Tender For Shifting Of Electrical System In Between Kothawa-Mall Road Due To Road Widening & Strengthening Under Jurisdiction Electricity Distribution Division-Snadila.
Tender Overview
Project Description
Tender for Shifting Of Electrical System In Between Kothawa-Mall Road Due To Road Widening & Strengthening Under Jurisdiction Electricity Distribution Division-Snadila.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-Aug-2026 | Date Exte00012 | Date | 10-Aug-2026 |
| 2 | 10-Aug-2026 | Date | Date | 17-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply and erection of follwing material |
| 2 | Cross arm holding clamp PCC 11 mtr |
| 3 | Holding clamp for PCC 8.5 |
| 4 | 11 kv F-clamp/F bracket |
| 5 | LT shackle insulator |
| 6 | Bolt & nut for shakcle insulator |
| 7 | Eye hook |
| 8 | Stone pad 300×300×75mm |
| 9 | Three phase distribution box clamp |
| 10 | holding clamp for PCC pole |
| 11 | Safe loading Carriage & unloading of following material from store centre to pit site/JE dump store approx 35 Km. |
| 12 | GI wire 3.15 mm 10 swg |
| 13 | Stay Set |
| 14 | Top channel MS 100×50×2240 mm |
| 15 | Dropper channel MS 100×50×2000 mm |
| 16 | T-off channel |
| 17 | M.S. Angle 65×65×6 mm |
| 18 | PCC pole 8.5 mtr. Long |
| 19 | PCC pole 11 mtr. Long |
| 20 | ABC cable (1×16+1×25) sq.mm. |
| 21 | ABC cable (3×50+1×35+1×16) sq.mm. |
| 22 | ABC cable (3×120+1×95+1×16) sq.mm. |
| 23 | Earthing Rod |
| 24 | Distribution box single phase |
| 25 | 11 kv polymeric disc insulator 45KN |
| 26 | 11 kv polymeric pin insulator |
| 27 | 11 kv disc fitings |
| 28 | Distribution box three phase |
| 29 | ACSR rabbit conductor |
| 30 | X-arm M.S. Angle 65×65×6mm V type |
| 31 | Erection & Stringing and Sagging of 11 KV & LT line |
| 32 | Erection of PCC 8.5 mtr long Single pole with all accessories (All neccessary decentralized material like clamp,angle,channel,nut bolt etc will be provided by the contractor at his own cost) |
| 33 | Erection of PCC 8.5 mtr long Double pole with all accessories (All neccessary decentralized material like clamp,angle,channel,nut bolt etc will be provided by the contractor at his own cost) |
| 34 | Erection of PCC 11 mtr long Single pole with all accessories (All neccessary decentralized material like clamp,angle,channel,nut bolt etc will be provided by the contractor at his own cost) |
| 35 | Concreating of pole |
| 36 | Ordinary earthing by 11 KV MS earth Rod 2500 mm long as per RESPO schedule. All material except earthing rod shall be supplied by the contractor. |
| 37 | Grouting and Nozzling of 11 KV / 33 kv stayset complete including fixing of necessary clamps. Accessories required including its grouting by civil material (sand, brick blast & cement). All material except stay wire shall be supplied by the contractor. |
| 38 | Dismentling and mounting of Existing 25 KVA T/F on newly constructed double pole including its commissioning and complete energization (All neccessary decentralized material like clamp,angle,channel,nut bolt etc will be provided by the contractor at his own cost) |
| 39 | Supply and Installation of LT fuse set installed in SMC Box for 25 KVA T/F (All neccessary decentralized material like clamp,angle,channel,nut bolt etc will be provided by the contractor at his own cost) |
| 40 | Dismentling and mounting of Existing 16 KVA T/F on newly constructed Single pole including its commissioning and complete energization(All neccessary decentralized material like clamp,angle,channel,nut bolt etc will be provided by the contractor at his own cost) |
| 41 | Dismentling and mounting of Existing 10 KVA T/F on newly constructed Single pole including its commissioning and complete energization(All neccessary decentralized material like clamp,angle,channel,nut bolt etc will be provided by the contractor at his own cost) |
| 42 | Supply and Installation of LT bakelite fuse set for 10 & 16 KVA T/F |
| 43 | Placement of existing 11/0.4 KV T/Fs from site to newly constructed T/Fs plinth & installation commissioning of 250 KVA T/Fs plinth and including jumpering with the system (All neccessary decentralized material like clamp,angle,channel,nut bolt etc will be provided by the contractor at his own cost) |
| 44 | Construction of T/F plinth of size 1.5x1.5x1.5 Cu. mtr on a padding 0.25M deep in ground 1:5:10 cement sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr height & 0.35 mtr wall will be constructed. Rest wall should be 0.23 mtr thick. Brick work in ratio 1:4 cement & cores Sand in the hollow portion the sand should be filled from the ground level up to 15 centimetres below from the top of wall, Cement, sand & brick Ballasts should be filled up to 15 centimetre. Two no. of channel 100x50 in length 1500mm will be grouded.0.35 CM.RCC will be done with cores sand, cement and stone ballast in the ratio of 1:2:4.The T/Fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand.(All the material to be arranged by the contractor). |
| 45 | Construction of FRP type T/F fencing of size 2.5x2.5x2 Rmt. |
| 46 | Boring type earthing with 20 mtr deep or up to water level providing GI pipe 1.5'' dia (''B'' Class) and earthing must be joint in T/F body, netural & Fuse unit by GI Stripe of size 32×5 mm thick long attached with nut & bolts and GI pipe cap (All the material will be arranged by the contractor at his own cost.) |
| 47 | Stringing & Sagging ABC Cable (1×16+1×25) sq.mm winding & jumpering of LT Line With AB Conductor as per RESSPO norms. (Only AB Conductor will be Provided by the department. Other balance materials like holding clamp, eye hook, suspension clamp & dead end clamp arranged by the contractor at his own cost) |
| 48 | Stringing & Sagging ABC Cable (3×50+1×35+1×16) sq.mm winding & jumpering of LT Line With AB Conductor as per RESSPO norms. (Only AB Conductor will be Provided by the department. Other balance materials like holding clamp, eye hook, suspension clamp & dead end clamp arranged by the contractor at his own cost) |
| 49 | Stringing & Sagging ABC Cable (3×120+1×95+1×16) sq.mm. winding & jumpering of LT Line With AB Conductor as per RESSPO norms. (Only AB Conductor will be Provided by the department. Other balance materials like holding clamp, eye hook, suspension clamp & dead end clamp arranged by the contractor at his own cost) |
| 50 | Fixing of single phase distribution box with clamps and nut bolts |
| 51 | Fixing of three phase distribution box with clamps and nut bolts |
| 52 | Stringing & Sagging of ACSR Rabbit conductor on 11 KV line. (All neccessary decentralized material like clamp,angle,channel,nut bolt etc will be provided by the contractor at his own cost) |
| 53 | Guarding of 11 KV line With Guarding Angle and Clamps (All neccessary decentralized material like clamp,angle,channel,nut bolt etc will be provided by the contractor at his own cost) |
| 54 | Cutting of tree brances for HT/LT line clearance. |
| 55 | Dismentling and Carriage of scrap mateial from site to store/Je dump store |
| 56 | Dismentling and carriage of 11 KV Damage pole |
| 57 | Dismentling and carriage of existing Damage Double Pole |
| 58 | Dismentling and carriage of existing ABC conductor of different size Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender