Tender For Supply And Fixing Of Level Measuring System And Flow Meter In Kumbakonam City Municipal Corporation.
Tender Value
29.55 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
19 days left
EMD
29550
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thanjavur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply And Fixing Of Level Measuring System And Flow Meter In Kumbakonam City Municipal Corporation.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, delivery and installation of water level measuring system up to 1 mm accuracy to measure up to 30 m depth in wells/OHTs/ sumps with suitable sensor, level transducer with transmitter, 2 or 4 wire loop, all wetted parts in SS304 or above and with Remote control and suitable LED display unit easily readable upto 10m distance, cabinet to house remote display unit, Low/High alarm with suitable speaker, suitable cables with data storage capacity for 1 year and data transfer facility and with all required accessories including 1 year free replacement warranty etc., complete. |
| 2 | D.I Specials required for flow meter |
| 3 | SOCKET-200mm |
| 4 | SOCKET-300mm |
| 5 | SOCKET-450mm |
| 6 | Flange - 200mm |
| 7 | Flange - 300mm |
| 8 | Flange - 450mm |
| 9 | Jointing C.I/ D.I double flanged pipes and specials with rubber insertion or any equivalent to the required specifications with M.S. bolts and nuts etc., complete including charges for special tools and plants such as air compressor and helmets and sheet piles. etc (including cost of jointing materials) |
| 10 | 200mm dia C.I/ D.I-S/S Pipes andSpecials |
| 11 | 300mm dia C.I/ D.I-S/S Pipes andSpecials |
| 12 | 450mm dia C.I/ D.I-S/S Pipes andSpecials |
| 13 | Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accridiated lab to be furnished. |
| 14 | 300mm Diameter |
| 15 | 200mm Diameter |
| 16 | 450mm Diameter Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender