Tender For Special Repair To Bldg No T-119 Of C Comp Sig Regt At Mil Stn Kausani Under Ge Ranikhet
Tender Overview
Project Description
Tender For Special Repair To Bldg No T-119 Of C Comp Sig Regt At Mil Stn Kausani Under Ge Ranikhet
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-Aug-2026 |
| 2 | 04-Aug-2026 | CorrigendumNo1 | BOQ | 18-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantaling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & directed. |
| 2 | S&F Pre-painted galvaLume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screws complete all as specified and directed. |
| 3 | S&F Pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screws complete all as specified and directed. |
| 4 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 5 | S&F Anodised aluminium snap grid size 605 x 605 mm frame work for false ceiling all as specified and directed. |
| 6 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 7 | S & F 4 mm thick Everest designer ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 595 X 595 mm size fixed with staples on GI/Aluminium snap grid as in ceiling with and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed |
| 8 | Taking down wooden chowkhat or frame area not exc 1.5 sqm each with shutter (without taking off shutter from frame) as directed. |
| 9 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but n exc 4 sqm each complete all as specifed & directed. |
| 10 | S & F 2nd class Hard Wood plain solid straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints, and making good with existing surface as complete as specified and directed. |
| 11 | S&F 30 mm thick Flush shutters solid core construction with block board core and plywood face panels commercial type on both sides. |
| 12 | Supply and fixing 100 mm butt hinges medium weight cold rolled mild steel ISI marked fixed with wooden screws complete as specified and directed. |
| 13 | Supply and fixing 150 mm mild steel pressed handles, oval type, stove enamelled black and fixed with wooden screws, complete as specified and directed. |
| 14 | M&L for mild steel barrel tower bolts stove enameled black, with bright bolt length of bolt 150 mm (ISI marked) fixed complete fixed with screws,complete as specified and directed. |
| 15 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and thedirections of Engineer-in-Charge. |
| 16 | M& L for Powder Coating of any colour ( minimum thickness of Powder coating not less than 50 micron) Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 17 | S&F 10 mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required as directed by engineer-in-charge. |
| 18 | S & F Galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples, complete all as specified and directed. |
| 19 | S&F aluminium die cast body Door closer hydraulically regulated designation no,2 universal type suitable for door shutter of 701 to 850mm width and of weight between 36 to 60 kg ISI Marked complete. |
| 20 | S& F 100 mm size, Alluminium Mortice lock with 2 levers, vertical type complete all as specified & directed by Engr-in-charge. |
| 21 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as directed. |
| 22 | M&L for glazed ceramic coloured tiles 300x450mmx7mm thick on wall/vertical surfaces such as skirting, dados and riser to steps etc including laid over 10mm thick 1:3 cement mortar for laying wall/vertical finish set and jointed in neat cement slurry and pointed in white or coloured cement to match all complete all as specified & directed by Engr-in-charge. |
| 23 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness(below or above ground level) complete all as specified and directed. |
| 24 | M&L for Providing cement concrete type B-2, 1:2:4 (using 40mm graded aggregate) as in surface channel and drains complete all as specified & directed by Engr-in-charge |
| 25 | M&L for 75mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate ) as in sub base. |
| 26 | M&L for Vitrified ceramic tiles 9 to10 mm thick (Square / rectangular) light shade polished area of each tiles not exceeding 0.36 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the colour tiles complete all as specified & directed by Engr-in-charge. |
| 27 | M&L for Non skid Coloured ceremic tiles 7 to 8 mm thick (Square / rectanguler) area of each tile exceeding 0.06 sqm but not exeeding 0.11 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified & directed by Engr-in-charge. |
| 28 | M&L for Cement concrete type D-2 1:4:8 (40mm graded aggregate) in foundations, filling,sub base and mass concrete complete all as specified & directed by Engr-in-charge. |
| 29 | M&L for heavy duty tiles exterior grade 300 x 300 x 10mm including 15 mm thick screed bed in CM 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified & directed by Engr-in-charge |
| 30 | S&F in repair 25 mm dia curtain rod/harrison rails,mild steel, chromium plated fancy type fixed with end brackets, stops ,rollers & all connected accessories complete all as specified and directed. |
| 31 | Demolition of brick work masonry/precast block/stone masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excl ashlars facing,dressed stone work and pre-cast concrete articles complete all as specified & directed by Engr-in-charge |
| 32 | Taking down cement / lime plaster of any description on brick work or stone walls etc including racking out joints hacking for key scrubbing down with water etc.complete all as specified and as directed |
| 33 | M&L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified & directed by Engr-in-charge |
| 34 | M&L for rendering 15 mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified. |
| 35 | Supply only integral water proofing compound |
| 36 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified. |
| 37 | Dismantling mild steel or wrought iron work in roof trusses,gratings etc and similar work complete all as directed. |
| 38 | M&L Mild steel work in framed work such as grills, gratings, guard bars, doors etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 290.Gde-E-165, complete all as specified and directed. |
| 39 | M&L for mild steel work in roof trusses,purlins,rafters,wind ties,crane gantries,rails and fastenings and heavy bracket framing (Beam,Tee,Angle,Channel or Flat sections) including distance pieces,cleats etc complete all as specified and directed. |
| 40 | S&F for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment confirming to FE - 410 W(Gde E-250) Quality B complete all as specified. |
| 41 | M&L preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer, complete all as specified and directed. |
| 42 | Dismantling old plywood, prelaminated particle board / boarding, cupboard shelves or similar items of any description, fixed in any position all as specified and directed . |
| 43 | S & F in repairs 6mm thick decorative PVC Sheet hollow (design approved by GE) for insulation and acoustic purpose on wall surface, screw to timber frame work for levelling of wall as reqd, including with panelling to vertical surfaces, fixed with rawl plug and screws complete all as specified and directed. |
| 44 | M& L for 18/19 mm thick Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and directed |
| 45 | M&L preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of Pink primer complete all as specified and directed. |
| 46 | Dismantling PVC water tanks and removing from site capacity for exc 250 ltrs but n. exc 500 ltrs complete all as specified and as directed. |
| 47 | M&L for rotational moulded polyethylene water storage tank 500 ltrs capacity double layered cylindrical vertical with closed top hoisted and fixed in position including fittings all as specified and as directed. |
| 48 | Dismantling fencing wire mesh, any type Complete all as specified and directed. |
| 49 | S&F 2mm thick Fibre glass reinforced translucent corrugated / Plain sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etcand making good Complete all as specified and directed. |
| 50 | S&F in repair single piece EWC combined with flushing cistern, waste pipe, trap, seat cover, jet spray including all necessary accessories, fittings & bolts complete all as specified & directed. Make- Jaguar lyric single piece EWC P-180 Complete all as specified and directed. |
| 51 | S&F in repair bathroom tabletop ceramic washbasin (Size not less than 500x300x125mm) over marble counter and BWR plywood cabinet (white) as approved by GE with waste pipe, coupling and fittings complete all as specified & directed. Make- As approved by GE |
| 52 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons laid, bedded, pointed in mortar etc complete all as specified & directed. |
| 53 | M&L Granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in and including cement mortar backing CM (1:4),20 mm thick, including molding, pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed. |
| 54 | S&F in repair Vitreous china Urinal, Half stall type, white with waste pipe and CP brass spreader complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plug with and including 60mm long brass screws, pointing around urinal back in cement; flush pipe, grating and union for discharge pipe including Cp Urinal spreader for fixing with 15 mm dia pipe complete all as specified. |
| 55 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 56 | Supply and fix in repair for corner glass shelf of size 300mm dia and 8mm thick with chromium plated railing, fixed with and including chromium plated bracket complete all as specified and as directed. |
| 57 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with CP brass screws & cup washers complete all as specified & directed. |
| 58 | S&F in repair Tubular Brass chromium plated towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified & directed. |
| 59 | S&F in repair soap dish tray embedded in wall , vitreous china white, approximate size 160x160x90 mm complete all as specified & directed. |
| 60 | S&F in repair Toilet paper holder with flat recessed type stainless steel fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.\\" |
| 61 | S&F in repair 15 mm dia bib tap cast copper alloy, fancy type chromium plated ,'with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule all as directed. |
| 62 | S & F in repairs 15 mm bore Fancy type Telephonic Shower (Healthfaucet), Cast Copper alloy, with chromium plated, screwed down high pressure with or without lettered Hot or Cold with lenght not less than 1.0mtr long screwed shanks and fly nuts, screwed for iron pipe/stop value and fixed as Cat No 455, make:- Prayag or equavalent as approved by GE. |
| 63 | S&F in repair brass CP Stop valve/ Angle valve 15 mm fancy type with long shank and cup fixed complete all as specified & directed. |
| 64 | S&F in repair 15mm bore fancy type chromium plated central hole wash basin mixer with 450mm long braided hoses,screwed down high pressure with or without lettered hot and cold srcrewed for iron pipe complete all as specified & directed. Make-Jaguar or equivalent approved by GE |
| 65 | S&F in repair PVC connection 15mm size with brass nuts of length 450mm complete all as specified & directed. |
| 66 | S&F 20mm bore ball valve, high pressure with epoxy coated aluminium rod and high density plastic vavle screwed for iron pipe and fixed of 20mm dia (min wt 210 grms) complete all as specified and directed. |
| 67 | Taking down Cast iron floor trap 100& 75 mm size, P or S including grating etc. |
| 68 | M&L for Cast iron 75mm floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified & directed. |
| 69 | Taking up 80mm bore pipes cast iron water mains (including all fittings), with spigot and socket ends and lead joints includingburning out joints and recovering lead complete all as specified and as directed |
| 70 | Taking up 100 mm bore pipes cast iron water mains (including all fittings), with spigot and socket ends and lead joints includingburning out joints and recovering lead complete all as specified and as directed |
| 71 | S&F in repairs 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors. |
| 72 | S&F in repairs 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors. |
| 73 | S&F in repairs 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to walls. |
| 74 | S/F PVC (SWR)vent cowl of size 110mm bore |
| 75 | S&F PVC (SWR) plain bend 110 mm dia, of any redius with rubber ring joints, complete all as specified and as directed |
| 76 | S&F PVC (SWR) plain bend 75 mm dia, of any redius with rubber ring joints, complete all as specified and as directed |
| 77 | S&F 75mm dia PVC (SWR) junction single, (Single T) equal or unequal |
| 78 | S&F 100 mm dia PVC (SWR) junction single, (Single T) equal or unequal |
| 79 | Taking up or down 15 mm bore steel tubing and connections, complete all as specified and as directed |
| 80 | Taking up or down 20 mm bore steel tubing and connections, complete all as specified and as directed by Engr-in-charge. |
| 81 | Supply and fix 15 mm bore galvanized steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line all as specified and as directed by Engineer-in-Charge. |
| 82 | Supply and fix 20 mm bore galvanized steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line all as specified and as directed by Engineer-in-Charge. |
| 83 | Demolition and breaking up 150 mm dia bore salt glazed stoneware drain pipe including PCC packing under haunching against the sides of pipe bed and complete PCC of bed and removal of debris to a distance exc 1.0 Km but n.exc 2.0 Km all specified and directed. |
| 84 | M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in bedding including haunching & packing under and against the side of reinforced concrete pipes, class NP2,150 mm bore, after they are laid and tested complete all as specified & directed by Engr-in-charge. |
| 85 | Supply, laying, jointing and testing for 150 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints drain pipe (ISI Marked) of approved make laid in trenches jointed in CM (1:1) complete all as specified and as directed |
| 86 | Demolition of RCC of any description and in any position (reinforcement cut as required to facilitate demolition) complete all as specified & directed by Engr-in-charge. |
| 87 | M&L for RCC pre-cast type B-1 (1:2:4) (using 20mm graded crushed stone aggregate ) as in cover slabs for manholes etc set in cement mortar (1:4) complete all as specified and directed by Engr-in-charge. NOTE: Reinforcement for cover slabs will be provided under respective item separately. |
| 88 | M&L for mild steel TMT bars 10 mm dia & over cut to length bent to shape required including cranking bending spirally for hooping columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-charge. |
| 89 | BOQ ( Sch A ) Internal Electric worksTaking down carefully copper / aluminium point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, sockets, lamp holders, brackets, bulk head fittings, tube light fittings etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and white / colour wash etc. complete all as specified and directed. |
| 90 | M & L in replacement to point wiring for Modular fittings for one light point/ fan/ bell/ 5Amps socket out let (independent)point controlled by one, one way switch with 1.5 sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLSH) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia)with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed (a) One light/One fan/one bell point controlled by one modular switch |
| 91 | (b) One modular socket outlet 3 pin 6 amps controlled by one switch on same board. |
| 92 | (c) One modular socket outlet 3 pin 6 amps controlled by one switch on independent board. |
| 93 | All as per item No 92 herein before but wiring with 2.5 sqmm copper wire (FRLS) PVC and 2.5 sqmm earth wire for modular socket outlet 5 pin 16 amps on independent board. |
| 94 | S&F in replacement of white cover plate with frame, 1 module complete all as specified and directed |
| 95 | S&F in replacement of white cover plate with frame, 3 module complete all as specified and directed |
| 96 | S&F in replacement of white cover plate with frame, 4 module complete all as specified and directed |
| 97 | S&F in replacement of white cover plate with frame, 6 module complete all as specified and directed |
| 98 | S&F in replacement of white cover plate with frame, 8 module complete all as specified and directed |
| 99 | S&F in replacement of Modular Metal flush box, 1/ 2 module complete all as specified and directed |
| 100 | S&F in replacement of Modular Metal flush box, 3 module complete all as specified and directed |
| 101 | S&F in replacement of Modular Metal flush box, 4 module complete all as specified and directed |
| 102 | S&F in replacement of Modular Metal flush box, 6/8 module complete all as specified and directed |
| 103 | Supply and fix in replacement to modular type switch single pole, one way 6 Amp complete all as specified and directed. |
| 104 | Supply and fix in replacement to socket out let multi 5 pin, 6 Amps, modular type complete all as specified and directed. |
| 105 | Supply and fix in replacement to switch modular type single pole, one way 16 Amp complete all as specified and directed. |
| 106 | Supply and fix in replacement to socket out let 2 in1,3 pin, 6 and 16 Amp, modular type complete all as specified and directed. |
| 107 | Supply and fixing in replacement to ceiling rose, PVC / polycarbonate isolated body three terminal complete all as specified and directed. |
| 108 | Supply and fixing in replacement to lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / wall fittings complete all as specified and directed. |
| 109 | S & F in replacement to LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. complete all as specified and directed. |
| 110 | Supply and fixing in replacement to amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN of 32 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 111 | Supply and fixing in replacement to 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing andcommissioningcomplete all as specified and directed. |
| 112 | Supply and fixing in replacement to amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN of 40 to 63 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 113 | S & F in replacement of sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 8 ways with 200 ampere rated bus bar, 240 volts fixed sunk/flush to the wall or niche complete all as specified and directed. |
| 114 | Supply and fixing in replacement to LED lights fitting 1x 20W (T-5), 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 115 | S & F in replacement to Decorative, wall mounting, brushed nickel finish fixture with opal glass diffuser suitable with 9 W LED lamp B22 base complete all as specified and directed.Make : Havells Cat Part No LHFOAJE1TN1I060 HSN Code: 94051900 or equavalent |
| 116 | Supply and fixing in replacement to LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 117 | Supply and fixing in replacement to 10 Watt garden light unique concept LED Bollard in IP 66 to ensure sustainable performance in all section and aesthetics which keeps the surrounding lively incl required excavation and PCC work (1:3:6) type C-2 complete all as specified and directed.Make : Havells (Cat Part-TURINBLS10WLED830PSYMTOPC or equivalent) |
| 118 | Supply and fixing in replacement to 15 Watt gate light aesthetically designed IP 65 LED post top with aluminium enclosure, powered with high power LEDs as light source and die casted heat sink exhibits classic Victorian look with symmetrical light distribution and excellent heat dissipation for long life including PCC work (1:3:6) type C-2 as required complete all as specified and directed.Make : Havells (Cat Part-JUPITERMAXIPT50WLED830PSYMTOPC or equivalent) |
| 119 | Supply & Fixing in replacement bldg security light luminaires including 25 watt LED street light for 220-230 V, 50 Hz with IP 65 protection including bracket for fixing in wall, made of 25mm bore light grade GI Pipe connecting up with three core twisted flexible copper conductor cable complete all as specified and directed. |
| 120 | Supply and fixing Geyser 25 Ltr Capacity SS Tank, BEE five star rating with Digital Temperature Display & heating element upto 2 KW, ISI mark, with all accessories such as safety valve, thermostate, NRV, stop valves, cast copper alloy 15 mm dia fancy type,15mm bore bib taps, cast copper alloy with crutch or butterfly handle, connection piece etc, necessary PVC connection pipe of 15mm size with PTMT nuts and making good as per existing surface Complete all as specified and directed.Make: Havells (Velora+ Dual Element), Product Code:GHWVVEDMEW25, HSN Code: 8516 or equvalent |
| 121 | S&F exhaust fan, made of sturdy Engineering plastic complete, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 250m with self-louvers shutters with frame, AC single phase 230 Volt, grouting both ends in wall up to required length, including making hole of suitable size & making good disturbed surfaces of wall to match the existing surface & and removing the rubbish / debris to a distance as directed by Engr-in-Charge and connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to exhaust fan, complete all as specified and as directed |
| 122 | Supply, laying, jointing and commissioning 16 Sqmm 2 core LT XLPE 1100 volts grade heavy duty cable PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes,induct, on pole and roads etc of following sizes :- |
| 123 | Excavation in trenches in hard/dense soil not exc 1.5mtrs wide and not exc. 1.5m in depth for laying cables and getting out incl jointing bottom surface to the reqd level/slope etc complete all as specified and directed. |
| 124 | Return filling in incl spreading, leveling,watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed. |
| 125 | Removing excavated material to a distance not exc 50 mtr and deposited where directed at a level not exc 1.5 mtrs above the starting point all as specified and directed. |
| 126 | M&L for laying of fine river sand, free from sharp material for cable cushioning in trenches all as specified and directed. |
| 127 | Supply and laying of sub class 'B' old size bricks as in cable protection in trenches complete all as specified and directed. |
| 128 | Supply and fixing / laying of galvanized iron pipe of 32 mm bore nominal bore light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc with clamps nuts, bolts and washers complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall deemed to be included in the unit rate quoted by contractor. |
| 129 | M&L for earthing complete with galvanised steel, earth plate electode 600x600x6mm thick buried directly in gournd ( earth pit not less than 2.25mtrs below ground level ) with the top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 423 of MES schedule 2010 Part II connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all-round the GI earth plate, watering pipe 20 mm dia GI medium grade, GI sheet 0.63 mm thick funnel, wire, gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round suitable lifting handle to cover, GI protection pipe 15mm dia 'light grade' upto 7.5 Mtr from electrode etc, complete all as specified and directed including testing on completion. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender