Tender For General-Experimental Shed For Casps-Kvasu ,Mannuthy-General Electrical Work-2-Electrical Installation Work
Tender Value
1.89 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
6 days left
EMD
4727
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Idukki → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General-Experimental Shed For Casps-Kvasu ,Mannuthy-General Electrical Work-2-Electrical Installation Work
BOQ
| Sl. No. | Item Description |
| 1 | Main distribution board |
| 2 | OD71404/2026-2027:Supply and fixing of powder-coated single-phase energy meter panel box fabricated from 1.2 mm thick CRCA sheet steel, minimum size 450 mm × 300 mm × 200 mm, wall-mounted type, suitable for accommodating one KSEB single-phase energy meter and one 40 A, 2-pole MCB in place of a conventional service cut-out fuse, complete with DIN rail, hinged front door, locking arrangement, transparent viewing window, bottom cable entry provision, gland plate, mounting hardware and anti-corrosion powder coating, complete as required. |
| 3 | 1.14.5:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 4 | 2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door |
| 5 | OD69164/2026-2027:Supply and installation of PWD-approved branded 63A Double Pole Manual Changeover Switch, MCB modular type, centre-off (I-0-II) operation, suitable for manual changeover between KSEB supply and DG set supply, DIN rail mounting, conforming to IS/IEC 60947-3, complete with all accessories and connections. |
| 6 | OD69168/2026-2027:Supplying and fixing of PWD-approved branded 40 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 7 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 8 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 9 | Lighting Circuit - Fittings and Wiring |
| 10 | OD69169/2026-2027:Supplying and fixing following size/ modules, surface type PVC/Polycarbonate gang box along with cover plate for modular switches in recess as required.12 Module (200mmX150mm) |
| 11 | OD69178/2026-2027:Supplying and fixing following size/ modules, surface type PVC/Polycarbonate gang box along with cover plate for modular switches in recess as required.6 Module (200mmX75mm) |
| 12 | OD69179/2026-2027:Supplying and installing the following size/modules: surface type PVC/Polycarbonate gang box, complete with a cover plate for modular switches in recess as required. 2 Module (75mm x 75mm). |
| 13 | OD70346/2026-2027:Supply, installation, testing and commissioning of 60 W incandescent lamp fitting complete with B22 bayonet cap holder, suitable for operation on 230 V, 50 Hz AC single-phase supply, including pendant type B22 lamp holder, base/accessories, necessary screws, connection to existing wiring and fixing on wall or ceiling as required. |
| 14 | OD70347/2026-2027:Supply, installation, testing and commissioning of PWD-approved branded 20 W, 4-feet LED Batten Fitting, complete with integrated LED driver, polycarbonate housing and diffuser, suitable for operation on 230 V, 50 Hz AC single-phase supply, having minimum efficacy of 100 lm/W, cool white (6500 K) light output, CRI > 80, including all mounting accessories, connection to existing wiring and fixing on wall/ceiling as required. |
| 15 | OD70380/2026-2027:Supply and laying of 1.5 sq.mm twin-core reinforced flexible pendant cable, consisting of two 1.5 sq.mm stranded annealed copper conductors with PVC insulation, cotton/nylon reinforcement and overall PVC sheathing, suitable for 1100 V grade and intended for pendant light fittings, portable appliances and suspended equipment, including dressing, fixing, termination and all incidental works as required. |
| 16 | OD71160/2026-2027:Wiring for light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch FRLS PVC insulated copper conductor single core cable etc as required. Group B |
| 17 | Power Circuit - Fittings & Wiring |
| 18 | 1.23.3:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch |
| 19 | 1.23.5:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet |
| 20 | OD70459/2026-2027:Supplying and installing the following size/modules: surface type PVC/Polycarbonate gang box, complete with a cover plate for modular switches in recess as required. 3 Module (100mm x 75mm). |
| 21 | OD70460/2026-2027:Supplying and fixing following size/ modules, surface type PVC/Polycarbonate gang box along with cover plate for modular switches in recess as required.6 Module (200mmX75mm) |
| 22 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 23 | Suspended Support System |
| 24 | OD71091/2026-2027:Supply, fabrication, installation, testing and commissioning of a complete pendant lighting support arrangement system for suspended mounting of 60 Nos. of 60 W incandescent lamp fittings inside the incubation room. The work shall include providing and fixing three (3) Nos. SS304 grade stainless steel horizontal support tubes of 25 mm outside diameter × 1.5 mm wall thickness, each approximately 18.30 m long (total tube length 55 m), installed longitudinally above the three rows of cubicles at a height of 2.0 m above finished floor level (FFL).The support tubes shall be suspended from the existing GI sheet roof structure using twenty-one (21) Nos. SS304 hanger clamp/U-bolt assemblies and twenty-one (21) sets of M8 threaded rod suspension assemblies with an average suspension length of 800 mm, complete with SS304 nuts, washers, locking nuts, all necessary fixing hardware, and UV-resistant Nylon 66 cable ties (7.6 mm × 370 mm) for securing 25 mm HD PVC conduit to the support tubes.The scope of work shall further include all necessary fabrication, cutting, drilling, alignment, erection, testing and commissioning, together with the supply of all labour, tools, tackles, consumables, accessories and incidental materials required for the complete installation of the pendant lighting support arrangement. The system shall ensure that each incandescent lamp is centrally suspended above its respective cubicle and electrically connected in parallel, complete in all respects and as directed by the Engineer-in-Charge. |
| 25 | OD71536/2026-2027:Supply, fabrication and erecting suspended support arrangement for six numbers of 20 W, 4 feet LED batten fittings in the incubation room using 25 mm × 25 mm × 2 mm G.I. square tube suspended from RCC ceiling by 6 mm G.I. threaded rods with anchor fasteners, complete with nuts, bolts, washers, clamps, PVC conduit, cable support arrangement and all accessories required for proper installation, including fixing of LED fittings and labour charges, complete as required at site. |
| 26 | Switchboard Support Arrangement |
| 27 | OD71517/2026-2027:Supply, fabrication and installation of one complete switchboard support assembly comprising one SS304 grade stainless steel round tube support pole of 25 mm outside diameter × 1.5 mm wall thickness and 1350 mm height above finished floor level, rigidly fixed to the floor using one SS304 base plate of size 100 mm × 100 mm × 5 mm and four Nos. M8 × 75 mm stainless steel anchor fasteners. The work shall also include providing and fixing one weather-resistant 6 mm thick Fibre Reinforced Plastic (FRP) sheet of size 450 mm × 700 mm, suitable for mounting two Nos. 12-module switchboards arranged vertically (one above the other), complete with drilling, edge finishing, PVC spacer bushes, stainless steel screws, nuts, washers and all necessary fixing accessories. The work shall further include providing UV-resistant nylon cable ties for securing adjacent PVC conduit to the support pole and all labour, tools, hardware and incidental works required for complete installation, as directed by the Engineer-in-Charge. |
| 28 | 25mm PVC Conduit |
| 29 | OD71115/2026-2027:Supplying and fixing of medium class 25 mm PVC conduit along with accessories in surface wiring as required |
| 30 | Earthing System |
| 31 | 5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 32 | OD71189/2026-2027:Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 33 | KSEB Connection Charges |
| 34 | OD105518/2026-2027:Providing liaison services for obtaining a new LT single-phase electrical service connection, including the preparation and submission of all required drawings, applications, and supporting documentation. All statutory fees, inspection charges, and installation charges shall be borne separately by the University. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender