Tender For Replacement Of 220 Kv Main Bus Bar From Single Tarantulla Conductor To Acsr Twin Moose Conductor & Other Related Work At 220 Kv S/S Boner Under Etd-I Aligarh
Tender Value
5.73 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
10 days left
EMD
6800
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Aligarh → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of 220 Kv Main Bus Bar From Single Tarantulla Conductor To Acsr Twin Moose Conductor & Other Related Work At 220 Kv S/S Boner Under Etd-I Aligarh
BOQ
| Sl. No. | Item Description |
| 1 | Supply |
| 2 | PG Clmap for Moose -Moose Conductor |
| 3 | PG Clmap for Moose -Zebra Conductor |
| 4 | PG Clmap for Zebra-Zebra Conductor |
| 5 | 250 MM Spacer for Twin Moose Conductor |
| 6 | Teminal connector For 245 kv Bus CVT suitable for ACSR Zebra conductor. |
| 7 | Bolted Type Tention Fitting Suitable for ACSR Twin Moose Conductor without turn Buckle |
| 8 | Bolted Type Suspention Fitting Suitable for ACSR Twin Moose Conductor |
| 9 | Teminal connector For 245 kv Bus Isolator suitable for ACSR Twin Zebra conductor |
| 10 | Works |
| 11 | Dismantling of old & existing 220 KV main bus (span approx 36 meter) of all 3 phase of Tarantulla conductor after opeing the tension fitting from gantry, lowering down the Bus etc including shifting of old conductor fitting etc from switchyard to sub station store (1 job per section) |
| 12 | Dismantling of old & existing 220 KV main bus (span approx 18 meter) of all 3 phase of Tarantulla conductor after opeing the tension fitting from gantry, lowering down the Bus etc including shifting of old conductor fitting etc from switchyard to sub station store (1 job per section) |
| 13 | Opening of old & existing dropper jumpers of ACSR zebra conductor between old main Bus to Bus isolator |
| 14 | Erection of Main Bus Bar (approx span 36 meter per saction) by laying & sringing of twin moose conductor including hosting of disc insulator strings, Tension fitting etc. to be provided by the department after due cutting/fixing of conductor of required size to complete the work satisfactory including shifting of all material from store to switchyard . |
| 15 | Erection of Main Bus Bar (approx span 18 meter per saction) by laying & sringing of twin moose conductor including hosting of disc insulator strings, Tension fitting etc. to be provided by the department after due cutting/fixing of conductor of required size to complete the work satisfactory including shifting of all material from store to switchyard .(Note:- Total Double moose conductor laying in a single length of 36+18=54 meter each length) |
| 16 | New Jumper of ACSR Zebra conductor in between main Bus & Bus isolator of 220 KV main bus. |
| 17 | Fixing of twin moose suspension fitting under Bus Bar section of 220 KV main bus below the gantries with suitable Hardware & disc insulator. |
| 18 | Fixing of spacer clamp at an equal interval between twin moose on Busbar section. |
| 19 | Safe Loading of 03 No. 245 KV CVT from 220 KV S/S Khair & Unloading at 220 KV S/S Boner Aligarh With the help of hydra & skilled manpower & all other associated work to complete the job satisfactory ( Hydra & Manpower arrange by the contractor at his own coast ) |
| 20 | Safely Carriage of 03 No. 245 KV CVT from 220 KV S/S Khair To 220 KV S/S Boner Aligarh (dist. upto 65KM ) With the help of Truck & skilled manpower & all other associated work to complete the job satisfactory ( trcuk & Manpower arrange by the contractor at his own coast ) |
| 21 | Dismantelling of Old & difective 245 KV CVT from 220 KV Boner-Aligarh (400 kv ) ckt-II Bay at 220 kv S/S Boner aligarh. Work inclusive of removing of earthing, Opening of jumper, opening of all termination ,cabling and CVT shifting stom 220 KV S/Y to store room & all other associated work to complete the job satisfactory as per direction by site engineer . |
| 22 | Erection of New 245 KV CVT from 220 KV Boner-Aligarh (400 kv ) ckt-II Bay at 220 KV S/S Boner Aligarh. Work inclusive of Making of earthing, jumpering, and all termination /cabling related work & all other associated work to complete the job satisfactory as per direction by site engineer (Note-Hydra,welding machine, skilled worker consumable material like as lugs, farrul,cable Glands if required arrange by the contractor at his own coast) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender