Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56726189

Tender For Repair, Replacement Of Street, Security Lights At Otm Lalgarh Jattan Mil Stn Under Ge Lalgarh Jattan

Issued by Statutory Bodies & Commissions/Committees · Ganganagar, Rajasthan
Tender Value
40 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
16 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair, Replacement Of Street, Security Lights At Otm Lalgarh Jattan Mil Stn Under Ge Lalgarh Jattan

BOQ

Name of Work:- REPAIR, REPLACEMENT OF STREET, SECURITY LIGHTS AT OTM LALGARH JATTAN MIL STN UNDER GE LALGARH JATTAN
Sl. No. Item Description
1Materal and labour for attending day to day street / security light (of any type, wattage and make, installed at various locations of Lalgarh Jattan Mil Stn) complaints received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of drivers, Surge Protection Device (SPD), replacement of old unserviceable light fittings/fixtures, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment, and properly insulating the connections complete all as specified & directed by the Engineer-in-Charge. Note :-(i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under respective items of this BoQ .(ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 08 hours of receipt of complaints.(iii) contractors manpower shall attend complaint cell at 9.00 AM on dailly and shall get the complaint noted, address the complaints and completion report to given at the enf of the day to JE E/M. (iv) Vehicle, ladder, tools, LT tapes etc as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement.(v) Any complaint/job given on a particular day shall be repaired/rectified within eight hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day. (vi) Old retrieved material shall be deposited in AGE E/M yard.
2Supply only electric driver for 35/45 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
3Supply only electric driver for 60 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
4Supply only electric driver for 90/100 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
5Supply only electric driver for 150/200 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
6Supply only surge arrestor of 5KV/10KV for LED type fittings complete all as specified and directed by the Engineer-in-Charge.
7Supply & fixing in repairs Automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take three phase load of 8KW, Contactor Rating 25-32Amps, MCB SP 32Amps, complete all as specified and directed by the Engineer-in-Charge.
8Supply and fix in repair to Nature Switch smart sensor operational voltage range 120-440V , 50 Hz output load rating 5 Amps switching endurance more than 5000Cycles , Device power consumption less than 1Watt, IP rating 65 complete all as specified and directed by Engr in charge. Make :- L&T, Legrand, Havells, Schnieder , Kakatiya.
9Supply and fixing in repair 3 pole power contactor type ML 3 AC 3 rating(100A) Aux Contactors 2NO+2NC compatible with digital timer of suitable capacity complete all as specified and directed by EIC.Make :- L&T, Legrand, Havells, Schnieder
10Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as apecified and directed.
11Excavation in trenches exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as apecified and directed.
12Returning, filling including spreding, leveling watering & well ramming in laying not exc. 25cm for Soft/loose soil
13Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point for Soft / loose soil
14Supply and laying in replacement and testing of cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of following sizes,Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
1535 Sqmm 3.5 Core.
1625 Sqmm 4 Core
1716 Sqmm 2 Core
1810 Sqmm 2 Core
196 Sqmm 2 Core
20Supply and laying DWC pipe of size 50/38 mm including all necessary fittings for cable protection complete all as specified and directed by Engr-in-charge.
21Supply and laying DWC pipe of size 40/30 mm including all necessary fittings for cable protection complete all as specified and directed by Engr-in-charge.
22Supply and fix 1.5 Sqmm three core PVC insulated, unsheathed multistranded copper conductor cable 1100 volts grade complete all as specified and directed by Engr in Charge.
23M&L for in repairs earthing complete with Galvanized Iron electrode 60cmx60cmx3.15mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GIr strip of size 32x6mm by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dully all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of Soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed.Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
24Supply and fix in replacement rigid non metallic PVC Conduit 20 mm dia exclusive of boxes, junction boxes, terminal but inclusive of all Tees, Bends, Elbows, reducers, bell mouth, tube ends and fixing accessories such as couplers, lock nuts, saddles pipe hooks etc complete all as specified and directed by Engr-In-Charge.
25Material & Labour for preparation of old painted surface of steel tubular pole (9/11 meter long above coping) and applying two coat of aluminium paint, making of strip of 30 cm width (black and white in alternate band) upto 1500 mm height with one synthetic enamel paint , rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specifeid and directed.
26Material & Labour for preparation of old painted surface of LT PCC pole (up to top above coping), applying two coat cement base paint, making of strip of 30 cm width (black and white in alternate band) upto 1500 mm height with one synthetic enamel paint, rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat aluminum paint complete all as specified and directed
27Material and labour for writting of Pole Nos on existing pole with stencil with white colour in black colour background of 80 mm hight around the radius of pole and all as specified and directed by Engr in charge.
28Supply and fixing in replacement junction box, dust and water proof (IP65), out door type, made out of Polycarbonate with glass fiber re-inforced, size of box 200 x 160 x 98 mm with swinging cover and locking clamp, pole mounting, consisting 4 Nos mounted on SMC insulator links and provision of incoming/outgoing cables with gland, including in built 6Amp MCB, SP, 9/10KA one No complete all as specified and as directed by Engineer-in-charge. Note : Rate deemed to be inclusive of MS clamps and nut bolts for fixing the box along pole.
29Supply and fixing in replacement junction box, dust and water proof (IP65), out door type, made out of Polycarbonate with glass fiber re-inforced, size of box 150 x 100 x 60 mm with swinging cover and locking clamp, pole mounting, consisting 2 Nos mounted on SMC insulator links and provision of incoming/outgoing cables with gland, including in built 6Amp MCB, SP, 9/10KA one No complete all as specified and as directed by Engineer-in-charge. Note : Rate deemed to be inclusive of MS clamps and nut bolts for fixing the box along pole.
30Supply and fixing in replacement 240V, 10KA 'B' curve miniature circuit breaker (MCB) SP 32 Amp complete with connection testing and commissioning complete all as specified and directed by Engr-In-Charge
31Supply and Fixing in replacement LED bollard light of 9 watt rated power IP 65 complete all as specified and directed by Engr-In-Charge. Note :- Charges for required PCC work and fastners grouting are included in this item.
32Supply and errecting in repair Prestressed cement concrete poles 9 metres long of cross section (102mm x 152mm) at top and (102mm x 289mm) at bottom class- 10 complying with requirement of IS-1678 - 1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer black and white strips 30CM wide each (05 Nos) up to 1.5 Mtrs height from coping & numbering of poles complete all as specified and directed. (Note:- Excavation, earthwork and PCC shall be measured and paid separately under respective item of Sch.)
33M&L PCC (1:2:4) type B1 using 20mm graded stone aggregates as in foundation foundation of poles etc including weathering slightly roundded or chamfered angle and throating necessary form work finishing all exposed faces of concrete etc complete all as specified and directed. Note :( Volume of poles/struts embedded in concrete shall be deducted. )
34M&L PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation of electric poles/struts etc including necessary form work and fair finish to exposed surface without using complete all as specified and directed. Note : Volume of poles/struts embedded in concrete shall be deducted.
35M & L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in coping for electric poles or for stay assy etc. complete all as specified and as directed by Engr-in-Charge.
36Dismantling of existing LT pole any size/type from foundation in necessary earth work including dismentling of concrete MS clamps nuts, bolts, earth wire, overhead lines conductor, insulators, gaurding cradles and other accessories complete all as specified and directed.
37M&L in replacement for 40mm bore GI pipe light grade with all fittings and fixtures fixed to pole and laid to floor/ground for mechanical protection of cable strip all as specified and directed
38Supply and fixing in replacement 4 Sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, aluminium conductor cable, flat type, in service connections etc complete all as specified & directed by the Engineer-in-Charge.
39Supply and fixing in replacement 6 Sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, aluminium conductor cable, flat type, in service connections etc complete all as specified & directed by the Engineer-in-Charge.
40Supply and fixing in replacement 10 Sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, aluminium conductor cable, flat type, in service connections etc complete all as specified & directed by the Engineer-in-Charge.
41Supply and fix in repair LED street light fitting of 90 Watt IP-66 sealed optic luminaire with housing made of die cast aluminium with smooth finish powder coated for better environmental protection complete all as specified below:-(i) The fixture shall be designed so as to ave lumen maintenance of at least 70% at the end of 70000 hours.(ii) The luminaire should be operable with auto adjustable 120-240 volt supply using the same driver. Ambient temperature at LED should not be more that 70 degree centigrade. (iii) Power factor of the electronic driver should be at least 0.90 abd efficiency of the luminaire to be more than 85%.(iv) The fixuture should be vibration resistance, if the fixture is also to be used in vibration prone areas like flyovers/bridges.(v) Heat dissipation should be managed through a built in external heat sink. (vi) Colour rendering index of minimum 65 with color temprature of 4000K.
42Ditto as per item No 36.00 above but 60 watt complete all as specified and directed by EIC
43Ditto as per item No 36.00 above but 45 watt complete all as specified and directed by EIC
44Supply and fix in repair to 200 Watt LED flood light with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed by Engr-in-Charge. Note : Rates for T&P along with suitable nos of tradesmen to fix flood lights at high mast/Bldg/other suitable location as decided by Engr-In-Charge shall be deemed to be included in the quited rates by the contractor.
45Ditto all as per ser item no 39.00 as above but for 150 watt LED Flood light.
46Ditto all as per ser item no 39.00 as above but for 100 watt LED Flood light.
47S&F in replacement of energy efficiant LED invertor dimmable street light 60 watt having aluminium housing,maintainable ,clear toughned glass ,suitable high efficiant secondary lans ,LM80 Certified ,isolated electronic CC driver RTC enabled,IP66 and IK 05 protection .The security light should operated in following RTC time span of 6PM 90watt ,11PM 27watt,4AM 45 watt ,and 6 AM 0 watt charactorstic as directed by Eng in charge.
48Supply & fix in repair LED post top lanterns of 40 Watt rated power and rated CCT 3000k, IP65 aesthatically designed spun Al spigot for mounting LED Driver and spun aluminium canopy which is painted white inside Epoxy powder coated matt black finish after phosphochromate treatment, weather proof construction having robust design delivers to meet the landscaping needs, Luminaire type, Opaline diffuser suitable to be fixed over galvanised pole of diameter upto 50mm complete all as specified and directed by Engr-In-Charge.
49Supply & fix in repair LED post top lanterns of 9/10 Watt rated power and rated CCT 3000k, IP65 aesthatically designed spun Al spigot for mounting LED Driver and spun aluminium canopy which is painted white inside Epoxy powder coated matt black finish after phosphochromate treatment, weather proof construction having robust design delivers to meet the landscaping needs, Luminaire type, Opaline diffuser suitable to be fixed over galvanised pole of diameter upto 40/50mm complete all as specified and directed by Engr-In-Charge.
50Supply and erecting factory made 7 Mtr long hot dip galvanised octagonal pole with 130 mm dia including 1.5 Mtr single Arm HDG OD-48.3 at bottom and 70 mm dia at top A/F made up of 3mm thick HT sheet along with foundation type base plate of size 220X220X12 mm foundation bolt 4 nos of M20X750 high J type EN8 Grade with inbuilt junction box suitable for incoming 3 phase LT cable 16sqmm 4 core having 6A SP B class MCB fixed on bakelite sheet and stud type connector inside the pole, the pole shall be adequetly strengthened at the location of the door to compensate for the loss in section including excavation and RCC/PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufactures instructions including marking pole numbers in letters and figures of size radium tape not less than 10cm height with red colour enamel paint complete all as specified and as directed.
51Supply and fixing in replacement brackets made out of GI tubing light grade 40mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing on poles/walls alongwith MS clamp for street light fitting including before fixing applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56726189
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair, Replacement Of Street, Security Lights At Otm Lalgarh Jattan Mil Stn Under Ge Lalgarh Jattan
Basic Detail
Tender No 8937-18/GE/2026-27
Bidding Type Tender
Location
City Ganganagar
State Rajasthan
Key Dates
Publish Date 29 Jul 2026
Submission Date 17 Aug 2026
Open Date 19 Aug 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
BOQ_875562.xls
c9962c4e-f8b0-4af3-862e-aac2873fb549.html
Tendernotice_1.pdf
tender_merged.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_875562.xls

html

c9962c4e-f8b0-4af3-862e-aac2873fb549.html

pdf

Tendernotice_1.pdf

pdf

tender_merged.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders