Tender For Provision Of Charging Station Of 240Kw And Shifting Of Oh Ht Line To Ug With Allied Works At Ge (Af) Chandigarh.
Tender Overview
Project Description
Tender For Provision Of Charging Station Of 240Kw And Shifting Of Oh Ht Line To Ug With Allied Works At Ge (Af) Chandigarh.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-Aug-2026 |
| 2 | 07-Aug-2026 | BOQ Corrigendum | BOQ | 18-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Suppy, installing, connecting, commissioning and testing of energy effficient transformer (level 3 of IS 1180 as per latest amendments of 2014) of capacity 400 KVA outddoor type, mounted on four pole structure, step down 11/0.433 KV, core type oil immersed, copper wound, natural oil cooled with external cooling tubes/radiators, having 3 phase 50 Hz AC supply, DYn-11 design, off load tap changer on HT side to vary secondary voltage ±7.5% in steps of 2.5% as per IS 1180 (Pt-I to III) with all standerd accessories including bushing on HT side, cable box on LT side, including first filling of new transformer oil (of di-electric strength not less than 60 KV) upto required level in conservator tank , complete all as specified and directed by Engineer-in-Charge. with and including the following :-(a) One No 100 mm dia, dial type thermometer with resetting device vapour pressure type having range 0 to 120 degree centigrade.(b) Rating plate and terminal marking plate.(c) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing.(d) Oil level gauge with max & min level marking.(e) Oil filter valve.(f) Oil drain valve. |
| 2 | (g) Lifting hooks.(h) Oil conservator with filling hole and cap.(j) Air relief valve plug.(l) Earth bushing for neutral outside the LT cable box for providing independent earthing for neutral.(m) Clear view type silica gel breather with first fill of fresh bluish color silica gel.Note :-[1] The transformer should be as per level 3 of IS 1180(2014) and energy conservation (Energy conservation Binary Corps) for which necessasry test certificate to be produced by contractor from manufacturer of the transformer. [2] Four pole structure and related items shall be measured and paid separately under respective items.[3] Pre dispatch inspection of transformer shall be carried out by the Rep of Accepting officer. All factory inspeection arrangments will be co-ordinated by the contractor.[4] Transformer shall be tested and commissioned by SEI after installing at site.All the T&P,testing equipments required for the same shall be arranged by the contractor and unit rate quoted will be deemed to included the cost of the same. |
| 3 | HT electric power cable crossed linked polyethylene XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, (heavy duty) with aluminium conductor, 11000 volts Earthed, grade of size 95 sqmm cross sectional area, 3.0 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing , complete all as specified and directed by Engineer-in- Charge. Note: Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items. |
| 4 | HT electric power cable crossed linked polyethylene XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, (heavy duty) with aluminium conductor, 11000 volts Earthed, grade of size 120 sqmm cross sectional area, 3.0 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing , complete all as specified and directed by Engineer-in- Charge. Note: Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items. |
| 5 | LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 120 sqmm cross sectional area, 3.5 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing , complete all as specified and directed by Engineer-in- Charge. Note: Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items. |
| 6 | Outdoor end termination joint kit (heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor, 3 core, 95 Sqmm size cable in and including jointing & testing ,complete all as specified and as directed by Engineer in charge. |
| 7 | Outdoor end termination joint kit (heat shrinkable) complete with jointing material and accessories suitable for 3 wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor, 3 core, 120 Sqmm size cable in and including jointing & testing ,complete all as specified and as directed by Engineer in charge. |
| 8 | Indoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3 wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor, 3 core, 95 Sqmm size cable in and including jointing & testing ,complete all as specified and as directed by Engineer in charge. Please Enable Macros to View BoQ information |
| 9 | Indoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3 wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor, 3 core, 95 Sqmm size cable in and including jointing & testing ,complete all as specified and as directed by Engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender