Tender For Repair / Maintenance Of Lt Extension Electrication, Lt Ug Cable, And Allied Works Of East Area And Certain Othere Works Under Ge (W) Bareilly
Tender Overview
Project Description
Tender for Repair / Maintenance Of Lt Extension Electrication, Lt Ug Cable, And Allied Works Of East Area And Certain Othere Works Under Ge (W) Bareilly
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling stay assembly complete from the pole all as specified and directed by Engineer -in-Charge. |
| 2 | M&L for stay assembly complete with accessories and fittings of diameter of stay rod in 20 mm including earth work complete all as specified and directed by Engineer -in-Charge. |
| 3 | Dismantling of LT PCC/steel tubular pole incl coping, foundation etc and serviceable insulators from poles for reuse and shifting of poles to E/M yard or any other location complete all as specified and as directed |
| 4 | Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31, 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Make : Bansal/Jindal/National tube. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately. |
| 5 | M&L for PCC type B1 (1:2:4) using 20 mm graded aggregate as in coping to the poles complete all as specified and directed. |
| 6 | M&L for PCC (1:3:6) type C2 using (40 mm graded aggregate in foundation, filing and mass concrete complete all as specified and directed. |
| 7 | Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles complete all as specified and directed. |
| 8 | Returning, filling in, including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed. |
| 9 | Removing of excavated soft/loose soil not exc 50 m & depositing where as directed at a level n.exc 1.5 m above from starting point completed all as specified and directed. |
| 10 | M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches, punning complete all as specified and directed Note:- Punning thickness of 18 cm will be considered for payment. |
| 11 | M & L for brick protection to cable using old size sub class 'B' bricks, laid flat/length wise perpendicular to the axis of cable all as specified & directed. |
| 12 | Laying only old bricks obtained during excavation complete all as specified and directed. |
| 13 | S&F in replacement 1100 volts grade PVC insulated aluminium conductor screened served with inner sheathed in service connection flat twin core cable of size 10 sqmm complete all as specified and directed. |
| 14 | All as per Ser item No 13 here-in-before but 06 sqmm complete all as specified and directed |
| 15 | Taking out old defective cable from trenches/ floor/road/wall/pipe/pole /service connections of any size , testing with LT magger , seggregating the serviceable part of cables and store for relaying complete all as specified & directed by Engr-in-charge. |
| 16 | Supply and laying of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 10 Sq mm 2 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs. |
| 17 | All as per Ser item No 16 here-in-before but 10 Sq mm 4 core |
| 18 | All as per Ser item No 16 here-in-before but 16 Sqmm 2 core |
| 19 | All as per Ser item No16 here-in-before but 16 Sq mm 4 core |
| 20 | All as per Ser item No 16 here-in-before but 25 Sq mm 4 core |
| 21 | All as per Ser item No 16 here-in-before but 50 Sq mm 3.5 core |
| 22 | All as per Ser item No 16 here-in-before but 95 Sq mm 3.5 core |
| 23 | All as per Ser item No 16 here-in-before but 120 Sq mm 3.5 core |
| 24 | All as per Ser item No 16 here-in-before but 185 Sq mm 3.5 core |
| 25 | All as per Ser item No 16 here-in-before but 240 Sq mm 3.5 core |
| 26 | All as per Ser item No 16 here-in-before but 150 Sq mm 3.5 core |
| 27 | Relaying only serviceable LT UG Cable obtained from taking out old UG cable of any size and discription including necessary cable lugs. ( All relevent items like excavation, earth work, sand cushionning, bricks etc shall be measured seperatly under respective item of Sch.) |
| 28 | M&L for Straight through joints heat shrinkble type 1.1 KV for PVC insulated and sheathed aluminium conductor under ground cable of size 25 to 50 sqmm 3.5 / 4 core including testing of joints after completion complete all as specified and as directed. |
| 29 | All as per Ser item No 28 here-in-before but 120 to 185 sqmm 3.5 core |
| 30 | All as per Ser item No 28 here-in-before but 240 sqmm 3.5 core |
| 31 | M&L Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed. |
| 32 | M&L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 80/50 mm bore at the depth not less than 1 mtr below ground level for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measure and paid separately under respective item. |
| 33 | S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. 50 mm dia |
| 34 | All as per Ser item No 33 here-in-before but 80 mm dia |
| 35 | All as per Ser item No 33 here-in-before but 100 mm dia |
| 36 | M & L fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 250 Amp 36 KA incl making connection /thimbles complete all as sepcified and directed |
| 37 | M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint. |
| 38 | Dismantling of cross arms of MS channel or angle sections etc complete and setting aside for re-use with in 50 mtr complete all as specified and directed. |
| 39 | Dismantling insulators any type any size from LT poles all as specified and directed by Engineer -in-Charge. |
| 40 | M&L for Pin type , porcelain, vitreous, white, borwn or green insulator including one galvanised mild steel spindle , two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 100 mm height, 65 mm dia. |
| 41 | Dismantling of ACSR from the poles all as specified and directed by Engineer -in-Charge. |
| 42 | M&L Aluminium conductor, steel reinforced incl stringing in position all as specified and directed by Engineer -in-Charge. |
| 43 | M&L for earthing complete with galvanised iron steel earth plate of size 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below ground level connected to thick electrode and 32x6 mm GI strip as earthing by means of nuts bolts check nuts and washers made of galvanised iron or steel earth wire protected by galvanised iron pipe 15 mm bore (medium grade) and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 precast RCC cover slab 54 x 54 cm x 5 cm with reinforcement with 8 mm TMT bars @ 150 C/C with one handle and funnel for watering charcoal or coke and salt in alternate layers & necessary earth work in soft/loose soil complete all as shwon in electrical plate No 5 of SSR Part-I including testing on completion all as specified and directed. |
| 44 | M&L for painting the external exposed surfaces of steel tubular swaged/rail poles alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground complete all as directed. |
| 45 | Material and labour for Cutting of bushes and cleaning the area around the sub station including two pole/four pole structures premises complete all as specified and as directed. |
| 46 | S&F of PVC LT OH line spacer for 5 wires complete all as specified and directed. |
| 47 | S&F of PVC LT OH line spacer for 4 wires complete all as specified and directed. |
| 48 | S&F of PVC LT OH line spacer for 3 wires complete all as specified and directed. |
| 49 | Removal of Tree fallen on HT/LT overhead lines by cutting branches,bushes by electric cutter or manual and lifted by crane /Hydra/Manual including collection and depositing the retrieved timber at a place as directed by Engineer-in-charge. |
| 50 | Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. Please Enable Macros to View BoQ information |
| 51 | Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender