Tender For Special Repair To Bldg No T-122 & T-133 (Sig Pl Living) &Special Repair To Bldg No T-128 & T-129 (Wet Canteen & Tailor Shop) Of 11Th Battalion The Mahar Regt At Prithi Mil Station Under Ge 863 Ews.
Tender Value
31.02 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
17 days left
EMD
62040
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Bldg No T-122 & T-133 (Sig Pl Living) &Special Repair To Bldg No T-128 & T-129 (Wet Canteen & Tailor Shop) Of 11Th Battalion The Mahar Regt At Prithi Mil Station Under Ge 863 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified. |
| 2 | M&L 25mm thick cement concrete type B-O, 1:2:4 (12.5mm graded agg ) as in sub flooring complete all as specified. |
| 3 | M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer of cement mortar 1:4 complete all as specified. |
| 4 | M&L 75 mm thick PCC 1:3:6 Type C-2 using 20mm crushed stone aggregate as in plinth protection and finished even and smooth without using extra cement complete all as specified. |
| 5 | Bitumastic filling, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, as in plinth protection complete all as specified & directed. |
| 6 | Dismantling of plain or corrugated steel sheeting, any guage, thickness from roof covering complete all as specified. |
| 7 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 8 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 9 | Taking down cement or cement lime plaster any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 10 | M&L 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement (with water proofing compound) complete all as specified and directed. |
| 11 | M&L two coats cement base paint on plastered surface including preparation of newly plastered surfaces complete all as specified. |
| 12 | Dismantling wall and ceiling boards of any description or any thickness including cover fillets as directed. |
| 13 | S&F powder coated GI snap grid of size 605 X 605mm frame work for false ceiling including hangers 2mm dia G.I. (upto 1200mm length) adjusting level fixed to steel member/purlins hangers or roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long whereever required or tie on structural steel complete all as specified and directed.. |
| 14 | S&F Exposed metal frame ceiling with 8mm thick decorative laminated calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mmX600mm grid (frame work for ceiling shall be measured and paid seprately) complete all as specified and directed. |
| 15 | S&F in repairs 19/20 mm dia curtain rails mild steel chromium plated with fixing brackets, stops, roller etc, complete all as specified and directed. |
| 16 | Taking down chowkats or frames(without taking off shutters from the frame) area exc 1.5 Sqm but n.exc 4.0 Sqm each. |
| 17 | Taking down chowkats or frames(without taking off shutters from the frame) area n exc 1.5 Sqm each. |
| 18 | Taking down shutter of any description exc 1 sqm each |
| 19 | S &F 125 x 60mm factory made pressed steel frames conforming to IS, for doors with one or more rebatesmade out of 1.25mm thick mild steerl sheet including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified & directed. |
| 20 | S & F of 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified & directed. |
| 21 | S&F factory made 35mm thick second class hard wood Glazed and skelton door shutters , open rebated and prepare to receive glass, gauge etc, size of members of shutters as specifed in SSR part I, section 8 clause 8.24(b) |
| 22 | S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat of red oxide zinc chrome primer, complete all as specified & directed. |
| 23 | S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat of red oxide zinc chrome primer, complete all as specified & directed. |
| 24 | S&F framed work such as framed guard bars, barred iron doors, grills, gratings, etc with ends of bars shouldered or riveted framed guard bars and similar work confirming to Fe-290. Gde E-165 complete all as specified and directed. |
| 25 | S&F 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified. |
| 26 | S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified. |
| 27 | S&F 100mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified. |
| 28 | S & F butt hinges, 100mm medium weight, cold rolled mild steel complete all as specified. |
| 29 | S&F 150 mm Aluminium handles, cast type, anodised complete all as specified and directed. |
| 30 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares exc 0.5 Sqm, each pane complete all as specified. |
| 31 | Hacking out old broken glass (any thickness) , size, quality or description ) from metal frame including punching or drilling out old glazing pins complete all as specified. |
| 32 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n,exc 0.5 Sqm, each pane complete all as specified. |
| 33 | S & F in repair Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples all as specified. |
| 34 | S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed. |
| 35 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified. |
| 36 | S&F Mild steel work as in Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates(Fe-410-W(Gde E-250)Quality-A) complete all as specified. |
| 37 | M&L for preparation of old surfaces & applying one coat of oil bound distemper on wall as specified. |
| 38 | M&L one coats of synthetic enamal paint to steel surfaces of any discription not otherwise described over 10cm width or girth preparation of old surfaces complete all as specified. |
| 39 | M & L for preparation of old plastered surfaces of wall including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coat of cement based paint complete all as specified and directed. |
| 40 | M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as spd and directed. |
| 41 | Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 42 | M&L for PCC 1:2:4 B1, 20mm graded stone aggregate as in surface channels and drains complete all as specified and directed |
| 43 | Extra forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, mould, mitred/stopped ends etc. complete all as specified and directed |
| 44 | Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 45 | M & L factory made, precast concrete, machine pressed, interlocking paver block any shape and size, conforming to IS 15658-2006, of 80mm thickness, M-40 Grade, with grey cement and pigment,(in top layer),different colours, laid over complete all as specified and directed. |
| 46 | M & L for 40mm thick fine sand cushioning and joints filled with fine sand, complete all as specified and directed. |
| 47 | M&L chequered cement concrete tiles 20cmx 20cmx 25mm thick,set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 20mm thick screed in cement mortar 1:6 |
| 48 | M&L for 75 mm thick P.C.C 1:4:8 type B-2 using 40mm graded stone agg as in sub base of floor complete all as specified and as directed. |
| 49 | M & L for PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in copings, bed blocks, etc including necessary form work complete all as specified and directed. |
| 50 | M&L for PCC 1:2:4 B1, 20mm graded stone aggregate as in surface channels and drains complete all as specified and directed |
| 51 | Demolition of stone/ boluder masonry/ precast concrete block walling masonary/ stone masonry, built in cement mortar or cement lime mortar incl all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles. |
| 52 | M&L for walling of random rubble stone masonry uncoursed, well bonded, bedded and solidly hearted built in CM 1:4. complete all as specified and as directed. |
| 53 | All as per item No. 52 above but except stone complete all as specified. |
| 54 | M&L for precast PCC 1:3:6 type C1 (20mm graded agg) as in bond stones set in cement mortar 1:6 complete all as specified and as directed. |
| 55 | S&F 110 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors after dismantling old one complete all as specified. |
| 56 | M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggrgate as in coping to wall complete all as specifed and as directed. |
| 57 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 58 | M&L for point wiring using approved colour coding as per IS by using FRLS PVC insulated 1.5 Sqmm multistranded,1100 volt grade copper conductor cable unsheathed type, alongwith 1.5 Sqmm FRLS PVC insulated stranded copper conductor cable for continous earthing in & incl casing capping point wiring with accessories having ISI mark for one light/fan/bell point/5 amp indep/power point/same board controlled by one switch complete all as specified and directed. |
| 59 | All as per item No 58 here-in-before but for one multipin socket outlet 5 Amp but using 2x 1.5 + 1 x 1.5 sqmm multistranded FRLS copper cable on the independent board |
| 60 | All as per item No 58 here-in-before but for one multipin socket outlet 5 Amp on the same board with other switches |
| 61 | All as per item No 58 here-in-before but for one multipin socket outlet 15 Amp, but using 2 x2.5 +1 x 2.5 sqmm multistranded FRLS copper cable, independent board |
| 62 | S&F in replacement of switch piano type 5 Amp, 230 Volt, flush type single pole one way complete all as specified and directed. |
| 63 | S&F in replacement of socket outlet multipin 5 Amp 230 Volt flush type complete all as specified and directed. |
| 64 | S&F in replacement of switch piano type 15 Amp, 230 Volt, flush type single pole one way complete all as specified and directed. |
| 65 | S&F in replacement of socket outlet multi pin 15 Amp 230 Volt flush type complete all as specified and directed. |
| 66 | S&F In replacement of for Lamp holder, PVC/Polycarbonate type with back plate suitable for Angle/batten fittings complete all as specified and directed |
| 67 | S&F of rechargeable led bulb minimum 4 Hrs Battery backup 9 Watt B-22 Base complete all as specified and directed. |
| 68 | S&F in rplacement of Ceiling rose, 3 terminal, PVC isolated body complete all as specified and directed |
| 69 | S&F in replacement of LED light fitting 20W, 220 volt AC, having colour temperature daylight (6500K), Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 70 | S&F in replacement LED light fitting 1x10W/1X12W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 71 | S&F including flushing in wall MCB distribution board vertical TPN 4 way 415 volt AC doublr door sheet with bus bar neutral earth bar including provision of MCB TPN 63 amp conforming to IP 43 as incomer complete all as specified and directed. |
| 72 | S&F MCB TPN 63 amp 415 volt with bearing capacity of 16 KA complete all as sp[ecified and directed. |
| 73 | S&F in replacement of sheet metal enclosure double door distribution board single pole and neutral, 12 way 240 volt with 100 amps rated bus bar complete with bus and neutral link complete all as specified and directed. |
| 74 | S&F in replacement of MCB 6 to 32 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 75 | S&F in replacement of MCB SPN 40 amp2 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 76 | Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 16 sqmm 4 core as per IS specification laid through GI pipe/on floor/wall complete all as specified and directed |
| 77 | S&F of double wall corrugated HDPE duct pipe of 50 mm outer dia PN 10 of approved colour with fittings for cable protection complete all as directed. |
| 78 | M&L in replacement of Earthing complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as directed. |
| 79 | Supply, laying and drawing in and including 20 mm dia casing caping including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed. |
| 80 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and leveling of bottom surface to required level all as specified and directed by Engineer- in- Charge. |
| 81 | Returning filling in,. Including spreading, leveling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. |
| 82 | Removing excavated material (i.e. soil) from site to a distance n. exec 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. |
| 83 | Supply and fixing ceiling fans complete with blades, down rods, remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 84 | S&F metal type exhaust fan single phase 230/240V of 300 mm sweep including louvre & cutting of holes in a round shape and including fixing the exhaust fan complete all as specified and directed. |
| 85 | S&F highly BEE star rated energy efficient water heater storage type, electric supplied and installed complete incl all,NRV, PVC connections pipe capacity 25 Litres all as directed By Engr-in-charge |
| 86 | S&F single pole and neutral enclosure with a two pin plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed. |
| 87 | Supply and fixing Building LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed. |
| 88 | S&F for fixing of GI pipe (light grade) bracket of 40mm dia size of 1.2 mtr long bent to shape for fixing of LED street light fittings and fixing to pole, walls etc including fixing of clamp, nut, bolt etc as specified and directed. |
| 89 | Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender