Tender For Repair /Replacement Maintenance Of Lt Panels Apfc Panels Lt Over Head Line Mccbs And Other Connected Works At Lansdowne Under Age(I) Lansdowne
Tender Value
14.95 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
18 days left
EMD
29900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pauri Garhwal → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair /Replacement Maintenance Of Lt Panels Apfc Panels Lt Over Head Line Mccbs And Other Connected Works At Lansdowne Under Age(I) Lansdowne
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard and dense soil complete all as specified and directed. |
| 2 | Returning, filling in, soil including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed. |
| 3 | Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 4 | M&L for spread fine river sand in trenches complete all as specified and as directed. Note: For measurement purpose, punned down thickness shall only be taken. |
| 5 | M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed. |
| 6 | Dismantling insulators any type, any size complete all as speified and directed. |
| 7 | Dismantling of ACSR conductors, any size complete all as speified and directed. |
| 8 | Supply, laying & testing of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 95 Sqmm 3.5 core including taking out old unsv cable from trenches complete all as specified and as directed. Note :- The earth work, GI pipe & Clamp for suitable size to hold the cable on wall shall be measured and paid separately. |
| 9 | All as item No 8 above but 120 Sqmm 3.5 core complete all as specified and directed. |
| 10 | All as item No 8 above but 50 Sqmm 4 core complete all as specified and directed. |
| 11 | Disconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 50 mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed. |
| 12 | Disconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 80 mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed. |
| 13 | M&L for Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed. |
| 14 | M&L for shackle type insulators of 100 mm high, 115 mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts including mild steel straps of size 31x5mm including 14 mm dia bolts complete all as specifiedand directed. |
| 15 | Supply, streching and fixing of over head ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. |
| 16 | Restringing/restretching aluminium conductor or GI wire on existing over head lines including necessary binding with binding wire with insulators, connections of incoming and out going cables, binding with spacers where required, complete all as specified and directed. (Note - Replacement of conductor shall be measured and paid under respective item of sch. total no of conductor in over head line to be taken down shall comprise a minimum of one phase and one neutral and one continuous earth wire and for measurement length of each conductor shall be taken seperately. Please Enable Macros to View BoQ information |
| 17 | Restringing/restretching aluminium conductor or GI wire on existing over head lines including necessary binding with binding wire with insulators, connections of incoming and out going cables, binding with spacers where required, complete all as specified and directed. (Note - Replacement of conductor shall be measured and paid under respective item of sch. total no of conductor in over head line to be taken down shall comprise a minimum of one phase and one neutral and one continuous earth wire and for measurement length of each conductor shall be taken seperately. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender