Tender for Tender for Construction Work Of 10 B.Ed Triad Area In 100 Sai Joint Hospital, Hardoi
Tender Value
26.20 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
5 days left
EMD
53000
Bank guarantee accepted
Document Fee
944
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hardoi → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Work Of 10 B.Ed Triad Area In 100 Sai Joint Hospital, Hardoi
BOQ
| Sl. No. | Item Description |
| 1 | Clearing jungle including up rooting of rank vegetation grass bush wood trees and sapling of girth upto 30cm. Measured at a height of 1 meter above ground level and removal of rubbish upto a distance of 50m. outside the periphery of area cleared as per SI.No. 2.31 |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil as per SI.No. 2.8.1 |
| 3 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration as per SI.No. 2.35.3.1 |
| 4 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (Under Floor) as per SI.No. 2.25 (a) |
| 5 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. as per SI no 2.27 |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) As per SI no. 4.1.8 |
| 7 | Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) as per SI No- 6.1.2 |
| 8 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) as SI No-5.1.2 |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Upto Plinth Lvl as SI No-5.1.2 |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Above Plinth Lvl as SI No-5.2.2 |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Upto Plinth Lvl as SI No-5.1.2 |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Lvl as SI No-5.3 |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). as per SI No. 5.3 |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (Slab) as per SI No. 5.3 |
| 15 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per SI. No.- 5.22 B.1 |
| 16 | Brick work with common burnt clay bricks of M-150 Class in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand ) as per SI no 6.13.2 |
| 17 | Brick work with common burnt clay bricks of M-150 Class in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ) as per SI no 6.4.2 |
| 18 | Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. In grantings, frames, guard bar, ladder, railing, brackets, gates and similar works as per SI no. 10.25.2 |
| 19 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windowscomprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profilesduly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process ofrequired length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, After fixing frame the gap between frame and adjacent finished wall. DSR 9.147A |
| 20 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides DSR 10.29.2 |
| 21 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement as per SI No-11.20.1 |
| 22 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer in M.S. tube. as per SI no-10.26.1 |
| 23 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory, all complete with 4.0 mm thick glass panes. As per IS 10.30.1 |
| 24 | 15 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) Inner Side as per IS 13.5.2 |
| 25 | 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) Outer Side as per IS 13.4.2 |
| 26 | 15 mm thick cement plaster of mix 1:4 ( 1 cement & 4 coarse sand )Below Plinth as per IS 13.5.1 |
| 27 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone ) finished with floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. 40 mm thick floor 20 mm nominal size stone aggregate. As SI No. 11.3.1 |
| 28 | Providing & laying rectified glazed ceramic floor tiles of size 300x300 mm or more ( thickness to be specified by the manufacturer), of 1st quality confirming to IS:15622, of approved make, in colours white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grounting the joints with white cement and matching pigmrnts etc., complete as per SI no. 11.39 |
| 29 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. as per SI no. 11.37 A |
| 30 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (25 mm thick). As per SI No-11.26 |
| 31 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm as per SI no 11.41.2 |
| 32 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to 1.8. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc complete. Size of Tile 600x600 mm as per SI no 11.46.2 |
| 33 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture as per Sl no. -13.62.1 |
| 34 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre as per Sl no. -13.41.1 Two Coats |
| 35 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per Sl no. -13.46.1 Two Coats |
| 36 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plasterd wall surface even and smooth surface as per Sl no. -13.80 |
| 37 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter. As per SI- 12.41.2 |
| 38 | Centering and shuttering including stutting, propping etc. and removal of form. Beam /Band as per SI- 5.9.5 |
| 39 | Centering and shuttering including stutting, propping etc. and removal of form. Column as per SI- 5.9.6 |
| 40 | Centering and shuttering including stutting, propping etc. and removal of form. Foundation as per SI- 5.9.1 |
| 41 | Centering and shuttering including stutting, propping etc. and removal of form. Slab as per SI- 5.9.3 |
| 42 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. DSR 13.9.1 |
| 43 | S/ Fixing of Sign Board |
| 44 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 45 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 46 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 47 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 48 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 49 | Add for Invertor wiring in wiring point for Light/Fan/Plug with 1.5 mm Cu Wire. |
| 50 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 51 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 52 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. - CAT-AAA |
| 53 | Supply and fixing of recess/Surface/Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect CAT-AAA |
| 54 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00,Air deliveryminimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. |
| 55 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 56 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 57 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes |
| 58 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 4 way (4 + 12), Double door |
| 59 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 60 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 61 | Supplying and fixing of 40 Amp. 4 Pole MCB (10KA) CAT-A |
| 62 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 50 sq. mm 3-1/2 core |
| 63 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. |
| 64 | Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. |
| 65 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 66 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 67 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. (a) White Vitreous China Flat back wash basin size 550 x 400 mm with single 15 mm C.P. brass pillar tap. |
| 68 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe (a) 32mm dia |
| 69 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 70 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall 25mm dia nominal dia pipes |
| 72 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Concealed work, including cutting chases and making good the walls. 15mm dia nominal dia pipes |
| 73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Concealed work, including cutting chases and making good the walls. 20mm dia nominal dia pipes |
| 74 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. (a) 15mm nominal bore |
| 75 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 (a) 15mm nominal bore |
| 76 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (a) 15mm nominal bore |
| 77 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 (a) 15mm nominal bore |
| 78 | Providing and fixing gun metal gate valve with wheel of approved quality. (a) 25mm dia nominal bore |
| 79 | Providing and fixing brass stop cock of approved quality. (a) 15 mm nominal bore |
| 80 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 81 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. (a) Pipes 80mm to 300mm diameter. |
| 82 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. (a) 100mm diameter |
| 83 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete (b) 150mm diameter |
| 84 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. (a) 100mm diameter S.W. Pipe |
| 85 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. (b) 150mm diameter S.W. Pipe |
| 86 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 150 x 100 mm size P type |
| 87 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 7.5 (i) For Sewer Line |
| 88 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. From 0.00 mt to 1.50 mt |
| 89 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 1.50mt to 3.0 mt |
| 90 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. |
| 91 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete, excluding cost of form- work, in foundation and floors. |
| 92 | Reinforced cement concrete work in beams, suspended floors, roof having slope upto 15 degree, landings, balconies, shelves, chajjas, lintels, bands, staircases and spiral staircases etc. above plinth level up to floor V level, excluding the cost of centering, shuttering, finishing and reinforcement : in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)-Slab |
| 93 | Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 94 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per SI. No.- 5.22 B.1 |
| 95 | 12 mm cement plaster in single coat on rough side of single or half brick wall finished with a floating coat of neat cement. (1) 1 cement : 3 Coarse sand |
| 96 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 97 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 3989, 75 mm diameter |
| 98 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) |
| 99 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. Circular shape 450 mm internal diameter |
| 100 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. Circular shape 500 mm internal diameter |
| 101 | Centering & shuttering including strutting, propping etc. and removal of form for slab Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender