Tender For Repair/Replacement Of Stp Pipe Lines, Valves And Other Connected Works At Af Stn Amritsar
Tender Value
7.99 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
6 days left
EMD
500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Amritsar → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Stp Pipe Lines, Valves And Other Connected Works At Af Stn Amritsar
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Aug-2026 | CORRIGENDUM NO 1 | Fee | 18-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for Cleaning of Coarse Bar screen chamber of size 500X1200X300 mm as described including removal of accumulated screenings, waste, slit and other deposited materials from the coarse bar screen chamber, manual cleaning of screen bars, collection, loading, transportation of waste out outside MoD land in a closed container as per State Pollution Control Board Norms ,washing of the chamber with clean water including all labour, tools as directed by Engr-in-charge |
| 2 | Material and labour for Cleaning of Fine Bar Screen chamber of size 500X1200X300 mm as described including removal of accumulated screenings, waste, slit and other deposited materials from the coarse bar screen chamber, manual cleaning of screen bars, collection, loading, transportation of waste outside MoD land in a closed container as per State Pollution Control Board Normswashing of the chamber with clean water including all labour, tools as directed by Engr-in-charge |
| 3 | Material and labour for Cleaning of settling chamber (Secondary clarifier) of size 1200 X 800 X 1000 mm as described including dewatering, removal of settled sludge, grit,slit and other deposit from the chamber,manual/mechanical cleaning of wall, floor,outlet, collection, loading, transportation and disposal of sludge outside MoD land in a closed container as per State Pollution Control Board Norms,washing of the chamber with clean water including all labour, tools as directed by Engr-in-charge |
| 4 | Material and labour for Cleaning and painting of Equalization tank of size 7100 X 7100 X 2500 mm as described including dewatering, removal of settled sludge, grit,slit and other deposit, cleaning of tank floor, wall, inlet and outlet channels, washing and drying of surface,surface prparation by wire scraping to remove rust, old paint and application of one coat of epoxy primer followed by two coats of chemical resistant epoxy paint on all internal RCC walls, floor, MS surfaces,ladders,pipe supports and other steel components,collection , loading, transportation and disposal of removed sludge outside MoD land in a closed container as per State Pollution Control Board Normsincluding all labour, tools as directed by Engr-in-charge |
| 5 | Material and labour for Cleaning and painting of MBBR tank of size 2500 X2500 X 5000 mm as described including isolation and dewatering of the tank, removal of MBBR media and storage, removal of settled sludge, biofilm deposits and settled solids, cleaning of tank floor, walls, aeration grid,screens,inlet and outlet arrangements,washing with clean water and refiling up with new fiter media in layers all as per maufactures/reommendations/exsiting including testing and commissioning etc. (Media will be paid seperately under particular schedule of BOQ), surface preparation of exposed MS structures by scrapping apllication of one coat of epoxy primer followed by two coats of chemical resistant epoxy paint on all all internal RCC walls, floor, MS surfaces,ladders,pipe supports and other steel components,collection , loading, transportation and disposal of removed sludge outside MoD land in a closed container as per State Pollution Control Board Norms, including all labour, tools as directed by Engr-in-charge |
| 6 | Material and labour for Cleaning of Tube Settler of size 5200X3000x2700 mm as described including isolation and dewatering of the tank, removal of tube settler modules,cleaning of tube media, inlet and outlet channels, sludge collection, refixing of tube settler modules, loading, transportation and disposal of removed sludge outside MoD land in a closed container as per State Pollution Control Board Norms including all labour, tools as directed by Engr-in-charge |
| 7 | Material and labour for Cleaning and painting of Chlorine Contact tank of size 5200X1700X1000 mm as described including isolation and dewatering of the tank, removal of MBBR media and storage, removal of settled sludge, biofilm deposits and settled solids, cleaning of tank floor, walls, aeration grid,screens,inlet and outlet arrangements,washing with clean water and reinstallation of MBBR media with new (paid seperately under particular schedule of BOQ), surface preparation of exposed MS structures by scrapping apllication of one coat of epoxy primer followed by two coats of chemical resistant epoxy paint on all all internal RCC walls, floor, MS surfaces,ladders,pipe supports and other steel components,collection , loading, transportation and disposal of removed sludge outside MoD land in a closed container as per State Pollution Control Board Norms including all labour, tools as directed by Engr-in-charge |
| 8 | Material and labour for Cleaning and painting of Chlorine Dosing tank of size 5200X1700X1000 mm as described including isolation and dewatering of the tank, removal of MBBR media and storage, removal of settled sludge, biofilm deposits and settled solids, cleaning of tank floor, walls, aeration grid,screens,inlet and outlet arrangements,washing with clean water and reinstallation of MBBR media with new (paid seperately under particular schedule of BOQ), surface preparation of exposed MS structures by scrapping apllication of one coat of epoxy primer followed by two coats of chemical resistant epoxy paint on all all internal RCC walls, floor, MS surfaces,ladders,pipe supports and other steel components,collection , loading, transportation and disposal of removed sludge outside MoD land in a closed container as per State Pollution Control Board Norms including all labour, tools as directed by Engr-in-charge |
| 9 | M & L for cleaning raw sewage sump collection chamber from sludge drying beds of size 4800X 4800 X 1200 mm (04 Nos) and sludge holding tank of size 3400 X 3400 X 2000 mm (01 Nos) from ground level in RCC construction. including removal of dry sludges,weeds and debris,cleaning of drainage channels and outlet pipes ,Removing and depositing of slit and sludge depositing away outside MoD land in a closed container as per State Pollution Control Board Norms , the tank cleaning entire internal surface of tank with bleaching powder and flushing with water all as specified and marking dt of cleaning with enamelled paints as directed NOTE(a) The rate deemed to be inclusive of T&P and transportation required for disposal of sludge/dirt away from the site. (b) The cleaning of tank shall be performed as directed by Engr-in-Charge |
| 10 | Supply, installation, test and commissioning LT distribution panel (CPRI approved) cubical type IP of powder coated factory made panel board, outdoor type double door , front and rear openable with separate sections for incoming, busbars and outgoing confirming to IP 65 protection, CPRI approved of suitable size made of Robust steel construction made from 3.15 mm thick CRCA mild duly powder coated by 7 tank process steel sheet with conter sunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry,formed gasket around doors, with provision of lock insert,earthing strips, wiring plan sockets,door stayfan and filter units,heaters and grouted in ground by using angle iron frame of size 50 mmX 50mm X 6mm ,PCC(1:2:4) type B-1 with 20 mm graded stone aggregate. the panel will be prewired with suitable size PVC insulated copper conductor cable ,aluminium bus bar of suitable rating ,4 pole duly colour coded housed with the following accessories :- Incoming : (i) MCCB 4 pole 200 A 36 KA alongwith spreader terminals with adjustable thermal and magnetic setting -01 Nos (Ics = 100 % Icu)Out going : (i) Star Delta Starter fully automatic suitable for 415V AC, suitable for 15/20 hp non clog submersible pump with incoming of 40 Amp MCB, 4 pole, 10 KA breaking capacity -02 Nos, power contactors of rating minimum 32Amp, AC3 duty and protection with 22-32A thermal overload relay, Three phase preventer, phase reversal protection -3Nos, (ii) Digital Voltmeter 0-500 V with selector switch -01 Nos (iii) Digital ampere meter 0-100 A with CT of suitable ration-01 No (iv) Phase indicator lamp RYB with sheds LED type 01 Set of three Note : The panel shall be minimum 0.5 metre above ground level fixed on MS angle of min size 40mmx40mmx5mm. The drawing of the panel shall be got approved from the Engineer Charge before manufactruing complete all as specified and directed by the Engineer in Charge. |
| 11 | Material & Labour for Repair and Rewinding of Non clogging Electric induction motor of capacity 12.5 HP to not exceeding 20 HP including disconnecting electrical connection carefully and shifting to workshop and opening the electric motor rotar & stator and Rewinding the motor as per existing gauge of copper winding wire, varnish, insulation sleve and reassembling the motor shift at site and connecting, testing on load ; complete all as specified and directed by Engineer-in-Charge.Note (i) The unit rate shall include for minor spares such as bolts, nuts wahers, oil seal , gasket, greasing etc as required. |
| 12 | Material & Labour for Repair of Non clogging Electric induction motor pump of capacity 12.5 HP to not exceeding 20 HP including disconnecting electrical connection carefully and shifting to workshop and dismantling of pump, shaft impeller unit etc as per existing , varnish, insulation sleve and reassembling the pump at site and connecting, testing on load ; complete all as specified and directed by Engineer-in-Charge.Note (i) The unit rate shall include for minor spares such as bolts, nuts wahers, oil seal , gasket, greasing etc as required. |
| 13 | Material & Labour for repair to pump shaft of Non clogging Electric induction motor pump capacity 12.5 HP to not exceeding 20 HP by filling of suitable material & by welding and turning of pump shaft for motor complete all as specified and directed by the Engineer in Charge. |
| 14 | Construction of brick masonary valve pit in replacement of size 100X100X100 CM ( internal size) type A for sluice valave complete all as specified including MS cover 3 mm thick including locaking arrangement and 40x40x6 mm angle iron frame duly painted with two coats of sythetic enamel paint over a coat of red oxide primer including necessary earthwork , material and labour complete |
| 15 | Supply and fixing in repair of Cast iron non return valve/Reflux valve 100 mm dia ISI marked both ends flanged and drilled with rubber joints, nuts, bolts and washer complete including taking out existing non return valve all as specified and directed by Engineer in Charge. |
| 16 | Supply, installation, fixing, jointing and testing in replacement of unserviceable cast iron sluice valve of dia 150 mm ,class PN-1.6 both ends flanged with iron wheel head and brass spindle, short body type, conforming to IS-14846 of 2000 including rubber gasket and nut blot with washer for flange joints complete, all as specified and directed by Engr-in-charge |
| 17 | Repairs and overhauling of sludge pumps 1 HP complete by opeing the stator rotor and rewinding, pump impellar ,bearings, shaft etc and making the pump serviceable complete in all respect ( Note- The rate quoted shall be inclusive of bearing, rewinding, overhauling, cleaning and painting of pump set etc comeplete all as specified and directed |
| 18 | Supply and filling MBBR biofilm carrier media made up of virgin HDPE, size 10mm dia K1 type specific complete of complete in layers as perexisting complete all as specified and as directed MAKE : MM AQUA or Equilant. |
| 19 | Dismantling, servicing, cleaning, lubrication, reassembly, alignment, tightening, checking of bearings, belts, motor and electrical connections, testing and trial run of Air Compressor Blower of capacity 300 Cum/hr complete as per direction of Engineer-in-Charge.Note: Any spare parts, consumables, lubricants, belts, bearings, or other materials required/replaced during servicing shall be paid separately under the respective BOQ item. |
| 20 | Supply and fixing inrepair of the following spare parts for twin lobe air cooled compressor blower Capacity of 300 cum / hrs complete all as directed by Engr-in-Charge :-(a) Piston Ring (8 Nos each set) |
| 21 | (b) Ball bearing |
| 22 | (c) Pressing bush |
| 23 | (d) Lock nut |
| 24 | (e) Distance ring |
| 25 | (f) 'O' ring |
| 26 | (g) Oil seal |
| 27 | (h) Locking washer |
| 28 | (j) Gear assembly |
| 29 | (l) Gasket A & B for casing/outer cover |
| 30 | (n) Oil level sight glass |
| 31 | (o) V Belt Guard |
| 32 | (p) V belt for air blower |
| 33 | (q) Flexible Connector (Inlet and outlet) |
| 34 | Disconnection and taking out of UNSV Butterfly valve and supply and fixing new Butterfly valve cast iron (ISI Marked) of the following sizes:-(a) 100mm dia |
| 35 | Supply & filling ISO VG 220 or ISO VG 320 gear oilil for lubrication of air cooled compressor complete all as directed by Engr-in-charge |
| 36 | M&L for carrying out chemical analysis BOD,COD,TSS.pH & O&G,NO2, HCL,FC test and all other parameter of treated sewer water of STP from Govt authorised laboratory all as per CPCB Norms complete all as directed by Engineer-in charge.Note :- The rate quoted is deemed to be inclusive of testing and collection of water samples in sealed PVC container at STPs and test has to be carried on monthly basis and test report to be submitted to Engr-in-charge in original |
| 37 | Material and Labour for Cleaning of E/M Installations yard ( STP) by cutting bushes,shrubs/cleaning grass and other wild growth trees with grass cutting machine including all necessary T&P and accessories,petrol, diesel upto satisfaction level all as directed by Engineer in charge |
| 38 | M&L for removing all paint by removers or burssing off by blow lamp and cleaning with scrappers any number of coats any width or grith/description and painting with two coats of synthetic enemelled paint over a coat of red oxide primer as per colour including writing pump No. and capcity of the pump with white paint all as direted by Engr-In- Charge for the following capacity of plant installed :- |
| 39 | (a) Three phase induction motor of any capacity |
| 40 | (b) Air compressor including motor |
| 41 | (c) Piping control valves for STP |
| 42 | (d) Suction delivery pipe line upto 150 mm dia |
| 43 | S&F in repairs pressure gauge (0-10 Kg/Cm²)4 inch dial including necessary specials and provision of suitable ferrule etc., complete all as specified and directed. Makes:- Gluck/Guru/Fe Big |
| 44 | Supply and apply a non- selective systemic herbicide (e.g. round off or equivalent containing Glyphosate) for purpose of grass and weed eradication .the herbicide must be applied according to the manufacturer instruction local environmental regulations, and in suitable weather condition to ensure effectiveness and safety .all neccessory precaution shall be taken to avoid damage to nearbr desirable vegetation or contamination of soil and water sources. Location;-STP |
| 45 | M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron strip 25X4mm as earth lead by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 40 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering all as specified and directed by Engr-in-Charge. Including taking out old u/s earthing. |
| 46 | Material and labour, rectification of leakage in CI/DI pipe line size 100 to 150 mm dia bore including filling of lead/fittings as required cocking to the existing joint including necesscary lead joint and spunyarn making the line serviceable and functioning complete all as specified and directed Note : The rate shall be deemed to be include excavation and earth work, returning, filling and removal of soil as required. Please Enable Macros to View BoQ information |
| 47 | Material and labour, rectification of leakage in CI/DI pipe line size 100 to 150 mm dia bore including filling of lead/fittings as required cocking to the existing joint including necesscary lead joint and spunyarn making the line serviceable and functioning complete all as specified and directed Note : The rate shall be deemed to be include excavation and earth work, returning, filling and removal of soil as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 01, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Aug 18, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysAug 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender