Tender For Provn Of Tarrace Tilesand Roof Treatmentat Bldg No P-50/8(Offrs Mess) Of 2119 Field Hospital, Provn Of Standby Electric Supply From 160 Kva Dg Set Loc At Oxygen Generation Plant To Hospital Complex Bldg At 161 Mh , And Other Misc Minor Wor

Issued by Statutory Bodies & Commissions/Committees · Pithoragarh, Uttarakhand
Tender Value
32.06 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
19 days left
EMD
64200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pithoragarh → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Tarrace Tilesand Roof Treatmentat Bldg No P-50/8(Offrs Mess) Of 2119 Field Hospital, Provn Of Standby Electric Supply From 160 Kva Dg Set Loc At Oxygen Generation Plant To Hospital Complex Bldg At 161 Mh , And Other Misc Minor Works At Mil Stn Pithoragarh Under Ge(Mes) Pithoragarh

BOQ

Name of Work:- PROVN OF TARRACE TILESAND ROOF TREATMENTAT BLDG NO P-50/8(OFFRS MESS) OF 2119 FIELD HOSPITAL, PROVN OF STANDBY ELECTRIC SUPPLY FROM 160 KVA DG SET LOC AT OXYGEN GENERATION PLANT TO HOSPITAL COMPLEX BLDG AT 161 MH , AND OTHER MISC MINOR WORKS AT MIL STN PITHORAGARH UNDER GE(MES) PITHORAGARH
Sl. No. Item Description
1DESCRIPTION OF ITEMS
2Dismantling of existing floor hearth or wall tilling include cement mortar bedding removing servicable tiles to store and rubbish off from premises.
3Demolition of plain cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
4Taking down cement plaster of any description, thickness on brick, stone, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, removal of rubbish and cleaning, etc complete as directed and specified.
5M&L for cement concrete 1:2:4 type, B1 using 12.5 mm graded stone aggregates mixed with water proofing compound as in copings, roof padding/staging of water tank etc including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed
6M&L for rendering 10 mm thick , in cement mortar 1:4 over RCC slab, mixed using water proofing compound liquid @ 200 ml per bag of cement. Complete all as specified and directed.
7Supply only liquid water proofing compound complete all as specified and directed.
8M & L for cutting chases, pinning in brick/PCC blocks wall for app membrane and making good to facings where required and pointing in cement mortar 1:3. complete all as specified and as directed
9M & L for water proofing treatment to accessible roofs surfaces including a coat of applied bituminous shalitex primer @ 0.30 lit per sqm evenly on roof surface and a coat of hot bitumen 85/25 @ 1.2 kg/sqm shall be applied on primed surface and laying of 3mm thick APP modified polymeric membrane (weight not less than 3 kg/sqm) unrolled and bonded completly to the substrate with side overlap of 75 mm and end overlap of 100 mm and then sealed/fused by flame or bitumen and a coat of hot blown bitumen grade 85/25 @ 1.2 kg/sqm shall be applied on top of APP modified polymeric membrane as per manufacturer instruction.
10S&F Heavy duty outdoor tiles of size not exceeding 0.36 sqm, 8-10mm thick set and jointed in neat cement slurry laid with 2 mm spacer filled with epoxy grout of colour as specified by engr-in-charge, as in floor over and incl 15mm thick cement screed bed in CM 1:4 complete all as specified and as directed.
11M&L for brick work with old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified and directed.
12M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) (nominal mix) as in slabs supported on wall, landing, balconies, canopies, deck slabs and in shelves and like in repair to Chajjas, Claddings, soffits etc including bonding agent, complete all as specified and directed.
13M&L for form work to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat, complete all as specified and directed.
14M&L for TMT Bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete incl welding etc (if reqd) all as specified and directed.
15M&L for 15mm thick rendering on fair faces of brick/ concrete surfaces in CM 1:4 finished even and fair. Complete all as specified and directed.
16M & L 16 to 18 mm thick granite( colour as approved by GE) stone slab machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform/dado/skirting /plateform counter top WHB in cluding cutting holes for oval shape /urinal partitions etc. including 15 mm thick cement screed bed 1:6 CM in horizontal or vertical surfaces including grinding the edges half round and polishing complete all as specified and directed by Engineer-In- Charge.
17M&L Glazed ceramic coloured tiles/wall cladding tiles size not exceeding 0.16 sqm , 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match on vertical surfaces of wall incl 10 mm thick rendering on brick surface in CM 1:4. complete all as specified and as directed.
18M & L Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms, Parapet walls and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
19M&L for extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work not exc 15 cm in width or girth; including cutting to edges, all mitres and stopped ends etc.complete all as specified and as directed
20S & F 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls/floors with necessary fittings complete all as specified & directed.
21Material & Labour for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Complete all as specified and directed.
22Material & Labour for complete removal of existing treatment from walls upto plastered surface then prepared plastered surfaces finally rubbed and smooth with sand paper and then applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces. Complete all as specified and directed.
231. Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in hard / dense soil complete all as specified and directed.
242. Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/ disintegrated soil complete all as specified and directed.
253. Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
264. Removing excavated soil n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
275. M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches complete all as specified & directed. Note- Punned thickness of sand will be measured (18 cm) and paid under relevant item.
286. Supply & Laying brick old class sub-class 'B' designation of size 230x115x75 mm for protection of under ground LT cable complete all as specified and as directed.
297. Supply , laying, jointing & testing of XLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, corss sectional area 10 Sqmm 4 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items.
306. Supply , laying, jointing & testing of XLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, corss sectional area 16 Sqmm 2 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items.
318. Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
329. Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws asspecified type 410 SP-31 (9 mtr long) swan neck type complete with CI base plate and final and single swan neck including painting complete. Excavation, PCC for foundation and coping paid saparately.
3310. Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermalmanagement in multiple optics complete with IP 65/66 protection alongwith mounting bracket with suitable clamp, nut, bolt and washers etc complete all as specified and as directed by Engineer –in-Charge.
3411. Supply and fixing Junction box with aluminium bus bar suitable for three phase & Neutral , 4 wire of capacity 32 Amps and MCB 6 amps TPN complete with fixing clamps etc.
3512. Supply and connecting twin core cord flate weather proof cable, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 2 x 2.5 Sqmm 1100 Volt , draw through LT steel tubular poles for connection to street light from junction box as directed by Engr- in- Charge.
3615. Material and labour for PCC (set in cement mortar 1:4) type B1 1:2:4 using 20 mm grade stone aggregate as in copping of electric pole at site including providing necessary form work complete all as specified and as directed by the Engineer in charge
3716. M&L in repair for PCC 1:3:6 type C-2,using stone aggregate 40 mm graded as in foundation of stays and coping of poles including necessary form work where required and fair finish to the exposed surfaces complete all as specified and directed.
3817. M&L in repair for PCC 1:4:8 type D-2,using stone aggregate 40 mm graded as in foundation of stays and coping of poles including necessary form work where required and fair finish to the exposed surfaces complete all as specified and directed.
399. S & F 1x250 watt LED Flood light fitting , PDC housing,IP-65 with 4 KV inbuilt surg protection driver, pressure die-cast aluminium including fixing the same including necessary cutting / bending /welding and fixed the same with two Nos FI clamps of 40x 4mm duly painted and suitable size of nut & bolts etc. and making electric connection with PVC three core copper flexible wire complete all as specified and directed.
4010. M & L for junction box hot press moulded SMC of inside dimension size 250 x200x 100 mm and outside dimention 295 x 255 x 120 mm with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having aluminium bus bar 4 strips of 20x3mm for TPN on necessary epoxy base insulator and fixing of 6 Amp MCB SPN, including necessary 25x3mm flat iron clamps with nuts, bolts & washers all as specified and directed.
4111. Material and labour for 2.5 Sqmm 3 core PVC heavy duty electric service cable with aluminium conductor 1100 volts grade complete all as specified and directed.
4214. Supply and fixing Digital street light timing switch having lighting control (ON-OFF) through digital 24 Hrs. and pre-wired with suitable size copper conductor single core PVC sheathed cable and all mechanism fitted into LT feeder pillar box (KIOSK) outdoor type, pole mounted. The panel shall be dust and vernin proof, made of CRCA MS sheet fixed with 25mm X 4mm thick MS flate iron strip complete with nuts, bolts & washwers, duly powder coated finish. Front opening type with locking arrangement complete all as specified and directed suitable for single phase and neutral with under and over voltage protection relay, contactor 32A TP, MCB 40A SPN, 250 volts, 50 Hz, AC supply system. complete all as specified and directed.
437. Supply, installing, commissioning and testing LT panel board (out door type) cubical type made out of CRCA sheet 3.15 mm thick dust and vermin proof and angle iron of suitable size, pedestal frame grouted in PCC (1:2:4) type B-1 20mm graded stone aggregated thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminium bush bar of capacity 500 Amps, TPN, three phase, 04 wire (In separate chamber) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following :- (Proposed LT Panel near Oxygen Plant Room - 01 No)(Proposed LT Panel near MI Room - 01 No)
44(a) Supply and fix 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 01 No (Incoming)
45(b) Supply and fix 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 02 Nos
46(c) Supply and fix 4 Pole onload Change over Switch 250 Amp, 50 Hz, 415 V - 01 No.
47(d) Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA with Thermal megnatic relay adjustable type – 01 No
48(e) Digital Voltmeter with built in selector switch 0-500Volts -1No
49(f) Digital Ammeter with built in selector switch 0-500 amps with suitable CTs -1No
50(g) LED Indicated Lamp (R,Y,B) one Set-01
51(h) PCC and earth wk for installation of Panel complete.
52Supply, installing, commissioning and testing Busbar Chamber of size 900mm x 600mm x 300mm factory made of aluminium basbar of size 50mm x 6mm fixed on porcelain insulatores TPN type out door seather/vermin proof with both way opening duly provided with neoprene rubber gasket along wieth doors opening pedestal type duly painted powder coated on CRCA sheet encloser with one No incommer MCCB 250 Amps 36 KA 4 pole. The busbar chamber to be routed inj ground b y usinhg angle iron of size 40mm x 5mm, four Nos of angle iron supports duly enbaded in foundation using PCC (1:2:4) Type C-1 w3ith 20mm graded stoprne aggregate in cl making. The panel board shall have bottom channel of size 75X40mm properly welded with 90CM long 04 legs of angle iron 50X50X6 mm using 305 mm thick CRCA sheet corners to all legs and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of Alimunium lugs and suitable size of chorme plated brass doble compression glands provided for incoming and out-going cables all as specified or indicated including testing on completion.
53Supply, install, testing and commissioning of Hot & cold type inverter type split air conditioner with expandable technology( 100 percent copper, dust filter, penta sensor , superfine mesh filter) complete unit, electric driven, single phase 230V, 50 Hz with copper pipe duly insulated and electrical cable of suitable size, mounting bracket and required accessories for installation and commissioning with following specification complete:(a) Capacity-1.5 TR/Min 3star Rating (b) Technology- Variable speed dual inverter technology.(c) Compressor Type- High EER Twin ratory compressor(d) Condenser coil-100% copper.(e) Operating voltage range-145V-270V (Without Stabilizer)(f) Star rating- Min 3 star(g) Air Filter- Anti dust, anti bacteria
54Supply, install, testing and commissioning of Hot & cold type , inverter type split air conditioner complete unit, electric driven, single phase 230V, 50 Hz with copper pipe duly insulated and electrical cable of suitable size, mounting bracket and required accessories for installation and commissioning with following specification complete:(a) Capacity- 2.0 TR/3 Starr rating Minimum(b) Technology- Variable speed dual inverter technology.(c) Compressor Type- High EER Twin ratory compressor(d) Condenser coil-100% copper.(e) Operating voltage range-145V-270V (Without Stabilizer)(f) Star rating- Min 3 star(g) Air Filter- Anti dust, anti bacteria
55Supply and fix 4 KVA Capacity voltage stabilizer suitable for for 1.5 TR inverter type split AC, automatic operation, single phase naturally air cooled, indoor type & disigned for input variation between 130 volt to 300V volts, with output voltage stabilized at 230 volts with acuracy of 2.5% complete all as specified and directed
56Supply and fix 5 KVA Capacity voltage stabilizer suitable for for 2.0 TR inverter type split AC, automatic operation, single phase naturally air cooled, indoor type & disigned for input variation between 130 volt to 300 volts, with output voltage stabilized at 230 volts with acuracy of 2.5% complete all as specified and directed
571. Supply, installation, commissioning and testing of 3 Phase Sequence Corrector Panel of capacity 150 Amp, 440V, 50 Hz, Outdoor duty (IP54 enclosure) comprising the following :-(a) MCCB 3 Pole, 160 Amp, breaking capacity 36 KA - 01 No.(b) Contactor, 165 Amp, 3 Phase - 02 Nos.(c) MCB SP 220V, 6 Amp. - 03 Nos.(d) Indicator RYB - 01 Set.(e) Voltage Monitoring Relay of suitable capacity - 02 Nos.(f) Surge Protection Device - 01 No.(g) CT, 180/5 Amp - 01 Set.(h) On Indicator lamp (ON) - 01 Set.(j) On button - 01 No.(k) Selector switch (Auto/Manual) - 01 No.(l) Multi Function Meter -
58M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 8.0 mm thick buried directly in ground, earth pit not less than 2.25 mt deep below ground level with top edge of the earth plate not less than 150 mm below ground level and earth plate surrounded with charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded in to earth plate at one end and connected to main equipment at switch/control board at another end. GI earth lead (in case and including one 50 mm dia GI light grade pipe from upper end of earth plate up to equipment) with including 20 mm dia bore water pipe and provision of PCC 1:2:4 (using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg) complete all specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56715268
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 32.06 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Tarrace Tilesand Roof Treatmentat Bldg No P-50/8(Offrs Mess) Of 2119 Field Hospital, Provn Of Standby Electric Supply From 160 Kva Dg Set Loc At Oxygen Generation Plant To Hospital Complex Bldg At 161 Mh , And Other Misc Minor Works At Mil Stn Pithoragarh Under Ge(Mes) Pithoragarh
Basic Detail
Tender No GE/PGH/61 of 2026-27 (8805/PGH/E8)
Bidding Type Tender
Location
City Pithoragarh
State Uttarakhand
Key Dates
Publish Date 28 Jul 2026
Submission Date 19 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 32.06 Lakhs
Tender Fee 500
EMD 64200
Exemption Available
Document List
826c9941-a846-428e-a029-fdd498ef9c80.html
BOQ_875194.xls
TENDERDOCUMENT61.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

826c9941-a846-428e-a029-fdd498ef9c80.html

xls

BOQ_875194.xls

pdf

TENDERDOCUMENT61.pdf

pdf

Tendernotice_1.pdf