Public Administrative Department Local Bodies Closing in 20 days TDR #56715586

Tender For Construction Of Ohrs With Geotechnical Investigation & Design Of Sub-Structure, Boundary Wall, Guard Room, Land Development, Approach Road, Masonary Drain, Supplying & Laying Of Distribution Pipe Lines (Di-K7 And Hdpe) With Temporary Road

Issued by Local Bodies · Murshidabad, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Aug 2026
20 days left
EMD
10 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Murshidabad → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Ohrs With Geotechnical Investigation & Design Of Sub-Structure, Boundary Wall, Guard Room, Land Development, Approach Road, Masonary Drain, Supplying & Laying Of Distribution Pipe Lines (Di-K7 And Hdpe) With Temporary Road Restoration For Vehicular Movement And All Other Allied Works Complete In All Respect Within Different Zones At Dhuliyan Municipality Under Amrut 2.0

BOQ

Name of Work:- Construction of OHRs with Geotechnical investigation & Design of sub-structure, Boundary wall, Guard Room, Land Development, Approach Road, Masonary Drain, Supplying & laying of Distribution pipe lines (DI-K7 and HDPE) with temporary road restoration for vehicular movement and all other allied works complete in all respect within different zones at Dhuliyan Municipality under AMRUT 2.0
Sl. No. Item Description
1Geo-Technical investigation, Design & drawing (Sub-structure part) & Construction of RCC Elevated Over Head Reservoir (Intze type) of capacity 1600 cum of staging height 20 meter with pile foundation including pipe connection for head works, Guard Room with sanitary arrangement, Land Development, Approach Road, Boundary Wall with Gate & Masonry drain, Internal electrification & yard lighting at premises as per Departmental design, drawing & specification etc. Including supply of all materials as required complete in all respect at Zone-I in ward no.20 of Dhuliyan Municipality
2Geo-Technical investigation, Detailed Design and drawing & Construction of Pile foundation (Minimum Grade M25 including cost of reinforcement works as per approved drawing) & direction of EIC.
3Construction & commissiong of Super structure of OHR including construction of Pile cap & Performing Vertical load test on single Pile (1 no) in accordance with IS:2911(Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete of required strength for receiving the Testing load up to 100 T, along with other ancilliary works ;Guard Room with sanitary arrangement,Approach road,Boundary Wall with gate,Land developemnt ,Drainage work, Internal ilumination & yard lighting site clearance etc. complete in all respect as per departmental drawing , specification & direction of EIC
4Geo-Technical investigation, Design & drawing (Sub-structure part) & Construction of RCC Elevated Over Head Reservoir (Intze type) of capacity 1150 cum of staging height 20 meter with pile foundation including pipe connection for head works, Guard Room with sanitary arrangement, Land Development, Approach Road, Boundary Wall with Gate & Masonry drain, Internal electrification & yard lighting at premises as per Departmental design, drawing & specification etc. Including supply of all materials as required complete in all respect at ZoneVIII in ward no.16 of Dhuliyan Municipality
5Geo-Technical investigation, Detailed Design and drawing & Construction of Pile foundation (Minimum Grade M25 including cost of reinforcement works as per approved drawing) & direction of EIC.
6Construction & commissiong of Super structure of OHR including construction of Pile cap & Performing Vertical load test on single Pile (1 no) in accordance with IS:2911(Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete of required strength for receiving the Testing load up to 100 T, along with other ancilliary works ;Guard Room with sanitary arrangement,Approach road,Boundary Wall with gate,Land developemnt ,Drainage work, Internal ilumination & yard lighting site clearance etc. complete in all respect as per departmental drawing , specification & direction of EIC
7Geo-Technical investigation, Design & drawing (Sub-structure part) & Construction of RCC Elevated Over Head Reservoir (Intze type) of capacity 1150 cum of staging height 20 meter with pile foundation including pipe connection for head works, Guard Room with sanitary arrangement, Land Development, Approach Road, Boundary Wall with Gate & Masonry drain, Internal electrification & yard lighting at premises as per Departmental design, drawing & specification etc. Including supply of all materials as required complete in all respect at Zone IX in ward no.16 of Dhuliyan Municipality
8Geo-Technical investigation, Detailed Design and drawing & Construction of Pile foundation (Minimum Grade M25 including cost of reinforcement works as per approved drawing) & direction of EIC.
9Construction & commissiong of Super structure of OHR including construction of Pile cap & Performing Vertical load test on single Pile (1 no) in accordance with IS:2911(Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete of required strength for receiving the Testing load up to 100 T, along with other ancilliary works ;Guard Room with sanitary arrangement,Approach road,Boundary Wall with gate,Land developemnt ,Drainage work, Internal ilumination & yard lighting site clearance etc. complete in all respect as per departmental drawing , specification & direction of EIC
10Supply & Laying DI (K7) & HDPE pipe (Materials grade PE-100, PN-6)/ D.I (K7)/MS pipe including supplying & laying with Specials & Connection with existing Pipe in distribution, carriage of materials to work site carefully(including loading-unloading) in trenches maintaining proper levels and alingment including earth work in excavation in trenches, shoring (if necessary) of adequate width having minimum depth to keep the top surface of pipe 1.1 m below of the existing ground level in any kind of soil mixed with boulder, metal crust, concrete pavement, any road sub-grade and its flank etc., dewatering the trenches, preparing the bottom surface of the trenches for continuous bedding including sand filling (if necessary) and fitting, fixing, jointing (all types of joints) valves, specials etc. as per requirement, in position, cutting, chamfering of pipes as required,including supply of EPDM Rubber gasket, polythene sleeves, Nuts & Bolts (TATA /GKW make) & other materials as per site condition, filling of the trenches with excavated materials, consolidating the same in layers, guarding trenches with temporary bamboo railing for safety where necessary, emergency horizontal auger boring (HDD Method ) for SH/PWD roads other than NH & Railway where necessary, temporary road restoration for vehicular movement, removing the surplus materials from site including all labour charges, tools and plants, hydraulic pressure testing, cleaning and disinfection of pipes etc. complete in all respect as per IS 12288-1987 (latest edition) and instruction of E.I.C. including submission of 6 sets of completion drawings (In case of damage of any kind of cable line during excavation, necessary damage charges as applicable by the respective authority will be borne by the agency in his own cost.) (As detailed in the Scope of Work of eNIT) (For Zone1 to 9)
11HDPE Pipe Line: 110 mm dia.
12HDPE Pipe Line: 160mm dia.
13DI (K/7) Pipe Line: 100 mm dia.
14DI (K/7) Pipe Line: 150 mm dia.
15DI (K/7) Pipe Line: 200 mm dia.
16DI (K/7) Pipe Line: 250 mm dia.
17DI (K/7) Pipe Line: 300 mm dia.
18DI (K/7) Pipe Line: 350 mm dia.
19DI (K/7) Pipe Line: 400 mm dia.
20MS Pipe Line: 100mm dia.
21MS Pipe Line: 150mm dia.
22MS Pipe Line: 200mm dia.
23MS Pipe Line: 250mm dia.
24MS Pipe Line: 300mm dia.
25MS Pipe Line: 350mm dia.
26MS Pipe Line: 400mm dia.
27Cast iron double flanged manually operated sluice valves generally conforming to IS 14846 : 2000, having four faces and spindle nut of gunmetal. inside screw non- rising type quality gunmetal /AISI 410 spindle: seat tested to 10kg/CM² and body tested to 15kg/CM², flanges flat faced and drilled to 1.S.: 1538 : 1993. Painted black all over with asphalt base paint. Valves tested by closed end method. (In Distribution Pipe Line )
28100mm dia
29150mm dia
30200 mm dia
31250mm dia
32300mm dia
33350mm dia
34400mm dia
35Cast iron kinetic double orifice type air release valve having small orifice elasticball resting on gunmeta lorifice nipple large orifice vulcaniteball seating on moduled seat ring, valve with built-in-Kinetic features, isolating sluice valve mounted in horizontal position and operated by ametre wheel gearing:inlet faced and drilled to IS1538Table4&6.valve suitable for maximum working pressure of 10 kg/CM2 (In Distribution pipe line)
36Air Release Valve 80 mm dia.
37Air Release Valve 100 mm dia.
38Air Release Valve 150 mm dia.
39Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] (In Distribution pipe Line)
4080 mm to 150 mm dia pipe
41200mm dia
42250mm to 350mm dia
43400mm dia to 450mm dia Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56715586
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 21-08-2026
Authority
Authority Name Municipal Affairs Department
Work Description Tender for Construction Of Ohrs With Geotechnical Investigation & Design Of Sub-Structure, Boundary Wall, Guard Room, Land Development, Approach Road, Masonary Drain, Supplying & Laying Of Distribution Pipe Lines (Di-K7 And Hdpe) With Temporary Road Restoration For Vehicular Movement And All Other Allied Works Complete In All Respect Within Different Zones At Dhuliyan Municipality Under Amrut 2.0
Basic Detail
Tender No WBMAD/eNIT-05 of SE(E)/2026-27
Bidding Type Tender
Location
City Murshidabad
State West Bengal
Key Dates
Publish Date 28 Jul 2026
Submission Date 21 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 10 Lakhs
Exemption Available
Document List
31bdf771-1878-4a5c-9302-401c43d8ae99.html
BOQ_5087785.xls
Tendernotice_1 (16).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

31bdf771-1878-4a5c-9302-401c43d8ae99.html

xls

BOQ_5087785.xls

pdf

Tendernotice_1 (16).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders