Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #56702112

Tender For Repair To Manholes Sewage Lines And Misc Repairs Connected Works In Smqs Sector 47 And 28 At 3 Brd Under Ge (Af) Mc Chandigarh

Issued by Statutory Bodies & Commissions/Committees · Chandigarh, Chandigarh
Tender Value
39.99 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
0 days left
EMD
79980
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair To Manholes Sewage Lines And Misc Repairs Connected Works In Smqs Sector 47 And 28 At 3 Brd Under Ge (Af) Mc Chandigarh

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-Aug-2026

BOQ

Name of Work:- REPAIR TO MANHOLES SEWAGE LINES AND MISC REPAIRS CONNECTED WORKS IN SMQS SECTOR 47 AND 28 AT 3 BRD UNDER GE (AF) MC CHANDIGARH
Sl. No. Item Description
1Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified and directed by the Engineer -In –charge
2Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth in soils, complete all as specified and directed by the Engineer -In –charge
3Removal of excavated material to a distance exc 1.50Km but n exc 5 km and complete all as specified and directed by the Engineer -In –charge
4Demolition of brick work built in cement mortar in any position and in any location complete all as specified and directed by the Engineer -In –charge
5M&L brick work with sub Class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 in any location, complete all as specified and directed by the Engineer -In –charge
6All as per item No 5 here-in-before but except bricks.
7Taking down cement plaster on any surfaces including raking out joints, hacking for key,scrubbibg down with water etc. complete all as specified & directed by Engr-in-Charge.
8M & L for Rendering 15 mm thick on brick /concrete surfces in Cement Mortar 1:4 finished even & smooth without using extra cement & with/without WPC, complete all as specified & directed by Engr-in-Charge. NOTE:- WPC will be paid separately.
9M&L for preparation of new plaster surface applying two coats of cement base paint on walls complete all as specified and directed by Engr-in -charge
10Demolition of 150 mm bore SGSW/NP2 drain pipes including PCC haunching and bedding jointed in cement mortar and taking out including removal, complete all as specified and directed by the Engineer -In –charge
11Demolition of 200 mm bore SGSW/NP2 drain pipes including PCC haunching and bedding jointed in cement mortar and taking out including removal, complete all as specified and directed by the Engineer -In –charge
12S&F Plain cement concrete type C-2, 1:3:6 using 40mm graded crushed stone aggregate as in concrete bed to drain pipes for 150mm bore pipe including forming cradles, (Thickness & width as per SSR) complete all as specified and directed by the Engineer -In –charge
13S&F Plain cement concrete type C-2, 1:3:6 using 40mm graded crushed stone aggregate as in concrete bed to drain pipes for 200mm bore pipe including forming cradles, (Thickness & width as per SSR) complete all as specified and directed by the Engineer -In –charge
14S&F 150mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars in repair complete all as specified and directed by Engr-in-Charge
15S&F 200mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars in repair complete all as specified and directed by Engr-in-Charge
16S&F for providing, lowering and laying HDPE DWCPE (SN8) Pipes 150mm bore as per IS 16098 part II for nonpressure Underground drainage and Sewerage applications with and including cost of special O rubber ring couplers etc. , Laid in trenches on concrete bed to level/ gradient jointing and testing with appropriate class fittings as per manufacturer's instructions including jointing accessories and fittings complete, all as specified and directed by Engineer-in-Charge.
17S&F for providing, lowering and laying HDPE DWCPE (SN8) Pipes 200mm bore as per IS 16098 part II for nonpressure Underground drainage and Sewerage applications with and including cost of special O rubber ring couplers etc. , Laid in trenches on concrete bed to level/ gradient jointing and testing with appropriate class fittings as per manufacturer's instructions including jointing accessories and fittings complete, all as specified and directed by Engineer-in-Charge.
18M&L Plain cement concrete type C-2, 1:3:6 using 40mm graded crushed stone aggregate as in concrete bed including packing under & haunching against sides of pipes after the pipe are laid and tested for 150mm complete all as specified and directed by the Engineer -In –charge
19M&L Plain cement concrete type C-2, 1:3:6 using 40mm graded crushed stone aggregate as in concrete bed including packing under & haunching against sides of pipes after the pipe are laid and tested for 200mm complete all as specified and directed by the Engineer -In –charge
20Demolition of lime concrete / lean concrete /Brick bats etc. from sunken slab portion exc. 15 cm thick but above ground floors, complete all as specified and directed by Engineer-in-charge including removal of demolished material from MD land debrish away from site to a disignated point by local administration or a distance up to 1.5 km from site complete all as specified and directed by Engr-in-charge
21M & L for 25 mm thick cement concrete (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregate as in flooring laid in slope complete all as specified and directed by Engineer- in-charge.
22M&L lean concrete type E-2 (1:5:10) using 40mm graded crushed stone aggregate as in sunken portion complete all as specified and directed by Engineer-in-charge.
23M & L for 40mm GI Spout pipe for sunken work complete all as specified and directed by Engineer-in-charge.
24M&L for providing water proofing treatment of sunken portion of WCs, bathroom etc. by applying cement slurry mixed with Acrylic based polymer modified cementitious composite compound coating of make asapproval in Technical Instruction 5/2003 by adding: (a) 15mm thick plaster (1:4) cement sand mortar with integral water proofing compound 2% by weight of cement on floor and wall / beam , finishing the surface even and smooth without using extra cement. The surface shall then be cured and allowed to dry. (Note: Water proofing compound shall be measured and paid separately). (b) First layer of slurry of cement @0.5 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.25 kg/sqm. This layer will be allowed to air cure for 4 hrs. (c) Second layer of slurry of cement @0.25 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.15 kg/sqm. This layer will be allowed to air cure for 4 hrs followed with water curing for 48 hrs. complete all as specified and directed by Engineer-in-charge.NOTE : Floor area of the sunken slab shall be measured only.Make of Acrylic based polymer modified cementitious compound -Fosroc ( Brushbond) /Sika (Sikatop-100)/Pidilite
25Supply only water proofing compound ISI marked complete all as specified and directed by Engr-in-Charge.
26S&F in repair 100 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall , laid in trenches or in floors, complete all as specified and directed by Engr-in-charge.
27All as per item No. 26 here-in-before but 75 mm dia
28Fixing only in repair 100 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall , laid in trenches or in floors, after necessary cleaning complete all as specified and directed by Engr-in-charge.
29Fixing only in repair 75 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall , laid in trenches or in floors, after necessary cleaning complete all as specified and directed by Engr-in-charge.
30S&F 100 mm cast iron bends complete all as specified and as directed.
31All as per item No. 30 here-in-before but 75 mm dia
32S&F Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallelbranches 100 mm dia complete all as specified and directed by Engr-in-charge.
33S&F Branch pieces, single (equal or unequal) ,ordinary or inverted (spigot or socket type) or with parallelbranches 75 mm dia complete all as specified and directed by Engr-in-charge.
34S&F in repairs 75 mm dia cast iron Floor Trap/Nahani Trap ,with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engr-in-charge.
35S&F in repairs 100 mm dia cast iron Floor Trap/Nahani Trap ,with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engr-in-charge.
36Fixing only in repair 100 mm cast iron bends/Tee/cowls after necessary cleaning complete all as specified and directed by Engr-in-charge.
37All as per item No. 36 here-in-before but 75 mm dia
38S&F Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays including bolts & nuts and securing ends of stay to wall for 100mm bore CI pipes complete all as specified and directed by Engineer-in-charge.
39M&L for, Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm / 450X 350X 7mm thick as in skirting, dados, risers to steps, etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles ,10 mm thick for wall finished in Cement Mortar 1:4 , including dismantaling floor hearth or wall tiling including cement mortar bedding ( but not backing ) removal of rubbish off the premises debrish away from site to a disignated point by local administration or a distance up to 1.5 km from site complete complete all as specified and directed by Engr-in-charge.
40M&L for Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 thick screed bed in Cement Mortar 1:6 and dismantling of existing tiles and rubbish off the premises complete all as specified and directed by Engr-in-charge.
41S&F in repairs Vitreous china squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rest, including connecting and necessary provision of lime concrete complete all as specified and directed by Engr-in-Charge.
42S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. & plastic water closet seat, white closed pattern with flat bottom, and cover and mild steel chromium plated hinging device in repair complete all as specified and directed by Engr-in-charge.
43S&F Factory made RCC (M 40 Grade) manhole covers slab 75mm thick with and including frame with hot dip galvanized hooks designation LD 5.5 clear opening of frame (Manufactures permanent identification marks to be visible even after fixing complete) (Size-1.00m x 0.50m)Make : VENUS/HARIOM TILES AND PAVER/MOHINDRA & SV RCC
44S&F Factory made RCC (M 40 Grade) manhole covers slab 75mm thick with and including frame with hot dip galvanized hooks designation LD 5.5 clear opening of frame (Manufactures permanent identification marks to be visible even after fixing complete) (Size-0.750m x 0.750m)Make : VENUS/HARIOM TILES AND PAVER/MOHINDRA & SV RCC
45S&F Factory made RCC (M 40 Grade) manhole covers slab 75mm thick with and including frame with hot dip galvanized hooks designation LD 5.5 clear opening of frame (Manufactures permanent identification marks to be visible even after fixing complete) (Size-0.45m x 0.45m)Make : VENUS/HARIOM TILES AND PAVER/MOHINDRA & SV RCC
46Cutting into existing manhole for connecting new drain, making good to pipes and rendering cutting out existing benching for and forming branch channel (½ round of ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150/200 mm bore pipe complete all as specified and directed by the Engineer -In –charge
47Demolition of cement concrete (unreinforced) below or above ground level n exc 15 cm thick complete all as specified and directed by the Engineer-in-Charge.
48M & L PCC 1:4:8 type B-2, 75 mm thick (40 mm graded crushed stone aggregate ) as in sub base, floor complete all as specified and directed by the Engineer -In –charge(PCC shall be laid in alternate bays as per directed)
49M & L 40 mm thick PCC 1:2:4 type D-2, (20 mm graded crushed stone aggregate) as in floor finishing cement concre surface even and smooth without using extra cement complete all as specified and directed by the Engineer -In –charge
50M&L in repairs machine pressed pre polished precast rubberised concrete interlocking colour paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness M-40 grade with grey cement and pigment complete all as specified and directed.
51All as per Item No. 50 here-in-before but except paver block (paver block obtained from Srl item No. 50 shall be reused).
52M&L 25 mm sand cushioning for interlocking tiles including well rammed and consolidation all as per direction by Engr-in- Charge.
53M&L for cement concrete (1:2:4), type B-1, using 20mm graded mechanically crushed stone aggregate as in coping, bed block benching, kerbs, mud stop, rounded or chamferred on edges including necessary form work/moulds complete all as specified and directed by the Engineer -In –charge
54S&F in repair110mm PVC (SWR) pipes single socket in any length with rubber ring joints, laid in trenches, floors or laid in sunken floors, walls including GI clamps of approved shape and size approved by GE at any height, any location including scaffolding complete all as specified and directed by Engr-in-charge.
55S&F in repair 110 mm PVC(SWR) bends,branch piece or similar fitting as required to make the system functional complete all as specified and directed by Engr-in-charge..
56S&F in repair 75mm PVC (SWR) pipes single socket in any length with rubber ring joints, laid in trenches, floors or laid in sunken floors, walls including GI clamps of approved shape and size approved by GE at any height, any location including scaffolding complete all as specified and directed by Engr-in-charge.
57S&F in repair 75 mm PVC(SWR) bends,branch piece or similar fitting as reqd to make the system functional complete all as specified and directed by Engr-in-charge..
58M&L for repair of Gully trap of size 150x150 mm type 'P' including necessary brick work, plaster, PCC all as required at site complete all as specified and directed by Engr-in-charge..
59Cleaning & maintenance of solid/liquid mud/any type of solid content including mud, brick bats, empty containers of any type, rags, polythene or any similar items deposited in underground sewage lines at any depth upto 2.5 metres including manholes/inspection chambers of any size and any depth, manualy in Sector 47 & 28 area, under 3BRD AF Station Chandigarh. Bottom surface of manholes/inspection chambers & sewage lines should be visible after cleaning process. Sludge/sludge water/any type of waste recovered from sewage lines/manholes/inspection chambers shall be disposed off at authorized dumping site declared by local administration outside Ministry of defence land complete all as specified and as directed by the Engineer-in-Charge.
60Cleaning & maintenance of solid/liquid mud/any type of solid content including mud, brick bats, empty containers of any type, rags, polythene or any similar items deposited in underground sewage lines at any depth upto 2.5 metres including manholes/inspection chambers of any size and any depth, using SUPER SUCTION MACHINE TRUCK MOUNTED HAVING SUCTION CAPACITY 1000 TO 4000 CUM/HRS, JETTING PUMP WITH WORKING PRESSURE AT LEAST 120 BAR having facilities of high pressure water thermoplastic fiber braided water jetting hose and through conical/round shape nozzler pipe in Sector 47 & 28 area, under 3BRD AF Station Chandigarh. Tractor mounted mechanical cleaning will not be accepted. Bottom surface of manholes/inspection chambers & sewage lines should be visible after cleaning process. Sludge/sludge water/any type of waste recovered from sewage lines/manholes/inspection chambers shall be disposed off at authorized dumping site declared by local administration outside Ministry of defence land complete all as specified and as directed by the Engineer-in-Charge.
61Note:- Lines once cleared will be maintained through out the period of the contract for free flow. If there is any blockage during the period of the contract, the same will be cleared without any extra cost by the contractor.(i) In case of any blockage is observed/found in any cleared line through super suction machine during the time period of contract and it becomes necessary to clear the sewage line again, the same shall be cleared through machine by the contractor without any extra cost to the department. The line shall be cleared by the contractor within 48hrs after intimation to the contractor. The rate quoted by the contractor against item No 01 above shall be deemed to be inclusive of clearance of line twice or more time as required during the whole contract period.
62Cleaning and clearing of bore underground sewage line from any type of trap including (WCs/Gully trap/floor traps/CI pipes/Nahani traps / Bathrooms etc) to 1st manholes including trap & manhole of any depth by taking off manhole covers and re-fixing the same after cleaning of any description, underground and any depth by removing any type of blockage including de-silting and de-chocking Sludge/sludge water shall be disposed off at authorized dumping site declared by local administration outside MoD land distance exceeding 2Km but n.exc 2.5Km, complete all as specified and directed. Note:- (a) The contractor shall deploy minimum, 01 safaiwala & 01 helper (Total 02 people) alongwith T&P on regular basis to complaint cell/service centre of sector 47 under AGE B/R-II of GE (AF) MC Chandigarh located in Sector-47 daily between 0830 to 0900hrs (except on Sunday/Gazetted holidays). (b) The complaints shall be attended preferably on the same day and complaints slips duly signed by the user will be deposited back with JE(Civil) on the same day. Please Enable Macros to View BoQ information
63Cleaning and clearing of bore underground sewage line from any type of trap including (WCs/Gully trap/floor traps/CI pipes/Nahani traps / Bathrooms etc) to 1st manholes including trap & manhole of any depth by taking off manhole covers and re-fixing the same after cleaning of any description, underground and any depth by removing any type of blockage including de-silting and de-chocking Sludge/sludge water shall be disposed off at authorized dumping site declared by local administration outside MoD land distance exceeding 2Km but n.exc 2.5Km, complete all as specified and directed. Note:- (a) The contractor shall deploy minimum, 01 safaiwala & 01 helper (Total 02 people) alongwith T&P on regular basis to complaint cell/service centre of sector 47 under AGE B/R-II of GE (AF) MC Chandigarh located in Sector-47 daily between 0830 to 0900hrs (except on Sunday/Gazetted holidays). (b) The complaints shall be attended preferably on the same day and complaints slips duly signed by the user will be deposited back with JE(Civil) on the same day. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56702112
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 39.99 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Manholes Sewage Lines And Misc Repairs Connected Works In Smqs Sector 47 And 28 At 3 Brd Under Ge (Af) Mc Chandigarh
Basic Detail
Tender No GE (AF) MC/CHD/T-48/2026-27
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 18 Aug 2026
Submission Date 25 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 39.99 Lakhs
Tender Fee 500
EMD 79980
Exemption Available
Document List
BOQ_875302.xls
f1ceb48f-80d1-484e-ba18-4f3dee8ced8d.html
TenderDocument48.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_875302.xls

html

f1ceb48f-80d1-484e-ba18-4f3dee8ced8d.html

pdf

TenderDocument48.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders