Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56716445

Tender For Proposed Infrastructure Development Of Kalkalia High School At Kalkalia Under Mohanpur West Tripura Sanctioned Under Ridf Xxix Sh Construction Of New Double Storied School Building Building Portion Ic Internal Water Supply Sanitary Instal

Issued by Government Departments · tripura, Tripura
Tender Value
6.69 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
6 days left
EMD
13386
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Proposed Infrastructure Development Of Kalkalia High School At Kalkalia Under Mohanpur West Tripura Sanctioned Under Ridf Xxix Sh Construction Of New Double Storied School Building Building Portion Ic Internal Water Supply Sanitary Installations Sew

BOQ

Name of Work:-
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-
2Short Point :-
3Medium Point :-
4Long Point :-
5Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
6Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
7Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
82 X 1.5 sq mm:-
92 X 2.5 sq mm
102 X 4 sq mm
114 X 6 sq mm:-
124 X 10 sq mm:-
13Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:-
141 X 1.5 sq mm:-
151 X 2.5 sq mm:-
162 X 4 sq mm:-
172 X 6 sq mm:-
18Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.
19Supplying and fixing of the following electrical accessories i/c necessary conn. etc. as reqd.
20Ding Dong call bell
2132 amps DP kit kat switch
22Gong bell
23Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required.
24102mm x 178mm (4'' x 7'')
25300mm x 380mm (12\\" X 15\\") :-
26Supplying and fixing of the following modular accessories including necessary connection etc. as required.
275 step fan regulator (2M):-
28Blank plate (1M):-
29Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required.
30Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
31Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.
32Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required.
33Supplying & fixing of 1400 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked) : -
34Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-
35Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
36Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:
37Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-
38Bulk head fittings with frosted/clear glass suitable for GLS or retrofit CFL/LED (without lamp) : -
39Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : -
40Supplying and fixing of surface mounted 18/20 watt LED tube luminaire with powder coated finished 0.5mm thick CRCA steel sheet housing including 1 no 18/20 watt LED tube having minimum system lumen output of 120 lumens/watt & life expectancy of 50,000 burning hours with integral driver having 2kV SPD and polycarbonate diffuser including connection etc as required ( with LM79 report from NABL accrediated lab):-
41Supplying and fixing of following surface/recess mounted round/square shaped die cast Aluminium housing with white powder coated polycarbonate diffuser having minimum IP20 protection complete with electronic LED driver mounting clamp including necessary connection etc. as required (with 50000 burning hours,THD ≤10% and minimum lumen output of 100lm/watt with LM79 report from NABL accrediated lab):-
42Surface mounted round/Square shaped 12 watt LED downlight with,Internal SPD-2.5 KV.
43Supplying and fixing of following outdoor LED luminaries in powder coated Aluminium die cast housing complete with precise street Optic Lens with heat resistant tempered glass/diffuser protection with IP66 and IK10 impact resistance including necessary connection etc. as required (with 50000 burning hours, THD ≤10% and minimum lumen output of 120lm/watt with LM79 report from NABL accrediated lab):-
44100 watt LED street light fixture with integral driver and secondary lens,10kV external & 6kV internal SPD):-:-
45Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
469 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
47Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-
4832 amps 415 volts four strip Copper busbar chamber 4 ways of size (300mmx240mmx80mm):-
49Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-
5032 amps 415 volts TPN main switch (rewireable):-
51Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:-
5232 amps kitkat porcelain fuse unit with base (rewireable):-
53Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/ RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.
542 way SPN MCB DB (single door):-
55(2+6) / 8 way SPN MCB DB (double door):-
56(2+10) / 12 way SPN MCB DB (double door):-
57Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-
586 to 32 amps SP MCB:-
596 to 32 amps DP MCB:-
60Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor Un-armoured cable with necessary connection etc as required
613 core 4 Sq mm
62Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : -
631.5 sqmm - 4 sqmm Cable:-
64Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: -
654 sq mm
666 sq mm
6710 sq mm
68Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-
6940 mm dia
70Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-
71Drawing of armoured/un-armoured cable with proper saddeling etc as required:- Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56716445
AUTHORITY Government Departments
TENDER VALUE 6.69 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Proposed Infrastructure Development Of Kalkalia High School At Kalkalia Under Mohanpur West Tripura Sanctioned Under Ridf Xxix Sh Construction Of New Double Storied School Building Building Portion Ic Internal Water Supply Sanitary Installations Sew
Basic Detail
Tender No EE_IED_AGT_54_2026_27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 28 Jul 2026
Submission Date 06 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 6.69 Lakhs
Tender Fee 1000
EMD 13386
Exemption Available
Document List
0c480a6b-c774-4890-b1b5-cddfc38a487e.html
BOQ_76372.xls
form.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

0c480a6b-c774-4890-b1b5-cddfc38a487e.html

xls

BOQ_76372.xls

pdf

form.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders