Tender For Construction Of 33/11 Kv Gss Hamirgarh And Associated 33 Kv And 11 Kv Line Works In Aen (R-I) Bhilwara Sub-Division Of Ajmer Discom.

Issued by Government Departments · Ajmer, Rajasthan
Tender Value
12.75 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
9 days left
EMD
25500
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ajmer → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 33/11 Kv Gss Hamirgarh And Associated 33 Kv And 11 Kv Line Works In Aen (R-I) Bhilwara Sub-Division Of Ajmer Discom.

BOQ

Name of Work:- Construction of 33/11 KV GSS Hamirgarh and associated 33 KV and 11 KV line works in AEN (R-I) Bhilwara Sub-division of Ajmer Discom.
Sl. No. Item Description
1Construction of 33/11KV GSS
2Levelling of ground
3Levelling of ground up to 30 cm.depth. with tractor and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder.(Including all lead & lifting)
4Levelling of ground above 30 cm.to 90 CM.depth. with tractor and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder.(Including all lead & lifting)
5Trimming of tree branches/plants and preparing route approchases for proposed line.
6Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
79 Mtr/ 1.2mx0.6mx1.50 m deep
8(C)Stay set/Depth of pit
98'x 3/4\\" -0.75x0.5x1.6 m
106'x 5/8\\" -0.75x0.5x1.35 m
11Excavation of pit in Hard rock ( Where blasting is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
129 Mtr/ 1.2mx0.6mx1.50 m deep
13(C)Stay set/Depth of pit
148'x 3/4\\" -0.75x0.5x1.6 m
156'x 5/8\\" -0.75x0.5x1.35 m
16Earth work excavation and foundation of platfrom of transformers and brakers including dressing of sides and ramming of bottoms .Liftup to 1.5 Meter including taking out the excavated soil and depositing and refilling of jhiri, watering and ramming and disposal of surplus excavated soil as directed with in a lead of 50 Meter.
17Hard/dense soil
18Hard soil mixed with boulders
19Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken) in foundation plinth excluding the cost of shuttering using 1 cement : 5 sand : 10 aggregate mix.Note :1. The rates are all lead of cement, lime, ballast, sand, surkhi and grit etc. at site of work.2. For all concrete work coarse sand shall be used no extra will be paid .3. Concrete mix prepared by power driven mechanical mixer shall be used .4. Under exceptional coditions, where mechanical mixer and vibrator are not used (with the approval of Engineer Incharge reduced by 3% for mechanical mixer and 2% for Vibrator.5. Thickness of the cement concrete should not exceeed 100 mm.
20Plaster on new surface on walls in cement, sand mortar 1:6 including racking of joint etc. complete fine finsh 25 mm thick.Note :1. The rates for complete work including racking of joints, curing, grinding, mixing and finishing T&P and scaffolding material and cost of material with all lead and lift.2. The rates cover protection of all place and things, requiring protection and cleaing such places and thing of all droppings and splashes of mortar etc.
21Cement concrete flooring grade 1:2:4 (1-cement :2- coarse sand :4-graded stone aggregate ) rounding off edges etc.but excluding cost of nosing of steps etc. complete.Note :1. The rates for all items inculde all form of work, laying, curing and finishing etc. The rates are for complete work at site, inclusive of all leads.2. The rates cover the preparation and cleaing of all places
2225 mm thick with 12.5 mm thick nominal size aggregate.
2375 mm thick with 20 mm thick nominal size aggregate.
24Masonry for foundation and plinth
25Randon Rubble stone masonry for foundation and plinth in cement sand mortar 1:6(1 Cement : 6 Sand) including labour charges.
26Brick masonry for foundation and plinth in Cement sand mortar 1:6 ( 1 Cement : 6 Sand ) including labour charges.
27Safe carriage of PCC poles including loading / un-loading
28a) 9 Mtr. Long-400 Kg /11 Mtr. PCC pole
29Within 10 Kms.
30Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
31c) 9 Mtr.long 200 Kg. PCC pole
32within 10 Kms.-
33Above 10 Km. & upto 30 Km. add for each Km. or part thereof
34Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
35Within 10 Kms.
36Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
37Above 30 Kms. Add for each Kms. or part thereof.
38Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
39Within 10 Kms.
40Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
41Above 30 Kms. Add for each Kms. or part thereof.
42Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.
43Within 10 Kms.
44Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
45Above 30 Kms. Add for each Kms. or part thereof.
46Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading.from store to site(b) 25 & 40 KVA
47Within 10 Kms.
48Above 10 Kms. & upto 30 Kms Add for each Km.or part thereof.
49Above 30 Kms. Add for each Kms. or part thereof.
50Safe Carriage of 33/11 KV Power Transformer (b) Above 1.6 MVA & Upto 3.15 MVA
51Within 10 Kms
52Above 10 Kms & upto 30 Kms . Add for each Km or partthereof
53Above 30 Kms & upto 50 Kms . Add for each Km or partthereof
54Above 50 Kms . Add for each Km or part thereof
55c) 5.0 MVA
56Within 10 Kms
57Above 10 Kms & upto 30 Kms . Add for each Km or partthereof
58Above 30 Kms & upto 50 Kms . Add for each Km or partthereof
59Above 50 Kms . Add for each Km or part thereof
60Safe carriage of breakers/kiosks etc. including loading/ unloading and stacking in Nigam stores
61Within 10 KMs.
62Above 10 Kms. and upto 30 Kms.Add per each km,or part thereof
63Above 30 Kms. Add for each Kms. or part thereof.
64Safe Carriage of 33/11 KV Power Transformer
658.0 MVA
66Within 10 Kms
67Above 10 Kms & upto 30 Kms . Add for each Km or partthereof
68Above 30 Kms & upto 50 Kms . Add for each Km or partthereof
69Above 50 Kms . Add for each Km or part thereof
70Safe loading of power/ distribution transformer.
71Above 1.6 MVA & upto 3.15 MVA
72Above 3.15 MVA & upto 5.0 MVA
73Above 5.0 MVA Amendment reference D.810 dt.10.10.16
74Safe unloading of power/distribution transformers
75Above 1.6 MVA & upto 3.15 MVA
76Above 3.15 MVA
77Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.
78(B) IN RURAL AREA
79PCC Poles 9 Mtr. Long (400 Kg)
80PCC Poles 9 Mtr. Long(200Kg.)
81Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of top bracing of M.S.Channels with pilot plates and clamps.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.
82PCC Poles 9 Mtr. Long(200 Kg.)
83Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire
848\\"x3/4\\" with 7/8 SWG stay wire
856\\"x5/8\\" with 7/10 SWG stay wire
86Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.
87Fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub-station.
88Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware and strips.
89Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 1nos.disc.& 1set of H/ W ) on terminal point including fixing of hardware and strips.
90Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 2 nos.disc.& 1set of H/ W ) on terminal point including fixing of hardware and strips.
91Fixing of 33kv pin insulator with pins.
92Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates. (B)G.O. switch . without earthing blade.
9333kv G.O.switch
9411kv G.O.switch
95Assembly and installation of Horn Gap fuse set (set of 3nos)on erected structure as per design, complete in all respectwith post insulator including jumpering on both ends for connection with the system. The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
9633kv Horn Gap fuse set.
9711kv Horn Gap fuse set.
98Installation of lightening arrestors on erected structure /support (set of 3 nos) including connection with earth by wire /strip as required and jumpering etc. The nuts & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates, (A)sub-station type
9933 KV L.A. set ( 1set=3 Nos)
10011 KV L.A. set ( 1set=3 Nos)
101Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of base channels as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,
10225 and 40 KVA
103Fixing of danger plates on supports/structure
104Fixing of PG clamp of Weasel /Rabbit Conductor
105Fixing of PG clamp of Dog /Racoon Conductor
106Assembly,installation & commisioning of 11 KV Roaster switchs on erected structures with stting for accurate operation including fixing of allied accessories completed in all respect with post insulators and jumpering on both ends for connection with systm.The nuts & bolts will be supplied by contractor for which payment will be made as per prevailing Dicom store issue rates.
107Three no. Earthing of 11/0.4 KV distribution transformer /sub-station with M.S.Rod 20mm dia each 3 meter long and driving them into earth by mechanical means at a distance as per approved design & drawing & specification.The work includes flattening of top ends of M.S.rod drilling a hole of 9/16\\" dia.at flattened top and tightening of M.S.flat 50x6mm/25x3 mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with M.S.rods top end hole.The flat will also be welded with M.S.rod.The end will be connected to equipments as under in sequence.
108Mesh earthing for 33/11 kv sub-station as per approved map &design usingMS flat 50X6mm/MS road 20mm dia includinglaying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints , structures & equipments etc.asunder:
109Excavation of trench of 0.65Mtrs.depth and 0.5Mtr.width
110Hard Soil
111Ordinary rock ( where blasting is not required.)
112Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.
113Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earth mesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.
114Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be driven in earth by mechanical means and Providing & .fastening of suitable clampswith the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil:
115Where drilling is required
116Filling of trench with available excavated muck in layers of 20cm (Max.)consolidating each deposited layer by ramming & watering with lead up to 50 Mtr, and lift up to 1.5 Mtr.
117Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.
118Earthing of new 33/11 KV S/S with bentonite compound (including material ) involving following activities. (8.5.1 TO 8.5.6 COVERED)
119Pipe Earthing for Power Transformer at 33/11KV S/S :-Supply and erection of earthing electrode shall consist of G.I. Pipe 100 mm, of 3 Mtr. Length. The electrode shall be buried as far as practicable 3 Meters below ground level. Wherever possible earth electrodes shall be located as near the water tap, water drain or near down take pipe. Earth electrodes shall not be installed in proximity to a metal fance. It shall be kept clear of the bulidings foundations and in no case it shall be nearer than 2 Mtr. from the outer face of the wall. The electrode shall be surrounded with layer of charcoal dust and salt mixture through out the length. The 100 mm G.I. pipe shall be provided with holes of 12 mm Dia drilled at 75mm interval upto 2.5 meters length from bottom. The top of the pipe shall be provided with a G.I. threaded cap for watering the earth through a pipe. A clamp with pati of 12\\" of M.S. Flat of size 50x6 mm shall be fixed (Bolted) on the top age of the pipe which in turn shall be connected Neutral/Body of the Power Transformer through M.S. Flat size 50x6 mm. The G.I. cap over the G.I. Pipe shall be housed in a masonry chamber, approximately 300 mm x 300 mm x 300 mm deep. The masonry chamber shall be provided with a RCC Inspection cover resting over a RCC frame, embedded in masonry.
120Erection of PCC poles in excavated pit in alignment after checking the same with plumb line as per approved design & drawing of 33/11kv sub-station.The pit should be back filled with the soil with proper ramming below 30cm ground level and then muffed above 15cm average ground level with cement concrete ratio1:3:6.The charges for muffing will be paid extra as per chapter code no 5.7 The nuts & bolts will be supplied by the contractor for which payment will be made at the prevailing store issue rates. (B) IN RURAL AREA
121PCC Poles 9 Mtr. Long
122Laying / stringing of bus bar with ACSR Dog & jumper connection using tie rod ,33KV /11KV insulator strings,required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.
123ACSR Panther
124ACSR DOG/RABBIT
125Supply, stacking & spreading of stone boulders 40 mm. Mono size.(Less voids 17%)
126Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.
12733 KV VCB/SF-6 Breaker
12811 KV VCB (Outdoor )
129Installation of current/potential transformers on supporting structure including checking of wiring & conducting all pre-commissioning tests before energization & satisfactory operation in all respect (The CT/PT set will be tested by Discom).
13033 KV CT(1 set of 3 Nos.) OR PT Set
13111 KV CT(1 set of 3 Nos.) OR PT Set
132Laying, testing termination of control cable 1100 volts PVC insulated including supply and installation of ferrules to designate various cores of control cables by terminal Nos. of identification including utilization of cable gland. The control cable should be clearly arranged in trenches avoiding crossings including clamping of control cable at regular interval and providing identify tags.
13312x2.5 Sq.mm.
134Installation of metering points on 11 KV Out going feeder at 33/11 KV S/S.(a to g)
135Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)
136On new surface
137Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)
138On new works with two coats.
139Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling as per design and drawing.
140Other steel items
141Drilling of holes in MS Channel / Angle /Flat
14215/16\\" dia holes(23.81 mm dia.)
143Transportation of CT/PT set (all size) including loading and unloading from Nigam store to site
144(a) Within 10 Kms.
145(b) Above 10 Km upto 30 Km. Add for each Km. or part there off
146Supply of MS nuts & bolts
147Supply of PG Calmps
14833 KV Line work Annexure -B
149Conducting route survey as per approved route map and pegging of route with tee off point section point & double pole locations.
150Trimming of tree branches/plants and preparing route approchases for proposed line.
151Excavation of pit in soil (ordinary) to erect various supports and stay sets including stacking of excavated soil from the edge of excavation.
152(A) Height of poles/R.S.Joist/M.S. Rail Size of pit
1539 Mtr/ 1.2mx0.6mx1.50 m deep
154(B) Lattice Tower /Size of pit
15511.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
15612.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
157(C)Stay set/Depth of pit
1588'x 3/4\\" -0.75x0.5x1.6 m
159Excavation of pit in Hard soil
160(A) Height of poles/R.S.Joist/M.S. Rail Size of pit
1619 Mtr/ 1.2mx0.6mx1.50 m deep
162(B) Lattice Tower /Size of pit
16311.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
16412.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
165(C)Stay set/Depth of pit
1668'x 3/4\\" -0.75x0.5x1.6 m
167Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
168(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
1699 Mtr/ 1.2mx0.6mx1.50 m deep
170(B) Lattice Tower /Size of pit
17111.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
17212.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
173(C)Stay set/Depth of pit
1748'x 3/4\\" -0.75x0.5x1.6 m
175Excavation of pit in Hard rock ( Where blasting is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
176(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
1779 Mtr/ 1.2mx0.6mx1.50 m deep
178(B) Lattice Tower /Size of pit
17911.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
18012.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
181(C)Stay set/Depth of pit
1828'x 3/4\\" -0.75x0.5x1.6 m
183Safe carriage of PCC poles including loading / un-loading
184a) 9 Mtr. Long-400 Kg /11 Mtr. PCC pole
185Within 10 Kms.
186Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
187Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
188Within 10 Kms.
189Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
190Above 30 Kms. Add for each Kms. or part thereof.
191Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
192Within 10 Kms.
193Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
194Above 30 Kms. Add for each Kms. or part thereof.
195Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.
196Within 10 Kms.
197Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
198Above 30 Kms. Add for each Kms. or part thereof.
199Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.
200Lattice Structure
201Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.
202Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.
203PCC Poles 9 Mtr. Long (400 Kg)
204Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of top bracing of M.S.Channels with pilot plates and clamps.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.
205PCC Poles 9 Mtr. Long(400 Kg.)
206Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire
2078\\"x3/4\\" with 7/8 SWG stay wire
208Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.
209(B) IN RURAL AREA
210ACSR Panther
211ACSR DOG
212Fixing of 33kv pin insulator with pins.
213Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.
21433 KV line
215Laying , jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
216(A).In Urban Area
217G.I.Earth wire 6 SWG
218G.I.Earth wire 8 SWG
219(A).In Rural Area
220G.I.Earth wire 6 SWG
221G.I.Earth wire 8 SWG
222Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod20mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing &specification.All material except MS rod,MS flat & stay wirewill be supplied by the contractor.If material is supplied by the contractor ,the payment will be made as per prevailing Discomstore issue rates.(In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)
223Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware and strips.
224Supply of MS nuts & bolts
225Supply of PG Calmps
226Fixing of PG clamp of Dog /Racoon Conductor
227Fixing of PG clamp of Panther Conductor
228Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling as per design and drawing.
229Other steel items
230Drilling of holes in MS Channel / Angle /Flat
23115/16\\" dia holes(23.81 mm dia.)
232Laying of 33 KV XLPE Cable ( Aluminium Conductor ) underground as per relevant ISS / AVVNL standard including excavation of 30 cm width x120 cm deep trench in Kaccha land 25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.
233B) 3x240 Sq mm to 3x400 Sq mm
234Note:- Per mtr. Rate shall be paid extra for excavation of puccka road
235Laying of two ( D/C) 33KV, XLPE (Aluminium conductor) undrground cables w/o overlapping as per relevant IS/ AVVNL standard including excavation of 50 cm width x 120 cm deep trench in Kaccha land.25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.
236A) 3x50 Sq mm to 3x185 Sq mm
237B) 3x 240 Sq mm to 3x400 Sq mm
238Note:- per meter shall be paid extra for excavation in Pakka Road.
239Laying of 33 KV & 11KV XLPE cable without Road cutting i.e. through burrowing machine \\"VERMIER\\".(120 cm deep).Use of this technology must be restricted to the situation like:-
240(iii)When cable laid in a HDPE pipe
24133 / 11 KV 3C x 300 Sq.mm cable
242Add Cost of 200 HDPE pipe
243(b) HDPE DWC pipe(IS-14930)
244Intallation of 33 KV Cable (XLPE) termination / straight through joints ( Heat shrinkable type) as per manufacturer's kit guidance and direction including preparation of cable and testing refilling etc as required.(Including crimping of lugs)
245A) (ii) 3x240 Sq mm to 3x400 Sq mm
246C) (ii) Straight through joint 3x240 Sq mm to 3x400 Sq mm
247Providing and fixing of G.I. Pipe of 150 mm diameter. B-Class (IS:1239 mark),at the starting and finishing point of 33 KV under ground cables and to lay & clamp vertically with the existing support including labour charges.
24811 KV Line work Annexure -C
249Conducting route survey as per approved route map and pegging of route with tee off point section point & double pole locations.
250Trimming of tree branches/plants and preparing route approchases for proposed line.
251Excavation of pit in soil (ordinary) to erect various supports and stay sets including stacking of excavated soil from the edge of excavation.
252(A) Height of poles/R.S.Joist/M.S. Rail Size of pit
2539 Mtr/ 1.2mx0.6mx1.50 m deep
254(B) Lattice Tower /Size of pit
25511.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
25612.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
257(C)Stay set/Depth of pit
2586'x 5/8\\" -0.75x0.5x1.35 m
259Excavation of pit in Hard soil
260(A) Height of poles/R.S.Joist/M.S. Rail Size of pit
2619 Mtr/ 1.2mx0.6mx1.50 m deep
262(B) Lattice Tower /Size of pit
26311.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
26412.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
265(C)Stay set/Depth of pit
2666'x 5/8\\" -0.75x0.5x1.35 m
267Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
268(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
2699 Mtr/ 1.2mx0.6mx1.50 m deep
270(B) Lattice Tower /Size of pit
27111.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
27212.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
273(C)Stay set/Depth of pit
2746'x 5/8\\" -0.75x0.5x1.35 m
275Excavation of pit in Hard rock ( Where blasting is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
276(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
2779 Mtr/ 1.2mx0.6mx1.50 m deep
278(B) Lattice Tower /Size of pit
27911.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
28012.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
281(C)Stay set/Depth of pit
2826'x 5/8\\" -0.75x0.5x1.35 m
283Safe carriage of PCC poles including loading / un-loading
284c) 9 Mtr.long 200 Kg. PCC pole
285within 10 Kms.-
286Above 10 Km. & upto 30 Km. add for each Km. or part thereof
287Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
288Within 10 Kms.
289Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
290Above 30 Kms. Add for each Kms. or part thereof.
291Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
292Within 10 Kms.
293Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
294Above 30 Kms. Add for each Kms. or part thereof.
295Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.
296Within 10 Kms.
297Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
298Above 30 Kms. Add for each Kms. or part thereof.
299Fixing of 11 KV pin insulator with pins.
300Fixing of 11kv B&S /T&C type disc insulator of 11kv lines (each unit consiting of 1nos.disc.& 1set of H/W ) on terminal point including fixing of hardware and strips.
301Fixing of PG clamp of Weasel /Rabbit Conductor
302Fixing of PG clamp of Dog /Racoon Conductor
303Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates. (B)G.O. switch . without earthing blade.
30433kv G.O.switch
30511kv G.O.switch
306Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod20mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing &specification.All material except MS rod,MS flat & stay wirewill be supplied by the contractor.If material is supplied by the contractor ,the payment will be made as per prevailing Discomstore issue rates.(In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)
307Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling and continunous welding joint as per design and drawing.
308Other steel items
309Drilling of holes in MS Channel / Angle /Flat
31015/16\\" dia holes(23.81 mm dia.)
311Supply of MS nuts & bolts
312Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.
313Lattice Structure
314Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.
315Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.
316(B) IN RURAL AREA
317PCC Poles 9 Mtr. Long(200Kg.)
318Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of top bracing of M.S.Channels with pilot plates and clamps.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.
319PCC Poles 9 Mtr. Long(200 Kg.)
320Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire
3216\\"x5/8\\" with 7/10 SWG stay wire
322Fixing and assembly of disc.point channel pair with pilot plates top hampers & clamps on erected single pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates,
32311 KV line
324Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.
325(B) IN RURAL AREA
326ACSR DOG
327ACSR RABBIT
328ACSR WEASEL
329INSULATED RABBIT HT/LT
330Supply of PG Clamps
331Laying of 11 KV, XLPE, Cable (Aluminium conductor) underground as per relevant IS/AVVNL standards including excavation of 30 cm x 120 cm deep trench in Kaccha land 25 cm thick under layer of sand. 'A' class beicks covering refilling soil in the remaining(Including fixing of G.I.Pipe of required size at both end with 3 Mtr projected above the ground surface & 0.3 Mtr. below ground level)
332A) 3x50 Sq mm to 3x185 Sq mm cable
333Note:- Per mtr. Rate shall be paid extra for excavation of puccka road
334Laying of two (D/C) 11 KV, XLPE, Cable (Al. conductor) underground cable w/o overlapping as per relevant IS/AVVNL standards including excavation of 50 cm width x120 cm deep trench in Kaccha land, 25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.
335A) 3x50 Sq mm to 3x185 Sq mm cable
336Note:- per meter shall be paid extra for excavation in Pakka Road.
337Laying of 33 KV & 11KV XLPE cable without Road cutting i.e. through burrowing machine \\"VERMIER\\".(120 cm deep).Use of this technology must be restricted to the situation like:-
338(iii)When cable laid in a HDPE pipe
339B) 33 / 11 KV below 3C x 300 Sq.mm cable
340Add Cost of 200 HDPE pipe
341(a) HDPE DWC pipe(IS-14930)
342Installation of cable termination / straight through joints on 11KV Aluminium conductor XLPE /PILCA Cable with outdoor/ indoor termination end and /or straight through joint including required excavation / remoral/ fixing / refixing/ testing etc. as required
343A) (I) Outdoor end terminal 3x35 Sq mm to 3x185 Sq mm
344C) (I) Straight through joint 3x35 to 3x185 Sq mm
345Providing and fixing of G.I. Pipe of 125 mm diameter. B-Class (IS:1239 mark),at the starting and finishing point of 11 KV under ground cables and to lay & clamp vertically with the existing support including labour charges. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56718182
AUTHORITY Government Departments
TENDER VALUE 12.75 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Ajmer Vidyut Vitran Nigam Limited
Work Description Tender for Construction Of 33/11 Kv Gss Hamirgarh And Associated 33 Kv And 11 Kv Line Works In Aen (R-I) Bhilwara Sub-Division Of Ajmer Discom.
Basic Detail
Tender No AJD/SE/TW/TN-468/Lot-4
Bidding Type Tender
Location
City Ajmer
State Rajasthan
Key Dates
Publish Date 29 Jul 2026
Submission Date 10 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value 12.75 Lakhs
Tender Fee 2950
EMD 25500
Exemption Not Available
Document List
327e4b79-e797-4225-942b-9cc55ee08050.html
BOQ_1028546.xls
TechnicalSpecificationTN468.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

327e4b79-e797-4225-942b-9cc55ee08050.html

xls

BOQ_1028546.xls

pdf

TechnicalSpecificationTN468.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders