Tender For Repair/Maint Of Electric System And Allied Works At Wsa Area Under Ge (Af) Jorhat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Aug 2026
10 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jorhat → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Electric System And Allied Works At Wsa Area Under Ge (Af) Jorhat
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including battens and fittings such as switches, ceiling rose, light fittings, regulators, sockets, etc. and making good to disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 2 | M&L for point wiring complete with 1.5 Sq.mm PVC insulated unsheathed multistranded copper conductor FRLSH cable 1100 volts grade, single core, drawn through and including stove enamelled steel conduit not less than 20mm dia with all flame proof accessories such as junction box, MS coupling, unions branch, reducers, elbow, sealing conduit, etc. and including 1.5 sq.mm PVC insulated unsheathed multistranded copper conductor FRLSH cable (green colour) 1100 volts grade, single core as earth continuity conductor connected to common earth dolly for one light point / fan point controlled by one, one way switch removing materials from site and making good disturbed surfaces f floors/walls/ ceiling, etc. (if so happend during point wiring) ocomplete all as specified and as directed. |
| 3 | All as per Serial Item No. 2 here-in-before but wiring with 2.5 sq.mm PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor cable 1100 volts grade, single core earth continuity conductor connected to common earth dolly for 3/5 pin 6/16 Amps socket outlet on independent board. |
| 4 | S&F switch flame proof rotary type with termination box in LM6, 16 amps, single pole 250 volts complete all as specified and as directed. |
| 5 | S&F flame proof switch socket & plug combination in LM6 cable termination box in LM6, 16 amps, 250 volts, 2p+ earth complete all as specified and as directed. |
| 6 | S&F LED tube light fittings 1x20 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector, etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all spcified and as directed. |
| 7 | S&F LED tube light fittings 30 watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all spcified and as directed. |
| 8 | Refixing of flame proof light fitting of any type and size with complete electrical connection complete all as specified and as directed. |
| 9 | S&F flame proof control panel incommer MCB 2P 40Amps-01 No., outgoing MCB 1P 6Amps -04 Nos. including taking out unserviceable DB with welding, cutting and drilling work of the complete. DBs to be fixed on channel of the frame with necessary nut, bolt and washer with channel/plate of suitable size complete all as specified and as directed. |
| 10 | M&L for for submain wiring with two single core PVC insulated unsheathed cable 6.0 sq.mm with multistranded copper conductor FRLSH cable, 1100 volts grade, drawn through and including rigid steel conduit 20mm bore and continuous earth wire of single core PVC insulated, unsheathed cable 6.0 sq.mm with multistranded copper conductor cable of 1100 volts grade including taking down old unserviceable sub main wiring of any size and making good to disturbed surfaces complete all as specified and as directed. Note : Two run of wiring cable, one run of earth wire and one run of rigid steel conduit shall be measured as one unit. |
| 11 | M&L for submain wiring with two single core PVC insulated unsheathed cable 4.0 sq.mm with multistranded copper conductor FRLSH cable,1100 volts grade drawn through and including rigid steel conduit 20mm bore with accessories and continuous earth wire of single core PVC insulated, unsheathed cable 4.0 sq.mm with multistranded copper conductor 1100 volts grade including taking down old unserviceable sub main wiring of any size and making good to disturbed surfaces complete all as specified and directed. Note : Two run of wiring cable, one run of earth wire and one run of rigid steel conduit shall be measured as one unit. |
| 12 | Dressing of submain wiring of any size by dismantiling of existing point wiring/sub main wiring and old broken casing caping/steel conduit replace with new casing caping/steel conduit of existing size from site and making good to disturbed surfaces of floors/walls/ceiling, etc. complete all as specified and as directed. Note : Casing caping/steel conduit shall be measured and paid seprately. |
| 13 | S&F steel conduit of size 20mm including drawn existing wiring complete all as specified and as directed. |
| 14 | M&L as in repairs and conversion of conventional light to LED light 1x20 watt in existing single side flame proof light fitting suitable for T8 & T5 fitting, complete with all accessories and complete connection with wiring and make good of all distubed surfaces complete all as specified as directed. |
| 15 | M&L as in repairs and conversion of conventional light to LED 2x20 watt light in existing double side flame proof light fitting suitable for T8 & T5 fittings complete with all accessories and complete connection with wiring and make good of all distubed surfaces complete all as specified and as directed. |
| 16 | M&L as in repairs and conversion of conventional light to LED light 1x26 watt / 30 watt in existing bulk head flame proof light fitting, complete with all accessories and complete connection with wiring and make good of all distubed surfaces complete all as specified and as directed. |
| 17 | S&F as in repairs switch flame proof rotary type with termination box in LM6, 16Amps, single pole 250 volts complete all as specified and as directed. |
| 18 | S&F as in repairs flame proof switch socket & plug combination in LM6 cable termination box in LM6, 16 Amps, 250 volts, 2p+earth complete all as specified and as directed. |
| 19 | Supply and laying PVC insulated and FR PVC sheathed, copper conductor (flexible) industrial cable, 1100 volt, conforming to IS 694 electric control cable with copper conductor, 1100 volts grade, cross sectional area 1.50 sq.mm, 3 core including taking down old unserviceable cable one complete all as specified and as directed. |
| 20 | S&F cable junction box 155x210x92mm in size, made out of thermoplastic sheet having IP 66/69 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 Nos) fixed on poles with flat aluminium strip clamps of size 25x3mm, nuts, bolts, washers etc. including taking out old unserviceable cable junction box complete all as specified and as directed.Make : Hensel, Cat Part No. KF 1616 B or equivalent model of makes specified in Particular Specifications. |
| 21 | S&F in replacement of street light LED luminaries with low wattages with pressure die cast housing with heat resistant toughened glass and high power LEDs with secondary optics with IP- 66 protection of cap 60 Watts including 10 KV SPD, after taking old unserviceable light fittings complete all specified and as directed. |
| 22 | S&F in replacement street light LED luminaries with low wattages with pressure die cast housing with heat resistant toughened glass and high power LEDs with secondary optics with IP- 66 protection of cap 70 watts including 10 KV SPD, after taking old unserviceable light fittings complete all specified and as directed. |
| 23 | S&F as in repairs for 120 watt LED (CCT 5700 - 6500 K), cradle / surface mounted flood light made of aluminium die cast housing with power coating, having excellent thermal management along with IP 66 protection with clamp as per site requirment complete all as specified and as directed.Note : LED light with efficiency of 110 lm/W and lumen output of >= 11000 lumen. |
| 24 | Taking down/out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, GI pipes, etc. of any descriptions, laid in trenches and/or fixing with walls/poles including segregating of serviceable materials such as bricks, cables, GI pipes, etc. and keep in safe custody for re-use complete all as specified and as directed. Note: Necessary excavation and earth work shall be measured and paid for separately. |
| 25 | Excavating in trenches not exc. 1.50m wide and not exc. 1.50m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 26 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil complete all as specified and as directed. |
| 27 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.50m above the starting point in soft/loose soil complete all as specified and as directed. |
| 28 | M&L for cable XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade of cross sectional area 16 sq.mm, 4 core laying in trenches/passing through pipe/on wall complete all as specified and as directed.Note: Rate of the saddle and clamp for fixing of cable on wall is deemend to be included with the quoting rate. |
| 29 | All as per Item Serial item No. 28 including note here-in-before but of size 10 Sq.mm, 4 core |
| 30 | All as per Serial item No. 28 including note here-in-before but of size 25 Sqmm, 3.5 core |
| 31 | M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed. Note : For the purpose of payment, punned thickness of sand cushioning shall be measured for payment. |
| 32 | Supply and laying sub-class 'B' bricks, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion for UG cable protection complete all as specified and as directed. |
| 33 | M&L for cutting road/hard standing and making good to disturbed surfaces by using PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) for fixing the pipe complete all as specified and as directed. |
| 34 | Taking down/out unserviceable GI / HDPE pipes of any descriptions, laid in trenches and/or fixing with walls/poles complete all as specified and as directed. |
| 35 | S&F GI pipe 50mm bore (dia), 'light grade' for protection of UG cable laid in floors/road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc. complete all as specified and as directed |
| 36 | S&F 50mm dia low density polyethylene pipe (LDPE) of pressure rating 6 kgf/cm² fixed complete to walls, ceilings or in floors, etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 37 | S&F 50mm dia low density polyethylene pipe (LDPE) of pressure rating 6 kgf/cm² fixed complete to walls, ceilings or in floors, etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysAug 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender