Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56715259

Tender For Special Repair/Replacement Of Damaged Lt Panels ,Earthing And Lighting Conductors At Lekhapani Mil Stn Under Ge Dinjan No.2

Issued by Statutory Bodies & Commissions/Committees · Tinsukia, Assam
Tender Value
28.50 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
18 days left
EMD
57000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair/Replacement Of Damaged Lt Panels ,Earthing And Lighting Conductors At Lekhapani Mil Stn Under Ge Dinjan No.2

BOQ

Name of Work:- SPECIAL REPAIR/REPLACEMENT OF DAMAGED LT PANELS ,EARTHING AND LIGHTING CONDUCTORS AT LEKHAPANI MIL STN UNDER GE DINJAN NO.2
Sl. No. Item Description
1S & F of Air termination rod , single pointed aluminium rod 12mm dia and 300mm long alongwith all fixng accessories including taking down old damaged air termination rod complete all as specified and directed by Engineer in charge
2Supply & fix aluminium strip 25 mm x 3 mm complete with saddles , imsulators of suitable size and fixing accessories for roof and down conductor including taking down old strip complete all as specified and directed by Engineer in charge
3Supply and fix test point termination block of size 75 mm x 75 mm x 25 mm made of Gun Metal or phospherous bronze drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw and box of size 90 x 90 x 90 mm (Made out of 1.6 mm thickplain brass sheet) and screwed to wall for protection of test point complete including taking down old test terminal point complete all as specified and directed by Engineer in charge
4Supply and Fix GI Pipe \\"Light Grade\\" 25 mm dia includes all fixing accessories on roof for fixing of Air Termination Rod complete all as specified and directed by Engineer in charge
5Supply and Fix GI Pipe \\"Light Grade\\" 50 mm dia includes all fixing accessories on wall as Earth strip protection pipe alongwith wall including taking down old pipe complete all as specified and directed by Engineer in charge
6M&L for Galvanised iron strip 32 x 6mm buried in ground for interconnection earthing including 50mm GI light grade pipe for earth strip protection complete all as specified and directed by Engineer in charge
7Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for laying under ground GI earth Strip etc and getting out any type soil complete all as specified and directed by Engineer in charge
8Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm complete all as specified and directed by Engineer in charge
9Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and directed by Engineer in charge
10M&L for Boring of holes under road, pavement, hard standing by trenchless technology technique for 40-80 mm dia pipe complete all as specified and directed by Engineer in charge
11M&L for PCC 1:2:4 type B-1 for holding GI pipe post for air terminal on roof and for repair of PCC hardstanding complete all as specified and directed by Engineer in charge
12M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point/panel upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
13M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead wire of 4mm dia galvanised by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point/panel upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 15 mm dia GI pipe light grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
14M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of of suitable size and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting to both internal and external surfaces with powder coating paint in heat process in grey colour incl mounted on PCC foundation upto a suitable height as required at site with earth work and connecting items, comprising the following complete all as specified and as directed by Eng-in-charge.(i) INCOMING :- (a) MCCB, 4P, 350 Amps, 36 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) Digital voltmeter 3 Phase( 0-500 volt)of suitable size having accuracy class 1.0, 4.5 digit LED display - 01 No.(c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VA with LED display, of suitable size with 3 Nos - 01 No (d) LED R-Y-B indicating lamps (Set of Three)- 01 set and internal wiring with suitable size of copper cable.(ii) BUSBAR :- Aluminium bus bar for 4 pole of capacity not less than 550 Amps- 01(iii) OUTGOING:- (a) MCCB, 4P, 160Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(b)MCCB, 4P, 100Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos (1 + 1 Spare)(c) MCCB, 4P, 63 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos (1 + 1 Spare)(d) MCB,SPN, 32 Amp,16kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos
15M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of of suitable size and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting to both internal and external surfaces with powder coating paint in heat process in grey colour incl mounted on PCC foundation upto a suitable height as required at site with earth work and connecting items, comprising the following complete all as specified and as directed by Eng-in-charge.(i) INCOMING :- (a) MCCB, 4P, 250 Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) Digital voltmeter 3 Phase( 0-500 volt)of suitable size having accuracy class 1.0, 4.5 digit LED display - 01 No.(c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VA with LED display, of suitable size with 3 Nos CT - 01 No (d) LED R-Y-B indicating lamps (Set of Three)- 01 set and internal wiring with suitable size of copper cable.(ii) BUSBAR :- Aluminium bus bar for 4 pole of capacity not less tha 400 Amps- 01(iii) OUTGOING:- (a) MCCB, 4P, 100Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos (1 + 1 Spare)(b) MCCB, 4P, 63 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos (1 + 1 Spare)(c) MCB,SPN, 32 Amp,16kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos
16M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of of suitable size and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting to both internal and external surfaces with powder coating paint in heat process in grey colour incl mounted on PCC foundation upto a suitable height as required at site with earth work and connecting items, comprising the following complete all as specified and as directed by Eng-in-charge.(i) INCOMING :- (a) MCCB, 4P, 200 Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) Digital voltmeter 3 Phase( 0-500 volt)of suitable size having accuracy class 1.0, 4.5 digit LED display - 01 No.(c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VA with LED display, of suitable size with 3 Nos CT - 01 No (d) LED R-Y-B indicating lamps (Set of Three)- 01 set and internal wiring with suitable size of copper cable(ii) BUSBAR :- Aluminium bus bar for 4 pole of capacity not less than 300 Amps- 01(iii) OUTGOING:- (a) MCCB, 4P, 63Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos (1+ 1 Spare)(b) MCCB, 4P, 40 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 03 Nos (2 + 1 Spare)(c) MCB,SPN, 32 Amp,16kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos
17M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of of suitable size and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting to both internal and external surfaces with powder coating paint in heat process in grey colour incl mounted on PCC foundation upto a suitable height as required at site with earth work and connecting items, comprising the following complete all as specified and as directed by Eng-in-charge.(i) INCOMING :- (a) MCCB, 4P, 160 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) Digital voltmeter 3 Phase( 0-500 volt)of suitable size having accuracy class 1.0, 4.5 digit LED display - 01 No.(c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VA with LED display, of suitable size with 3 Nos CT - 01 No (d) LED R-Y-B indicating lamps (Set of Three)- 01 set and internal wiring with suitable size of copper cable.(ii) BUSBAR :- Aluminium bus bar for 4 pole of capacity not less than 250 Amps- 01(iii) OUTGOING:- (a) MCCB, 4P, 100 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos (1+ 1 Spare)(b) MCCB, 4P, 63 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos (1 + 1 Spare)(c) MCB,SPN, 32 Amp,16kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos
18M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of of suitable size and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting to both internal and external surfaces with powder coating paint in heat process in grey colour incl mounted on PCC foundation upto a suitable height as required at site with earth work and connecting items, comprising the following complete all as specified and as directed by Eng-in-charge.(i) INCOMING :- (a) MCCB, 4P, 125 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) Digital voltmeter 3 Phase( 0-500 volt)of suitable size having accuracy class 1.0, 4.5 digit LED display - 01 No.(c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VA with LED display, of suitable size with 3 Nos CT - 01 No (d) LED R-Y-B indicating lamps (Set of Three)- 01 set and internal wiring with suitable size of copper cable.(ii) BUSBAR :- Aluminium bus bar for 4 pole of capacity not less than 200 Amps- 01(iii) OUTGOING:- (a) MCCB, 4P, 63 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos (1+ 1 Spare)(b) MCCB, 4P, 40 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos (1 + 1 Spare)(c) MCB,SPN, 32 Amp,16kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos
19M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of of suitable size and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting to both internal and external surfaces with powder coating paint in heat process in grey colour incl mounted on PCC foundation upto a suitable height as required at site with earth work and connecting items, comprising the following complete all as specified and as directed by Eng-in-charge.(i) INCOMING :- (a) MCCB, 4P, 125 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) Digital voltmeter 3 Phase( 0-500 volt)of suitable size having accuracy class 1.0, 4.5 digit LED display - 01 No.(c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VA with LED display, of suitable size with 3 Nos CT - 01 No (d) LED R-Y-B indicating lamps (Set of Three)- 01 set and internal wiring with suitable size of copper cable.(ii) BUSBAR :- Aluminium bus bar for 4 pole of capacity not less than 200 Amps- 01(iii) OUTGOING:- (a) MCCB, 4P, 40 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 04 Nos (3 + 1 Spare)(b) MCB,SPN, 32 Amp,16kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos
20Supply & fix Timer distribution board/street light panel outdoor type IP 54 rating as per standard specification and suitable size of capacity 32/40A, (Min Load Capacity 6 KW) 230 volt single pole with astronomical/digital time switch, contactor, MCBs and out going terminal with necessary mounting arrangement as per sample including complete all as specified and directed by Engineer-in-Charge. Note : height of the panel shoulld not less than 600mm from GL.
21S&F of sheet metal enclosure vertical distribution board MCCB DB 4 way (VTPN) double door powder coated complete alongwith suitable size of rated Bus bar, isolated neutral bar 415 Volts rated bus bar IP 54 protection, with and including MCCB 4 Pole 100 Amp adjustable type 16 kA as incommer and MCBs as outgoing dully groted on wall with opening arrangemnt including making coonection of suitable size of lugs/ thimbles/ glands including taking down existing DB complete all as specified and directed by Engineer in charge
22S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA 'C' series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed by Engineer in charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56715259
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 28.50 Lakhs
LAST DATE 18-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair/Replacement Of Damaged Lt Panels ,Earthing And Lighting Conductors At Lekhapani Mil Stn Under Ge Dinjan No.2
Basic Detail
Tender No 8979/E8
Bidding Type Tender
Location
City Tinsukia
State Assam
Key Dates
Publish Date 28 Jul 2026
Submission Date 18 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value 28.50 Lakhs
Tender Fee 500
EMD 57000
Exemption Available
Document List
4f4f89c4-c8a4-4447-8b08-54fb8c3306df.html
BOQ_875212.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

4f4f89c4-c8a4-4447-8b08-54fb8c3306df.html

xls

BOQ_875212.xls

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer