Tender For maintenance of W/S (Two Year Cleaning Of Ugr/Oht, Painting And Renovation Work, repair of Fire Fighting, Motor Gauge Filling Of Pea-Gravel And providing and laying Interlocking Tiles In Network Sector-1 To 7) Noida
Tender Overview
Project Description
Tender for maintenance of W/S (Two Year Cleaning Of Ugr/Oht, Painting And Renovation Work, repair of Fire Fighting, Motor Gauge Filling Of Pea-Gravel And providing and laying Interlocking Tiles In Network Sector-1 To 7) Noida
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster i/c disposal of rubbish to the dumping ground within 50 m lead. |
| 3 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. |
| 5 | Providing Wall putty on New Surface with approved quality material of Berger/J.K./Birla or Similar make 2 coats. |
| 6 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 7 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 8 | Supply, Lowering & Showing the annular space between Tube Well bore and assembly with 2mm to 5mm thick Pea gravel. |
| 9 | R/o Fire FightingP/F 100 mm dia Sluice Valve shall generally conform to IS 14846 with latest amendment, with length over flanged as per PD of IS 14846 corresponding to BS EN-558 / ISO 5752 Basic series 3 in CI construction having metal seating (IS 318 Gr. LTB 2). With comple component & material of construction following below:-1 - Body / Door / Dome - Cast Iron IS 210 Gr. FC 2602 - Spindle - Non rising: Stainless Steel AISI 4103 - Body seat / Door face - Gun metal : IS 318 Gr. LTB 2 (rings to be press fitted and riveted: no screws allowed)4 - Rivets - Soft annealed brass5 - Spindle Nut - Gun metal : IS 318 Gr. LTB 26 - Stem Seal - Greased Hemp7 - Fasteners - Carbon steel8 - Flange Drilling - IS 1538 Table 4 & 69 - PN 1.010 - Accessories (400 mm and above) - Ball thrust bearings to be housed above the wet chamber ie. above the gland. Enclosed Spur Gear Box for ease of operation. Air Plug11 - Painting / Coating - Inside & Outside epoxy liquid coated; DFT minimum 250 micron, shade RAL 5005 / 5015 (BLUE)12 - Hydro-test-(Open Ended only) (Seat : 10/16 Kg/cm2; Body: 15 / 24 Kg/cm213 - Upto 600mm dia Mannual Operated & above 600mm Gear boxMake-Indian Valve Pvt. Ltd. (IVC) / Kirloskar Brothers Limited KIRLOSKAR) |
| 10 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within lead of 50 m. The contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavating only after getting permission of Engineer-in-Charge. All kinds of soil. Pipes, cables etc. not exceeding 80 mm dia. |
| 11 | P/L following size of Finolex makes PVC pipes 6 Kg/Cm2 with required PVC standard special confirming to IS codes with latest amendment and lowering the same trenches and laying true to alignment and gradient complete i/c the cost of cutting of pipes for making up to length and making joints i/c cost of socket, plstochem PV-85 pvc solvent cement complete. PVC pipe must be confirming to IS:4985-2000 with latest amendment. Make-Finolex Industries Ltd./Kisan/Superme Industries Ltd. (Rate As per Comparative Statement Per. Rm.) 110 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVC standard Specials |
| 12 | White washing with lime to give an even shade New work (three or more coats) |
| 13 | P/F M.S. specials such as Tee, Bend, Collars, Tapers, Gap pieces, including Flange Ends as required, Painting, Cutting, welding as per site requirement of MS pipe thickness etc complete in all respect as per direction of E/I. |
| 14 | Cleaning of U.G.R. i/c removal of algae, fungous, sand, scrubbing with wire brush narial rassi, sweeping the jharu to give a clear surface, washing of floor & walls inside the tank i/c washing of vertical walls & columns, spraying on the inside of tank walls and ceiling non-toxic, biodegradable anti-bacterial agent license from Food and Drugs Administration (FDA) and certified for tank cleaning as per OECD guideline 432 Dec'01 (Necessary certificate should be attached) |
| 15 | Cleaning of Over Head Tank 22.0 m. High staging i/c sweeping & serubbing of bottom & side surface & also cleaning & disposal of silt, sand by manual & also by chain pulley block arrangement complete with supporting & rassi arrangement i/c washing of wall surface with water pressure with jet pump, spraying on the inside of tank walls and ceiling non-toxic, biodegradabie anti bacterial agent lincese from Food and Drugs Administration (FDA) and certified by Govt. approved laboratory for non toxicity of anti bactirial for tank cleaning as per OECD guideline 432 Dec'01 (Necessary certificate should be allached) Cost for 1 Job for 1200 KL OHT |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 17 | Providing and laying at 60 mm thick level factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern and i/c 50 mm thick compacted bed of course sand, filling the joints with coarse sand etc. all complete as per direction of E/I. |
| 18 | Brick work with bricks of class designation 100 in super structure above plinth level up to floor five level in all shapes and size in cement mortar 1 : 4 (1 Cement : 4 C. Sand). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender