Civil Aviation Boards / Undertakings / PSU Closing in 18 days TDR #56709037

Bids Are invited for Manpower Outsourcing Services - Minimum Wage - Skilled; High School; Others , Manpower Outsourcing Services - Minimum Wage - Unskilled; High School; Others - Annual Maintenance Contract Of Fire Hydrant Including All Pumps, Panels

Issued by Boards / Undertakings / PSU · Diu, Daman and Diu
Tender Value
17.13 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
18 days left
EMD
51393
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Diu → Daman and Diu
EMD Exemption
Not Available
Quantity
3

Project Description

Bids Are invited for Manpower Outsourcing Services - Minimum Wage - Skilled; High School; Others , Manpower Outsourcing Services - Minimum Wage - Unskilled; High School; Others - Annual Maintenance Contract Of Fire Hydrant Including All Pumps, Panels, Cables, Piping , Hydrants Etc. , Intelligent Type Analogue Addressable Fire Alarm System And Sprinkler System Including All Pumps, Panels, Cables, Piping, Sprinklers Etc. At Aurangabad Airport For All Preventive Maintenance And Checks As Per Manufacturers Manual Including Attending To Complaints/ Faults/ Break Down And Taking Rectification Action, Ensuring Serviceability/ Satisfactory Working Conditions Of The System, Maintenance Of All Records, Documentation Etc. As Per The Detailed Specifications, Terms & Conditions Covered Under This Contract On All Days Including Sundays And Holidays As Per Requirements Of Aai. , Annual Maintenance Contract Of Kirloskar Make Dg Pump Set (With Specification Mentioned Under (A)) I/C Engine Control Panel And Other Accessories Of Dg Pump Set.Job Includes Monthly Visits For Carrying Out Preventive Maintenance, Attending Any Number Of Breakdown Calls When Required, Carrying Out B And C Check, Minor Repairs Etc. As Per Manufacturers Recommendations / Standard Practice And As Per The Scope Of Work, Complete As Required. A) Engine Type - 6R1080, Rating - 79 Hp, Rpm - 1500, Governing Class - M2. , Supplying, Installation, Testing & Commissioning Of Conventional Photo Electric Smoke Detector With Builtin Led And Mounting Base Complete With All Connections Complying To Relevant Is Etc. As Required.(Approved Makes : Apollo/ Edwards (Utc)/ Siemens/ Bosch/ Notifire/ System Sensor/ Morly Ias). , Supplying, Installation, Testing & Commissioning Of Addressable Photo Electric Smoke Detector With Builtin Led And Mounting Base Complete With All Connections Complying To Relevant Is Etc. As Required. (Approved Makes : Apollo/ Edwards (Utc)/ Siemens/ Bosch/ Notifire/ System Sensor/ Morly Ias). , Supplying, Installation, Testing & Commissioning Of Conventional Multi Sensor Detector With Builtin Led And Mounting Base Complete With All Connections Complying To Relevant Is Etc. As Required.(Approved Makes : Apollo/ Edwards (Utc)/ Siemens/ Bosch/ Notifire/ System Sensor/ Morly Ias). , Supply, Installation, Testing & Commissioning Of Ul / En Listed (Latest Version) Intelligent Addressable Multi Criteria Detector {Smoke + Heat } With Inbuilt Fault Isolator / Isolator Base And With Unique Optical Sensing Chamber, Visible Led, Fully Coated Circuit Board, Superior Rf / Transient Protection Suitable For 2 Wires Loop Connection, Complete With Plug Into Common Separate Base & Housing Constructed Of Lexan (Or Polycarbonate) Complete With Connections Etc. As Required And To Be Installed Below / Above False Ceiling Roof And Concealed Space And As Per Enclosed Specifications ,Complete As Required. (Cost Of Plug In Common Base Shall Deemed To Be Included In Cost Of Detectors) , Supplying, Installation, Testing & Commissioning Of Conventional Manual Call Box Of Abs Type In Surface/Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc.Complying To Relevant Is Etc. As Required.(Approved Makes : Apollo/Edwards (Utc)/ Siemens/ Bosch/ Notifire/ Morley Ias/System Sensor/Group4/ Minimax). , Supplying, Installation, Testing & Commissioning Of Conventional Response Indicator On Surface/Recess Ms Box Having Two Leds Metallic Cover Complete With All Connections Etc. Complying To Relevant Is Etc. As Required. (Approved Makes : Apollo/Edwards (Utc)/ Siemens/ Bosch/ Notifire/ Morley Ias/System Sensor/Group4/ Minimax). , Supplying, Installation, Testing & Commissioning Fire Alarmsounder With Facility To Make Announcement, Mounted In M.S.Box (16 Swg) With Hinged Cover Plate & Suitable For Operationwith Lifier I/C Line Matching Transformer Etc. Complete Asrequired.(Approved Makes : Apollo/Edwards (Utc)/ Siemens/ Bosch/ Notifire/ Morley Ias/System Sensor/Group4/ Minimax). , Supplying, Installation, Testing & Commissioning Of Conventional Fire Alarm Panel , 16 X 2 Dotmatrix Lcd Display, Suitable For Eight Zones, Complete With Visual Indications For Short Circuit Fault, Open Circuit Fault, Fire Condition And All Otherstandard Facilities As Per Is:2189, Complying Relevant National Fire Alarm Code For Local Fire Alarm System With Mimic Diagram For Allarea/Zone Covered, Complete With All Connections. The Panel Shall Have Input Of 240 Volts Ac Power Supply, Automatic Battery Charger, 24 Volts, 2 X 12 Volts, 12 Ah Sealed Lead Acid Maintenance Free Batteries Sufficient For 24 Hours Normal Power Backup & Working, Interconnections. The Panel Shall Be Ul Listed & Fm Approved And Shall Be Hookup With Pa System And Along With Auto Dialer Facility Etc. As Required. (Approved Makes : Apollo/ Autronoca (Utc)/ Edwards (Utc)/ Siemens/ Bosch/ Notifire/ System Sensor/ Morley Ias/ Group4/ Mather & Platt/ Minimax). , Supply, Installation, Testing & Commissioning Of Ul / En Listed (Latest Version) Modular Microprocessor Based Expandable Intellegent Addressable Type Fire Alarm Control Panel Of Following Loops, With Minimum 320 Character Graphics / Lcd Display With Touch Screen Or Other Keypad And Minimum 4000 Events History Log In The Non Volatile Memory (Eprom) ,The Panel Should Be Equiped With Loop Capacity To Take Minimum 240 Intellegent Addressable Detectors/ Devices (In Any Combination ) In One Loop. Four Access Levels, Capable Of Taking Protocol Devices, Graphical Display, Sufficient Numbers Of Programmable Relay Controls For Controlling Ventilation Fan, Fire Pump Room, Monitoring Of Fire Sprinkler And Fire Hydrant Pump, 230 Volts, 50 Hz Ac Power Supply, Automatic Battery Charger, 24 Volts Sealed Maintenance Free Lead Acid Batteries Sufficient For 2 Hours Normal Working And Then Be Capable Of Operating The System For 30 Minutes During An Emergency / Fault Conditions Along With Battery Stand As Required. The Panel Shall Have Facility For Seamless Integration With Pa System (For Giving Triger Signal To Start Pre-Recorded Digital Voice Evacuation From Pa System In Case Of Fire ). The Panel Shall Be Compatible For Building Management System With Open Protocol Bacnet / Modbus Etc. As Per Specification, Complete As Required.(Approved Makes : Apollo/ Autronoca (Utc)/ Edwards (Utc)/ Siemens/ Bosch/ Notifire/ System Sensor/ Morley Ias/ Group4/ Mather & Platt/ Minimax). , Supplying & Laying Of 2X1.5 Sqmm Fire Survival Armouredcable, 600/1000V Rated With Annealed Copper Conductorhaving Glass Mica Fire Barrier Tape Covered By An Extrudedlayer Of Cross Linkable Ethylene Propylene Rubber (Epr)Insulation And Lszh Inner Bedding, Steel Wire Armouring &Lszh Outer Sheath Complete As Required.(Approved Makes : Cmi/ Kei/ Bonton/ Polycab/Batra Henlay/ Rr Cable/ Warexham). , Supply Of 63Mm Dia., 15Mtr. Long Rrl Hose Pipe (Isi Marked) With Necessary Male And Female Gun Metal / Ss Couplings Duly Binded With Gi Wire, Rivets Etc. Conforming To Is- 636 (Type-A) Complete As Required.(Approved Makes : Fireshield/Minimax/Newage/Safex). , Supply Of Standard Short Sized Branch Pipe Constructed From Ss Material Of 63Mm Dia.And Be Complete With Male Instantaneous Spring Lock Type Coupling For Connection To The End Of Hose Pipe,Externally Threaded To Receive Nozzle,Conforming To Is:903 Etc. Complete As Required.(Approved Makes : Fireshield/Minimax/Newage/Safex). , Supply Of Nozzle,20Mm Inner Diamter,Made Of Ss,Screw Threads At The Inlet Connection To Match With The Threading Of 63Mm Dia Branch Pipe With Inlet End Of Hexagonal Head To Facilitate Screwing Conforming To Is 903 Etc. As Required.(Approved Makes : Fireshield/Minimax/Newage/Safex).

BOQ

Sl. No. Item TitleItem Description
1Annual Maintenance Contract of Fire Hydrant including all pumps, panels, cables, piping , Hydrants etc. , intelligent type analogue addressable Fire Alarm system and Sprinkler system including all pumps, panels, cables, piping, sprinklers etc. at Aurangabad Airport for all preventive maintenance and checks as per manufacturers manual including attending to complaints/ Faults/ break down and taking rectification action, ensuring serviceability/ satisfactory working conditions of the system, maintenance of all records, documentation etc. as per the detailed specifications, terms & conditions covered under this contract on all days including sundays and holidays as per requirements of AAI.Annual Maintenance Contract of Fire Hydrant including all pumps, panels, cables, piping , Hydrants etc. , intelligent type analogue addressable Fire Alarm system and Sprinkler system including all pumps, panels, cables, piping, sprinklers etc. at Aurangabad Airport for all preventive maintenance and checks as per manufacturers manual including attending to complaints/ Faults/ break down and taking rectification action, ensuring serviceability/ satisfactory working conditions of the system, maintenance of all records, documentation etc. as per the detailed specifications, terms & conditions covered under this contract on all days including sundays and holidays as per requirements of AAI.
2Annual maintenance contract of Kirloskar make DG pump set (with specification mentioned under (A)) i/c engine control panel and other accessories of DG pump set.Job includes monthly visits for carrying out preventive maintenance, attending any number of breakdown calls when required, carrying out \\"B\\" and \\"C\\" check, minor repairs etc. as per manufacturer's recommendations / standard practice and as per the scope of work, complete as required. A) Engine type - 6R1080, Rating - 79 hp, RPM - 1500, governing class - M2.Annual maintenance contract of Kirloskar make DG pump set (with specification mentioned under (A)) i/c engine control panel and other accessories of DG pump set.Job includes monthly visits for carrying out preventive maintenance, attending any number of breakdown calls when required, carrying out \\"B\\" and \\"C\\" check, minor repairs etc. as per manufacturer's recommendations / standard practice and as per the scope of work, complete as required. A) Engine type - 6R1080, Rating - 79 hp, RPM - 1500, governing class - M2.
3Supplying, installation, testing & commissioning of Conventional Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS).Supplying, installation, testing & commissioning of Conventional Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS).
4Supplying, installation, testing & commissioning of addressable Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required. (Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS).Supplying, installation, testing & commissioning of addressable Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required. (Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS).
5Supplying, installation, testing & commissioning of Conventional Multi Sensor detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS).Supplying, installation, testing & commissioning of Conventional Multi Sensor detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS).
6Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications ,complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors)Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications ,complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors)
7Supplying, installation, testing & commissioning of conventional manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc.complying to relevant IS etc. as required.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX).Supplying, installation, testing & commissioning of conventional manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc.complying to relevant IS etc. as required.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX).
8Supplying, installation, testing & commissioning of conventional response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. complying to relevant IS etc. as required. (Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX).Supplying, installation, testing & commissioning of conventional response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. complying to relevant IS etc. as required. (Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX).
9Supplying, installation, testing & commissioning fire alarmsounder with facility to make announcement, mounted in M.S.box (16 SWG) with hinged cover plate & suitable for operationwith amplifier i/c line matching transformer etc. complete asrequired.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX).Supplying, installation, testing & commissioning fire alarmsounder with facility to make announcement, mounted in M.S.box (16 SWG) with hinged cover plate & suitable for operationwith amplifier i/c line matching transformer etc. complete asrequired.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX).
10Supplying, installation, testing & commissioning of conventional fire alarm panel , 16 X 2 dotmatrix LCD display, suitable for eight zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all otherstandard facilities as per IS:2189, complying relevant national fire alarm code for local fire alarm system with mimic diagram for allarea/zone covered, complete with all connections. The panel shall have input of 240 volts AC power supply, automatic battery charger, 24 volts, 2 X 12 volts, 12 Ah sealed lead acid maintenance free batteries sufficient for 24 hours normal power backup & working, interconnections. The panel shall be UL listed & FM approved and shall be hookup with PA system and along with auto dialer facility etc. as required. (Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX).Supplying, installation, testing & commissioning of conventional fire alarm panel , 16 X 2 dotmatrix LCD display, suitable for eight zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all otherstandard facilities as per IS:2189, complying relevant national fire alarm code for local fire alarm system with mimic diagram for allarea/zone covered, complete with all connections. The panel shall have input of 240 volts AC power supply, automatic battery charger, 24 volts, 2 X 12 volts, 12 Ah sealed lead acid maintenance free batteries sufficient for 24 hours normal power backup & working, interconnections. The panel shall be UL listed & FM approved and shall be hookup with PA system and along with auto dialer facility etc. as required. (Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX).
11Supply, Installation, Testing & Commissioning of UL / EN listed (latest version) Modular Microprocessor based expandable intellegent Addressable Type Fire Alarm Control Panel of following loops, with minimum 320 character graphics / LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM) ,The panel should be equiped with loop capacity to take minimum 240 intellegent addressable detectors/ devices (In any combination ) in one loop. Four access levels, capable of taking Protocol Devices, Graphical Display, sufficient numbers of programmable relay controls for controlling ventilation fan, fire pump room, monitoring of fire sprinkler and fire hydrant pump, 230 volts, 50 Hz AC power supply, automatic battery charger, 24 volts sealed maintenance free lead acid batteries sufficient for 2 hours normal working and then be capable of operating the system for 30 minutes during an emergency / fault conditions along with battery stand as required. The panel shall have facility for seamless integration with PA system (For Giving triger Signal to Start pre-recorded Digital Voice Evacuation from PA system in case of fire ). The panel shall be compatible for Building Management System with open protocol BACNET / MODBUS etc. as per specification, complete as required.(Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX).Supply, Installation, Testing & Commissioning of UL / EN listed (latest version) Modular Microprocessor based expandable intellegent Addressable Type Fire Alarm Control Panel of following loops, with minimum 320 character graphics / LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM) ,The panel should be equiped with loop capacity to take minimum 240 intellegent addressable detectors/ devices (In any combination ) in one loop. Four access levels, capable of taking Protocol Devices, Graphical Display, sufficient numbers of programmable relay controls for controlling ventilation fan, fire pump room, monitoring of fire sprinkler and fire hydrant pump, 230 volts, 50 Hz AC power supply, automatic battery charger, 24 volts sealed maintenance free lead acid batteries sufficient for 2 hours normal working and then be capable of operating the system for 30 minutes during an emergency / fault conditions along with battery stand as required. The panel shall have facility for seamless integration with PA system (For Giving triger Signal to Start pre-recorded Digital Voice Evacuation from PA system in case of fire ). The panel shall be compatible for Building Management System with open protocol BACNET / MODBUS etc. as per specification, complete as required.(Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX).
12Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring &LSZH outer sheath complete as required.(Approved Makes : CMI/ KEI/ BONTON/ POLYCAB/BATRA HENLAY/ RR CABLE/ WAREXHAM).Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring &LSZH outer sheath complete as required.(Approved Makes : CMI/ KEI/ BONTON/ POLYCAB/BATRA HENLAY/ RR CABLE/ WAREXHAM).
13Supply of 63mm dia., 15mtr. long RRL hose pipe (ISI Marked) with necessary male and female gun metal / SS couplings duly binded with GI wire, rivets etc. conforming to IS- 636 (Type-A) complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX).Supply of 63mm dia., 15mtr. long RRL hose pipe (ISI Marked) with necessary male and female gun metal / SS couplings duly binded with GI wire, rivets etc. conforming to IS- 636 (Type-A) complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX).
14Supply of standard short sized branch pipe constructed from SS material of 63mm dia.and be complete with male instantaneous spring lock type coupling for connection to the end of hose pipe,Externally threaded to receive nozzle,conforming to IS:903 etc. complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX).Supply of standard short sized branch pipe constructed from SS material of 63mm dia.and be complete with male instantaneous spring lock type coupling for connection to the end of hose pipe,Externally threaded to receive nozzle,conforming to IS:903 etc. complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX).
15supply of nozzle,20mm inner diamter,made of SS,screw threads at the inlet connection to match with the threading of 63mm dia branch pipe with inlet end of hexagonal head to facilitate screwing conforming to IS 903 etc. as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX).supply of nozzle,20mm inner diamter,made of SS,screw threads at the inlet connection to match with the threading of 63mm dia branch pipe with inlet end of hexagonal head to facilitate screwing conforming to IS 903 etc. as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX).

AI Tender Summary

OUR REF NO 56709037
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 17.13 Lakhs
LAST DATE 18-08-2026
Authority
Authority Name Airports Authority Of India
Work Description Bids Are invited for Manpower Outsourcing Services - Minimum Wage - Skilled; High School; Others , Manpower Outsourcing Services - Minimum Wage - Unskilled; High School; Others - Annual Maintenance Contract Of Fire Hydrant Including All Pumps, Panels, Cables, Piping , Hydrants Etc. , Intelligent Type Analogue Addressable Fire Alarm System And Sprinkler System Including All Pumps, Panels, Cables, Piping, Sprinklers Etc. At Aurangabad Airport For All Preventive Maintenance And Checks As Per Manufacturers Manual Including Attending To Complaints/ Faults/ Break Down And Taking Rectification Action, Ensuring Serviceability/ Satisfactory Working Conditions Of The System, Maintenance Of All Records, Documentation Etc. As Per The Detailed Specifications, Terms & Conditions Covered Under This Contract On All Days Including Sundays And Holidays As Per Requirements Of Aai. , Annual Maintenance Contract Of Kirloskar Make Dg Pump Set (With Specification Mentioned Under (A)) I/C Engine Control Panel And Other Accessories Of Dg Pump Set.Job Includes Monthly Visits For Carrying Out Preventive Maintenance, Attending Any Number Of Breakdown Calls When Required, Carrying Out B And C Check, Minor Repairs Etc. As Per Manufacturers Recommendations / Standard Practice And As Per The Scope Of Work, Complete As Required. A) Engine Type - 6R1080, Rating - 79 Hp, Rpm - 1500, Governing Class - M2. , Supplying, Installation, Testing & Commissioning Of Conventional Photo Electric Smoke Detector With Builtin Led And Mounting Base Complete With All Connections Complying To Relevant Is Etc. As Required.(Approved Makes : Apollo/ Edwards (Utc)/ Siemens/ Bosch/ Notifire/ System Sensor/ Morly Ias). , Supplying, Installation, Testing & Commissioning Of Addressable Photo Electric Smoke Detector With Builtin Led And Mounting Base Complete With All Connections Complying To Relevant Is Etc. As Required. (Approved Makes : Apollo/ Edwards (Utc)/ Siemens/ Bosch/ Notifire/ System Sensor/ Morly Ias). , Supplying, Installation, Testing & Commissioning Of Conventional Multi Sensor Detector With Builtin Led And Mounting Base Complete With All Connections Complying To Relevant Is Etc. As Required.(Approved Makes : Apollo/ Edwards (Utc)/ Siemens/ Bosch/ Notifire/ System Sensor/ Morly Ias). , Supply, Installation, Testing & Commissioning Of Ul / En Listed (Latest Version) Intelligent Addressable Multi Criteria Detector {Smoke + Heat } With Inbuilt Fault Isolator / Isolator Base And With Unique Optical Sensing Chamber, Visible Led, Fully Coated Circuit Board, Superior Rf / Transient Protection Suitable For 2 Wires Loop Connection, Complete With Plug Into Common Separate Base & Housing Constructed Of Lexan (Or Polycarbonate) Complete With Connections Etc. As Required And To Be Installed Below / Above False Ceiling Roof And Concealed Space And As Per Enclosed Specifications ,Complete As Required. (Cost Of Plug In Common Base Shall Deemed To Be Included In Cost Of Detectors) , Supplying, Installation, Testing & Commissioning Of Conventional Manual Call Box Of Abs Type In Surface/Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc.Complying To Relevant Is Etc. As Required.(Approved Makes : Apollo/Edwards (Utc)/ Siemens/ Bosch/ Notifire/ Morley Ias/System Sensor/Group4/ Minimax). , Supplying, Installation, Testing & Commissioning Of Conventional Response Indicator On Surface/Recess Ms Box Having Two Leds Metallic Cover Complete With All Connections Etc. Complying To Relevant Is Etc. As Required. (Approved Makes : Apollo/Edwards (Utc)/ Siemens/ Bosch/ Notifire/ Morley Ias/System Sensor/Group4/ Minimax). , Supplying, Installation, Testing & Commissioning Fire Alarmsounder With Facility To Make Announcement, Mounted In M.S.Box (16 Swg) With Hinged Cover Plate & Suitable For Operationwith Lifier I/C Line Matching Transformer Etc. Complete Asrequired.(Approved Makes : Apollo/Edwards (Utc)/ Siemens/ Bosch/ Notifire/ Morley Ias/System Sensor/Group4/ Minimax). , Supplying, Installation, Testing & Commissioning Of Conventional Fire Alarm Panel , 16 X 2 Dotmatrix Lcd Display, Suitable For Eight Zones, Complete With Visual Indications For Short Circuit Fault, Open Circuit Fault, Fire Condition And All Otherstandard Facilities As Per Is:2189, Complying Relevant National Fire Alarm Code For Local Fire Alarm System With Mimic Diagram For Allarea/Zone Covered, Complete With All Connections. The Panel Shall Have Input Of 240 Volts Ac Power Supply, Automatic Battery Charger, 24 Volts, 2 X 12 Volts, 12 Ah Sealed Lead Acid Maintenance Free Batteries Sufficient For 24 Hours Normal Power Backup & Working, Interconnections. The Panel Shall Be Ul Listed & Fm Approved And Shall Be Hookup With Pa System And Along With Auto Dialer Facility Etc. As Required. (Approved Makes : Apollo/ Autronoca (Utc)/ Edwards (Utc)/ Siemens/ Bosch/ Notifire/ System Sensor/ Morley Ias/ Group4/ Mather & Platt/ Minimax). , Supply, Installation, Testing & Commissioning Of Ul / En Listed (Latest Version) Modular Microprocessor Based Expandable Intellegent Addressable Type Fire Alarm Control Panel Of Following Loops, With Minimum 320 Character Graphics / Lcd Display With Touch Screen Or Other Keypad And Minimum 4000 Events History Log In The Non Volatile Memory (Eprom) ,The Panel Should Be Equiped With Loop Capacity To Take Minimum 240 Intellegent Addressable Detectors/ Devices (In Any Combination ) In One Loop. Four Access Levels, Capable Of Taking Protocol Devices, Graphical Display, Sufficient Numbers Of Programmable Relay Controls For Controlling Ventilation Fan, Fire Pump Room, Monitoring Of Fire Sprinkler And Fire Hydrant Pump, 230 Volts, 50 Hz Ac Power Supply, Automatic Battery Charger, 24 Volts Sealed Maintenance Free Lead Acid Batteries Sufficient For 2 Hours Normal Working And Then Be Capable Of Operating The System For 30 Minutes During An Emergency / Fault Conditions Along With Battery Stand As Required. The Panel Shall Have Facility For Seamless Integration With Pa System (For Giving Triger Signal To Start Pre-Recorded Digital Voice Evacuation From Pa System In Case Of Fire ). The Panel Shall Be Compatible For Building Management System With Open Protocol Bacnet / Modbus Etc. As Per Specification, Complete As Required.(Approved Makes : Apollo/ Autronoca (Utc)/ Edwards (Utc)/ Siemens/ Bosch/ Notifire/ System Sensor/ Morley Ias/ Group4/ Mather & Platt/ Minimax). , Supplying & Laying Of 2X1.5 Sqmm Fire Survival Armouredcable, 600/1000V Rated With Annealed Copper Conductorhaving Glass Mica Fire Barrier Tape Covered By An Extrudedlayer Of Cross Linkable Ethylene Propylene Rubber (Epr)Insulation And Lszh Inner Bedding, Steel Wire Armouring &Lszh Outer Sheath Complete As Required.(Approved Makes : Cmi/ Kei/ Bonton/ Polycab/Batra Henlay/ Rr Cable/ Warexham). , Supply Of 63Mm Dia., 15Mtr. Long Rrl Hose Pipe (Isi Marked) With Necessary Male And Female Gun Metal / Ss Couplings Duly Binded With Gi Wire, Rivets Etc. Conforming To Is- 636 (Type-A) Complete As Required.(Approved Makes : Fireshield/Minimax/Newage/Safex). , Supply Of Standard Short Sized Branch Pipe Constructed From Ss Material Of 63Mm Dia.And Be Complete With Male Instantaneous Spring Lock Type Coupling For Connection To The End Of Hose Pipe,Externally Threaded To Receive Nozzle,Conforming To Is:903 Etc. Complete As Required.(Approved Makes : Fireshield/Minimax/Newage/Safex). , Supply Of Nozzle,20Mm Inner Diamter,Made Of Ss,Screw Threads At The Inlet Connection To Match With The Threading Of 63Mm Dia Branch Pipe With Inlet End Of Hexagonal Head To Facilitate Screwing Conforming To Is 903 Etc. As Required.(Approved Makes : Fireshield/Minimax/Newage/Safex).
Basic Detail
Tender No GEM/2026/B/7811107
Bidding Type Tender
Location
City Diu
State Daman and Diu
Key Dates
Publish Date 28 Jul 2026
Submission Date 18 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 17.13 Lakhs
Tender Fee Ref. Documents
EMD 51393
Exemption Not Available
Document List
34b9807c-b867-4f5b-8af0-a0d4998f671f.pdf
1784570867.xlsx
1784571521.pdf
1785233002.pdf
atc_4b664b66-a500-4b04-89f71785233139247_tech-diu-1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
pdf

34b9807c-b867-4f5b-8af0-a0d4998f671f.pdf

xlsx

1784570867.xlsx

pdf

1784571521.pdf

pdf

1785233002.pdf

pdf

atc_4b664b66-a500-4b04-89f71785233139247_tech-diu-1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders