Housing Urban and Rular Development Local Bodies Closing in 4 days TDR #56726378

Tender For O/M Of Stp (Two Year Repairing And Rewinding Of 75/90 And 150 Hp Submersible Pump, Panel Starter And Repair Of Sluice And Reflex Valve In Pumping Station At Ugr-168) Noida

Issued by Local Bodies · Ghaziabad, Uttar Pradesh
Tender Value
40.70 Lakhs
Estimated cost
Bid Submission
04 Aug 2026
4 days left
EMD
96100
Bank guarantee accepted
Document Fee
2124
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for O/M Of Stp (Two Year Repairing And Rewinding Of 75/90 And 150 Hp Submersible Pump, Panel Starter And Repair Of Sluice And Reflex Valve In Pumping Station At Ugr-168) Noida

BOQ

Name of Work:- O/M of STP (Two Year Repairing and Rewinding of 75/90 and 150 HP Submersible Pump, Panel Starter and repair of Sluice and Reflex valve in Pumping Station at UGR-168) Noida
Sl. No. Item Description
1Repair/Rewinding of 75 HP Non Clog submersible sewage motor pump Motor Rewinding with F class insulation
2Winding thermostat 140+5 on/off auto cut
3S/F of Upper mechanical seal
4S/F of Lower mechanical seal
5S/F Cable protector
6S/F O Ring
7S/F of Oil
8Fasteners Set
9Profile Gasket
10S/F DI Impeller
11Nilos Ring
12Spring Washer
13Plan head screw
14Motor pump dismantling, assembling i/c labour charge
15Repair/Rewinding of 150 HP Non Clog submersible sewage motor pump MOTOR Motor Rewinding with F class insulation
16Winding thermostat 140+5 on/off auto cut
17S/F of Upper mechanical seal
18S/F of Lower mechanical seal
19S/F Cable protector
20S/F O Ring
21S/F of Oil
22S/F Terminal Block
23S/F Spring Washer
24S/F Cir clip
25S/F Adjustment Screw
26S/F Top Cover
27S/F Bottom plate
28S/F D.I. Impeller
29Motor pump dismantling, assembling i/c labour charge
30Repairing of fully Automatic Starter 75 HP as per following S/F of MNX X 185 Amp, Contactor L&T make
31S/F of 250 Amp, MCCB L&T make
32S/F of Timer L&T make
33S/F of VPD Make Soft Hard
34S/F of MPD Make Soft Hard
35WLC/Seal Monitor, Make Pump Care/Kishor
36S/F of Control Transformer Make Electra Care/Pioneer
37S/F Winding Temp. Relay Minilic Make
38Auto Transformer suitable for 75 HP Induction Motor
39Repairing of fully Automatic Starter 100 HP as per following S/F of MNX X 225 Amp, Contactor L&T make
40S/F of 250 Amp, MCCB L&T make
41S/F of Timer L&T make
42S/F of VPD Make Soft Hard
43S/F of MPD Make Soft Hard
44WLC/Seal Monitor, Make Pump Care/Kishor
45S/F of Control Transformer Make Electra Care/Pioneer
46S/F Winding Temp. Relay Minilic Make
47Auto Transformer suitable for 100 HP Induction Motor
48P/F M.S. specials such as Tee , Bends , Collars , Tapers, Gap pieces,including Flange Ends as required , Painting ,Cutting, welding as per site requirement of MS pipe thickness etc complete in all respect as per direction of E/I.
49Repairing of sluice valve Kirlosker Make/ISI make new of spendle (i.e. S.S. non megnated) flapper adjusting nut, bolts,rod, welding of body for fitting the flapper for Proper complete of work in all respects as per direction of E/I. 150 mm dia
50200 mm dia
51250 mm dia
52300 mm dia
53400 mm dia
54600 mm dia
55Repairing of Reflex valve Kirlosker Make/ISI make new of spendle (i.e. S.S. non megnated) flapper adjusting nut, bolts,rod, welding of body for fitting the flapper for Proper complete of work in all respects as per direction of E/I. 150 mm dia
56200 mm dia
57250 mm dia
58300 mm dia
59400 mm dia
60600 mm dia
61Hiring of Welding Set Running Time @ 6 Hrs/Day (Including Service cost of operating staff, supply of suitable electrodes etc).
62Hiring of Gas cutting set with oxygen and LPG Running time @ 6 Hrs/Day (Including Service cost of operating staff, supply of necessory items as oxygen & LPG etc).
63Supply and laying aluminum conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 240 sq.mm 3-1/2 core
64185 sq.mm 3-1/2 core
65120 sq.mm 3-1/2 core
6670 sq.mm 3-1/2 core
67Supply and fixing of plain or pin type copper tin plated cable socket ( lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 Sqmm
68185 sqmm
69120 sqmm
7070 sqmm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56726378
AUTHORITY Local Bodies
TENDER VALUE 40.70 Lakhs
LAST DATE 04-08-2026
Authority
Authority Name New Okhla Industrial Development Authority
Work Description Tender for O/M Of Stp (Two Year Repairing And Rewinding Of 75/90 And 150 Hp Submersible Pump, Panel Starter And Repair Of Sluice And Reflex Valve In Pumping Station At Ugr-168) Noida
Basic Detail
Tender No 02/SM(JAL-OA)/26-27
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 29 Jul 2026
Submission Date 04 Aug 2026
Open Date 05 Aug 2026
Finance
Tender Value 40.70 Lakhs
Tender Fee 2124
EMD 96100
Exemption Available
Document List
BOQ_2203387.xls
C.xls
cbfa1dea-a442-4ddf-bba9-0d4bd54a46c9.html
TD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2203387.xls

xls

C.xls

html

cbfa1dea-a442-4ddf-bba9-0d4bd54a46c9.html

pdf

TD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders