Heavy Industries and Public Enterprises Government Departments Closing in 12 days TDR #56726240

Tender For Special Repairs To Walls And Floors Of Qa(Ga) Labs, Provision Of Tank Parking Shed And Roof Covering For Northern Side Washing R In Ga Shop At New Facility, Hvf, Avadi.

Issued by Government Departments · Thiruvallur, Tamil Nadu
Tender Value
3.02 Crore
Estimated cost
Bid Submission
13 Aug 2026
12 days left
EMD
3.78 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Walls And Floors Of Qa(Ga) Labs, Provision Of Tank Parking Shed And Roof Covering For Northern Side Washing R In Ga Shop At New Facility, Hvf, Avadi.

BOQ

Name of Work:- SPECIAL REPAIRS TO WALLS AND FLOORS OF QA(GA) LABS, PROVISION OF TANK PARKING SHED AND ROOF COVERING FOR NORTHERN SIDE WASHING R IN GA SHOP AT NEW FACILITY, HVF, AVADI.
Sl. No. Item Description
1Dismantling of false ceiling boards(fibre, pulp, insulation etc.,) or insulation boards/slabs. blankets of any thickness inculding aluminium snap grid and removing to CE Stores as directed.
2Dismantling structural steel work including doors, gates and windows etc complete.,and removing to CE Stores as directed.
3Supply and Fixing of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe 410-W(GdeE- 250)qualityA
4Fixing of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
5Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The Steel sheet shall be galvanized (AZ-150 gms Aluminum Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS:875-1987, ISO 800-1984 and IS:801-1975. The wind load shall be as per provisions of IS 875(part-III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/STAAD PRO- V8i/ArchiteKV2.5.16/Revit architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/slot at required locations as per approved drawings. The slots will be along center line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self-drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 and 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self-expanding carbon steel anchor bolt of dia as per approved drawings and design subject to minimum 12 mm diameter and 121 mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT. The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
6Dismanling of aluminium parttion by carefully removing glass and particle board from its position as directed and depositioning to CE stores.
7Material and Labour for forming jambs using CM 1:4 to opening including cutting, toothing and also facing, jointing and pointing to match existing work complete.
8Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L- shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge (a) With Semi perforated 12mm thick micro tegular edged GRG false ceiling tiles
9Providing and fixing factory made uPVG white colourSliding window Three track made of extruded profileswith wall thickness of 2.3mm (+/ -0.2mm). Windowprofile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 +/ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.(B) area exc 2.00 Sqm each) and as approved and as directed.
10Supply and Fixing of sheet Glass 5.50mm quality and glazing with oil putty in square exc 0.5Sqm in each pane.
11Supply & fixing of powder coated anodised aluminium frame for partition,doors, windows, ventilators with one or more rebates including joining cleat for fixing and power coating etc. (minimum thickness of powder coating 50 micron). complete all as specified.
12M&L for pre-laminated particle board of 12 mm thick with both sides with decorative choice lamination.
13Supply and Fixing of Solar control film 25 micron reflective type sticked to glass panes as perinstructions of manufacturers
14Material and labour for moorum/red brij/quarry dust filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering.
15Supply and fixing of 3 mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors.
16Supply and Fixing of Rubber sheet 5mm thick with fabric backing or insert and plain coloured or marbled topping, matt or glossy, laid in floors with approved adhesive as directed and approved.
17Material and labour for brick work built in CM 1:6 using sub-class ''B'' bricks ,straight or curved on plain exc 6m mean radius.
18M&L for Plastering with 1:4,15mm thick on faces of brick work and concrete surfaces.
19S & F of 2nd class hardwood plain,solid ,straight ,chowkats, and frames ,wrought,framed rebated on the solid ,rounded or chamfered,put together with glue pinned at joints, supplied and fixed.
20Supply and fixing of 40mm Flush shutters solid board construction with Partical board core and plywood face panels, commercial type on both sides and both faces is covered with decorative face venner with lipping/frame to match.
21S/F of Mortice lock,vertical type, size 100 mm )with four levers, Brass body and fixed .
22S/F of Brass barrel tower bolts, (100 mm )with cast or sheet barrel and rolled or cast bolts and fixed
23S/F of butt hinges (125mm) cast, brass with mild steel hinge pin,bright polished and fixed but type B-12.
24S/F of Brass skeleton tower bolts (450 MM) with cast brass plate and staples and rolled or drawn brass bolt and fixed.
25S/F of Floor door stopper of brass body Overall length of cover plate (140 mm)and tongue, anodised,with hard drawn steel spring,fixed in floor.
26Supply and fixing of extructed brass handles fabricated and polished of size 150m
27Supply and Fixing of Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed.
28Supply and fixing of Aluminium(extruded section ) body Door closer hydraulically regulated,designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed .
29Material and labour for French polishing on surfaces of any description,width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats.
30Taking down door shutter exceeding 2 Sq.M from position and removing and depostion in CE Stores.
31Demolition of brickwork or stone/boulder masonery, built in cement motar.
32M &L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer in CM1:3, 20mm thick for laying floor finishes.
33Material and labour for Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush.
34Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil soil.
35Earth work excavation in hard/ dense soil in trenches width and depth not exceeding 1.50m and getting out.
36Material and Labour for Hardcore of gauge n exc. 63 mm,using broken stone or boulder deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
37M & L for P.C.C 1:4:8, D2 type using 40mm graded aggregated in foundation.
38M&L for cement concrete in foundation ,filling and mass concrete typeB2 1:2:4 using 20mm aggregate
39Material and Labour for flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams,and similar work; vertical or to batter.
40M & L for R.C.C, M20, 20mm graded aggregate in Walls, retaining walls,basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresseswalls.
41Material and Labour for Formwork to flat faces of walls,retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses,etc.; vertical or to batter.
42Material and Labour for Providing precast slab for drains using type B1 1:2:4 (20mm graded aggregate) set in cement mortor 1:6.
43S&F of mild steel reinforcement deformed or twisted bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
44Material and labour for painting surfaces of any description, over 10cm in width or girth, on structural steel surfaces like purlin trusses, open gantry girders and stanchions etc., with two coat of aluminium paint over one coat of aluminimum red oxide primer including prepartation of new surfaces as specified and as directed .Protective measure (As per MES Part-I spec point 15.10.3) Surfaces of doors, windows, floors, articles of furniture, machineries etc., and such other parts of the building not to be treated shall be protected by using new taurpaulin sheets to avoid the paint drops , dust on the machines and shop floor from being splashed upon. Such surfaces shall be cleaned of splashes of white wash, colour wash, distemper, aluminium/synthetic enamel paint etc. The contractor shall be responsible for any damage to the fittings, fixture and furniture etc., The paint to be used shall be of ( Asian paints, Berger paints, Nerolac paints) or sutably equivalent. The brands shall be got approved by EIC
45Material and labour for painting surfaces of any description, over 10cm in width or girth, on structural steel surfaces like purlin trusses, open gantry girders and stanchions etc., with two coat of aluminium paint and one coat of aluminium red oxide including prepartation of old surfaces as specified and as directed.Protective measure (As per MES Part-I spec point 15.10.3) Surfaces of doors, windows, floors, articles of furniture, machineries etc., and such other parts of the building not to be treated shall be protected by using new taurpaulin sheets to avoid the paint drops , dust on the machines and shop floor from being splashed upon. Such surfaces shall be cleaned of splashes of white wash, colour wash, distemper, aluminium/synthetic enamel paint etc. The contractor shall be responsible for any damage to the fittings, fixture and furniture etc., The paint to be used shall be of (Asian paints, Berger paints, Nerolac paints) or sutably equivalent. The brands shall be got approved by EIC
46Material and labour for painting steel surfaces of any description over 10cm width or grith with two coats of synthetic enamel paint over a coat of red oxide primer including preparing new surfaces
47Material and labour for painting two coats of synthetic enamel paint on old steel surfaces including preparation of old surfaces.
48S&F of Pre-painted galvalume aluminium zinc coating GI based corrugatted steel sheet 0.50mm (TCT) thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self drilling / self tapping anti corrisive screws with EPDM seal complete all as per manfacturers specifications and instructions and as approved and as directed, by considering the dimensions & consideing the dimension & height including all necessary scaffolding and safety aspects complete.
49S &F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/screw cap as specified .
50Material and labour for Polycarbonite sheet 2mm thick to suit the existing roof profile as in roof covering/cladding to wall self drilling/self tapping anticorrisive serews with EPDM seal complete all as per manfacturers specification and instructions and as approved and as directed,by considering the dimension & including all necessary sceaffolding and safty aspects complete.
51Material and labour for applying two coat of exterior plastic emulsion over one coat of primer inculding preparation of New surfaces on external wall surfaces all complete (MAKE:- ASIAN Paint,NEROLAC, BERGER) or suitable equivalent make.
52Material and labour for applying two coats of internal emulsion paint with one coat primer on internal wall of painted new surfaces all complete including prepartion.
53Material and labour for applying two coats of internal emulsion paint with one coat primer on internal wall of painted new surfaces all complete for false ceiling .
54Material and labour for two coat of white washing on walls including preparartion of new surfaces.
55Felling of tree exc. 30 cm and not exceeding 100 cm girth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50 m and clearing site.
56Re-installation of machineries such as one crane which is moving on the mono rail at the height of 5m and two tank puller at 3m depth by carefully dismanling them from their position and hand over to GA shop.
57Supply and fixing of MS ERW Pipe 100 mm bore
58Supply and Fixing of Hydrant valve single headed
59Supply and Fixing of Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard.
60Supply and fixing of C P hose 15 m
61Material and labour for Point wiring with PVC insulated sheathed single core cable 1100V grade confirming to IS 694 multi strand copper conductor along with 2mm thick PVC conduuit accessories run on wall or roof including M.S. switch box concealed in the wall(made out of 3mm thick sheet) and laminated sun mica sheet 3mm thick cover for housing the switches, regulators and plug socket etc. mount on a wall/roof etc. including 16SWG bare copper earth continuity wire.(Make:Finolex/Havells/Polycab) or suitable equivalent make. a)one light point or one fan point controlled by one switch with cables1.5 sqmm size.
62Material and labour for Point wiring with PVC insulated sheathed single core cable 1100V grade confirming to IS 694 multi strand copper conductor along with 2mm thick PVC conduuit accessories run on wall or roof including M.S. switch box concealed in the wall(made out of 3mm thick sheet) and laminated sun mica sheet 3mm thick cover for housing the switches, regulators and plug socket etc. mount on a wall/roof etc. including 16SWG bare copper earth continuity wire.(Make:Finolex/Havells/Polycab) or suitable equivalent make. b)One 3 pin socket outlet 5 amps on the same board with other switches, with cables 2.5 sqmm size.
63Material and labour for Point wiring with PVC insulated sheathed single core cable 1100V grade confirming to IS 694 multi strand copper conductor along with 2mm thick PVC conduuit accessories run on wall or roof including M.S. switch box concealed in the wall(made out of 3mm thick sheet) and laminated sun mica sheet 3mm thick cover for housing the switches, regulators and plug socket etc. mount on a wall/roof etc. including 16SWG bare copper earth continuity wire.(Make:Finolex/Havells/Polycab) or suitable equivalent make. c)One 3 pin socket outlet 5 amps independent, with cables 2.5 sqmm size.
64Supply & fixing of switch piano, flush type single pole one way 6 amps.
65Supply & fixing of Socket outled 2 in 1 , 3 pin , 6 Amps.
66Supply & Fixing of wiring for circuit/sub main wiring along with earth wire & PVC conduit accessories with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required.(Make:Finolex/Havells/Polycab) or suitable equivalent make. a) 2x2.5sqmm + 1x2.5sqmm earth wire
67Supply & Fixing of wiring for circuit/sub main wiring along with earth wire & PVC conduit accessories with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required.(Make:Finolex/Havells/Polycab) or suitable equivalent make. b) 2x4.0sqmm + 1x4.0sqmm earth wire
68Supply & Fixing of wiring for circuit/sub main wiring along with earth wire & pvc conduit accessories with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required. (Make:Finolex /Havells /Polycab) or suitable equivalent make. a) 4x6.0sqmm + 1x6.0sqmm earth wire
69Supply & Fixing of wiring for circuit/sub main wiring along with earth wire & pvc conduit accessories with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required. (Make:Finolex /Havells /Polycab) or suitable equivalent make. a) 4x16.0sqmm + 1x16.0sqmm earth wire
70Material & Labour for ceiling rose, 3 Phase/ PVC polycorbonate, isolated body. (Make: Legrand/Anchor/Havells) or suitable equivalent make.
71Supply & fixing of switch socket combination 2 in 1, 6 A flush type .(Make: Legrand/Anchor/Havells) or suitable equivalent make.
72Supply & fixing of switch socket combination 3 pin 6A/16A, 5 in 1 flush type.(Make: Legrand/Anchor/Havells) or suitable equivalent make.
73Supply & Fixing of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required.(Make: Legrand/Anchor/Havells) or suitable equivalent make.
74Supply and fixing LED luminaire 600 mm x 600 mm 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.(Make: Philips/Bajaj/Havells) or suitable equivalent make.
75Supply and fixing of LED light fittings 1 x 20 watts 220 volt AC decorative box type with driver uni, holder including LED tubelight connecting up with three core flexible copper coductor cable of suitable size from ceiling rose complete.(Make: Philips/Bajaj/Havells) or suitable equivalent make.
76Material and labour for Brick walls cutting chases,pining in, making good to facing where required and pointing in cement mortor 1:3 to ends and cutting chases for concealed conduit wiring, etc., and making good,cutting exc. 10 cm but not exc. 20 cm grith.
77Taking down Aluminium point wiring(light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody and making good disturbed surfaces of wall, floors, etc.
78Supply & fixing of sheet metal enclosures for DBs when MCBs to be used Single pole & neutral ,240 v without busbar, 2 way single door.(Make: Legrand/Anchor/Havells) or suitable equivalent make.
79Supply & fixing of sheet metal enclosures for DBs when MCBs to be used Single pole & neutral,240 v, 200 amps rated busbar,8 way double door.
80Supply & fixing of sheet metal enclosures for DBs when MCBs to be used Triple pole & neutral with 200 amps rated bus bar, 415 v ,8 way double door. (Make: Legrand/Anchor/Havells)or suitable equivalent make.
81Supply & Fixing of MCCB 3pole, 415 V, fixed type 100Amps with breaking capacity 16KA,(Make: Legrand/Anchor/Havells/ABB/L&T) or suitable equivalent make.
82Supply and fixing amp rating 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 100 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning.(Make: Legrand/Anchor/Havells /ABB /L&T) or suitable equivalent make.
83Supply and fixing amp rating 240 V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning.(Make: Legrand/Anchor/Havells/ABB/L&T) or suitable equivalent make.
84Supply and fixing amp rating 240 V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning.
85Supply, fixing & connecting the single pole and neutral,240 V enclosure with two pin & earth plug & socket complete with one single pole 20 amps MCB . (Make: Legrand/Anchor/Havells/ABB/L&T) or suitable equivalent make.
86Hanging / fixing already removed ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan
87Supply, laying or fixing with suitable clamps or passing through pipe or laying in the trench , 1100 volts grade heavy duty cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional areaof 50 SQMM, 4 Core cable.
88Demolition of cement concrete of any description and in any position
89Material and labour for cement concrete 1:2:4 Type B1 using 20mm graded aggregate in foundations, filling and mass concrete.
90Supply & fixing of galvanised steel tubes, medium grade 20mm dia for ceiling fan down rod.
91Supply and fixing of LED flood light 120 watts 230 volt AC outdoor type with thermal management in multiple optics and equiped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp. (Make: Philips/Bajaj/Havells) or suitable equivalent make.
92Excavating in trenches hard/dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cable.
93Material & labour for sand filling for cushioning on U.G cable
94Materal & labour for Bricks; common burnt clay building bricks sub class B Old size designation 75 for protection to U.G cable
95Returning, refilling in the excavated trench after laying of power cable including spreading levelling, watering and well ramming in layers not exc 25 cm. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56726240
AUTHORITY Government Departments
TENDER VALUE 3.02 Crore
LAST DATE 13-08-2026
Authority
Authority Name Heavy Vehicles Factory
Work Description Tender for Special Repairs To Walls And Floors Of Qa(Ga) Labs, Provision Of Tank Parking Shed And Roof Covering For Northern Side Washing R In Ga Shop At New Facility, Hvf, Avadi.
Basic Detail
Tender No HVF/TE/13025/CEO/2026-27/45
Bidding Type Tender
Location
City Thiruvallur
State Tamil Nadu
Key Dates
Publish Date 29 Jul 2026
Submission Date 13 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 3.02 Crore
Tender Fee Ref. Documents
EMD 3.78 Lakhs
Exemption Not Available
Document List
62c58a98-1325-4a99-a2f9-9367b302e36f.html
BOQ_333577.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

62c58a98-1325-4a99-a2f9-9367b302e36f.html

xls

BOQ_333577.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender