Tender For Special Repairs To Lt Feeder Pillar Boxes At Bldg No. P-367 (Mes Service Centre) And Certain Locations And Other Sanction Work At installation Valsura, Jamnagar
Tender Value
28 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
19 days left
EMD
56000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Lt Feeder Pillar Boxes At Bldg No. P-367 (Mes Service Centre) And Certain Locations And Other Sanction Work At installation Valsura, Jamnagar
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed. |
| 2 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and as directed. |
| 3 | Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. |
| 4 | M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed. |
| 5 | M&L for filling approved dry river sand for cushioning and cover for protection of under ground electric cable in trenches 8 cm before laying cable and 15 cm deep over the cable and punning to 18 cm total thickness complete all as specified and as directed. Notes :-(i) Approved dry sand free from vegetations, grass and other deleterious substances shall be used.(ii) For the purpose of payment, only punned thickness shall be measured. |
| 6 | Taking down carefully old existing LT PCC Cable Cover of Class LV of any type & size complete all as specified & as directed. |
| 7 | Laying only LT PCC cable covers of any type & size for protection of UG LT electric cables in trenches, obtained serviceable from serial item No. 6 here-in-above, complete all as specified & as directed. |
| 8 | Supply and laying un-reinforced precast concrete cable cover, Class LV, Type-1, Flat, size 250mm x 150mm x 40mm for protection of underground electric cable in trenches complete all as specified and as directed. |
| 9 | M&L for Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed.Note :- Excavation & earthwork shall be measured & paid for separately. |
| 10 | All as per serial item No. 9 here-in-above, but 80mm bore. |
| 11 | Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 240 sqmm 3½ Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed.Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 12 | All as per serial item No. 11 here-in-above, but cross-sectional area 120 Sqmm 3½ Core. |
| 13 | All as per serial item No. 11 here-in-above, but cross-sectional area 95 Sqmm 3½ Core. |
| 14 | All as per serial item No. 11 here-in-above, but cross-sectional area 70 Sqmm 3½ Core. |
| 15 | All as per serial item No. 11 here-in-above, but cross-sectional area 50 Sqmm 3½ Core. |
| 16 | All as per serial item No. 11 here-in-above, but cross-sectional area 35 Sqmm 3½ Core. |
| 17 | All as per serial item No. 11 here-in-above, but cross-sectional area 25 Sqmm 3½ Core. |
| 18 | All as per serial item No. 11 here-in-above, but cross-sectional area 10 Sqmm 4 Core. |
| 19 | M&L for cable jointing kit for 1100 V grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 2 to 4 core PVC/XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed. |
| 20 | M&L for cable jointing kit for 1100 V grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed. |
| 21 | All as per serial item No. 20 here-in-above, but size 70 Sqmm to 95 Sqmm. |
| 22 | All as per serial item No. 20 here-in-above, but size 120 Sqmm to 185 Sqmm. |
| 23 | All as per serial item No. 20 here-in-above, but size 240 Sqmm to 300 Sqmm. |
| 24 | Disconnecting, dismantling & taking down old unserviceable LT Panel Box of any size & capacity including all fixtures/accessories and Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new outdoor type LT Panel Box cubical type of suitable size (minimum depth 500mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 3.15 mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet, with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-55 with coloured insulation sleeve, rubber gasket, insulators, outdoor type, totally enclosed, weather, dust and vermin proof as per IS, Front & Rear opening with double door shutters having suitable aldrop bolt locking arrangement, with insulators, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including danger notice plate, necessary PCC 1:3:6 type C1 in foundation and frame made out of 65 x 65 x 6mm angle iron grouted at minimum 45cm above ground level and 30cm below ground level, comprising & including the following accessories complete all as specified and as directed :- description of item contd.... |
| 25 | Description of serial item No. 24 contd…(a) MCCB 160 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as incoming. Make: Legrand Cat Part No. 4200 97 or equivalent in makes mentioned in Appendix 'B' here-in-after(b) MCCB 100 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as outgoing. Make: Legrand Cat Part No. 4200 55 or equivalent in makes mentioned in Appendix 'B' here-in-after(c) MCCB 63 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No as outgoing. Make: Legrand Cat Part No. 4200 53 or equivalent in makes mentioned in Appendix 'B' here-in-after(d) MCB TPN 63 Amp, 10 kA, ‘C’ Curve, 415 Volt grade, AC, 50 Hz - 02 Nos. Make: Legrand Cat Part No. 4086 83 or equivalent in makes mentioned in Appendix 'B' here-in-after.description of item contd.... |
| 26 | Description of serial item No. 24 contd…(e) MCB TPN 32 Amp, 10 kA, ‘C’ Curve, 415 Volt grade, AC, 50 Hz - 01 No. Make: Legrand Cat Part No. 4086 80 or equivalent in makes mentioned in Appendix 'B' here-in-after.(f) MCB SPN 40 Amp, 10 kA, ‘C’ Curve, 240 Volt grade, AC, 50 Hz - 01 No. Make: Legrand Cat Part No. 4086 18 or equivalent in makes mentioned in Appendix 'B' here-in-after.(g) Multifunction Meter – 01 No. Make: L&T/ C&S/ Legrand/ SECURE or equivalent in makes mentioned in Appendix 'B' here-in-after. (h) Bus bar minimum 300 Amp aluminium with R/Y/B coloured for three Phases and 150 Amp for Neutral Black colour insulation sleeves - 01 Set(j) Indicator Set RYB, “LED” type (set of three) -01 Setdescription of item contd.... Please Enable Macros to View BoQ information |
| 27 | Description of serial item No. 24 contd…(e) MCB TPN 32 Amp, 10 kA, ‘C’ Curve, 415 Volt grade, AC, 50 Hz - 01 No. Make: Legrand Cat Part No. 4086 80 or equivalent in makes mentioned in Appendix 'B' here-in-after.(f) MCB SPN 40 Amp, 10 kA, ‘C’ Curve, 240 Volt grade, AC, 50 Hz - 01 No. Make: Legrand Cat Part No. 4086 18 or equivalent in makes mentioned in Appendix 'B' here-in-after.(g) Multifunction Meter – 01 No. Make: L&T/ C&S/ Legrand/ SECURE or equivalent in makes mentioned in Appendix 'B' here-in-after. (h) Bus bar minimum 300 Amp aluminium with R/Y/B coloured for three Phases and 150 Amp for Neutral Black colour insulation sleeves - 01 Set(j) Indicator Set RYB, “LED” type (set of three) -01 Setdescription of item contd.... Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender