Tender For Provision Of 04 Esh Shed At Fad Bharatpur Mil Stn
Tender Value
10.13 Crore
Estimated cost
Bid Submission
04 Sep 2026
10 days left
EMD
8.31 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provision Of 04 Esh Shed At Fad Bharatpur Mil Stn
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Aug-2026 | Corrigendum No. 01 | Date | 04-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Lump sum price worked out by the contractor for \\"BUILDING WORKS\\" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 2 | Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 3 | Lump sum price worked out by the contractor for \\"ROAD, PATH AND CULVERT\\" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 4 | Lump sum price worked out by the contractor for \\"AREA DRAINAGE \\" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 5 | Lump sum price worked out by the contractor for \\"FENCING LENGTH AND GATE \\" as listed in Schedule ‘A’ Part-V\\" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 6 | Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY \\" as listed in Schedule ‘A’ Part-VI\\" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 7 | Lump sum price worked out by the contractor for \\"EXTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 8 | Lump sum price worked out by the contractor for \\" LIGHTENING PROTECTION \\" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 9 | Lump sum price worked out by the contractor for \\"SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK\\" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 10 | Sch 'A' Part-X MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XV (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule). |
| 11 | INTERNAL ELECTRIFICATION Supply and fixing flameproof LED light fixture/ fitting CIMFRM certified 50W Sunflower LED complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size of Cat Part No PEC/LED/2003 of Pluto Flame proof Controls or equivalent as approved by GE complete all as specified and directed. |
| 12 | Supply and fixing LED flameproof tube light fitting CIMFRM certified 1x20W LED tube light fixture complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size as approved by GE complete all as specified and directed. |
| 13 | Supply and fixing t of LED flameproof tube light fitting CMRI certified 2x20W LED tube light fixture complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size as approved by GE complete all as specified and directed. |
| 14 | Supply and fix flame proof and weather proof industrial type 4 way TPN DBs with various combination of incoming and outgoing MCB suitable for and including (a) 01 No MCB TPN 60 Amps, C type (incoming) (b) 08 Nos MCB SP 6-32 Amps C type (c) 1 Nos MCB SPN 40-63 Amps C type including necessary connection complete all as specified and directed. |
| 15 | Supply and fix flame proof and weather proof industrial type 8 Way SPN DBs with various combination of incoming and outgoing MCB suitable for and including (a) 01 No MCB SPN 32 Amps, C type (incoming) (b) 06 Nos MCB SP 6-32 Amps C type including necessary connection complete all as specified and directed. |
| 16 | Supply and fix flame proof and weather proof industrial type 3 way Junction Box 100mm dia as approved by GE including necessary connection complete all as specified and directed. |
| 17 | EXTERNAL WATER SUPPLYBoring/Drilling Trial bore holes of 200 diameter bore in all kinds of soils, unconsolidated & semi-consolidated formations and rocks by using suitable method (by DTH-cum-rotary or riverse rig method or auguring by hammering) or any other suitable drilling method upto 200 mtr depth below ground level in any type of soil rock/ hard rock / loose boulders with sand including collection of strata samples in transperent polybegs @2m or whenever there is any change in strata, selection of site for boring by standard method/ practice disposal of materials obtained ( soil, rock, boulders, etc) from boring to distance not exceeding 50 meter including complete in all respects with all labour, materials, tools and tackles, equipments, rig, etc. all as specified in IS 2800 and direction of the Engr in charge'.Note: If there is no water output after boring of trial bore, the contractor shall be carried out another boring at the place all as directed by Engr-in-charge. |
| 18 | Devolopment of borewell by Reaming of borewell from 200mm to 300mm drilling by direct rotary fast rig method or any approved method at site below ground level in any kind of soil strata incl hard stone/boulder complete all as specified in IS 2800 and directed. |
| 19 | Development of bore wells indulding flushingout tree roots, silt, fine sand by air compressor of suitable capacity not less than 450 CFM at 150 PSI & over pumping (25% extra capacity pump) 12 hours continuously to make water free from trublidity till clear water is obtained from bore well complete all as specified and directed. |
| 20 | Yield test of borewell after completion of development of bore well by V notch method or any method of compresser or by pumping as required complete all as per IS and as directed.Note: Necesssary equipment such as collection V notch water collection Tank, temporary motor pump set of capacity 1x 10 HP , temp HDPE column pipe,etc for testing for yield test shall be arranged by the contractor. |
| 21 | Supplying and lowering in the bore hole, the plain assembly MS casing pipe Fe 410 and Fe 450 grade steel as per IS-4270 and nominal bore of pipe 200mm and wall thickness of 5.4 mm including welding of pipe at site with two coats of approved anti-corrosive paint on outer faces of the pipe and specials including supply of all labour, equipments and materials complete as per specifications and instructions of complete all as specified and directed. |
| 22 | Supplying and lowering in the bore hole 200 mm, 5.4mm thick MS casing slotted pipe with all necessary fittings and painting of pipe with two coats of anti corrosive approved paint on outside surface of pipe before lowering including supplying all labour, equipments and materials complete as per IS, specifications and instructions of complete all as specified and directed. |
| 23 | Supply fixing and lowering MS bail plug and well cap suitable for 200 mm bore plain pipe thickness 5.4 mm complete with welding and painting of pipes all as specified and directed |
| 24 | Supply and erection of housing clamp fabricated out of MS flat iron bent to shape 50 mm x 8 mm thick including nuts, bolts and washers as per IS-2800 complete all as specified and directed. |
| 25 | Supply of pea gravel size ranging from 12mm to 8 mm. All gravel shall consist of hard well rounded particles reasonably uniform with uniformity coefficient of less than 2 including packing in the annular space between casing pipe & drilled bore as per the direction of ENGR-IN-CHARGE.& as specified, complete. |
| 26 | Supply, erection, testing and commissioning of Submersible pump and motor as per IS-9283 (latest) for a pumping capacity 10 HP with180mtr head & discharge capacity of 180 LPM suitable for 50mm dia delivery column pipe complete all as specified and directed. |
| 27 | S&F submersible cable weather proof with multi-stranded copper conductor 3 core of size 10 sqmm 1100 volts grade heavy duty including all accessories for connection pump from panel board, testing and commissioning complete all as specified and as directed. |
| 28 | Supply installation testing and commissioning of LT panel board outdoor cubical type IP55 protection, vermin and dust proof factory made of CRCA sheet 3.15mm thick back door detachable type fixed with nuts and bolts and front door fixed with hinges and knobs, powder coated for 3 Phase 415 volts, 50 Hz, AC supply complete all as specified and directed by Engr in Charge and comprising of the following:-a)Aluminium Strip Bus bar fixed on epoxy insulators capacity 100 Amp and bakelite insulation sheet at the back with coloured tape - 01 Set(3 phases and one neutral)b) Incoming MCB TPN 63 Amp10KA capacity - 01 No.c)Outgoing MCB TP 40 Amp10 KA capacity - 02 No.d) Electronic Digital type Ammeter flush type 0-100Amp with selector switch and CTs. - 01 No.e) Electronic Digital type Voltmeter flush type 0-500V with Selector Switch - 01No.f) Set of indicator lamp RYB - 01 Setg) FASD Motor Starter with MPCB and single phase prevention suitable for 10 HP pump - 01 No.h) Complete internal wiring with suitable size copper conductor including cable lugs,glands etc.j) Masonary and concrete work for foundation of panel including MS frame for mounting of panel well above the ground level - 1 jobNote: Drawing and make of LT panel and connected items to be approved by GE before placing the order. |
| 29 | Supply and laying of GI pipe heavy class 3 mtr large in flange joint after 3 mtr complete with rubber gasket, nuts, bolts, washer for column pipe to bore well of size 50 mm dia including necessary arrangements for coupling arrangement on top and bottom ofv GI pipe heavy class with pump and delivery pipe complete all as specified and directed. |
| 30 | S&F of steel rope in submersible bore wells from motor to top edge of the bore well of size 6 mm dia(multi wire stainless steel) for holding of submersible pump motor set all as specified directed. |
| 31 | Supply and fixing of pressure guage, 100mm size fitted on delivery side of pump set(0 to 10.6 kg/sqcm) complete with needle valve etc all as speified and directed. |
| 32 | M & L Pit masonary for valves and meters constructed complete with MS sheet cover and locking arrangement etc suitable up to 100 mm dia of size 900 x 900 X 900 mm complete all as specified and directed. |
| 33 | Carry out Resistivity test by the team of Central ground water board/State ground water dept. for define of water aquifier at 01 location in Depot area incluiding test report complete all as spicified and directed |
| 34 | EXTERNAL ELECTRIFICATION M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid. |
| 35 | Supply, install, testing and commissioning factory made (CPRI test certified) LT panel box out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 3.15 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 5 mm thick angle iron and 0.75 m long for base frame work.The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front and back opening type with approx size for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. (a) Incoming- MCCB 4 pole 63 A , 415V,16 KA adjustable type with magnetic release - 01 No. Outgoing (b) MCB TPN 40A , 415V,16 KA adjustable type with magnetic release - 01 No (c) MCB TPN 16 A , 415V,10 KA adjustable type with magnetic release - 05 No. (b) Digital Voltmeter size 96 x 96 mm, 0-600 volts with selector switch - 01 No. (c) Digital Ammeter size 96 x 96 mm 0-400 Amps, CTs, CTR 0-400 Amps with selector switch - 01 No. (d) Busbar alluminium 150A capacity for phase & neutral-04No. Note: panel mounted on 45 cm height pcc platform above ground level and 0.15 below ground level |
| 36 | Boring of holes under road, pavement, hard standing by manually and necessary machine for laying under ground pipe up 100mm dia completeNote :- GI pipe shall be measured and paid in concern Item |
| 37 | Supply, install, test and commissioning factory made THERMOPLASTIC CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal. |
| 38 | S&F street light GI bracket of 1.2 mtr long made out of 32 mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 40 x 6mm including nuts bolts & washers complete necessary fixing arrangements on pole as directed. |
| 39 | S&F of automatic street light switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation switch operation should be based on Natural light Lux level. Required illuminance level for Switching ON is<= 30 lux and for switching OFF>=10 lux. The sensor should also have part night operation facility of min 4 hours to max 12 hours. The sensor along with suitable Power contactors, incoming-outgoing MCB's and Auto manual(Sensor By-pass) selection option should be enclosed in apole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, termite proof and FR grade SMC Junction box conforming to IP54. For three phase load of 0.5KW(Swadeep--02EC-5kW3P) with: 1 Nos contactors,1 nos incoming MCB's & 1 nos outgoing MCB's of 6-32 Amps & circuit wiring (copper)of min 6/10 sqmm. |
| 40 | Providing cement concrete Dunnage block (30x30x20 cm) 1:2:4 type B-1(20 mm graded aggregate) |
| 41 | M&L for Sign board of size 1.20 X 1.2m on angle iron frame 40X40X6 mm and 3 mm thick plain sheet suported on 2.7m high angle Iron 65X65X6 mm fixed on PCC 1:2:4 block of size 1.50X0.45X0.45 over 100 mm thick surface of PCC 1:4:8 including necessary earth work complete and painting to steel surface and writing letter of height n.exc 15cm and 30 NOs in each board complete restricted area. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 24, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Sep 04, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysSep 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender