Tender For Welcome Maintenance For Officers Married Accn And Omq Spe Area Of Camero Complex At Subroto Park
Tender Value
45 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
3 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Welcome Maintenance For Officers Married Accn And Omq Spe Area Of Camero Complex At Subroto Park
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. raking out joints ,hacking for key and scrubbing down with water upto 4 storeys building, and incl removal of debris or bldg raw materials out side from defence premises, complete all as specified and directed. |
| 2 | M&L for 15mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth w/o using extra cement upto 4 storeys building with water proofing compound complete all as specified and directed. |
| 3 | M&L for 10mm thick cement plaster in cement mortar 1:6 on brick surfaces on fair face of brick work and finished even and smooth w/o using extra cement complete all as specified and directe.d |
| 4 | M&L for 5mm thick cement plaster in cement mortar 1:3 on concrete or brick surface and finished even and smooth w/o using extra cement as in ceiling complete all as specified and directed. |
| 5 | M&L for Complete removal of existing treatment under (Weather Coat/ OBD/ Emulsion Paint/ White wash etc) by scrapping with mechanical wall sander on wall and ceiling surfaces (having mechanical vacum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7''/9'' to make the surface free from dust, loose paint, removal of nails etc and filling cracks/ holes and window/ door jams by putty & repairs in good shape by skilled labour upto 4th storey building, Complete all as specified and directed. |
| 6 | M&L for Preparation of new/old plaster surfaces to external wall/chajjas/soffits surfaces and applying two coats of super quality weather proof exterior emulsion paint over a coat of primer using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying paints should be able to spray in hard to reach areas and penetration of distemper on the surface upto 4th storey building complete all as specified and directed |
| 7 | M&L for applying 1mm thick of wall care putty on wall/ceiling surfaces, complete all as specified and directed. |
| 8 | M&L for Preparation of new/old plaster surfaces of internal wall surfaces and applying two coats of oil bound distemper over a coat of primer using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hardto reach areas and penetration of distemper on the surface upto 4th storey building complete all as specified and directed |
| 9 | M&L for Preparation of new/old plaster surfaces of internal ceiling surfaces and applying one coats of oil bound distemper over a coat of primer using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hardto reach areas and penetration of distemper on the surface upto 4th storey building complete all as specified and directed |
| 10 | M&L for Prepration of new/old surfaces of Wall/ceiling and applying two coats of white wash complete all as specified and directed. |
| 11 | M&L for Prepation of old wood surface and wood based materials of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint, complete all as specified and directed. |
| 12 | M&L for Preparation of old steel surfaces and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 13 | Dismantling brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles and incl M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. |
| 14 | S&F factory made SFRC manhole / drain cover (Grade M-25) heavy duty cover slab in rectangular shape of size as required, 80 mm thick incl MS sheet 2 mm thick and 80 mm wide all around the cover including demolition of old manhole cover slab and removal outside from defence primises complete all as spefcified and directed. |
| 15 | S&F mild steel framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes : framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 as complete all as specified and directed. |
| 16 | S&F for Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240. complete all as specified and directed. |
| 17 | M&L for Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red-oxide, Complete all as specified and directed. |
| 18 | M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, including Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. |
| 19 | Demolition of cement concrete unreinforced in sunken portion in any position not otherwise specifically provided for complete all as specified and directed. |
| 20 | M&L for 25 mm thick PCC 1:2:4, type B-0 (using 12.50 mm graded crushed stone aggregates) as in floor surfaces, complete all as specified and directed. |
| 21 | M&L for PCC 1:5:10 type E2 (using 40mm graded stone aggregate), filling in the sunken as cinder/foam concrete complete all as specified and directed. |
| 22 | Providing and making sunken treatment in sunken portion to maintain the slope towards the spout including applying the under mentioned course complete all as specified and directed:-(a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly. (b) 15 mm thick plastering over floor & vertical sides/surfaces up to finished floor level +100mm height in 1:4 mixed with liquid water profing compound @ 200 per 50 kg of cement troweled to even and smooth finish without using extra cement including rounding of corners and junctions slopping towards spout. (c) apply two coats of acrylic polymer modified elastomeric water proofing coating (mixture of liquid plymer component and a cementitous powder) as per manufacturers instruction to bottom and vertical sides up to finished floor level +100mm height , the thicknes of each layer shall be 1 mm. when the second lyaer is still, sticky, coarse sand spray shall be carrried for the vertical and bottom surface. (d) Filling the sunken portion with water for 72 hrs and carrying out the ponding test (Any leakage / seepage noticed shall be repaired) Note:- (i) This treatement shall be done by the approved authorized applicators (ii) WPC shall be paid and measured seperately under relavent item |
| 23 | Taking out of APP modified water proofing membrane and demolition of loose or undulate concrete surface complete on roof surface and surface properly cleaned by wire brush and incl debris/scraps removal out side from defence premises complete all as specified and as directed. |
| 24 | M&L for PCC 1:2:4 type B1 using 20mm graded aggregate mixed with water proofing compound as per manufacturer instructions laid 40mm avg thickness as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 25 | M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:-(a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface.(b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm.(c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc.(d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame.Note:- This treatement shall be done by the approved authorized applicators and guarantee of treatement shall be minimum 10 years complete all as specified and directed |
| 26 | M&L for 2 coat of aluminium paint incl preparation of newly or previously untreated surfaces of any description, over 10cm width or girth, not otherwise described complete all as specified and directed. Please Enable Macros to View BoQ information |
| 27 | M&L for 2 coat of aluminium paint incl preparation of newly or previously untreated surfaces of any description, over 10cm width or girth, not otherwise described complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender