Power Boards / Undertakings / PSU Closing in 10 days TDR #56714705

Tender For Replacement Of 220 Kv Main Bus Bar From Single Tarantulla Conductor To Acsr Twin Moose Conductor & Other Related Work At 220 Kv S/S Boner Under Etd-I Aligarh

Issued by Boards / Undertakings / PSU · Aligarh, Uttar Pradesh
Tender Value
5.73 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
10 days left
EMD
6800
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Aligarh → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of 220 Kv Main Bus Bar From Single Tarantulla Conductor To Acsr Twin Moose Conductor & Other Related Work At 220 Kv S/S Boner Under Etd-I Aligarh

BOQ

Name of Work:- Replacement of 220 KV Main bus Bar from single Tarantulla Conductor to ACSR Twin Moose conductor & other related work at 220 KV S/s Boner under ETD-I Aligarh
Sl. No. Item Description
1Supply
2PG Clmap for Moose -Moose Conductor
3PG Clmap for Moose -Zebra Conductor
4PG Clmap for Zebra-Zebra Conductor
5250 MM Spacer for Twin Moose Conductor
6Teminal connector For 245 kv Bus CVT suitable for ACSR Zebra conductor.
7Bolted Type Tention Fitting Suitable for ACSR Twin Moose Conductor without turn Buckle
8Bolted Type Suspention Fitting Suitable for ACSR Twin Moose Conductor
9Teminal connector For 245 kv Bus Isolator suitable for ACSR Twin Zebra conductor
10Works
11Dismantling of old & existing 220 KV main bus (span approx 36 meter) of all 3 phase of Tarantulla conductor after opeing the tension fitting from gantry, lowering down the Bus etc including shifting of old conductor fitting etc from switchyard to sub station store (1 job per section)
12Dismantling of old & existing 220 KV main bus (span approx 18 meter) of all 3 phase of Tarantulla conductor after opeing the tension fitting from gantry, lowering down the Bus etc including shifting of old conductor fitting etc from switchyard to sub station store (1 job per section)
13Opening of old & existing dropper jumpers of ACSR zebra conductor between old main Bus to Bus isolator
14Erection of Main Bus Bar (approx span 36 meter per saction) by laying & sringing of twin moose conductor including hosting of disc insulator strings, Tension fitting etc. to be provided by the department after due cutting/fixing of conductor of required size to complete the work satisfactory including shifting of all material from store to switchyard .
15Erection of Main Bus Bar (approx span 18 meter per saction) by laying & sringing of twin moose conductor including hosting of disc insulator strings, Tension fitting etc. to be provided by the department after due cutting/fixing of conductor of required size to complete the work satisfactory including shifting of all material from store to switchyard .(Note:- Total Double moose conductor laying in a single length of 36+18=54 meter each length)
16New Jumper of ACSR Zebra conductor in between main Bus & Bus isolator of 220 KV main bus.
17Fixing of twin moose suspension fitting under Bus Bar section of 220 KV main bus below the gantries with suitable Hardware & disc insulator.
18Fixing of spacer clamp at an equal interval between twin moose on Busbar section.
19Safe Loading of 03 No. 245 KV CVT from 220 KV S/S Khair & Unloading at 220 KV S/S Boner Aligarh With the help of hydra & skilled manpower & all other associated work to complete the job satisfactory ( Hydra & Manpower arrange by the contractor at his own coast )
20Safely Carriage of 03 No. 245 KV CVT from 220 KV S/S Khair To 220 KV S/S Boner Aligarh (dist. upto 65KM ) With the help of Truck & skilled manpower & all other associated work to complete the job satisfactory ( trcuk & Manpower arrange by the contractor at his own coast )
21Dismantelling of Old & difective 245 KV CVT from 220 KV Boner-Aligarh (400 kv ) ckt-II Bay at 220 kv S/S Boner aligarh. Work inclusive of removing of earthing, Opening of jumper, opening of all termination ,cabling and CVT shifting stom 220 KV S/Y to store room & all other associated work to complete the job satisfactory as per direction by site engineer .
22Erection of New 245 KV CVT from 220 KV Boner-Aligarh (400 kv ) ckt-II Bay at 220 KV S/S Boner Aligarh. Work inclusive of Making of earthing, jumpering, and all termination /cabling related work & all other associated work to complete the job satisfactory as per direction by site engineer (Note-Hydra,welding machine, skilled worker consumable material like as lugs, farrul,cable Glands if required arrange by the contractor at his own coast) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56714705
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 5.73 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Uttar Pradesh Power Transmission Corporation Limited
Work Description Tender for Replacement Of 220 Kv Main Bus Bar From Single Tarantulla Conductor To Acsr Twin Moose Conductor & Other Related Work At 220 Kv S/S Boner Under Etd-I Aligarh
Basic Detail
Tender No ETC-30/2026-27
Bidding Type Tender
Location
City Aligarh
State Uttar Pradesh
Key Dates
Publish Date 28 Jul 2026
Submission Date 10 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value 5.73 Lakhs
Tender Fee 590
EMD 6800
Exemption Not Available
Document List
30.pdf
9265e567-3a5d-4efc-b317-c13170aa2842.html
BOQ_2202804.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
pdf

30.pdf

html

9265e567-3a5d-4efc-b317-c13170aa2842.html

xls

BOQ_2202804.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders