Tender For Repair Of Roof, Sunken Floor, False Ceiling, Joinery, Flooring, Periodical Services And Other B/R Works Of Restricted And Unrestricted Area Of 506 Abw Under Age B/R-Ii Of Ge (East) Jabalpur
Tender Value
48 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
12 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Of Roof, Sunken Floor, False Ceiling, Joinery, Flooring, Periodical Services And Other B/R Works Of Restricted And Unrestricted Area Of 506 Abw Under Age B/R-Ii Of Ge (East) Jabalpur
BOQ
| Sl. No. | Item Description |
| 1 | RESTRICTED AREA |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed. |
| 3 | M&L for Non Skid coloured ceramic tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over & including 15 mm thick screed bed or bedding layer of 1:6 cement mortar for laying floor finishes complete all as specified and directed. |
| 4 | M&L for Non Skid coloured ceramic tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over & including 15 mm thick screed bed or bedding layer of 1:6 cement mortar for laying floor finishes complete all as specified and directed. |
| 5 | M&L for Glazed coloured ceramic tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick in vertical surface such as dado / skirting / risers to steps etc., set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including rendering 10 mm thick in cement mortar 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. |
| 6 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed. |
| 7 | M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in :6 cement mortar complete all as specified & directed. |
| 8 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in 1:4 cement mortar complete all as specified and directed. |
| 9 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 10 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:6 and to be finished even and smooth (without using extra cement) complete all as specified and directed. (height upto 12.50m) |
| 11 | M&L for rendering 5 mm thick in cement mortar 1:3 on RCC/ceiling surface and finished even and smooth (without using extra cement) complete all as specified and directed . (height upto 12.50m) |
| 12 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:4 and to be finished even and smooth (without using extra cement) complete all as specified and directed. (WPC measured and paid seperately) (height upto 12.50m) |
| 13 | M&L for preparation of newly plastered brick work or concrete surfaces & applying three coats of white wash on prepared brick work or concrete surfaces complete all as specified and directed. |
| 14 | M&L for preparation of newly plastered brick work or concrete surfaces & applying two coats of cement based paint over & including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. |
| 15 | M&L for preparation of newly plastered brick work or concrete surfaces & applying two coats of oil bound distemper over & including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. |
| 16 | M&L for preparation of newly plastered surfaces of ceiling and apply three coats of white wash on prepared ceiling surface.Complete all as specified and directed. |
| 17 | M&L for complete removal of existing treatment on brick work or concrete surfaces & applying 2 mm thick Wall Care Putty on brick work or concrete surfaces complete all as specified and directed . |
| 18 | M&L for applying two coat of oil bound distemper on brick work or concrete surfaces or plastered surface over & including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. |
| 19 | M&L for preparation of old painted brick work or concrete surfaces or plastered surface & applying one coat of white wash on brick work or concrete surfaces complete all as specified and directed. |
| 20 | M&L for preparation of old painted brick work or concrete surfaces & applying one coat of cement based paint on brick work or concrete surfaces complete all as specified and directed. |
| 21 | M&L for preparation of old painted brick work or concrete surfaces o plastered surface & applying one coat of oil bound distemper on brick work or concrete surfaces complete all as specified and directed. |
| 22 | M&L for preparation of old painted ceiling surfaces & applying one coat of white wash on ceiling surfaces complete all as specified and directed. |
| 23 | M&L for preparation of old painted Steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of Synthetic enamel paint (ordinary tint) complete all as specified and directed. |
| 24 | Taking down of old existing water proofing treatment on roof surface (Horizontal & Vertical surfaces), including properly cleaning & drying the concrete surfaces complete all as specified and directed. |
| 25 | M&L for Water Proofing Treatment on \\"Non Approachable/Non Accessible and Approachable Roof\\" surfaces (Horizontal & Vertical surfaces) in following sequence through manufacturer/authorized applicator of the manufacturer complete all as specified and directed. |
| 26 | M&L for rendering 10 mm thick in cement mortar 1:4 on roof or concrete surfaces complete all as specified and directed. |
| 27 | M&L for applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg per Sqm complete all as specified and directed. |
| 28 | M&L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg per Sqm including cleaning surfaces. |
| 29 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3 mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on bitumen coated surface with 100 mm overlaps shall be sealed by flame as per manufacturer's instruction complete all as specified and directed. |
| 30 | M&L for preparation of new or previously untreated APP based polymeric membrane surfaces & applying two coats of bituminous based Aluminium Paint complete all as specified and directed. |
| 31 | S&F in repair 15mm bore bib tap fancy type chromium plate alloy with a crutch or butterfly handle screwed down for iron pipes or for brass ferrule all as specified and directed. |
| 32 | S&F in repair 15mm bore pillar taps chromium plate alloy fancy type chromium plated screwed down high pressure with or without lattered HOT or COLD with long screwed shanks and fly nuts screwed for iron pipes, att as specified and directed. |
| 33 | M&L for providing Cement Concrete Type B-1, 1:2:4 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets & railings upto 60 cm in height, copings, roof padding, sunken slab, benching, kneelers, apex stones, bed plates, kerbs, water troughs & the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 34 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all specified and directed. |
| 35 | Removing surplus demolished material to a distance exceeding 250 m but not exceeding 500 metre & depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 36 | Supply only liquid water proofing compound ISI marked complete all as specified & as directed. |
| 37 | M&L for cement concrete type C-2, 1:3:6 (using 40 mm graded brick coarse aggregate) as in sub abse,sunken floors, filling & mass concrete complete all as specified and directed. |
| 38 | S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), minimum triple layer, 500 litre capacity, hoisted and fixed in position all as specified in SSR Part-I, including dismantling of old u/s water storage tank complete all as specified and directed. |
| 39 | S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), minimum triple layer, 1000 litre capacity, hoisted and fixed in position all as specified in SSR Part-I, including dismantling of old u/s water storage tank complete all as specified and directed. |
| 40 | S&F ball valves for 20 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed. (Minimum weight 210 gms) complete all as specified and directed. |
| 41 | S&F ball valves for 25 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed. (Minimum weight 455 gms) complete all as specified and directed. |
| 42 | S&F in repair ball valves for 20 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed (Minimum weight 210 gms) complete all as specified and directed. |
| 43 | S&F in repair ball valves for 25 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed (Minimum weight 455 gms) complete all as specified and directed. |
| 44 | S&F in repair PVC tank cover for Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 or 1000 litre capacity fixed in position with nuts and bolt complete all as specified and directed. |
| 45 | S&F in repair Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed in 15 mm bore dia of pipe complete all as specified and directed. |
| 46 | S&F in repair Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed in 20 mm bore dia of pipe complete all as specified and directed. |
| 47 | Taking up or down 15 mm bore of pipe steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 48 | Taking up or down 20 mm bore of pipe steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 49 | S&F 15 mm bore GI tubes, 'medium grade' galvanised, with all fittings fixed complete to walls or ceilings or laid in floors complete all as specified and directed. |
| 50 | S&F 20 mm bore GI tubes, 'medium grade' galvanised, with all fittings fixed complete to walls or ceilings or laid in floors complete all as specified and directed. |
| 51 | Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) of 15 mm bore of pipe complete all as specified and directed. |
| 52 | Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) of 20 mm bore of pipe complete all as specified and directed. |
| 53 | M&L for Cleaning and removing all scale and dirt, etc., from RCC/PVC tanks exc 250 ltr & not exc 500 ltr capacity & from mouths of circulating pipes, etc. including washing of water tank with the use of Tank cleaning motor jet pressure machine and using bleaching powder & writing date of cleaning with any type of paint including Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 54 | M&L for Cleaning and removing all scale and dirt, etc., from RCC/PVC tanks exc 500 ltr & not exc 1000 ltr capacity & from mouths of circulating pipes, etc. including washing of water tank with the use of Tank cleaning motor jet pressure machine and using bleaching powder & writing date of cleaning with any type of paint including Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 55 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 56 | S&F G.I. powder coated snap grid frame work for false ceiling to be interlocked in such a way that the size of grid shall be 605 mm x 605 mm including 6 mm dia G.I. hangers (upto 1200 mm length) adjusting level fixed to roof by means of ceiling cleats made out of G.I. flat 40 mm x 3 mm, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long & 4 mm thick Non asbestos fibre board (E-board or V-board) designer tiles (Electra) suitably fixed in false ceiling grid/frame with staples or screws.Complete all as specified and directed.( Height of Bldg upto 9mtr) |
| 57 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 58 | Dismantling of AC Corrugated or semi corrugated sheet etc any thickness including ridges as in roof covering and stacking at site where directed and removal of debris to a outside MOD land and depositing where directed complete all as directed.(Height of Bldg upto 12.50mtr) |
| 59 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.( Height of Bldg upto 12.50mtr) |
| 60 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. ( Height of Bldg upto 12.50mtr) |
| 61 | S&F Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip & straight flashings (length & girth as fixed) with grade of zinc coating 275 of 1.00mm thick. ( Height of Bldg upto 12.50mtr) |
| 62 | S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates coforming to GDE Fe410-0 or Fe 310-O complete all as specified and directed. |
| 63 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc coforming to GDE Fe410-0 or Fe 310-O complete all as specified and directed.( Height of Bldg upto 12.50mtr) |
| 64 | S&F MS steel flat iron as in wind tie for roof sheet including securing bolts complete all as specified and directed. |
| 65 | M&L for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concretean d screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and conforming to Fe-290 Gde E-165 all as specified and directed. |
| 66 | M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, hand rails, cupboards frame and similar work con- forming to Fe.290.Gde-E-165 with and including necessary cutting and welding complete all as specified and directed.( Height of Bldg upto 12.50mtr) |
| 67 | M & L Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured 'Structural Steel') complete all as specified and directed. ( Height of Bldg upto 12.50mtr) |
| 68 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described & applying two coat of synthetic enamel paint (ordinary tint) over & including one coat of red oxide, zinc chrome primer complete all as specified and directed. |
| 69 | Taking down chowkats or frames n exc1.5 sqm with shutter incl iron monger etc (without taking off shutters from the frames). |
| 70 | Taking down chowkats or frames exc 1.50sqm but n exc 4 sqm with shutter incl iron monger etc (without taking off shutters from the frames). |
| 71 | S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 72 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate & natural fibers (wood powder/rice husk/wheat husk) & non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement & screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/sqmm, modules of elasticity 900 N/sqmm & resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant & fixed in position with MS hold fast/lugs/SS dash fasteners of required dia & length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or SS dash fasteners shall be paid for separately). Note : For WPC solid door/window frames, minus 5 mm tolerance in dimension i.e., depth & width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 73 | S & F in repair Factory made single extruded WPC (Wood Polymer Composite) solid door frame of size 125 x 65mm comprising of virgin PVC polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibre (wood powder/rice husk/wheat husk) and non tixic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC slovent cement and screwed with full body threaded star headed SS screws havng minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N (face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticty 900 N/mm2 and resistance to spread of flame of Casss A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed (M.S hold fast/lugs or SS dash fasteners shall be paid for seperately. Note : For WPC solid door minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 74 | S & F in repair Factory made single extruded WPC (Wood Polymer Composite) solid plain skeleton door shutter of 30 mm thick comprising of virgin polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibre (wood powder/rice husk/wheat husk) and non tixic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/cum and screw withdrawal strength of 1800 N (face) & 900 N (Edge), minimum compressive strength of 50 N/mm2, modules of elasticty 850 N/mm2 and resistance to spread of flame of Casss A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessay full body threaded star headed counter sunk S.S screws including and tainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples beads complete all as specified and directed. Note : Stainless steel butt hinges and necessary S.S screws shall be paid separately. |
| 75 | Providing & Fixing Factory made single extruded WPC (Wood Polymer Composite) solid flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate & natural fibers (wood powder/rice husk/wheat husk) & non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum & screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/sqmm, modulus of elasticity 850 N/sqmm & resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter & fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as per direction of Engineer-in-Charge. Note : Stainless Steel butt hinges & necessary S.S screws shall be paid separately. |
| 76 | S&F mild steel flat iron as in bands, straps, supports or stays for rain water, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 77 | Providing and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3 mm (+- 0.2 mm). Window profile with hollow section with multi chamber. Frame (88 mm x 52 mm), sliding sash (42 mm x 67 mm). Sliding mesh Sash (42 mm x 57 mm), Sliding interlock (One vertical length in each shutters) (45.5 mm x 28 mm), Glazing bead (24.5 mm x 16 mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 +– 0.2 mm thick, galvanized steel Frame (30 mm x 18 mm) 02 nos, sliding sash (30 mm x 18 mrn), sliding mesh sash (26 mm x 10 mm) profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners, [Hardware : Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40 mm & required accessories.] Note : The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories.) (Area n.exc 2.00 sqm each.) |
| 78 | M&L for 35mm thick second class hardwood glazed and skeleton door shutters open rebated and prepared to receive glass gauge etc edges of framing plain chamfered or rounded with cut and mitred beads for securing glass/gauges etc with sashbars size of members of shutter as specified in SSR Part-I section 8, clause 8.20 (a) complete all as specified and directed. |
| 79 | S&F, Factory Made Solid PVC Moulded Door Shutters with wood free EPS 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face with Particle Board Core board core, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 80 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC Sheet & edges will be painted to match with prelam sheet, reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed. |
| 81 | S&F Factory made solid panel PVC door shutter30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottomrails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channelhaving a PVC sheet strip of 20mm width stuck inside with solvent cement for stilesand plain colour PVC sheets for top rail, lock rail & bottom rail on either side & asgap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to befitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheetbeading, and joined together with solvent cement, suppling & fixing in the frame atsite as per specification & drawing complete all as specified and directed. |
| 82 | S&F in repair aluminium alloy anodized sliding door bolt with hasp, staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts or extruded sections or cast aluminium alloy length of bolt 300mm complete all as specified and directed by Engr-in-charge. |
| 83 | S&F butt hinges medium weight cold rolled Aluminium anodised 100mm long complete all as specified and directed |
| 84 | S&F stainless steel butt hinges fixed with screws, 100mm long complete all as specified and directed |
| 85 | S&F butt hinges medium weight cold rolled Aluminium anodised 75 mm long complete all as specified and directed |
| 86 | S&F Aluminium anodised barrel tower bolts of extruded section 100mm long complete all as specified and directed |
| 87 | S&F Aluminium anodised barrel tower bolts of extruded section 200mm long complete all as specified and directed |
| 88 | S&F Aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and directed |
| 89 | S&F Aluminium handles cast type anodised of 100mm complete all as specified and directed |
| 90 | S&F Aluminium handles cast type anodised of 125 mm complete all as specified and directed |
| 91 | S&F in repair helical door spring ordinary rat tail rod pattern springs including roller and roller plate complete of mild steel 300 mm long complete all as specified and directed |
| 92 | S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples beads or in steel window complete all as specified and directed by Engr-in-charge. |
| 93 | S&F in repair, aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 94 | S&F sheet glass 3.0 mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane. |
| 95 | S&F in repair 3 mm figured glass, pin head type and glazing with beads fixed with m in squares n exc 0.5 sqm in each pane complete all as specified and directed. |
| 96 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 97 | S&F Aluminium anodised sections with powder coating for doors/windows/ventilators with one or more rebates and rubber packing and roller including joining cleat for fixing etc complete with frames, shutters sliding three track, or fixed or ventlators/Partition including handles, tower bolts, grills, etc includig taking down old shutter complete all as specified and directed. Note:- Floor door spring, sheet glass, wire cloth, lock, etc shall be measured and paid seperatel |
| 98 | S&F 4.8 mm Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane |
| 99 | S&F 12 mm thick 'Prelaminated particle board, interior grade,prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 100 | Taking down rain water pipe of any size or pattern including all fittings complete all as specified and directed. |
| 101 | S&F 110 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 102 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 103 | S&F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 104 | S&F in repair, 110 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 105 | S&F 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 106 | S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 107 | S&F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 108 | S&F in repair, 75 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 109 | S&F in repair, Stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, Including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore of pipe complete all as specified and directed. |
| 110 | S&F in repair, Stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, Including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore of pipe complete all as specified and directed. |
| 111 | Supplying & Laying of 20 mm Outer Diameter, CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 112 | Supplying & Laying of 25 mm Outer Diameter, CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 113 | UNRESTRICTED AREA |
| 114 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed. |
| 115 | M&L for Non Skid coloured ceramic tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over & including 15 mm thick screed bed or bedding layer of 1:6 cement mortar for laying floor finishes complete all as specified and directed. |
| 116 | M&L for Non Skid coloured ceramic tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over & including 15 mm thick screed bed or bedding layer of 1:6 cement mortar for laying floor finishes complete all as specified and directed. |
| 117 | M&L for Glazed coloured ceramic tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick in vertical surface such as dado / skirting / risers to steps etc., set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including rendering 10 mm thick in cement mortar 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. |
| 118 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed. |
| 119 | M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in :6 cement mortar complete all as specified and directed. |
| 120 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in 1:4 cement mortar complete all as specified and directed. |
| 121 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 122 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:6 and to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 123 | M&L for rendering 5 mm thick in cement mortar 1:3 on RCC/ceiling surface and finished even and smooth (without using extra cement) complete all as specified and directed . |
| 124 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:4 and to be finished even and smooth (without using extra cement) complete all as specified and directed. (WPC measured and paid seperately) (height upto 12.50m) |
| 125 | M&L for preparation of newly plastered brick work or concrete surfaces & applying three coats of white wash on prepared brick work or concrete surfaces complete all as specified and directed. |
| 126 | M&L for preparation of newly plastered brick work or concrete surfaces & applying two coats of cement based paint over & including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. |
| 127 | M&L for preparation of newly plastered brick work or concrete surfaces & applying two coats of oil bound distemper over & including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. |
| 128 | M&L for preparation of newly plastered surfaces of ceiling and apply three coats of white wash on prepared ceiling surface.Complete all as specified and directed. |
| 129 | M&L for preparation of newly plastered brick work or concrete surfaces & applying 2 mm thick Wall Care Putty on newly plastered brick work or concrete surfaces complete all as specified and directed . |
| 130 | M&L for applying two coat of oil bound distemper on brick work or concrete surfaces over & including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. |
| 131 | M&L for complete removal of existing treatment on brick work or concrete surfaces or plastered surface & applying 2 mm thick Wall Care Putty on brick work or concrete surfaces complete all as specified and directed . |
| 132 | M&L for preparation of old painted brick work or concrete surfaces or plastered surface & applying one coat of white wash on brick work or concrete surfaces complete all as specified and directed. |
| 133 | M&L for preparation of old painted brick work or concrete surfaces plastered surface & applying one coat of cement based paint on brick work or concrete surfaces complete all as specified and directed. |
| 134 | M&L for preparation of old painted brick work or concrete surfaces or plastered surface & applying one coat of oil bound distemper on brick work or concrete surfaces complete all as specified and directed. |
| 135 | M&L for preparation of old painted ceiling surfaces & applying one coat of white wash on ceiling surfaces complete all as specified and directed. |
| 136 | M&L for preparation of old painted Wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (ordinary tint) complete all as specified and directed. |
| 137 | M&L for preparation of old painted Steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of Synthetic enamel paint (ordinary tint) complete all as specified and directed. |
| 138 | S&F in repair 15mm bore bib tap fancy type chromium plate alloy with a crutch or butterfly handle screwed down for iron pipes or for brass ferrule all as specified and directed by Engr-in-charge. |
| 139 | S&F in repair 15mm bore pillar taps chromium plate alloy fancy type chromium plated screwed down high pressure with or without lattered HOT or COLD with long screwed shanks and fly nuts screwed for iron pipes, att as directed Engr-in-Charge. |
| 140 | Taking down of old existing water proofing treatment on roof surface (Horizontal & Vertical surfaces), including properly cleaning & drying the concrete surfaces complete all as specified and directed. |
| 141 | M&L for Water Proofing Treatment on \\"Non Approachable/Non Accessible and Approachable Roof\\" surfaces (Horizontal & Vertical surfaces) in following sequence through manufacturer/authorized applicator of the manufacturer complete all as specified and directed. |
| 142 | M&L for rendering 10 mm thick in cement mortar 1:4 on roof or concrete surfaces complete all as specified and directed. |
| 143 | M&L for applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg per Sqm complete all as specified and directed. |
| 144 | M&L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg per Sqm including cleaning surfaces complete all as specified and directed. |
| 145 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3 mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on bitumen coated surface with 100 mm overlaps shall be sealed by flame as per manufacturer's instruction complete all as specified and directed. |
| 146 | M&L for preparation of new or previously untreated APP based polymeric membrane surfaces & applying two coats of bituminous based Aluminium Paint complete all as specified and directed. |
| 147 | M&L for providing cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets & railings upto 60 cm in height, copings, roof padding, sunken slab, benching, kneelers, apex stones, bed plates, kerbs, water troughs & the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 148 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for. Complete all specified and directed. |
| 149 | Removing surplus demolished material to a distance exceeding 250 m but not exceeding 500 metre & depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 150 | M&L for rendering 15 mm thick in one layer in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) mixed with liquid water proofing compound (water proofing compound to be measured & paid separately as supply only) complete all as specified and directed. |
| 151 | Supply only liquid water proofing compound ISI marked. Complete all as specified & as directed. |
| 152 | M&L for cement concrete type C-2, 1:3:6 (using 40 mm graded brick coarse aggregate) in sub base or sunken floors, filling & mass concrete complete all as specified and directed. |
| 153 | S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), minimum triple layer, 500 litre capacity, hoisted and fixed in position all as specified in SSR Part-I, including dismantling of old u/s water storage tank complete all as specified and directed. |
| 154 | S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), minimum triple layer, 1000 litre capacity, hoisted and fixed in position all as specified in SSR Part-I, including dismantling of old u/s water storage tank complete all as specified and directed. |
| 155 | S&F ball valves for 20 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed. (Minimum weight 210 gms) complete all as specified and directed. |
| 156 | S&F ball valves for 25 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed (Minimum weight 455 gms) complete all as specified and directed. |
| 157 | S&F in repair ball valves for 20 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed (Minimum weight 210 gms) complete all as specified and directed. |
| 158 | S&F in repair ball valves for 25 mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed (Minimum weight 455 gms) complete all as specified and directed. |
| 159 | S&F in repair PVC Tank cover for Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 or 1000 litre capacity fixed in position with nuts and bolt complete all as specified and directed. |
| 160 | S&F in repair Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed in 15 mm bore dia of pipe complete all as specified and directed. |
| 161 | S&F in repair Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed in 20 mm bore dia of pipe complete all as specified and directed. |
| 162 | Taking up or down 15 mm bore of pipe steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 163 | Taking up or down 20 mm bore of pipe steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 164 | S&F 15 mm bore GI tubes, 'medium grade' galvanised, with all fittings fixed complete to walls or ceilings or laid in floors complete all as specified and directed. |
| 165 | S&F 20 mm bore GI tubes, 'medium grade' galvanised, with all fittings fixed complete to walls or ceilings or laid in floors complete all as specified and directed. |
| 166 | Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) of 15 mm bore of pipe complete all as specified and directed. |
| 167 | Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) of 20 mm bore of pipe complete all as specified and directed. |
| 168 | M&L for Cleaning and removing all scale and dirt, etc., from RCC/PVC tanks exc 250 ltr & not exc 500 ltr capacity & from mouths of circulating pipes, etc. including washing of water tank with the use of Tank cleaning motor jet pressure machine and using bleaching powder & writing date of cleaning with any type of paint including Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 169 | M&L for Cleaning and removing all scale and dirt, etc., from RCC/PVC tanks exc 500 ltr & not exc 1000 ltr capacity & from mouths of circulating pipes, etc. including washing of water tank with the use of Tank cleaning motor jet pressure machine and using bleaching powder & writing date of cleaning with any type of paint including Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 170 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 171 | S&F 12 mm thick plain/designer Gypsum Board False Ceiling with GI Frame work including all necessary drilling, cutting to fix electric items complete all as specified and directed with following :- ( Height of Bldg upto 9mtr) (a) GI Grid Channel 30 mm x 25 mm x 20 mm of guage fixed with rawl plug & screw 450 mm centre to centre along with perimeter walls. (b) GI Channel made to shape 50 mm x 40 mm x 40 mm of 24 guage placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span). (c) GI Intermediate runners of size 45 mm x 10 mm x 10 mm of 24 guage fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span). (d) GI sheet 25 mm wide & 20 mm guage suspended fixed with steel fastners to roof ceiling @ 1200 mm centre to centre including pluging of RCC Slab. (e) 12 mm thick gypsum board filling joints with POP & finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling. |
| 172 | S&F G.I. powder coated snap grid frame work for false ceiling to be interlocked in such a way that the size of grid shall be 605 mm x 605 mm including 6 mm dia G.I. hangers (upto 1200 mm length) adjusting level fixed to roof by means of ceiling cleats made out of G.I. flat 40 mm x 3 mm, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long & 4 mm thick Non asbestos fibre board (E-board or V-board) designer tiles (Electra) suitably fixed in false ceiling grid/frame with staples or screws.Complete all as specified and directed.( Height of Bldg upto 9mtr) |
| 173 | Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 174 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 175 | Dismantling of AC Corrugated or semi corrugated sheet etc any thickness including ridges as in roof covering and stacking at site where directed and removal of debris to a outside MOD land and depositing where directed complete all as directed. |
| 176 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.( Height of Bldg upto 12.50mtr) |
| 177 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. ( Height of Bldg upto 12.50mtr) |
| 178 | S&F Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip & straight flashings (length & girth as fixed) with grade of zinc coating 275 of 1.00mm thick complete all as specified and directed. ( Height of Bldg upto 12.50mtr) |
| 179 | S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates conforming to GDE Fe410-0 or Fe 310-O complete all as specified and directed. |
| 180 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc conforming to GDE Fe410-0 or Fe 310-O complete all as specified and directed.( Height of Bldg upto 12.50mtr) |
| 181 | S&F MS steel flat iron as in wind tie for roof sheet including securing bolts complete all as specified and directed. |
| 182 | M&L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concretean d screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and Fe-290 Gde E-165 all as specified and directed. |
| 183 | M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, hand rails, cupboards frame and similar work conforming to Fe.290.Gde-E-165 with and including necessary cutting and welding complete all as specified and directed.( Height of Bldg upto 12.50mtr) |
| 184 | M & L Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured 'Structural Steel') complete all as specified and directed. ( Height of Bldg upto 12.50mtr) |
| 185 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described & applying two coats of synthetic enamel paint (ordinary tint) over & including one coat of red oxide, zinc chrome primer complete all as specified and directed. |
| 186 | Taking down chowkats or frames n exc1.5 sqm with shutter incl iron monger etc (without taking off shutters from the frames) complete all as specified and directed. |
| 187 | Taking down chowkats or frames exc 1.50sqm but n exc 4 sqm with shutter incl iron monger etc (without taking off shutters from the frames) complete all as specified and directed. |
| 188 | Taking down shutter of any decrti on not exe 1 sqm complete all as specifed and directed |
| 189 | Taking down shutter of any decrti on exe 1 sqm but nexc 2 sqm complete all as specifed and directed |
| 190 | S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 191 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate & natural fibers (wood powder/rice husk/wheat husk) & non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement & screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/sqmm, modules of elasticity 900 N/sqmm & resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant & fixed in position with MS hold fast/lugs/SS dash fasteners of required dia & length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or SS dash fasteners shall be paid for separately). Note : For WPC solid door/window frames, minus 5 mm tolerance in dimension i.e., depth & width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 192 | S & F in repair Factory made single extruded WPC (Wood Polymer Composite) solid door frame of size 125 x 65mm comprising of virgin PVC polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibre (wood powder/rice husk/wheat husk) and non tixic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC slovent cement and screwed with full body threaded star headed SS screws havng minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N (face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticty 900 N/mm2 and resistance to spread of flame of Casss A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed (M.S hold fast/lugs or SS dash fasteners shall be paid for seperately. Note : For WPC solid door minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 193 | S & F in repair Factory made single extruded WPC (Wood Polymer Composite) solid plain skeleton door shutter of 30 mm thick comprising of virgin polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibre (wood powder/rice husk/wheat husk) and non tixic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/cum and screw withdrawal strength of 1800 N (face) & 900 N (Edge), minimum compressive strength of 50 N/mm2, modules of elasticty 850 N/mm2 and resistance to spread of flame of Casss A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessay full body threaded star headed counter sunk S.S screws including and tainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples beads complete all as specified and directed. Note : Stainless steel butt hinges and necessary S.S screws shall be paid separately. |
| 194 | Providing & Fixing Factory made single extruded WPC (Wood Polymer Composite) solid flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate & natural fibers (wood powder/rice husk/wheat husk) & non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum & screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/sqmm, modulus of elasticity 850 N/sqmm & resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter & fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as per direction of Engineer-in-Charge. Note : Stainless Steel butt hinges & necessary S.S screws shall be paid separately. |
| 195 | S&F Powder Coated (minimum thickness of powder coating 50 micron) Anodised aluminium Door/window Shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 02 Nos in each door hinges, anodised aluminium snap beading, screw etc, complete all as specified and directed |
| 196 | S&F mild steel flat iron as in bands, straps, supports or stays for rain water, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 197 | S&F second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 198 | S&F Providing and fixing of double rebate openable/fixed windows (Eco 4000) made of galvanized steel colour coated/powder coated (base steel as per IS 513 of “D\\" quality, galvanized as per IS 277 with zinc of 120 grams/sqm) with total thickness of coating 0.58 mm, primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, outer frame section 72 x 55 mm, centre mullion section 72 x 50 mm, shutter section 47 x 20 mm,fly mesh section 40 x 20 mm and the fixed glass beading section 12 x 12 mm, outer frame and mullions shall consists rebate for glazed shutter, fly mesh and 20 mm provision for guard bars/grills, the sections cut to length mitre joined with corner bracket, centre mullions fixed with mullion cap, stay, handles, latch, 2 Nos of heavy duty stainless steel pivot hinges per shutter and panelled with 4 mm thick plain clear glass and S.S. Mesh for fly mesh shutter (304 grade), fitted using EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing windows in the concrete/masonry wall by means of self-expanding screws, including 10mm Square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. complete all as specified and directed. |
| 199 | Providing and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3 mm (+- 0.2 mm). Window profile with hollow section with multi chamber. Frame (88 mm x 52 mm), sliding sash (42 mm x 67 mm). Sliding mesh Sash (42 mm x 57 mm), Sliding interlock (One vertical length in each shutters) (45.5 mm x 28 mm), Glazing bead (24.5 mm x 16 mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 +– 0.2 mm thick, galvanized steel Frame (30 mm x 18 mm) 02 nos, sliding sash (30 mm x 18 mrn), sliding mesh sash (26 mm x 10 mm) profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners, [Hardware : Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40 mm & required accessories.] Note : The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories.) (Area n.exc 2.00 sqm each.) |
| 200 | M&L for 35mm thick second class hardwood glazed and skeleton door shutters open rebated and prepared to receive glass gauge etc edges of framing plain chamfered or rounded with cut and mitred beads for securing glass/gauges etc with sashbars size of members of shutter as specified in SSR Part-I section 8, clause 8.20 (a) complete complete all as specified and directed. |
| 201 | S&F factory made plain framed ,35 mm Panelled shutter (two Panel) with lock rail of 9 mm B.W.P. commercial ply or 12 mm veneered patticle boar with commercial veneering on both face , the size of rail and stile as per IS: 1003 (Part 1) kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 202 | S&F, Factory Made Solid PVC Moulded Door Shutters with wood free EPS 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face with Particle Board Core board core, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 203 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC Sheet & edges will be painted to match with prelam sheet, reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed. |
| 204 | S&F Factory made solid panel PVC door shutter30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottomrails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channelhaving a PVC sheet strip of 20mm width stuck inside with solvent cement for stilesand plain colour PVC sheets for top rail, lock rail & bottom rail on either side & asgap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to befitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheetbeading, and joined together with solvent cement, suppling & fixing in the frame atsite as per specification & drawing complete all as specified and directed. |
| 205 | S&F in repair aluminium alloy anodized sliding door bolt with hasp, staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts or extruded sections or cast aluminium alloy length of bolt 300mm complete all as specified and directed by Engr-in-charge. |
| 206 | S&F Butt hinges medium weight cold rolled Aluminium anodised 100mm long complete all as specified and directed. |
| 207 | S&F stainless steel butt hinges fixed with stainless steel screws, 100mm long complete all as specified and directed. |
| 208 | S&F Aluminium anodised barrel tower bolts of extruded section 100mm long complete all as specified and directed. |
| 209 | S&F Aluminium anodised barrel tower bolts of extruded section 200mm long complete all as specified and directed. |
| 210 | S&F Aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and directed. |
| 211 | S&F Aluminium handles cast type anodised of 100mm complete all as specified and directed. |
| 212 | S&F Aluminium handles cast type anodised of 125 mm complete all as specified and directed. |
| 213 | S&F in repair 300mm Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified. |
| 214 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy & fixed complete all as specified and directed. |
| 215 | S&F in repair helical Door spring ordinary rat tail rod pattern springs including roller and roller plate complete of mild steel 300 mm long complete. |
| 216 | S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples beads or in steel window complete all as specified and directed by Engr-in-charge. |
| 217 | S&F in repair, aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 218 | S & F Sheet glass 3.0 mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane. |
| 219 | S&F in repair 3 mm figured glass, pin head type and glazing with beads fixed with m in squares n exc 0.5 sqm in each pane complete all as specified and directed. |
| 220 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 221 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples beads or in steel window complete all as specified and directed by Engr-in-charge. |
| 222 | S&F Aluminium anodised sections with powder coating for doors/windows/ventilators /Partition with one or more rebates and rubber packing and roller including joining cleat for fixing etc complete with frames, shutters sliding three track, or fixed or ventlators including handles, tower bolts, grills, etc .including taking down old shutter complete all as specified and directed. Note:- Floor door spring, sheet glass, wire cloth, lock, etc shall be measured and paid separately. |
| 223 | S&F 4.8 mm Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed. |
| 224 | S&F 12 mm thick 'Prelaminated particle board, interior grade,prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 225 | Taking down rain water pipe of any size or pattern including all fittings complete all as specified and directed. |
| 226 | S&F 110 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 227 | S&F 110 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 228 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 229 | S&F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 230 | S&F in repair, 110 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 231 | S&F 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 232 | S&F 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 233 | S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 234 | S&F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 235 | S&F in repair, 75 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 236 | S&F in repair, Stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, Including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore of pipe complete all as specified and directed. |
| 237 | S&F in repair, Stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, Including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore of pipe complete all as specified and directed. |
| 238 | Supplying & Laying of 20 mm Outer Diameter, CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 239 | Supplying & Laying of 25 mm Outer Diameter, CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 240 | Schedule of credit amount of Rs 236648.00 to be deducted during AOC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysAug 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer