Housing Urban and Rular Development Government Departments Closing in 5 days TDR #56716442

Tender For Construction Of 10(Ten) Nos Staff Quarters(Type-I-04 Units(One Block-Twin-Double Storey), Type-Ii Quarter-04 Units(One Block-Twin-Double Storey) And Type-Iii Quarter-02 Units(One-Block-Twin-Single Storey) At Natunbazar Chc, Gomati District

Issued by Government Departments · Gomati, Tripura
Tender Value
11.35 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
5 days left
EMD
22704
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gomati → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 10(Ten) Nos Staff Quarters(Type-I-04 Units(One Block-Twin-Double Storey), Type-Ii Quarter-04 Units(One Block-Twin-Double Storey) And Type-Iii Quarter-02 Units(One-Block-Twin-Single Storey) At Natunbazar Chc, Gomati District, Tripura Under Nhm/Sh: Building Portion Including Internal Water Supply, Sanitary Installation, Sewage And Drainage Works/ Sh:Providing Internal Electrification Works Thereof. (2Nd Call)

BOQ

Name of Work:- Construction of 10(ten) nos staff quarters(Type-I-04 units(one block-twin-double storey), Type-II quarter-04 units(one block-twin-double storey) and Type-III quarter-02 units(one-block-twin-single storey) at Natunbazar CHC, Gomati District, Tripura under NHM/SH: Building portion including internal water supply, sanitary installation, sewage and drainage works/ SH:Providing Internal Electrification works thereof. (2nd call)
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-
2Short Point :-
3Medium Point :-
4Long Point :-
5Wiring for 2 way controlling light point with 3 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type 2 way switch, cover plate, surface modular switch board including connection etc as required:-
6Medium Point :-
7Long Point :-
8Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
9roviding and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
10Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
112 x 1.5 sq.mm:-
122 x 2.5 sq.mm:-
132 x 4 sq.mm:-
142 x 6 sq.mm:-
15Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/ surface including connection etc. as required.
161 x 1.5 sq.mm:-
171 x 2.5 sq.mm:-
182 x 2.5 sq.mm:-
192 x 4 sq.mm:-
202 x 6 sq.mm:-
21Supplying and fixing of the following Modular accessories including necessary connection etc. as required..
22Electronic 5 step fan regurator (2M)
23Blank plate (1M):-
24Supplying and fixing of the following electrical accessories including necessary connection etc. as required.
25Musical call bell
26Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required:-
27Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
28Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required.
29Supply and fixing of 25mm x 3mm Copper strip on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals.
30Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/ 415 volts MCB/ Isolator/ RCCB (SP/ SPN/ DP/TP /TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.
312 way SPN MCB DB (single door):-
32(2+6) / 8 way SPN MCB DB (Double door):-
33(2+10) / 12 way SPN MCB DB (Double door):-
34Supplying and fixing of following ratings MCB B/C curve having breaking capacity 10 KA in the existing MCB, DB including connection as reqd.
356 to 32 amps SP MCB:-
366 to 32 amps DP MCB:-
37Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
38Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
39Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
40Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
4118/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
429 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
43Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-
44Bulk head fittings with frosted/clear glass suitable for GLS or retrofit CFL/LED (without lamp) : -
45Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : -
46Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:-
47Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
48Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:-
49Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : -
50Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-
51Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-
5260 watt LED street light fixture with integral driver and secondary lens (IP 66):-
53Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required
543 core 4 Sq.mm
554 core 6 Sq.mm
56Drawing of armoured/un-armoured cable with proper saddling etc as required:-
57Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :-
58Suppling, installation ,testing and commissioning of totally enclosed compartmentalized cubical electrical panel board double door type having size of (.40 x 0.40 x 0.30)mtr fabricated with standared MS angle (40 x40 x6)mm in size with 04 nos.70 cm long legs grouted on Base by c.c.work 2 mm thick (14 SWG) M.S. sheet painted with powder coating and necessary earth bars, din rails etc for installation of 2nos Dp MCB, switchgears, main switch and busbar chamber, well insulated etc with necessary insulators , cable etc i/c cable terminals and interconnections as required:
59Supplying and fixing of 3 phase Astronomical/Digital Street light panel of 6 KW Range, consisting of 32 A TP contactor , 40 A TPN MCB, Conforming to IS/IEC 60947-4-1 provided with Protection Degree of IP 54, Extended wide band coil, FRLS (Fire retardant low smoke) Internal wiring ,In-built Short-Circuit Protection with Class H Insulation including necessary connection etc as required.
60Supplying and fixing of 7 mtr long OCTAGONAL POLES with withstanding capacity of 180 kmph wind speed i/c necessary connection etc as required:-
61Supplying and fixing of arms for installation of street lamps in existing Octagonal pole i/c necessary connection etc as required:-
62Single arm
63Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):-
64Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank:-
656 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ):-
66Neat cement punning:-
67Supplying and fixing of following accessories of switchgears including connection as required.
6832 amps rewireable(kitkat) porcelain fuse unit with base
69Supplying and installation of industrial plug & socket complete with metal enclosure including necessary connection etc. as required of the following ratings (without MCB):-
7020 amps 230/240 volts single phase suitable for SP/SPN/DP MCB:-
71Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required.
72254mm x 300mm (10\\" X 12\\") :- Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56716442
AUTHORITY Government Departments
TENDER VALUE 11.35 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of 10(Ten) Nos Staff Quarters(Type-I-04 Units(One Block-Twin-Double Storey), Type-Ii Quarter-04 Units(One Block-Twin-Double Storey) And Type-Iii Quarter-02 Units(One-Block-Twin-Single Storey) At Natunbazar Chc, Gomati District, Tripura Under Nhm/Sh: Building Portion Including Internal Water Supply, Sanitary Installation, Sewage And Drainage Works/ Sh:Providing Internal Electrification Works Thereof. (2Nd Call)
Basic Detail
Tender No EE-IED/UDP/06/2026-27
Bidding Type Tender
Location
City Gomati
State Tripura
Key Dates
Publish Date 28 Jul 2026
Submission Date 05 Aug 2026
Open Date 05 Aug 2026
Finance
Tender Value 11.35 Lakhs
Tender Fee 1000
EMD 22704
Exemption Not Available
Document List
252270da-e27e-4703-bd8d-d66cbff5a554.html
BOQ_76366.xls
EDNIT.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

252270da-e27e-4703-bd8d-d66cbff5a554.html

xls

BOQ_76366.xls

pdf

EDNIT.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail