineering institution etc. as directed by Engineer- in-Charge.
35725mm thick in Grade M 25 with cement content not less than 330 kg per cum.
35850mm thick in Grade M 25 with cement content not less than 330 kg per cum.
359Dismantling cement concrete floor of OHT including base concrete.
36025 mm thick 1:2:4 plain cement concrete floor with cement,coarse sand and 20 mm gauge approved stone ballast laid in panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cemnet,4 part of local sand and 8 part 1st class brick ballast 4 cm gauge (1:4:8) and removing any over lapping of mortar at the joist of panel if an and giving them uniform finished including supply material, labour,T&P etc required for proper compltion of work.
361R.C.C. work with cement, coarse sand and 20mm stone ballast 1:1.5:3 in floor of OHT excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50mm thick binding wire and including necessary centering and shuttering supply of all material, labour, T&P etc required for proper completion the work.
362M.S. or iron work in plain work in floor of OHT to provide minimum reinforcement brought to required shape as necessary including binding for proper completion of the work including supply of steel and its wastage.
363Supply and fixing 75x75x6mm M.S. angle iron ladder with 20mm dia round bar about 250mm c/c out side and inside of tank, including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
364Supply and fixing 50x50x6mm M.S. angle iron railing post including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
365Supply and fixing 20mm dia G.I. pipe with specials in railing including supply of all material, labour & T&P etc. complete for proper completion of the work.
366Supply and fixing of M.S. main hole cover at top dome including grounting painting, supply of all materials, labour, T&P etc. complete.
367Providing & fixing fly proof Galvanised M.S. wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
368Supply and fixing of lighting conductor of approved quality of copper/ GI strips (32 mm x 6 mm) from top to bottom of the tank as per ISI standard including supply of all materials, labour, T&P etc. complete.
369Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. earthing materials such as pipe, wire/earthing plate including supply of all materials, labour, T&P etc. complete.
370Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
371Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work in Two coats over existing old RCC surface including supply of all material, labour, T&P etc. complete.
372Providing necessary scafolding/shuttering for repairing, removing of old color paint and color painting work on O.H.T. surface form bottom to top dome & Stair case including supply of all material, labour etc. complete.
373Cleaning of Over Head R.C.C. Tank including disposal of silt and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i) Tank shall be emptied of water & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the OHT shall then scrubbed thoroughly with wire brush etc, and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine. (iv)The treated surface shall be dried using air jetting and all loose paricles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc, as per direction of Engineer-in-charge.
374Construction of U type Drain 200mm x150mm including supply of all material, Labour and T&P etc. complete for proper completion of the work.
375Repairing of existing OHT 2500KL/20m Stagging in Zone-6
376Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners also included structural testing of the existing OHT from reputed govt. engineering institution etc. as directed by Engineer- in-Charge.
37725mm thick in Grade M 25 with cement content not less than 330 kg per cum.
37850mm thick in Grade M 25 with cement content not less than 330 kg per cum.
379Dismantling cement concrete floor of OHT including base concrete.
38025 mm thick 1:2:4 plain cement concrete floor with cement,coarse sand and 20 mm gauge approved stone ballast laid in panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cemnet,4 part of local sand and 8 part 1st class brick ballast 4 cm gauge (1:4:8) and removing any over lapping of mortar at the joist of panel if an and giving them uniform finished including supply material, labour,T&P etc required for proper compltion of work.
381R.C.C. work with cement, coarse sand and 20mm stone ballast 1:1.5:3 in floor of OHT excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50mm thick binding wire and including necessary centering and shuttering supply of all material, labour, T&P etc required for proper completion the work.
382M.S. or iron work in plain work in floor of OHT to provide minimum reinforcement brought to required shape as necessary including binding for proper completion of the work including supply of steel and its wastage.
383Supply and fixing 75x75x6mm M.S. angle iron ladder with 20mm dia round bar about 250mm c/c out side and inside of tank, including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
384Supply and fixing 50x50x6mm M.S. angle iron railing post including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
385Supply and fixing 20mm dia G.I. pipe with specials in railing including supply of all material, labour & T&P etc. complete for proper completion of the work.
386Supply and fixing of M.S. main hole cover at top dome including grounting painting, supply of all materials, labour, T&P etc. complete.
387Providing & fixing fly proof Galvanised M.S. wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
388Supply and fixing of lighting conductor of approved quality of copper/ GI strips (32 mm x 6 mm) from top to bottom of the tank as per ISI standard including supply of all materials, labour, T&P etc. complete.
389Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. earthing materials such as pipe, wire/earthing plate including supply of all materials, labour, T&P etc. complete.
390Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
391Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work in Two coats over existing old RCC surface including supply of all material, labour, T&P etc. complete.
392Providing necessary scafolding/shuttering for repairing, removing of old color paint and color painting work on O.H.T. surface form bottom to top dome & Stair case including supply of all material, labour etc. complete.
393Cleaning of Over Head R.C.C. Tank including disposal of silt and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i) Tank shall be emptied of water & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the OHT shall then scrubbed thoroughly with wire brush etc, and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine. (iv)The treated surface shall be dried using air jetting and all loose paricles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc, as per direction of Engineer-in-charge.
394Construction of U type Drain 200mm x150mm including supply of all material, Labour and T&P etc. complete for proper completion of the work.
395Repairing of existing OHT 2000KL/20m Stagging in Zone-7
396Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners also included structural testing of the existing OHT from reputed govt. engineering institution etc. as directed by Engineer- in-Charge.
39725mm thick in Grade M 25 with cement content not less than 330 kg per cum.
39850mm thick in Grade M 25 with cement content not less than 330 kg per cum.
399Dismantling cement concrete floor of OHT including base concrete.
40025 mm thick 1:2:4 plain cement concrete floor with cement,coarse sand and 20 mm gauge approved stone ballast laid in panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cemnet,4 part of local sand and 8 part 1st class brick ballast 4 cm gauge (1:4:8) and removing any over lapping of mortar at the joist of panel if an and giving them uniform finished including supply material, labour,T&P etc required for proper compltion of work.
401R.C.C. work with cement, coarse sand and 20mm stone ballast 1:1.5:3 in floor of OHT excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50mm thick binding wire and including necessary centering and shuttering supply of all material, labour, T&P etc required for proper completion the work.
402M.S. or iron work in plain work in floor of OHT to provide minimum reinforcement brought to required shape as necessary including binding for proper completion of the work including supply of steel and its wastage.
403Supply and fixing 75x75x6mm M.S. angle iron ladder with 20mm dia round bar about 250mm c/c out side and inside of tank, including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
404Supply and fixing 50x50x6mm M.S. angle iron railing post including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge.
405Supply and fixing 20mm dia G.I. pipe with specials in railing including supply of all material, labour & T&P etc. complete for proper completion of the work.
406Supply and fixing of M.S. main hole cover at top dome including grounting painting, supply of all materials, labour, T&P etc. complete.
407Providing & fixing fly proof Galvanised M.S. wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
408Supply and fixing of lighting conductor of approved quality of copper/ GI strips (32 mm x 6 mm) from top to bottom of the tank as per ISI standard including supply of all materials, labour, T&P etc. complete.
409Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. earthing materials such as pipe, wire/earthing plate including supply of all materials, labour, T&P etc. complete.
410Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
411Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work in Two coats over existing old RCC surface including supply of all material, labour, T&P etc. complete.
412Providing necessary scafolding/shuttering for repairing, removing of old color paint and color painting work on O.H.T. surface form bottom to top dome & Stair case including supply of all material, labour etc. complete.
413Cleaning of Over Head R.C.C. Tank including disposal of silt and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i) Tank shall be emptied of water & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the OHT shall then scrubbed thoroughly with wire brush etc, and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine. (iv)The treated surface shall be dried using air jetting and all loose paricles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc, as per direction of Engineer-in-charge.
414Construction of U type Drain 200mm x150mm including supply of all material, Labour and T&P etc. complete for proper completion of the work.
415CWR Zone-1 650 KL
416Supply of all materials, labour, T&P etc. and construct an RCC CWR of following capacity with RCC structures G.I. Pipe and angle iron posts around the top of sump, M.S. ladder inside the tank, supply and fixing M.H. cover with locking device, ventilator, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC coloumn, 25 mm thick PCC 1:2:4 floor over 80 mm PCC 1:4:8 in appron, 150 mm semicircular drain around the sump, escape channel of 20m length and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary CI D/Fpipes and valves etc. all complete including testing of bearing capacity of soil and site clearance and other unforeseen items for following zones/sub zones including cost of electric sub Station, HT Panel Room 4mx4m and Meter Room 3mx3m as per requirement of E.E. CD (E/M) UPJN (U) Ghaziabad.
417CWR Zone-6 650 KL
418Supply of all materials, labour, T&P etc. and construct an RCC CWR of following capacity with RCC structures G.I. Pipe and angle iron posts around the top of sump, M.S. ladder inside the tank, supply and fixing M.H. cover with locking device, ventilator, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC coloumn, 25 mm thick PCC 1:2:4 floor over 80 mm PCC 1:4:8 in appron, 150 mm semicircular drain around the sump, escape channel of 20m length and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary CI D/Fpipes and valves etc. all complete including testing of bearing capacity of soil and site clearance and other unforeseen items for following zones/sub zones including cost of electric sub Station, HT Panel Room 4mx4m and Meter Room 3mx3m as per requirement of E.E. CD (E/M) UPJN (U) Ghaziabad.
419CWR Zone-9 650 KL
420Supply of all materials, labour, T&P etc. and construct an RCC CWR of following capacity with RCC structures G.I. Pipe and angle iron posts around the top of sump, M.S. ladder inside the tank, supply and fixing M.H. cover with locking device, ventilator, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC coloumn, 25 mm thick PCC 1:2:4 floor over 80 mm PCC 1:4:8 in appron, 150 mm semicircular drain around the sump, escape channel of 20m length and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary CI D/Fpipes and valves etc. all complete including testing of bearing capacity of soil and site clearance and other unforeseen items for following zones/sub zones including cost of electric sub Station, HT Panel Room 4mx4m and Meter Room 3mx3m as per requirement of E.E. CD (E/M) UPJN (U) Ghaziabad.
421CWR Zone-10 700 KL
422Supply of all materials, labour, T&P etc. and construct an RCC CWR of following capacity with RCC structures G.I. Pipe and angle iron posts around the top of sump, M.S. ladder inside the tank, supply and fixing M.H. cover with locking device, ventilator, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC coloumn, 25 mm thick PCC 1:2:4 floor over 80 mm PCC 1:4:8 in appron, 150 mm semicircular drain around the sump, escape channel of 20m length and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary CI D/Fpipes and valves etc. all complete including testing of bearing capacity of soil and site clearance and other unforeseen items for following zones/sub zones including cost of electric sub Station, HT Panel Room 4mx4m and Meter Room 3mx3m as per requirement of E.E. CD (E/M) UPJN (U) Ghaziabad.
423CWR Zone-14 600 KL
424Supply of all materials, labour, T&P etc. and construct an RCC CWR of following capacity with RCC structures G.I. Pipe and angle iron posts around the top of sump, M.S. ladder inside the tank, supply and fixing M.H. cover with locking device, ventilator, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC coloumn, 25 mm thick PCC 1:2:4 floor over 80 mm PCC 1:4:8 in appron, 150 mm semicircular drain around the sump, escape channel of 20m length and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary CI D/Fpipes and valves etc. all complete including testing of bearing capacity of soil and site clearance and other unforeseen items for following zones/sub zones including cost of electric sub Station, HT Panel Room 4mx4m and Meter Room 3mx3m as per requirement of E.E. CD (E/M) UPJN (U) Ghaziabad.
425Pumphouse
426Supply of all materials and construction of pump house cum chlorinating room (3.60mx3.00mx3.60m and 1.8mx1.25mx3.00m) as per direction of Engineer-in-charge
427Zone-1
428Zone-5
429Zone-6
430Zone-7
431Zone-9
432Zone-10
433Zone-11
434Zone-12
435Zone-13
436Zone-14
437Construction of 1.0x1.0x1.3 m masonry type byepass chamber including plaster, supply of all material, labour, T & P etc. required for proper completion of work
438Extra Ist class brick work in 1:6 cement and coarse sand mortar in foundation and plinth due to low land area including supply of all materials, labour,T&P etc required for proper compltion of work.
439Construction Masonary type 1.0m x 1.0m Boring Chamber with Girder and Piller (0.45m x 0.45m)
440Excavation in foundation in ordinary soil (loam, clay and sand) including lift up to 1.5 m & lead upto 50 m refilling, watering and ramming of excavated earth into trenches or into the space between the building and sides of foundation trenches or into the plinth and disposal of surplus earth upto a distance of 50 m from the centre of foundation trenches.
441For Chamber
442For Pillers
443Concrete with 40mm guage brick ballast, local sand & cement in proportion of 8:4:1 in foundation, including supply of all materials, labour, T & P etc. required for proper completion of the work.
444For Chamber
445For Chamber
446For Pillers
447Ist class brick work in 1:6 cement and local sand mortar in foundation and plinth including supply of all materials, labour, T & P etc. required for proper completion of the work.
448For Chamber
449For Chamber
450R.C.C. Work with cement, coarse sand & 20 mm gauge approved stone ballast in proportion of 1:1.5:3 excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50 mm thick binding wire and the cost of binding wire and including necessary centering and shuttering supply of all materials, labour, T & P etc. required for proper completion of the work.
451Footings
452Pillers
453M.S. or iron work in plain work such as R.C.C. or R.B. work (when not included in over all rates) brought to required shape as necessary including bending for proper completion of the work including supply of steel and its wastage.
454Struck Pointing in 1:2 with Cement & Sand on Brick Work
455Chamber
456Chamber
45712 mm thick plaster with cement , coarse sand mortar in 1:6 (over brick work with 3 mm floating coat of neat cement including supply of all materials, labour,T&P etc required for proper compltion of work. From GL upto super structure.
458Painting and varnishing of new iron work with one coat priming and two coat of approved paint and varnish including supply of all materials, labour, T&P etc required for proper completion of work on Girder.
459Painting and varnishing of new iron work with one coat priming and two coat of approved paint and varnish including supply of all materials, labour, T&P etc required for proper completion of work on Girder.
460White washing with white cement in three coat including supply of all materials, labour, T&P etc required proper completion of work.
461Colour Painting with water proof apex paint in two coat over one primer coat including supply of all materials, labour, T&P etc required proper completion of work.
462Supply and fixing of Girder of 225mmx110mm size over the pump house including its painting with approved quality paint and also one priming coat.
463Boundary Wall
464Construction of Boundary wall around water works compound with 230mm thick, 1.60m height with 0.35x0.35 m R.C.C. Piller Boundary Wall in 1:6 Coarse sand and cement
465Extra Ist class brick work in 1:6 cement and coarse sand mortar in foundation and plinth due to low land area including supply of all materials, labour,T&P etc required for proper compltion of work.
466Fixing of 3.6m wide MS gate with 1.2m wide wicket gate Including fabrication and supply of steel and construction of boundary pillars etc. all complete.
467Supply and laying of 80mm thick Cement interlocking tiles for approach road including preparation of 100mm thick subgrade with lean concrete 1:4:8 including supply of all material, labour and T&P etc complete for proper completion of the work.
468Earth filling at various sites including supply of earth and all necessary labour and T&P etc. complete required for proper completion of work as per satisfaction of Engineer-in-charge.
469Provision for inside square drain including supply of all materials labour and T & P etc. complete.
470Recharge of ground water by Roof Top Rain Water of Pump house & Staff quarter, water available from bye pass of tubewell and over flow of over head tank as per drawing including supply of all materials, labour, T&P etc. complete.
471Construction of Rain Water Harvesting Chamber 5.50m x3.50x 1.80m with 02 Nos 110mm Dia, 20 mtr Deep Borewell in Water Works Campus.
472Construction of Rain Water Harvesting Chamber 1.66m x1.66x 1.80m with 01 Nos 110mm Dia, 20 mtr Deep Borewell in Campus of Proposed TW
473Landscaping, plantation work in water works campus.
474Repairig of Existing Boundary Wall
475Dismantling brick work or stone work in cement mortar in girder piller.
476Boundary Wall
477Dismantaling of old existing plaster from wall.
478Ist class brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour,T&P etc required for proper compltion of work.
479Boundary Wall
480Ist class brick work in super structure in 1 : 6 cement & coarse sand mortar.
481Boundary Wall
48212 mm thick plaster with cement , coarse sand mortar in 1:6 (over brick work with 3 mm floating coat of neat cement including supply of all materials, labour,T&P etc required for proper compltion of work. From GL upto super structure.
483White washing with white cement in three coat including supply of all materials, labour, T&P etc required proper completion of work.(SOR:1253)
484Colour Painting with water proof apex paint in two coat over one primer coat including supply of all materials, labour, T&P etc required proper completion of work.
485Master Control Room
486Construction of Master Control Station / SCADA Room including supply of all material, labour, T & P etc. required for proper completion of work as per Unit Estimate & Type Design and as per direction of Engineer-in-charge.
487Staff Quarter
488Construction of staff quarter/administrative building (13.25m x 11.95m) as per type departmental design and unit estimate with all labour, material T&P etc. complete and as per direction of Engineer-in-charge.
489E & M Works
490Construction of Tubewell New Tubewells- 26 Nos. ( Zone 1-02 No., Zone 5-01 No., Zone 6-01 No., Zone 7-01 No., Zone 9-04 No., Zone 10-04 No., Zone 11-03 No., Zone 12-03 No., Zone 13-03 No. & Zone 14-04 No.Rebore Tubewell- 01 No. ( Zone 5- 01 No.)
491Drilling of borehole for Tubewell contruction by DC/RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T&P complete in all respect including required all material, labour etc.
492Transportation, Erection and Dismantling of Rig Machine
493Drilling of 600mm size bore from GL to 60 BGL
494Drilling of 500mm size bore from
495(i) 60M BGL to 100MBGL
496(ii) 100M BGL to 150MBGL
497Tubewell Assembly
498M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect.
499300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm.
500200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm.
501Supply of pea gravel
502Logging of bore hole by departmental / approved electric logger.
503Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect.
504Lowering of 300mm dia pipe from GL to 54m deep BGL.
505Lowering of 200mm dia pipe from 54 to 100m deep BGL.
506Lowering of 200mm dia pipe from 100 to 135m deep BGL.
507Development of Tubewell by compressor
508Transportation, Installation and Dismantling of 250 PSI Compressor
509Development of Tubewell by 250 PSI Capacity Air compressor
510Development of Tubewell by O.P. Unit
511Transportation, Installation and Dismantling of 2 Cusec O.P. Unit & Yield Test.
512Development of Tubewell by 2 Cusec Capacity by O.P. Unit
513Chemical and Bacterological test of water sample from depaprtmental/ approved lab.
514Supply, installation, testing & comissioning of E&M works at Tubewells.
515SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc of following capacity. (Note- The given discharge and head are tentative and may vary according to actual site conditions and will be finalized after yeild test report & actual head during execution of work at site.)
516Zone-1
5171600 LPM, 37 head for New Tubewell
5181200 LPM, 35/37 head for Existing Tubewell
519Zone-2
5201650 LPM, 62m head for existing tubewell
521Zone-3
5221200 LPM, 57m head for existing tubewell
5231500 LPM, 59m head for existing tubewell
524Zone-4
5251500 LPM, 66m head for existing tubewell
526Zone-5
5271200 LPM, 60m head for existing tubewell
5281500 LPM, 62m head for New & Rebore tubewell
529Zone-6
5301600 LPM, 35/37m head for existing tubewell
5311600 LPM, 37m head for New tubewell
532Zone-7
5331200 LPM, 60/61m head for existing tubewell
5341500 LPM, 62m head for New tubewell
535Zone-9
5361500 LPM, 35m head for New tubewell
5371500 LPM, 37m head for New tubewell
538Zone-10
5391200 LPM, 37m head for Existing tubewell
5401500 LPM, 35m head for New tubewell
5411500 LPM, 37m head for New tubewell
542Zone-11
5431600 LPM, 65/67m head for New tubewell
544Zone-12
5451600 LPM, 65/67m head for New tubewell
546Zone-13
5471600 LPM, 65/67m head for New tubewell
548Zone-14
5491500 LPM, 35m head for New tubewell
5501500 LPM, 37m head for New tubewell
551Soft starters of following rating capacity
552Soft starter with RS-485 port-400V Class 22 Kw rating
553Soft starter with RS-485 port-400V Class 30 Kw rating
554Soft starter with RS-485 port-400V Class 15 Kw rating
55501 KVA UPS at TW Panel
556150 mm size motor operated actuator with Sluice valve (metal seated)
5573 Mtr. long heavy duty size 150mm dia column pipe same as above.
558CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm.
559CE & UL certified Inteligent Smart Energy Meter
560CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell.
561CE & UL certified pressure transmitter
562CE & UL certified Surge protector for above control panel
563CE & UL certified 7\\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.
564Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
565Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.)
566Auto Phase reversal unit with inbuilt time delay and enclosure (125 Amp.)
567Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT .
568Submersible flat Copper cable size 2x3cx6 sq mm.
569Submersible flat Copper cable size 2x3cx10 sq mm.
570Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter.
571Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx50 sq mm. from transformer LV side to meter panel and meter panel to starter.
572SITC of 03 Phase Servo Voltage Stabilizer 40 KVA
573SITC of 03 Phase Servo Voltage Stabilizer 30 KVA
574SITC of 03 Phase Servo Voltage Stabilizer 60 KVA
575SITC of 03 Phase Servo Voltage Stabilizer 50 KVA.
576Dismantaling of existing pumping plant
577SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system.
578Supply, installation, testing & comissioning of E&M works at CWR (Zone-1)
579Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 2800 LPM, 35 m head complete in all respect discharge head assembly and strainer with 6mtr/suitable length column pipe length coupled with 40 HP/Suitable rating VHS/VSS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 10% - 10% volts at speed 1460 RPM of following capacity.MOC : Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby.(Note- The given discharge and head are tentative and may vary according to actual site conditions and will be finalized after yeild test report & actual head during execution of work at site.)
580Soft starter with RS-485 port-400V Class 45 Kw rating
581Cast iron pipes & specials of suitable size.
582Supply of galvanized nut- Bolt SS-304 and rubber packing material for erection of above.
583DIDF Sluice Valve (metal seated) 200 mm with actuator
584DIDF double flanged single/multi door swing reflex valves PN 1.0/1.6 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of 200 mm dia size.
585DI Dismantling joints of following sizes.
586200 mm dia at pump outlet
587250 mm dia at common header
588Electrical operated Travelling Trolley (E.O.T) crane 4 way motion compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and double girder H-type etc.
589SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system.
590CE & UL certified Electomagnetic Flowmeter at common header size 250 mm. dia.
591L.T. Panel Board (Conforming to IEC-60439) suitable for operation on 400V, 3Phase 50 Hz. A.C. supply in 2mm thickness sheet steel enclosure (IP-54) in cubical pattern floor mounting with soft starters following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 60*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout type for 02 seperate Transformers incomer with indication lamp mechanical on/off indicator.03 Nos. Outgoing MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. 01 Nos. 63 Amps. MCCB for RTU/PLC Panel.01 Nos. 63 Amps. MCCB as Misc. load.02 Nos. 32 Amps. 4P MCCB for lighting & spare one.05 Nos. Multifunction meter with RS-485., Indicating lamps, cast resin CT, voltage protection/monitoring relay, selecter switch etc.
59201 No. required 30 KVAr/Suitable rating APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFC relay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99.
593Power and control cables
5941100 V grade, 3 core 50mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cable from LT panel to motor.(1x3x30 mtr.)
595Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathed Copper conductor cable for moisture sensor Reverse protection thermistor relay etc.
596EARTHING
597Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment (3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mm with salt and coal.
598Lighting system:
599Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height.
600S/F of 72 watt LED with lumen reflector.
601Feeder pillar for lighting
602Supply and laying of 4x16mm2 Al. armoured cable.
603Internal electrification with fixtures.
604S/F 1200 mm ceiling Fan for LT Room
605S/F of exhaust Fan for LT Room, VCB room.
606Earthing of street light pole (SOR-41)
607Painting of street light (P5-634)
608Supply and installation of DCP type of 5 Kg. Fire existinguisher (PS-1132)
60912 mm thick rubber mating for safe working on.
610Tools
611Hydrulic crimping tools-Crimping range: 16-300 sq.mm.,Weight: 6 Kg. ,Length: 500mm,Make/ Model:YQK300
612Mannual crimping tools-Crimping range: 400 sq.mm.,Make/ Model: Crimp well
613Tong tester (AC/DC-1000A, make-Rishabh)Multimeter (AC/DC-1000A, make-Meco)Megger (AC/DC-500V make-Rishabh)Screwdriver (6\\"x 12\\", make- Taparia)Plier (250mm, make-Taparia)
614Chain wrench (12\\"x18\\", make Taparia) Pipe wrench (1200mm, make Taparia)
615CE / UL approved manufacturer’s Radar type Level Transmitter for CWR as specified in tender technical specification sheet
616CE / UL approved manufacturer’s Pressure Transmitter in main header line of Pump and for each pump as per specifications specified in tender technical specification sheet.
617CE & UL certified Surge protector for control panel
618CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations.
619G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges.
620CE & UL certified 7\\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.
621Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
622Complete cabling for ZPS including all power and control cable of all equipments at ZPS
623Security Surveillance IP Camera with Recorer
624Installation, testing & commissioning of pumping plants and Panels etc. complete
625Chequered plate of required size so as to cover all trenches.
626Power Distribution Transformer :
627Supply of Oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 160 KVA double wound with copper winding, Level-1, vector group dyn 11, ONAN with manually operated ± 7.50 % off load tap changer in step of 2.5% and complete with standard fitting & accessories.
628Supply and laying of 1100 voltage grade ,1Rx3.5Cx 185 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel.
629Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers.
630Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER.
631S/F of XLPE cable End termination box
632Indoor end termination box.
633Earthing of H.T Panel as per IS & IER.
634Supply of 12 KV, H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating.Incommer Feeder- 01 No.3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc. C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20 & volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC.Outgoing Feeder- 02 Nos.outgoing feeder control panel equiped with triple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc. C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core.DC Supply SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc.
635CE/UL approved manufacturer's Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. as per spec mentioned in technical bid documents.
636Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch with inbuilt time delay & enclosure of Suitable Ampere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1) as specified in tender technical specification sheet.250amp
637Installation , testing and Commissioning of Transformer and all associated sub station equipments etc. complete in all respect with 1.50 Mtr. Height MS Jali fancing and stone grit etc. confiroming to relevent IS code and IER.
638Supply, installation, testing & comissioning of E&M works at CWR (Zone-6)
639Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 3200 LPM, 33 m head complete in all respect discharge head assembly and strainer with 6mtr/suitable length column pipe length coupled with 40 HP/Suitable rating VHS/VSS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 10% - 10% volts at speed 1460 RPM of following capacity.MOC : Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby.(Note- The given discharge and head are tentative and may vary according to actual site conditions and will be finalized after yeild test report & actual head during execution of work at site.)
640Soft starter with RS-485 port-400V Class 45 Kw rating
641Cast iron pipes & specials of suitable size.
642Supply of galvanized nut- Bolt SS-304 and rubber packing material for erection of above.
643DIDF Sluice Valve (metal seated) 200 mm with actuator
644DIDF double flanged single/multi door swing reflex valves PN 1.0/1.6 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of 200 mm dia size.
645DI Dismantling joints of following sizes.
646200 mm dia at pump outlet
647250 mm dia at common header
648Electrical operated Travelling Trolley (E.O.T) crane 4 way motion compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and double girder H-type etc.
649SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system.
650CE & UL certified Electomagnetic Flowmeter at common header size 250 mm. dia.
651L.T. Panel Board (Conforming to IEC-60439) suitable for operation on 400V, 3Phase 50 Hz. A.C. supply in 2mm thickness sheet steel enclosure (IP-54) in cubical pattern floor mounting with soft starters following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 60*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout type for 02 seperate Transformers incomer with indication lamp mechanical on/off indicator.03 Nos. Outgoing MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. 01 Nos. 63 Amps. MCCB for RTU/PLC Panel.01 Nos. 63 Amps. MCCB as Misc. load.02 Nos. 32 Amps. 4P MCCB for lighting & spare one.05 Nos. Multifunction meter with RS-485., Indicating lamps, cast resin CT, voltage protection/monitoring relay, selecter switch etc.
65201 No. required 30 KVAr/Suitable rating APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFC relay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99.
653Power and control cables
6541100 V grade, 3 core 50mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cable from LT panel to motor.(1x3x30 mtr.)
655Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathed Copper conductor cable for moisture sensor Reverse protection thermistor relay etc.
656EARTHING
657Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment (3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mm with salt and coal.
658Lighting system:
659Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height.
660S/F of 72 watt LED with lumen reflector.
661Feeder pillar for lighting
662Supply and laying of 4x16mm2 Al. armoured cable.
663Internal electrification with fixtures.
664S/F 1200 mm ceiling Fan for LT Room
665S/F of exhaust Fan for LT Room, VCB room.
666Earthing of street light pole (SOR-41)
667Painting of street light (P5-634)
668Supply and installation of DCP type of 5 Kg. Fire existinguisher (PS-1132)
66912 mm thick rubber mating for safe working on.
670CE / UL approved manufacturer’s Radar type Level Transmitter for CWR as specified in tender technical specification sheet
671CE / UL approved manufacturer’s Pressure Transmitter in main header line of Pump and for each pump as per specifications specified in tender technical specification sheet.
672CE & UL certified Surge protector for control panel
673CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations.
674G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges.
675CE & UL certified 7\\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.
676Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
677Complete cabling for ZPS including all power and control cable of all equipments at ZPS
678Security Surveillance IP Camera with Recorer
679Installation, testing & commissioning of pumping plants and Panels etc. complete
680Chequered plate of required size so as to cover all trenches.
681Power Distribution Transformer :
682Supply of Oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 160 KVA double wound with copper winding, Level-1, vector group dyn 11, ONAN with manually operated ± 7.50 % off load tap changer in step of 2.5% and complete with standard fitting & accessories.
683Supply and laying of 1100 voltage grade ,1Rx3.5Cx 185 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel.
684Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers.
685Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER.
686S/F of XLPE cable End termination box
687Indoor end termination box.
688Earthing of H.T Panel as per IS & IER.
689Supply of 12 KV, H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating.Incommer Feeder- 01 No.3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc. C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20 & volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC.Outgoing Feeder- 02 Nos.outgoing feeder control panel equiped with triple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc. C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core.DC Supply SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc.
690CE/UL approved manufacturer's Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. as per spec mentioned in technical bid documents.
691Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch with inbuilt time delay & enclosure of Suitable Ampere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1) as specified in tender technical specification sheet.250amp
692Installation , testing and Commissioning of Transformer and all associated sub station equipments etc. complete in all respect with 1.50 Mtr. Height MS Jali fancing and stone grit etc. confiroming to relevent IS code and IER.
693Supply, installation, testing & comissioning of E&M works at CWR (Zone-9)
694Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 3000 LPM, 38 m head complete in all respect discharge head assembly and strainer with 6mtr/suitable length column pipe length coupled with 50 HP/Suitable rating VHS/VSS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 10% - 10% volts at speed 1460 RPM of following capacity.MOC : Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby.(Note- The given discharge and head are tentative and may vary according to actual site conditions and will be finalized after yeild test report & actual head during execution of work at site.)
695Soft starter with RS-485 port-400V Class 45 Kw rating
696Cast iron pipes & specials of suitable size.
697Supply of galvanized nut- Bolt SS-304 and rubber packing material for erection of above.
698DIDF Sluice Valve (metal seated) 200 mm with actuator
699DIDF double flanged single/multi door swing reflex valves PN 1.0/1.6 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of 200 mm dia size.
700DI Dismantling joints of following sizes.
701200 mm dia at pump outlet
702250 mm dia at common header
703Electrical operated Travelling Trolley (E.O.T) crane 4 way motion compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and double girder H-type etc.
704SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system.
705CE & UL certified Electomagnetic Flowmeter at common header size 250 mm. dia.
706L.T. Panel Board (Conforming to IEC-60439) suitable for operation on 400V, 3Phase 50 Hz. A.C. supply in 2mm thickness sheet steel enclosure (IP-54) in cubical pattern floor mounting with soft starters following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 60*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout type for 02 seperate Transformers incomer with indication lamp mechanical on/off indicator.03 Nos. Outgoing MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. 01 Nos. 63 Amps. MCCB for RTU/PLC Panel.01 Nos. 63 Amps. MCCB as Misc. load.02 Nos. 32 Amps. 4P MCCB for lighting & spare one.05 Nos. Multifunction meter with RS-485., Indicating lamps, cast resin CT, voltage protection/monitoring relay, selecter switch etc.
70701 No. required 30 KVAr/Suitable rating APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFC relay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99.
708Power and control cables
7091100 V grade, 3 core 50mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cable from LT panel to motor.(1x3x30 mtr.)
710Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathed Copper conductor cable for moisture sensor Reverse protection thermistor relay etc.
711EARTHING
712Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment (3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mm with salt and coal.
713Lighting system:
714Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height.
715S/F of 72 watt LED with lumen reflector.
716Feeder pillar for lighting
717Supply and laying of 4x16mm2 Al. armoured cable.
718Internal electrification with fixtures.
719S/F 1200 mm ceiling Fan for LT Room
720S/F of exhaust Fan for LT Room, VCB room.
721Earthing of street light pole (SOR-41)
722Painting of street light (P5-634)
723Supply and installation of DCP type of 5 Kg. Fire existinguisher (PS-1132)
72412 mm thick rubber mating for safe working on.
725CE / UL approved manufacturer’s Radar type Level Transmitter for CWR as specified in tender technical specification sheet
726CE / UL approved manufacturer’s Pressure Transmitter in main header line of Pump and for each pump as per specifications specified in tender technical specification sheet.
727CE & UL certified Surge protector for control panel
728CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations.
729G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges.
730CE & UL certified 7\\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.
731Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
732Complete cabling for ZPS including all power and control cable of all equipments at ZPS
733Security Surveillance IP Camera with Recorer
734Installation, testing & commissioning of pumping plants and Panels etc. complete
735Chequered plate of required size so as to cover all trenches.
736Power Distribution Transformer :
737Supply of Oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 200 KVA double wound with copper winding, Level-1, vector group dyn 11, ONAN with manually operated ± 7.50 % off load tap changer in step of 2.5% and complete with standard fitting & accessories.
738Supply and laying of 1100 voltage grade ,1Rx3.5Cx 185 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel.
739Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers.
740Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER.
741S/F of XLPE cable End termination box
742Indoor end termination box.
743Earthing of H.T Panel as per IS & IER.
744Supply of 12 KV, H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating.Incommer Feeder- 01 No.3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc. C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20 & volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC.Outgoing Feeder- 02 Nos.outgoing feeder control panel equiped with triple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc. C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core.DC Supply SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc.
745CE/UL approved manufacturer's Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. as per spec mentioned in technical bid documents.
746Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch with inbuilt time delay & enclosure of Suitable Ampere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1) as specified in tender technical specification sheet.250amp
747Installation , testing and Commissioning of Transformer and all associated sub station equipments etc. complete in all respect with 1.50 Mtr. Height MS Jali fancing and stone grit etc. confiroming to relevent IS code and IER.
748Supply, installation, testing & comissioning of E&M works at CWR (Zone-10)
749Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 3600 LPM, 38 m head complete in all respect discharge head assembly and strainer with 6mtr/suitable length column pipe length coupled with 50 HP/Suitable rating VHS/VSS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 10% - 10% volts at speed 1460 RPM of following capacity.MOC : Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby.(Note- The given discharge and head are tentative and may vary according to actual site conditions and will be finalized after yeild test report & actual head during execution of work at site.)
750Soft starter with RS-485 port-400V Class 45 Kw rating
751Cast iron pipes & specials of suitable size.
752Supply of galvanized nut- Bolt SS-304 and rubber packing material for erection of above.
753DIDF Sluice Valve (metal seated) 200 mm with actuator
754DIDF double flanged single/multi door swing reflex valves PN 1.0/1.6 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of 200 mm dia size.
755DI Dismantling joints of following sizes.
756200 mm dia at pump outlet
757250 mm dia at common header
758Electrical operated Travelling Trolley (E.O.T) crane 4 way motion compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and double girder H-type etc.
759SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system.
760CE & UL certified Electomagnetic Flowmeter at common header size 250 mm. dia.
761L.T. Panel Board (Conforming to IEC-60439) suitable for operation on 400V, 3Phase 50 Hz. A.C. supply in 2mm thickness sheet steel enclosure (IP-54) in cubical pattern floor mounting with soft starters following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 60*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout type for 02 seperate Transformers incomer with indication lamp mechanical on/off indicator.03 Nos. Outgoing MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. 01 Nos. 63 Amps. MCCB for RTU/PLC Panel.01 Nos. 63 Amps. MCCB as Misc. load.02 Nos. 32 Amps. 4P MCCB for lighting & spare one.05 Nos. Multifunction meter with RS-485., Indicating lamps, cast resin CT, voltage protection/monitoring relay, selecter switch etc.
76201 No. required 30 KVAr/Suitable rating APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFC relay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99.
763Power and control cables
7641100 V grade, 3 core 50mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cable from LT panel to motor.(1x3x30 mtr.)
765Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathed Copper conductor cable for moisture sensor Reverse protection thermistor relay etc.
766EARTHING
767Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment (3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mm with salt and coal.
768Lighting system:
769Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height.
770S/F of 72 watt LED with lumen reflector.
771Feeder pillar for lighting
772Supply and laying of 4x16mm2 Al. armoured cable.
773Internal electrification with fixtures.
774S/F 1200 mm ceiling Fan for LT Room
775S/F of exhaust Fan for LT Room, VCB room.
776Earthing of street light pole (SOR-41)
777Painting of street light (P5-634)
778Supply and installation of DCP type of 5 Kg. Fire existinguisher (PS-1132)
77912 mm thick rubber mating for safe working on.
780CE / UL approved manufacturer’s Radar type Level Transmitter for CWR as specified in tender technical specification sheet
781CE / UL approved manufacturer’s Pressure Transmitter in main header line of Pump and for each pump as per specifications specified in tender technical specification sheet.
782CE & UL certified Surge protector for control panel
783CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations.
784G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges.
785CE & UL certified 7\\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.
786Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
787Complete cabling for ZPS including all power and control cable of all equipments at ZPS
788Security Surveillance IP Camera with Recorer
789Installation, testing & commissioning of pumping plants and Panels etc. complete
790Chequered plate of required size so as to cover all trenches.
791Power Distribution Transformer :
792Supply of Oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 200 KVA double wound with copper winding, Level-1, vector group dyn 11, ONAN with manually operated ± 7.50 % off load tap changer in step of 2.5% and complete with standard fitting & accessories.
793Supply and laying of 1100 voltage grade ,1Rx3.5Cx 185 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel.
794Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers.
795Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER.
796S/F of XLPE cable End termination box
797Indoor end termination box.
798Earthing of H.T Panel as per IS & IER.
799Supply of 12 KV, H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating.Incommer Feeder- 01 No.3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc. C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20 & volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC.Outgoing Feeder- 02 Nos.outgoing feeder control panel equiped with triple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc. C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core.DC Supply SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc.
800CE/UL approved manufacturer's Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. as per spec mentioned in technical bid documents.
801Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch with inbuilt time delay & enclosure of Suitable Ampere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1) as specified in tender technical specification sheet.250amp
802Installation , testing and Commissioning of Transformer and all associated sub station equipments etc. complete in all respect with 1.50 Mtr. Height MS Jali fancing and stone grit etc. confiroming to relevent IS code and IER.
803Supply, installation, testing & comissioning of E&M works at CWR (Zone-14)
804Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 3000 LPM, 38 m head complete in all respect discharge head assembly and strainer with 6mtr/suitable length column pipe length coupled with 50 HP/Suitable rating VHS/VSS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 10% - 10% volts at speed 1460 RPM of following capacity.MOC : Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby.(Note- The given discharge and head are tentative and may vary according to actual site conditions and will be finalized after yeild test report & actual head during execution of work at site.)
805Soft starter with RS-485 port-400V Class 45 Kw rating
806Cast iron pipes & specials of suitable size.
807Supply of galvanized nut- Bolt SS-304 and rubber packing material for erection of above.
808DIDF Sluice Valve (metal seated) 200 mm with actuator
809DIDF double flanged single/multi door swing reflex valves PN 1.0/1.6 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of 200 mm dia size.
810DI Dismantling joints of following sizes.
811200 mm dia at pump outlet
812250 mm dia at common header
813Electrical operated Travelling Trolley (E.O.T) crane 4 way motion compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and double girder H-type etc.
814SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system.
815CE & UL certified Electomagnetic Flowmeter at common header size 250 mm. dia.
816L.T. Panel Board (Conforming to IEC-60439) suitable for operation on 400V, 3Phase 50 Hz. A.C. supply in 2mm thickness sheet steel enclosure (IP-54) in cubical pattern floor mounting with soft starters following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 60*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout type for 02 seperate Transformers incomer with indication lamp mechanical on/off indicator.03 Nos. Outgoing MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. 01 Nos. 63 Amps. MCCB for RTU/PLC Panel.01 Nos. 63 Amps. MCCB as Misc. load.02 Nos. 32 Amps. 4P MCCB for lighting & spare one.05 Nos. Multifunction meter with RS-485., Indicating lamps, cast resin CT, voltage protection/monitoring relay, selecter switch etc.
81701 No. required 30 KVAr/Suitable rating APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFC relay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99.
818Power and control cables
8191100 V grade, 3 core 50mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cable from LT panel to motor.(1x3x30 mtr.)
820Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathed Copper conductor cable for moisture sensor Reverse protection thermistor relay etc.
821EARTHING
822Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment (3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mm with salt and coal.
823Lighting system:
824Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height.
825S/F of 72 watt LED with lumen reflector.
826Feeder pillar for lighting
827Supply and laying of 4x16mm2 Al. armoured cable.
828Internal electrification with fixtures.
829S/F 1200 mm ceiling Fan for LT Room
830S/F of exhaust Fan for LT Room, VCB room.
831Earthing of street light pole (SOR-41)
832Painting of street light (P5-634)
833Supply and installation of DCP type of 5 Kg. Fire existinguisher (PS-1132)
83412 mm thick rubber mating for safe working on.
835Inatallation, testing & commissioning of pumping plants and Panels etc. complete
836Chequered plate of required size so as to cover all trenches.
837Power Distribution Transformer :
838Supply of Oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 200 KVA double wound with copper winding, Level-1, vector group dyn 11, ONAN with manually operated ± 7.50 % off load tap changer in step of 2.5% and complete with standard fitting & accessories.
839Supply and laying of 1100 voltage grade ,1Rx3.5Cx 185 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel.
840Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers.
841Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER.
842S/F of XLPE cable End termination box
843Indoor end termination box.
844Earthing of H.T Panel as per IS & IER.
845Supply of 12 KV, H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating.Incommer Feeder- 01 No.3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc. C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20 & volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC.Outgoing Feeder- 02 Nos.outgoing feeder control panel equiped with triple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc. C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core.DC Supply SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc.
846CE/UL approved manufacturer's Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. as per spec mentioned in technical bid documents.
847Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch with inbuilt time delay & enclosure of Suitable Ampere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1) as specified in tender technical specification sheet.250amp
848CE / UL approved manufacturer’s Radar type Level Transmitter for CWR as specified in tender technical specification sheet
849CE / UL approved manufacturer’s Pressure Transmitter in main header line of Pump and for each pump as per specifications specified in tender technical specification sheet.
850CE & UL certified Surge protector for control panel
851CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations.
852G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges.
853CE & UL certified 7\\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter.
854Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments)
855Complete cabling for ZPS including all power and control cable of all equipments at ZPS
856Security Surveillance IP Camera with Recorer
857Installation , testing and Commissioning of Transformer and all associated sub station equipments etc. complete in all respect with 1.50 Mtr. Height MS Jali fancing and stone grit etc. confiroming to relevent IS code and IER.
858Supply, installation, testing & comissioning of E&M works at OHTs.
859Motor operated Actuators with Sluice valve (metal seated) of following sizes.
860300 mm.dia size at distribution line.
861350 mm.dia size at distribution line.
862400 mm. dia size at distribution line.
863450 mm. dia size at distribution line.
864500 mm. dia size at distribution line.
865CE & UL certified Full bore Electomagnetic Flowmeter at OHT distribution line of following sizes.
866300 mm.dia size at distribution line.
867350 mm.dia size at distribution line.
868400 mm. dia size at distribution line.
869450 mm. dia size at distribution line.
870500 mm. dia size at distribution line.
871DI Dismantling joints of following sizes.
872150 mm.dia size at tubewell delivery line.
873300 mm.dia size at distribution line.
874350 mm.dia size at distribution line.
875400 mm. dia size at distribution line.
876450 mm. dia size at distribution line.
877500 mm. dia size at distribution line.
878Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator.
879CE/UL Certified suitable capacity UPS with batteries. (3 Phase incomming & 3 phase output for operating OHT outlet sluice valve.)
880CE & UL certified Radar type level transmitter for OHT
881SITC Booster pump set 645 m3/hr & differential head 8mt including Valve, pressure gauge, VFD, control panel, controller, power cable, pressure transmeter & dry run protection float sheets complete with required automation in all respect flow of single pump 322.5 m3/hr with 11 KW motor. (2w+1s) at Zone-2
882SITC Booster pump set 460 m3/hr & differential head 9 mt including Valve, pressure gauge, VFD, control panel, controller, power cable, pressure transmeter & dry run protection float sheets complete with required automation in all respect flow of single pump 230 m3/hr with 9.3 KW motor. (2w+1s) for (DMA-1&2) at Zone-3
883SITC Booster pump set 238 m3/hr & differential head 13 mt including Valve, pressure gauge, VFD, control panel, controller, power cable, pressure transmeter & dry run protection float sheets complete with required automation in all respect flow of single pump 238 m3/hr with 15 KW motor. (1w+1s) at Zone-4
884SITC Booster pump set 347 m3/hr & differential head 12 mt including Valve, pressure gauge, VFD, control panel, controller, power cable, pressure transmeter & dry run protection float sheets complete with required automation in all respect flow of single pump 173.5 m3/hr with 11 KW motor. (2w+1s) at Zone-5
885SITC Booster pump set 454 m3/hr & differential head 10 mt including Valve, pressure gauge, VFD, control panel, controller, power cable, pressure transmeter & dry run protection float sheets complete with required automation in all respect flow of single pump 227 m3/hr with 9.3 KW motor. (2w+1s) at Zone-7
886SITC Booster pump set 196 m3/hr & differential head 14 mt including Valve, pressure gauge, VFD, control panel, controller, power cable, pressure transmeter & dry run protection float sheets complete with required automation in all respect flow of single pump 196 m3/hr with 15 KW motor. (1w+1s) for DMA-1 at Zone-10
887SITC Booster pump set 632 m3/hr & differential head 9 mt including Valve, pressure gauge, VFD, control panel, controller, power cable, pressure transmeter & dry run protection float sheets complete with required automation in all respect flow of single pump 316 m3/hr with 15 KW motor. (2w+1s) at Zone-11
888Trail & Run for 03 months of scheme complete with all OHTs, CWRs & MCS with required staff and recharges (without electricity charges)
889MASTER CONTROL CENTERE (MCS)
890CE/UL & BIS Certifed industrial grade LED MONITOR with latest configuration of 65\\"
891Desktop/PC with 32 inch moniter/laptop with i7 processor having 12 GB ram and 1 TB ssd
892CE/UL Certified 3 KVA UPS with batteries .
893Full development version of required TAGS SCADA Software with coustomization of sowftware for MCS as per requirement .
894CE/UL Certified master control room PLC with redundant CPU & power supply at MCS in IP54 enclouser
895CE/UL Certified Field gateway agent for transfering data from MCS to Central control room.
896GSM based wireless/Broaband/Equipment communication system for PLC capable to transfer & received data & gather data from remote sites to control satation, All accessories included signal enhancer antenna along with running expences.
897CE/UL Certified Firewall for network protection.
898SURGE PROTECTOR FOR ETHERNET communication protection.
899CE/UL certified industrial grade Ethernet Switch.
900Mobile App Facility system architecture (industries internet based & viewed through mobile apps for increased local & Remote Visibility) with mobile.
901Canon/HP or equivalent Laser Printer 1018 or equivement.
902PVC panelling
903Security Sureillance IP camera with recorder
904Installion, Commissioning & testing including required furniture, A/c etc for MCS room
905Desktop/PC with i7 processor 12 Gb ram & 1 TB SSD and 32 inch moniter with licence MS office for the office
906Cannon/HP printer black & white having both side printing facility for the office
907Cartridge rifilling of above printer for the office
908CE/UL Certified 15 KVA single phase UPS with batteries having 1 hrs backup for the office
909Computer table & revolving chair branded for the office
9101.5 Ton split AC BEE 3 star rated with voltage stabilizer for the office
911Techmint X Digital Board 65 inch with smart pen, camera, mic etc. for the office
912Multirack, multifunction colour photocopy machine having top load scanner, wifi and A3 printing facility complete with 2 year AMC and refilling/cartrige replacement upto 2 year make cannon/HP/sharp/brother
913SCADA/Automation of all Tubewells for all zones.(B/O items)
914CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations.
915G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges.
916Installation, commissioning & testing at tubewells
917Trail & Run for 03 months of Tubewells (without electricity charges)
918Supply & filling of sodium Hypochloride for 03 Months trail & run Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56726383
AUTHORITY Government Departments
TENDER VALUE 123.65 Crore
LAST DATE 13-08-2026
Authority
Authority Name Uttar Pradesh Jal Nigam
Work Description Tender for Sambhal Water Supply Reorganization Scheme Under Amrut 2.0
Basic Detail
Tender No 1139/Nivida/156 date 27.07.2026
Bidding Type Tender
Location
City Sambhal
State Uttar Pradesh
Key Dates
Publish Date 29 Jul 2026
Submission Date 13 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 123.65 Crore
Tender Fee 23600
EMD 1.23 Crore
Exemption Not Available
Document List
BOQ_2203402.xls
e1597ff5-24c5-4a20-bab7-702b6aa44abe.html
tenderdocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2203402.xls

html

e1597ff5-24c5-4a20-bab7-702b6aa44abe.html

pdf

tenderdocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders