Tender For Supply, Installation, Testing And Commissioning Of Passenger Lift For Sant Tukaram Maharaj Natyagruh, Chhatrapati Sambhajinagar
Tender Value
24.21 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
4 days left
EMD
24212
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Aurangabad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing And Commissioning Of Passenger Lift For Sant Tukaram Maharaj Natyagruh, Chhatrapati Sambhajinagar
BOQ
| Sl. No. | Item Description |
| 1 | Passenger Lift Works |
| 2 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. DSR NO. 1-6-1 |
| 3 | Point wiring for light/fan/bell in 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification no. WG-PW/SW DSR NO. 1-7-3 |
| 4 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 4 ways (4 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB DSR NO. 5-4-8 |
| 5 | Supplying and erecting modular type two way switch 6A/10A (2 module) on provided plate and box with wiring connections complete. DSR NO. 1-6-5 |
| 6 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. DSR NO.1-6-2 |
| 7 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. DSR NO.1-6-11 |
| 8 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. DSR NO.1-6-29 |
| 9 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. DSR NO. 2-1-15 |
| 10 | Supplying and erecting CRCA powder coated mirror light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs at L70B50, IP 20 rated including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. DSR NO.2-1-17 |
| 11 | Supplying, erecting and marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB DSR NO.5-3-7 |
| 12 | Supplying, erecting and marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB DSR NO. 5-3-13 |
| 13 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB DSR NO. 5-4-9 |
| 14 | Supplying, erecting, testing & commisioning metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and painted with one coat of red lead paint and 2 coats of enamel paint or powder coating complete as per specification no. CP/SH/CR DSR NO.6-1-1 |
| 15 | Supplying, fixing, and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO DSR NO.5-6-9 |
| 16 | Supplying, fixing, and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO DSR NO. 5-6-13 |
| 17 | Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU DSR NO. 7-2-9 |
| 18 | Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU DSR NO. 7-2-33 |
| 19 | Supplying, installing & testing maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI DSR NO. 9-1-5 |
| 20 | Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. DSR NO. 9-2-4 |
| 21 | ( DSR NO. 17-1-7) SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with · Rated capacity :- 15 Passenger/1020Kg· Floors :- G+2 floor (3Stops/3 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL [applicable for PassengerLift with MRL only & Stretcher/Hospital Lift with MR & MRL]· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 800/900/1000 mm wide x2000mm high· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of ......mm wide x ......mmdeep, ......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304grade solid(non-claded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shallhave minimum 1 hour fire rating (with submission of necessary valid Test Certificate issued by NABL accredited or Independent Test laboratory)· Lift car enclosure made from SS 304 grade solid(non-claded) sheet of1.5mm, thick with hairline finish with frame made from MS girders,bracing of adequate size with minimum safety factor of 5, with ToeGuard Apron, with necessary false ceiling with LED lights having lightintensity of at least 100 lux in car, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer incharge. · COP with SS face plate having metallic push buttons with BrailleCode & luminous indicator around button with FPI, scrolling UP/DNLED indicator & with / without attendant key switch, OWD with audiovisualalarm, VAS in Marathi, Hindi & English with intercom system withtelephone instrument in Lift car, LMR & FCC/ground floor· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic pushbuttons with Braille Code & luminous indicator around button with CPI,Lift car arrival & next travel direction audio-visual indication at alllandings Lift controller based on microprocessor/ PLC with VVVF Drivehaving closed loop control system, with IBMS compatible having DSR NO. 17.1.7necessary port, The Controller shall have necessary Protections such asovercurrent, overvoltage, over speed, overheat for all devices includinglift motor and travel direction protection, protection for phase loss atinput or output, Ascending Car Overspeed Protection etc. variousoperation modes such as maintenance, change direction by attendant, fullload bypass, VIP call operation, self leveling operation, call cancel facility,auto return to home landing, fireman evacuation operation, dooropen/close operation from COP etc. The system can record informationfor minimum 30 latest faults, with Real-time clock management andHandheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength, copper wirefor power & control circuit, with provision for addition of floor/controlcard & allied accessories control panel having enclosure of 1.5mm CRCAsheet with powder coating with IP54 Protection class· ARD complete with necessary SMF VRLA batteries shall be suchthat minimum three consecutive rescue operations can be performedwithout recharging for the maximum travel distance between twoconsecutive served stops. ARD have a suitable audio alarm with visualindication or voice annunciation in the lift car or lift controller to indicate“Low battery”.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2nos minimum 2.0MP FHDIP based vandal proof Dome camera in lift car & in LMR/inside liftshaft top aimed on Lift machinery & controller with NVR kept inLMR/FCC with HDR data backup for 90 days with 20” FHD TVmonitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assemblymounted on adequate size girders duly fixed on LMR floor/ shaft wallscomplete with main/diverter traction sheaves, suspension wireropes/belts of adequate size & strength· Other mechanical parts such as 'T' section adequate size guide railsfor car & counter weight with brackets fasteners, counter weight framewith necessary blocks, buffers with necessary support arrangement, MSpit ladder etc. erected with necessary steel work· Minor civil work such as alteration work if any necessary for erectionof landing door frames and it's accessories e.g. sill, header, hole pass etccomplete with plaster finish, civil work for erection buffers, erection oflift machinery, adequate size core cuts if required & scaffolding forerecting guide rails, providing and fixing steel girders/RCC work havingadequate strength for mounting and hoisting lift machine etc. complete asper specification no. LFT.· General: - Job includes entire procedure of obtaining all necessaryerection permissions & \\"License to Work the Lift\\" from ElectricalInspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year fromthe date of commissioning |
| 22 | For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. (Add on A-3) |
| 23 | For Full Collective control system, add as below.For Lift travelling above First floor & up to Sixth floor (Add on B-1) |
| 24 | Dismantling the existing 13 to 17 Passenger / Stretcher / Goods lift of all types travelling G+1 floors ( 2 Landings / 2Stops) having withauto/manual operated doors for lift car & all landings with door frames, guide rails, controller, wiring buffers, Lift Machine, ropes complete with all allied accessories of Lift and making the site clear in all respect complete with refilling the holes with cement mortar & making the site as original this job includes transportation of the dismantled material upto division/section store and handing over to the section engineer/store keeper in charge complete DSR NO. 17-2-3 |
| 25 | For 13 to 17 passenger/stretcher/goods lift of all types (Add on A-3) |
| 26 | Civil work including wall plastering, granite frame (9 x 6 inch) electric supply from meter to machine room supply buffer, duct white wash, final touch up /refilling of holes duct , water proofing etc complete. (Ref : E-office comp No.1923644) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender