Tender For Certain Misc Repairs To Leakage/Seepage In Sunken Floors, Roof Treatment, Roof Sheets, Brickwork, Plastering Etc Including Connected Works At Mil Stn Dharchula Under Ge(Mes) Pithoragarh
Tender Overview
Project Description
Tender for Certain Misc Repairs To Leakage/Seepage In Sunken Floors, Roof Treatment, Roof Sheets, Brickwork, Plastering Etc Including Connected Works At Mil Stn Dharchula Under Ge(Mes) Pithoragarh
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | DESCRIPTION OF ITEMS |
| 2 | Demolition of cement concrete in ground floor,paving nexc 15cm thick(below or above GL) complete all as specified and directed. |
| 3 | M&L providing cement concrete type B0, 1:2:4 (12.5mm aggregate) in roof kerbs or mud stops,coping, rounded or chamfered on edges complete all as specified and directed. |
| 4 | M & L water proofing treatment on existing roof including removing exisitng treatment/screed bed,roughening etc. with the following speification complete(a) M&L for 15mm thick screed bed in CM 1:4 on roof surface finishing the surface using extra cement incl water proofing compound(water proofing compound to be measured and paid for separately). (b) Apply bituminous primer @ 0.5 Ltr/Sqm confirming to IS 3384-1965 on prepared surface till the surface is properly pregnated.(c) Apply hot bitumen 85/25 grade @ 1.2 Kgs/Sqm confirming to IS 702-1988. (d) Laying App based polymeric water proofing membrane minimum weight not less than 3.0 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven fabric (Wt not less than 150 gms/sqm) laid on primed surface by forced application complete with as per manufacturer instructions confirming to IS complete all as specified and directed. (e) Applying a coat aluminium paint min. 0.20ltr/sqm as per manufacturer's instructions. |
| 5 | M&L for sunken floor treatment as described as under (i) to (vi) :-(i) Demolition of cement concrete of any description and in any position not otherwise specifically provided or in any type,filled in sunken portion & cleaned the sunken portion incl dismantling plastering wall surface complete as directed.(ii) M& L 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:4) 15 mm thick mixed with water proofing compound as per manufacturer instructions(water proofing compound to be measured and paid for separately). Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time complete all as specified and directed.(iii) Spouts of 40mm dia GI pipe medium grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed as specified and directed. (iv) After laying sewage/ plumbing pipes with fixtures in position 2 coats of EP-101 epoxy compound shall be applied complete all as specified and directed.(v) The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed, the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated.(vi) The sunken floor shall again be filled with PCC (1:5:10) type E-2 using over the treated surface upto top for fixing of WC complete all as specified and directed.Note -Mode of Measurement (i) Sunken slab to be treated up to 450 mm depth.(ii) Bottom area of sunken slab will only be measured for qty calculation and payment |
| 6 | Supply only liquid water proofing compound |
| 7 | Demolition of brick work, stone/boulder masonary built in cement mortar complete all speecified and directed |
| 8 | M&L for Pre-cast cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed. |
| 9 | Taking down cement plaster on brick or stone walls, of any description including raking out joints, hacking for key, scrubbing down with water, etc complete all as spfd and directed. |
| 10 | M&L 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces including finishing the surfaces fair and even without using extra cement complete all as specified and directed. |
| 11 | M&L 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surface including finishing the surfaces fair and even without using extra cement complete all as specified and directed. |
| 12 | M&L for Preparing new plastered wall surfaces and applying two coat of oil emulsion distemper over a coat of plaster of paris putty of 1mm thckness over plastered surface to prepar the surface even and smooth complete all as specified and directed. |
| 13 | M&L for preparing newly plastered surface of wall apply two coat of cement base paint over a coat of white wash complete all as specified and directed |
| 14 | M&L three coats of white wash on wall surfaces including prepration of new plastered surfaces complete all as specified and directed |
| 15 | Dismantling mild steel work of any description and in any position complete all as specified and as directed. |
| 16 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and gastenings and heavy brackets framing (beam, tee, angle channel or flat sections) (Fe-290 Gde E-165) including distance pieces, cleats etc. |
| 17 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets,fittings etc. as specified and directed. |
| 18 | S&F False Ceiling Horizontal level regular edge grid 600 x 600 mm form work using hot dip sections and fixing tiles vinyl laminated MPL gypsum panels size 595x595x6 to 8mm thick after lamination, suspended the grid with grid hangers to Roof Truss / RCC Slab all as spfd and directed. |
| 19 | M&L for 6mm thick Plywood, grade BWR, type BB, fixed in ceiling and walling with screws to timber frame work complete all as sfd and directed. |
| 20 | M&L II nd class hard wood plain fillets square or rectangular in section cleansawn but bullnosed chamfared or rounded on one edge or face sectional area exc 3 sqcm and nexc 6 sqcm secured in nails complete all as specified and directed |
| 21 | Dismanteling of timber scantling 40 sqcm and over in section in any position for unframed works complete all as specified and directed |
| 22 | M&L for 2nd class hard wood as in scantling clean sawn framed & fixed as in ceiling and walling wks, complete all spfd & directed. |
| 23 | Dismantling of timber scantling 40 Sqcm under in section in any position, fixed with nails unframed work complete all as spfd & directed. |
| 24 | M&L for II nd class hard wood plain fillets squaree or rectangular in section clean sawn secured with nails sectional area exc 13 sqcm and n.exc 25 sqcm complete all as specified and directed |
| 25 | M&L for one coat of creasote oil to wooden surfaces new or old of any description including prepration of surfaces complete all as specified and directed. |
| 26 | Dismantling of plain or corrugated steel sheeting of any guage/thickness in roof covering/wall clading complete all as spfd and directed |
| 27 | S&F 0.63 mm th galvanised corrugated mild steel sheeting with two corrugation side lap fixed with 'L' type or 'J' type or cranked hook bolts fixed to roof covering/cladding to wall complete all as spfd & directed |
| 28 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 29 | S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 30 | M&L for two coat of synthetic enamel paint over a coat of pink primer to new wooden surface of any description exc 10 cm girth or width including prepration of new wooden surfaces complete all as specified and directed |
| 31 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer to new steel surfaces of any description over 10 cm in width or girth incl preparation of new steel surfaces complete all as spfd and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender