Tender For Rrepair/Replacement Of Acb, Mccbs Incl Misc Items And Allied Works In Bhagat Line Area Under Age E/M Elect Supply At Ge(U)E/M Meerut Cantt.
Tender Value
49 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
18 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Meerut → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Rrepair/Replacement Of Acb, Mccbs Incl Misc Items And Allied Works In Bhagat Line Area Under Age E/M Elect Supply At Ge(U)E/M Meerut Cantt.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installing, errecting, testing and commissioning, factory made and tested LT Panel board with all accessories. LT Panel board, OUT DOOR type,over all dimension not less than 1.0 m(L)x0.5 m (W)x 1.2m(H),platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Aluminum busbars installed on porcelain / SMC insulators and all interconnection between main busbars as well as outgoing feeders shall be carried out with TPN Aluminum busbar of rating not less then 1.5 times rated capacity of individual out going feeders. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6mm thick angle iron frame work, bottom channel of size: 70x40x5 mm powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type, and fixing 2 Nos.danger notice plate with letter made of 1.6 mm thick mild steel sheet, vitreous enamelled of size 20x15 cm with , figures and conventional skull bones in signal red colour and fixed front & back door to LT panel etc with voltage and danger indiated in Hindi and English, with double door shutter and locking arrangement,internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 30 cm above the nearest ground level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 400 sqmm by drawing /digging out cable from loops in trenches/ ducts out side the Bldg inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size Aluminium lugs for terminal connections of cables, platform for panel, with PCC 1:4:8 type D2 with 40 mm graded crushed stone 15cm thick foundation, brick work in CM 1:6 with sub class\\"B\\" old size bricks ,rendering 15 mm thick CM 1:6 on exposed surface and 100 mm thick padding 1:3:6 type C1 using 20 mm graded crused stone aggreagate on top and grouting bolts for LT panel , All out going feeders shall be connected by cable through suitable size gland plate / glands.& The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and including taking down old LT panle any size. complete all as specified and as directed by Engr-in-Charge.Note :-(1) LT Panel Board Should be as per IS/ICF 61439 Part -1 & 2 Type(2) Test Certificate For 4000 APS With Breaking Capacty Not Less Than 65 KA Panel Builder Should Submit All Certificate As Per ICE 61439 Part I & II |
| 2 | (I) Incoming :-(i) Aluminum busbar, 4 Pole, 640 Amps (ii) MCCB 4P, 400A, 36 KA, with thermal magnetic/adjustable: O/L & S/C protection , ICS= 100% ICU = 01 Nos. (iii) Ammeter Digital type, CT operated 0-500A range, (with selector switch and CT) - 01 Set (iv) Volt Meter Digital type 0-500 V range, (With selector switch) - 01 No. (v) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set. |
| 3 | (II) Outgoing :-(i) MCCB 4P, 200A, 36 KA, with thermal magnetic/adjustable: O/L & S/C protection , ICS= 100% ICU = 02 Nos (ii) MCCB 4P, 125A, 25 KA, with thermal magnetic/adjustable: O/L & S/C protection , ICS= 100% ICU = 01 Nos. (iii) MCCB 4P, 63A, 16 KA, with thermal magnetic/ adjustable: O/L & S/C protection , ICS= 100% ICU = 01 Nos. |
| 4 | All as per Srl item No1 above, but with followings:- |
| 5 | (I) Incoming :-(i) Aluminum busbar, 4 Pole, 400 Amps (ii) MCCB 4P, 250A, 36 KA, with thermal magnetic/adjustable: O/L & S/C protection , ICS= 100% ICU = 01 Nos. (iii) Ammeter Digital type, CT operated 0-400A range, (with selector switch and CT) - 01 Set (iv) Volt Meter Digital type 0-400 V range, (With selector switch) - 01 No. (v) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set. |
| 6 | (II) Outgoing :-(i) MCCB 4P, 100A, 25 KA, with thermal magnetic/adjustable: O/L & S/C protection , ICS= 100% ICU = 02 Nos. (ii) MCCB 4P, 63A, 16 KA, with thermal magnetic/adjustable: O/L & S/C protection , ICS= 100% ICU = 03 Nos. |
| 7 | All as per Srl item No 1 above, but with followings:- |
| 8 | (I) Incoming :- (i) Aluminum busbar, 4 Pole, 400 Amps (ii) MCCB 4P, 250A, 36 KA, with thermal magnetic/adjustable O/L & S/C protection , ICS= 100% ICU = 01 Nos.(iii) Ammeter Digital type, CT operated 0-400 A range, (with selector switch and CT) - 01 Set(iv) Volt Meter Digital type 0-500 V range, (With selector switch) - 01 No.(v) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set. |
| 9 | (II) Outgoing :-(i) MCCB 4P,125,25KA with thermal magnetic/adjustable:O/L & S/C protection, ICS=100% ICU=01 Nos 01 nos(ii) MCCB 4P, 100A, 25KA, with thermal magnetic/adjustable: O/L & S/C protection , ICS= 100% ICU = 01 Nos.(iii) MCCB 4P, 63A, 16 KA, with thermal magnetic/adjustable: O/L & S/C protection , ICS= 100% ICU = 02 Nos. |
| 10 | Supplying, installing, commissioing and testing of LT switchgear panel board ( Kiosk) of size not less than 600mmx600mmx500mm, IP-65 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , 400 Amps coloured horizontal tinned Aluminium bus bars , factory made out of 3.15mm thick MS sheet structure mounted on rigid mild steel angle iron frame of 50mmx50mmx6mm with 400mm long extended legs grouting in platform for panel, with PCC 1:4:8 type D2 with 40 mm graded crushed stone 15cm thick foundation, brick work in CM 1:6 with sub class\\"B\\" old size bricks ,rendering 15 mm thick CM 1:6 on exposed surface and 100 mm thick padding 1:3:6 type C1 using 20 mm graded crused stone draded on top and grouting bolts for LT panel , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front double door and back openable doors with proper locking arrangements for dust and vermin proof ,complete including adjustable thermal and fixed magnetic release MCCB 4 pole, 200 Amps, 415V,36 KA,50 hz -01 No (incoming),suitable size cable allay, lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cable and including taking down old LT panle any size, all as specified. |
| 11 | Supplying, installing, commissioing and testing of LT switchgear panel board ( Kiosk) of size not less than 600mmx600mmx500mm, IP-65 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , 200 Amps coloured horizontal tinned Aluminium bus bars , factory made out of 3.15mm thick MS sheet structure mounted on rigid mild steel angle iron frame of 50mmx50mmx6mm with 400mm long extended legs grouting in platform for panel, with PCC 1:4:8 type D2 with 40 mm agregate crushed stone 15cm thick foundation, brick work in CM 1:6 with sub class\\"B\\" old size bricks ,rendering 15 mm thick CM 1:6 on exposed surface and 100 mm thick padding 1:3:6 type C1 using 20 mm graded crused stone aggreagate on top and grouting bolts for LT panel , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front double door and back openable doors with proper locking arrangements for dust and vermin proof ,complete including adjustable thermal and fixed magnetic release MCCB 4 pole, 100 Amps, 415V,36 KA,50 hz -01 No (incoming),suitable size cable allay, lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cable and including taking down old LT panle any size,complete all as specified & directed. |
| 12 | Excavation in treches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole and cables complete all as specified and directed. |
| 13 | All as per item srl No 06 but in depth beyond 1.5 Mtr and n. exc 3.00 Mtr and taking out in any type of soil. |
| 14 | Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed. |
| 15 | Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete as directed. |
| 16 | Material and labour for river sand, unwashed and screened dry for cushioning to under ground cable in trenches below 8cm before laying & 15cm after laying cable and around under ground cable including spreading and levelling complete as specified and directed.(Note:Punned thickness shall be measured for the purpose of payment) |
| 17 | M&L for replacement of fly ash brick for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm as directed. |
| 18 | M&L for taking down of LT cable of any size and make with necessary excavation for finding of fault and necessary repairing and relaying at the same site after repairing and make functional including testing of cable complete all as specified and directed.NOTE :- excavation , returning filling and removing will be measured separately. Existing brick and sand will be used for relaying of cables. |
| 19 | Supply & Laying jointing, testing and commissioning LT XLPE, insulated, armoured LT 1100 volt grades heavy duty with aluminium stranded conductor should be of through pipes, induct, on poles, in trenches etc. (Note;- (i) Rate quoted includes terminal Lugs / road cutting/ floor cutting/ Inter locking floor and making good damaged portion matching with existing surface with all existing finishes.) complete all as specified and directed Engr in Charge (ii) Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately. |
| 20 | 240 Sqmm, 3.5 core. |
| 21 | 185 Sqmm, 3.5 core. |
| 22 | 150 Sqmm, 3.5 core. |
| 23 | 120 Sqmm, 3.5 core. |
| 24 | 35 Sqmm, 3.5 core. |
| 25 | 25 Sqmm, 4 core. |
| 26 | 16 Sqmm, 4 core. |
| 27 | Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc of following sizes including dismantling and taking down existing pipe. |
| 28 | 80mm bore |
| 29 | 50mm bore |
| 30 | M & L for boring in any type of soil under road 1.5 Mtr below the top surface of road by conventional method complete for passing through 40mm to 100mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed. NOTE :- Pipe will be measured and paid for separatily. Any damage to existing cables of any type will made good by the tenderer without any extra payment. |
| 31 | Taking out old U/S PCC/steel tubular pole LT pole of 9.0 Meters long and Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron / Mild steel base plate, CI finial, taper plug, bolts, nuts and screws as specified,painting exposed surafces steel tubular poles with two coats of aluminium paint over one coat of red oxide primer and and black bituminous paint on steel surafces embedded in concrete and providing 200 mm wide bands (5 bands/ straps with fluorescent synthetic enamel paint in alternate colour of black, green and red 20 cm wide each from top of plinth block and numbering of poles with white Retro Reflective paint on yellow Retro Reflective paint ground(50 mm wide and 100 mm high letters) including encircling the letters of figures incl demolition of PCC complete all as specified.Note:- Excavation,earth work,PCC & return filling,removal of soil to be measured seprately in respective item of schedule. |
| 32 | Dismantling of ACSR conductor of any type /size |
| 33 | M&L aluminium conductor steel reinforces (ACSR) any size as per site requirement as directed straining properly on insulator and binding with aluminium tap/ binding with connectors, jumpers etc,complete all as directed. |
| 34 | Taking down of old existing unserviceable insulator any type and any size and complete all as specified. |
| 35 | M&L pin type, porcelain, vitreous, white or green insulator (LT), 100mm height and 65mm dia, 1100 volts grade including one galvanised MS spindle, two GI washer and one GI nut, and including taking down complete all as specified & directed. |
| 36 | M&L sackle type, porcelain, brown, white or green insulator for working pressure1100 volts grade of 90mm dia and 75mm height including galvanised MS strap of 31mm x 3mm size, 90 mm dia insulator bolts, washers and nuts,and including taking down complete all as specified & directed. |
| 37 | M&L cross arms of MS angle or channel iron including flat iron clamp with bolt, nut & washers drilling for bolts in any shape or size as indicated or directed and including painting with one coat of red oxide primer and one coats of aluminium paint before fixings and and one coat of aluminium paint after fixing including taking old unsv iron complete all as specified and as directed. |
| 38 | M&L for preparation of old painted surfaces of erected steel tubular swaged poles / Rails/Girder poles of LT over head line 9 Meter long including 04 Nos bands/ straps(Black,Red,Green & black) with two coats of paint on pole surface complete all as directed . |
| 39 | M&L for Restretching / tightening of ACSR conductor of any size & GI earth wire of any size of LT over head line on existing poles duly straining properly binding with extra aluminium binding wire to insulators all as directed. |
| 40 | M&L for Cutting of worm out aluminium cable terminal lugs from the LT cable criming of new aluminium cable core and fixing with transformer, Panel MCCB terminal stud including cutting/dressing of cable, excavation surface after providing sand cushioning and brick protection including taking out old unsv aluminium lugs up to 400 Sqmm as specified and directed. |
| 41 | M&L for Triming of tree branches up to 75mm dia to cleen the route of LT over head lines arround the 3 Mtr from the external conductors including removing the cut branches from site and depositing at places all as directed by Engeer in Charge. |
| 42 | M&L for Surface dressing/levelling/ cleaning of surrounding area of 2/4 pole/ plinth mounted transformer structure/ E&M sub station including removing of tree branches small tree plants tarbushes etc complete all as directed. |
| 43 | M&L in replacement of plate earthing for sub station equipments complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.5 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of LT equipments etc at the other, earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate excavation & earth work and RCC cover complete all specified and shown in electrical plate No 3 of SSR Pt-I. |
| 44 | PCC (1:3:6) type C2 using 40mm graded stone aggregated as in foundation, filling and mass concrete using necessary frame work complete all as directed . |
| 45 | PCC (1:4:8) type D2 using 40mm graded stone aggregated as in foundation, filling and mass concrete using necessary form work complete all as directed . |
| 46 | M&L for PCC 1:2:4 type B1 using 20 mm grade for coping of pole including neccesary frame work,fair finishing to exposed surface using extra cement complete all as specified and directed. |
| 47 | S&F in repair MCCB, 4 pole, 50 Hz, 250 Amps, 36kA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. |
| 48 | S&F in repair MCCB, 4 pole, 50 Hz, 200 Amps, 36kA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. |
| 49 | S&F in repair MCCB, 4 pole, 50 Hz, 160 Amps, 36kA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. |
| 50 | S&F in repair MCCB, 4 pole, 50 Hz, 100 Amps, 16KA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. |
| 51 | S&F in repair MCCB, 4 pole, 50 Hz, 63 Amps, 16KA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. |
| 52 | S&F in repair MCCB, 4 pole, 50 Hz, 400 Amps, 50KA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. |
| 53 | S&F in repair MCCB, 4 pole, 50 Hz, 630 Amps, 50KA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. |
| 54 | S&F in repair FP EDO ACB With MP Based O/C, S/C & E/F Protection LSIG Release 6.0E ,4 pole, 630Amps 415V, 50 kA, 50 Hz ,Icu =100% Frame -1 and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. |
| 55 | Supply & Fixing in repair PVC line separator suitable for 2 wire complete all as specified and directed. |
| 56 | Supply & Fixing in repair PVC line separator suitable for 4 wire complete all as specified and directed. |
| 57 | Supply & Fixing in repair PVC line separator suitable for 6 wire complete all as specified and directed. |
| 58 | Dismantling of old existing cross arms of any type |
| 59 | Taking out old unserviceable existing LT cable of size 16 to 95 sqmm 3.5/4 core. |
| 60 | Taking out old unserviceable existing LT cable of size 120 to 300 sqmm 3.5/4 core. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer