Tender For Conservation Of Water Bodies Under Rohini Zone.Sub Head:- Providing & Replacement,Installation,Testing & Commissioning Of Semi-High Mast Poles,Path Lighting & Gate Lights In 12 Nos. Water Bodies In Rohini Zone.
Tender Overview
Project Description
Tender for Conservation Of Water Bodies Under Rohini Zone.Sub Head:- Providing & Replacement,Installation,Testing & Commissioning Of Semi-High Mast Poles,Path Lighting & Gate Lights In 12 Nos. Water Bodies In Rohini Zone.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, installation, testing and commissioning of hot dip galvanized octagonal steel pole of 9 Mtr. height and made of 3 mm thick sheet, having bottom 155 mm OAF & top 70 mm OAF, hot dip galvanized M.S base plate of size 260 mm x 260 mm x 16 mm thick, on existing RCC foundation with GI bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc.,GI Sleeve on connector box made out of 3mm thick MS sheet 250 mm wide duly welded with existing connector box cover of pole complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box having flush cover with 2 nos mounting strips with tapped holes:- (a) 6 mm thick phenolic laminated / bakelite sheet inside the window mounted on the existing mounting strips inside the flush door. (b) 4 nos. 40 Amp terminal block suitable for following conductor / cable, fixed on DIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / bakelite sheet. (i) 16 sq mm conductor – 4 nos and short links 5-nos. (ii)Terminal suitable for 6 SWG GI wire / 1.5 sq mm wire. (c) 6 Amp SP MCB,10 kA ‘C’ Series-1 nos. including mountings on DIN channel, Earth stud 2 Nos. welded at suitable height i/c washers, springs washers & nuts etc. (d) Suitable arrangement for saddling of incoming / outgoing cables i/c lugs thimbles etc as required. |
| 2 | Providing and laying in position, M25 reinforced cement concrete foundation of size 500mm long x 500mm wide and 1400 mm deep i/c excavation of earth, refilling, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1500 mm long (approx.)-8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia. 2000 mm long (approx.)-8 Nos. (With approx. 150 mm spacing) i/c centering & shuttering as required, positioning of foundation bolts 4 nos. M-24x750mm long foundation bolt of L Type (100 mm bend & 750 mm straight), 150 mm top threaded portion of bolt shall be galvanized and rest portion shall be coated with Red oxide to avoid corrosion & G.I nuts (EN 8-grade) with 3 Nos. and 2 Nos. washer, along with 2 Nos. templates/Anchor plate of size 260 mm x 260 mm x 3 mm thick shall be supplied manufactured from the original pole manufacturing company only for casting of foundations and providing 63 mm (OD) 2 Nos. DWC pipe 1 mtr long approx. each for cable entry and exit etc complete as required. |
| 3 | Supplying and installation of hot dip galvanized circular ring having inner diameter 1000 mm made out of 48 mm dia MS pipe B-class and having 4 nos. arms of length approximate 400mm long each made out of 40mm dia MS pipe B- class i/c mounting arrangement at the top of the pole i/c marking holes for installation of flood light luminaries and wire entries with movable cap at the top with fixing arrangement. Complete as required. |
| 4 | 100 W LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15,lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg, suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 5 | Rate as per quotation of M/s RISHA Dated 07.08.2025Supplying, installation, testing and commissioning of floor mounted feeder panel duly compartmentalized (outdoor type) double door cubicle panel board of Suitable size made out of 2mm thick CRCA MS sheet having hinged gasketed cover and screw type knob with double locking arrangement and rain protection cover mounted on MS angle iron base frame made out of 40 mm X 40 mm X 5 mm angle iron with 1 mtr. Long leg grouted with 1:3:6 foundation and should be as per drawing approved by Engineer-In-Charge. Legs should be covered with brick wall, connection, interconnection with painting after applying a coat of primer, i/c connection inter connection of the accessories mounted there on with suitable size of copper wire with thimble/lugs, earthing the body of the feeder panel i/c supplying & fixing of the following items : INCOMER a) 63A 4 pole 25 kA MCCB - 1 Nob) Ammeter with selector switch (0-25 A) - 1 Noc) Voltmeter with selector switch (0-500 V) - 1 No d) Indication Lamp (RYB) with control HRC fuse with fuse fitting- 1 set. BUS BAR 100 A TPN Al. Bus Bar (suitable size) - 1 SetOUTGOING a) 16 A TP&N 10 kA MCB - 4 Nos.b) Power contactor - 1 No.c) Astronomical Timer switch – 1 No.d) Auto/Manual toggle switch – 1 No. e) Compartment having space for DISCOM energy meter with 6mm thick Bakelite sheet for mounting energy meter.f) Danger Notice plate – 1 No.g) Lightning inside the feeder pillarNote: Foundation dully plastered and finished shall be made as per site requirement for which nothing extra shall be paid. |
| 6 | Supplying fabrication and installation of wire mesh protection cover guard for main feeder pillar made out of 8 SWG wire mesh of suitable size with MS angle iron base frame 40 mm X 40 mm X 5 mm and 0.5 Mtr. long leg spot and MS strip with support size 40 mm X 6 mm as per drawing approved by Engineer-in-Charge i/c providing door of suitable size with S/F of godown lock, locking arrangement, painting and grouting of angle iron frame in CC 1:2:4 etc. complete as required. |
| 7 | Supplying,installation,testing & commissioning of 4Mtr. high decorative pole (as per indicative drawaing or as approved by the engineer-in-charge)made out of GI tube B-class pipe with duly welded with MS base plate of dia 250 mm X 250 mm X 10 mm, a different section bottom 1000 mm X 114 mm X 4.0 mm & upper section 3000 mmX 76 mm X 3.2 mm with cast aluminum embellishment E3 and has a service window with connector and SPMCB for loop-in & loop-out arrangement. The pole will be primer coated and PU painted to accomodate ornamental LED post top fixture etc. complete as required . |
| 8 | Casting and erection of suitable foundation for pole of overall size 400 mm x 400 mm x1200 mm deep (both above & below ground level), having concrete mix 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) including fixing of \\"J' type MS bolts - 4 Nos, Two nos. DWC pipes of 32/40mm dia, medium class, of suitable lenght shall be embedded in above foundation for drawing of incoming and ougoing cable. The tor steel used in pedestal shall be 12mm dia 8 nos. vertical with 10mm dia ring for @200 c/c as binders - 7 No. complete with digging, shuttering & back filling etc. as required. Tor steel shall be ISI marked. |
| 9 | Supplying and fixing 40 wattage LED post-top lantern with spun aluminium canopy and die-cast aluminium spiget with clear acrylic diffuser made up of aluminium housing with dif-fuser i/c fasteners/G.I. piping,connections,testing & commissioning etc. complete as required. |
| 10 | Supply & Fixing of anti climbing device on existing ornamental Poles of 76 mm dia and upto 4.5 mtr. height made out of stainless steel. Clamp of strip size 30mmx5mm and 10 mm steel roads 30 cm each fixed at 30 degree in circular shape i/c nut , bolts, painting etc. complete etc. as reqd. |
| 11 | Supplying of following sizes of PVC insulated and PVC sheathed/XLPE aluminium conductor armoured power cable of 1.1 KV grade i/c connection & testing etc. as required and as per technical specification enclosed. |
| 12 | 4 x 16 Sq.mm |
| 13 | 4 x 25 Sq.mm |
| 14 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 15 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 16 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 17 | Laying of one number PVC insulated and PVC sheeted/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/Metal/DWC pipe / pole as required. |
| 18 | Up to 35 Sq.mm |
| 19 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in recessed steel/ PVC conduit as required. the existing surface |
| 20 | 3 x 1.5 sq. mm |
| 21 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. |
| 22 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 23 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 24 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface /recessed conduit submain wiring /cable as required. |
| 25 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 26 | 25 mm |
| 27 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 28 | Single pole |
| 29 | Double pole |
| 30 | Supplying and fixing 36 wattage LED post-top lantern with spun aluminium canopy and die-cast aluminium spiget with clear acrylic diffuser made up of aluminium housing with dif-fuser i/c fasteners/G.I. piping,connections,testing & commissioning etc. complete as required.[SLE PT 36W ETPP of M/s Surya or equivalent or superior make] |
| 31 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 32 | 4x16 sq.mm |
| 33 | 4x25 sq.mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender