Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56715301

Tender For Repair / Maintenance Of Cabling, Junction Box, Street Lights, Perimeter Lights, Timer Switches At Domestic Area Under Ge (Af) Srinagar.

Issued by Statutory Bodies & Commissions/Committees · Budgam, Jammu and Kashmir
Tender Value
30 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
18 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Cabling, Junction Box, Street Lights, Perimeter Lights, Timer Switches At Domestic Area Under Ge (Af) Srinagar.

BOQ

Name of Work:- REPAIR / MAINTENANCE OF CABLING, JUNCTION BOX, STREET LIGHTS, PERIMETER LIGHTS, TIMER SWITCHES AT DOMESTIC AREA UNDER GE (AF) SRINAGAR.
Sl. No. Item Description
1M&L for maintenence of street light fitting or flood light fitting any type without taking down from pole and removing of carbon deposition, including repacement of LED driver etc., complete all as specified and directed.
2Supply, laying, jointing and testing XLPE insulated of cross sectional area 10 Sqmm 4 Core, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking out existing old unserviceable cable, complete all as specified and directed.Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
3All as per Ser item No 2.00 here in above but cross sectional area 16 Sqmm 4 core.
4All as per Ser item No 2.00 here in above but cross sectional area 35 Sqmm 3.5 core.
5All as per Ser item No 2.00 here in above but cross sectional area 70 Sqmm 3.5 core.
6S&F in replacement 1100 volts grade, heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, of size 10 Sqmm 2 core cable circular in shape, complete all as specified and directed.
7All as per Ser item No 6.00 here in above but cross sectional area 6 Sqmm 2 core.
8Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed
9Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point complete as specified and directed.
10Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing complete all as specified and directed.
11M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc., complete all as specified and directed.
12M&L for laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed
13M&L for cutting the existing bituminous / hard Standing road surfaces and making good disturbed portion for laying of cable / GI pipe etc. and providing 100mm thick plain cement concrete, 1:2:4, type B-2 (using 20 mm graded crushed stone aggregate) for filling up the area of road cutting surfaces and making good the disturbed surface with existing surface, complete all as specified and directed .
14S&F in repairs 80mm dia GI tubing, light grade, with all fittings fixed on walls / poles for protection of cable including clamp 02 Nos of size 25x4 mm, nut bolts, washers etc, complete all as specified and directed.
15S&F in repairs 50mm dia GI tubing, light grade, with all fittings fixed on walls / poles for protection of cable including clamp 02 Nos of size 25x4 mm, nut bolts, washers etc, complete all as specified and directed.
16Fixing only street lights / highbay light / flood light on pole / wall / Hanger ceiling or any psecified height of capacity upto 150 Watt, outdoor type, with high pressure die cast aluminum hosing and heat resistant, complete and all as specified and directed.Note :- street lights / highbay light / flood lights will Be issued under Sch 'B' for free for fixing.
17S&F in repairs LED street Light fitting 90 Watt, system efficiency not less than 110 lumen / watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete all as specified and directed.
18S&F in repairs 170 Watt LED flood light, IP-66 high power with pressure die cast aluminium housing complete with all accessories including 3 core flexible cable from ceiling rose to connector of fitting etc., complete as specified and directed.
19S&F in replacement PVC insulated cu stranded (FRLSH) wire 1.5 sqmm, passing through the non metallic PVC conduit from junction box to LED security light terminals. All connections should be made with proper size of thimbles, complete all as specified and directed.
20S&F in replacement of Rigid non-metallic PVC conduit of size 20mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and directed.
21S&F in replacement PVC weather proof junction boxes of size 250 x 200 x 100mm (Inside dimentions) with PVC connector heavy duty connector 4 way 16 amps ,one No MCB SP 6 Amps and making necessary cable connection, complete all as specified and directed.
22S&F in replacement LED 20 Watt post top lantern, 230 watt volts AC, outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
23S&F in replacement GI Bracket made of 40mm dia GI pipe, medium grade, 1.2m long bend to an angle of 120 degree and fixed to pole with suitable flat iron clamps made out of 32mm x 6mm, 02 Nos including GI nuts, bolts & washer including painting with one coat of red oxide primer, one under coat and one finishing coat with alumminium paint to clamps and GI bracket, complete all as specified and directed.
24S&F in replacement LED bollard lightlight fitting 9W, CCT 5700 K with all fixing accessories fitted on including making suitable foundation for anchoring in PCC 1:2:4, type-B-1, complete all as specified and directed.
25S&F in repairs MCCB 4 pole 415 volts fixed type 100 Amps with breaking capacity 16 KA, complete all as specified and directed.
26S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 160 Amps with breaking capacity 36 KA, complete all as specified and directed.
27S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 200 Amps with breaking capacity 36 KA, complete all as specified and directed.
28S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 250 Amps with breaking capacity 36 KA, complete all as specified and directed.
29S&F in repairs MCCB 4 pole 415 volts microprocessor release type, 400 Amps with breaking capacity 50 KA, complete all as specified and directed.
30M&L for repairing, servicing, painting and replacement of unserviceable parts of any size of LT panels including complete broken accessories such as partialy open door, broken door, unserviceable aluminium bus bar, unserviceable/ broken locking arrangement, repairing of LT Panel legs, welding work, neceassry PCC work, excavtaion and earth work including disconnection and reconnection of cables with suitable size of Al Lugs in proper engineering practice, for any size of cables in any capacity LT Panel also Fixiing of LT Danger Notice Plate both side of the panel, complete all as specified and directed.
31M & L for Painting of LT steel tubular pole of complete lenght, by applying one coat of white cement based paint after scraping / brushing of above GL foundation and cleaning the angle on pole and cross arms and applying a coat of white synthetic enamel painting to pole upto 1.5m from ground level shall be painted by alternate layer of black and Yellow enamel paint (30 cms apart). Pole Number shall be written on pole by black paint in yellow circle of 150mm dia. A coat of aluminium painting shall be done on Cross arm and bracing, nut, bolts and washers etc after preperation of surfaces, complete all as specified and directed.
32Trimming up of Bushes / Tree branches upto 3m all around security light poles both side of the road, removing cut branches from site, complete all as specified and directed.Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3m all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department. (ii) only effected Span at site shall be measured where tree branches are touching nearly HT/LT lines
33S&F in repairs stay assembly with MS stay plate of size 300x300x6mm thick, stay bow, nuts, bolts and check nuts of GI as shown in Electrical Plate No 1 of SSR Part-I (2009) (Dia of stay rod 20mm), complete all as specified and directed.
34M&L for galvanized steel stay strand of size 7 / 2.5 mm inluding Bow and Clamps, complete all as specified and directed.
35S&F in repairs loop type insulator large size with overall dimensions 90mm x 140mm with clearance of hole 25.5mm vitreous white brown or green complete all as required at site, complete all as specified and directed.
36S&F copper conductor unarmoured cable size 6 sqmm, 4 core PVC inner sheathed multi-stranded 1100 volts grade, laid in trench, fixed on wall / pole drawn through pipe etc including provision of lugs & testing, complete all as specified and directed.
37M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing, complete all as specified and directed.
38NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
39Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismantling / taking down items) worth Rs 59,515.00 during AOC.(Note :- Tenderers shall not quote for this Schedule) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56715301
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Cabling, Junction Box, Street Lights, Perimeter Lights, Timer Switches At Domestic Area Under Ge (Af) Srinagar.
Basic Detail
Tender No GE(AF)/SGR-51/2026-27
Bidding Type Tender
Location
City Budgam
State Jammu and Kashmir
Key Dates
Publish Date 28 Jul 2026
Submission Date 19 Aug 2026
Open Date 21 Aug 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
BOQ_875341.xls
c4257de1-348d-4a41-8207-749155d6f10c.html
Tender51.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_875341.xls

html

c4257de1-348d-4a41-8207-749155d6f10c.html

pdf

Tender51.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders