Tender For Work Of Supply, Erection, Transmission And Commissioning Of One 200Kva Distribution Transformer Centre Under System Improvement Scheme, At Ambexir, Benaulim Under Sub-Division I, Benaulim, Division Xvi Margao
Tender Value
36.96 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
16 days left
EMD
73931
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Work Of Supply, Erection, Transmission And Commissioning Of One 200Kva Distribution Transformer Centre Under System Improvement Scheme, At Ambexir, Benaulim Under Sub-Division I, Benaulim, Division Xvi Margao
BOQ
| Sl. No. | Item Description |
| 1 | COST OF MATERIAL |
| 2 | Supply of XLPE cable armoured 3C X 300 sq.mm 11 KV Grade (Double Run) |
| 3 | Supply of XLPE cable armoured 3C X 95 sq.mm 11 KV Grade |
| 4 | Supply of XLPE cable unarmoured 1C X 300 sq.mm 1.1 KV Grade |
| 5 | Supply of XLPE cable armoured 3 ½ C X 185 sq.mm 1.1 KV Grade |
| 6 | Supply of H.S 11K V Straight through joint 3 core, 300 SQMM |
| 7 | Supply of H.S.11 KV Termination kit indoor 300 XLPE 3 core |
| 8 | Supply of H.S.11 KV Termination kit outdoor 95 XLPE 3 core |
| 9 | Supply of H.S.11 KV Termination kit Indoor 95 XLPE 3 core |
| 10 | 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB, Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. |
| 11 | LV Main Switch board for 200KVA Transformer centre-Outdoor |
| 12 | Supply of Loss Level-II 200KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer |
| 13 | Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith Batonite complete with brick masonary. |
| 14 | FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6 |
| 15 | Supply of GI Flat 25 x 5 mm. |
| 16 | Supply of RCC Cable route Marker |
| 17 | Supply of Lugs 300 sqmm |
| 18 | Supply of Lugs 185 sqmm |
| 19 | Supply and filling of sand in plinth under floors , trenches including waterin ,ramming consolidating ,dressing complete. |
| 20 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size)excluding cos t of centering and shuttering and finishing for foundations.ALL WORKS UPTO PLINTH LEVEL |
| 21 | Providing Centering and shuttering including struttings, propping etc and removal of formwork |
| 22 | Supply and Providing of 12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. |
| 23 | Brick work using common burnt building bricks in cement mortar 1:4 (1 cement : 4 coarse sand) with bricks of class designation 75 kgs/ cm2 (wire cut bricks) |
| 24 | Supply & laying of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semidry concrete that is batched in a fully automatic PLC controlled concrete batching plant & cast in a fully automatic \\"Vibro-Press\\" machine with a high vibration frequency and hydraulic pressure of 40MT, the size of the slab shall be 480mmX250mmX50mm, (+/- 2mm) & the concrete grade shall be M30 adhering to IS 456:2000 & shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested. |
| 25 | Laterite Masonary Works: Rubble packing with hard laterite stone under floors including watering, ramming & consolidating etc. in pipeline trenches and other foundations complete for double circuit 11KV cable trench (0.2x0.9x1.00) i.e. 0.18 per RM |
| 26 | Supply of Common Automatic Meter Reading (CAMR) Modems |
| 27 | Warning Tape |
| 28 | Supply of MS Distribution box complete.M. S. distribution box as per drawing No.CEE/E-689 Revision No.3 alongwith MCCB of 400Amps & 12 nos. of 200 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals conforming in general to drawing No.EE-II/7/2002 |
| 29 | COST OF ERECTION |
| 30 | Erection of XLPE cable armoured 3C X 300 sq.mm 11 KV Grade (Double Run) |
| 31 | Erection of XLPE cable armoured 3C X 95 sq.mm 11 KV Grade |
| 32 | Erection of XLPE cable unarmoured 1C X 300 sq.mm 1.1 KV Grade |
| 33 | Erection of XLPE cable armoured 3 ½ C X 185 sq.mm 1.1 KV Grade |
| 34 | Erection of H.S 11K V Straight through joint 3 core, 300 SQMM |
| 35 | Erection of H.S.11 KV Termination kit indoor 300 XLPE 3 core |
| 36 | Erection of H.S.11 KV Termination kit outdoor 95 XLPE 3 core |
| 37 | Erection of H.S.11 KV Termination kit Indoor 95 XLPE 3 core |
| 38 | 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB, Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. |
| 39 | LV Main Switch board for 200KVA Transformer centre-Outdoor |
| 40 | Erection, testing and commissioning of Loss Level-II 200KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer |
| 41 | Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith Batonite complete with brick masonary. |
| 42 | FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6 |
| 43 | Erection of GI Flat 25 x 5 mm. |
| 44 | Erection of RCC Cable route Marker |
| 45 | Crimping of Lugs 300 sqmm |
| 46 | Crimping of Lugs 185 sqmm |
| 47 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in |
| 48 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 49 | Disposal of exavated soil |
| 50 | Supply & laying of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semidry concrete that is batched in a fully automatic PLC controlled concrete batching plant & cast in a fully automatic \\"Vibro-Press\\" machine with a high vibration frequency and hydraulic pressure of 40MT, the size of the slab shall be 480mmX250mmX50mm, (+/- 2mm) & the concrete grade shall be M30 adhering to IS 456:2000 & shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested. |
| 51 | Erection of MS Distribution box complete.M. S. distribution box as per drawing No.CEE/E-689 Revision No.3 alongwith MCCB of 400Amps & 12 nos. of 200 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals conforming in general to drawing No.EE-II/7/2002 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender