Housing Urban and Rular Development Government Departments Closing in 15 days TDR #56698041

Tender For Construction Of Block Level Stadium (Without Indoor Hall) In Ranpur Block Under Nayagarh District

Issued by Government Departments · Nayagarh, Odisha
Tender Value
7.93 Crore
Estimated cost
Bid Submission
13 Aug 2026
15 days left
EMD
7.94 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nayagarh → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Block Level Stadium (Without Indoor Hall) In Ranpur Block Under Nayagarh District

BOQ

Name of Work:- Construction of Block Level Stadium (without indoor hall) in Ranpur Block under Nayagarh District
Sl. No. Item Description
1CIVIL WORKExcavation in all kinds of soil with hydraulic excavator (1 cum capacity) including cutting and loading in tippers, trimming bottom and side slopes ,in accordance with requirements of lines,grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m.work complete as directed by the Engineer-in-charge. Football field
2Atheltic track
3Volleyball court
4Kho kho,Kabadi court
5Internal road and pathwaya
6Approch road
7Pathway Football field peripherial
8Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as directed by the Engineer-in-charge. Football field
9Atheltic track
10Volleyball court
11Kho kho,Kabadi court
12Internal road and pathwaya
13Approch road
14Pathway Football field peripherial
15Supplying and fixing of needle punched staple fiber non woven geotextile fabric under the fabric formed mattress, conforming to the following specifications:Minimum mass 200GSM (MARV Mean Average Roll Value), Minimum thickness 0.75 mm Grab tensile strength 700 N as per ASTM D 4632 Grab elongation 50 as per ASTM D 4632 Trapezoidal tear strength 250 N as per ASTM D 4533 CBR puncture resistance 1800 N as per ASTM D 6241 Minimum wide width tensile strength 12 kN/m. The geotextile shall be needle punched staple fiber non woven type, suitable for separation, filtration, and protection applications, and shall be installed as per detailed site requirements and technical specifications, including proper surface preparation, laying, jointing, and anchoring as per directed by the Engineer in charge. make GEOQUEST,SOLMAX.
16Construction of granular sub-base by providing Grading - VI Material as per table 400-2, mixing in a mechanical mix plant at OMC, carraige of mixed Material to work site, spreding in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 SDB/S. No-4.1/ Page no-94 Football field
17Construction of granular sub-base by providing Grading - VI Material as per table 400-2, mixing in a mechanical mix plant at OMC, carraige of mixed Material to work site, spreding in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 SDB/S. No-4.1/ Page no-94Atheltic track
18Volleyball court
19Kho kho,Kabadi court
20Internal road and pathwaya
21Approch road
22Pathway Football field peripherial
23Supplying , stacking and spreading of good earth at site within initial lead including royalty and carriage transporting to site, spreading, grading to required slope and compacting to meet requirement. Football field
24Atheltic track
25Volleyball court
26Kho kho,Kabadi court
27Supplying , stacking and spreading of root zone sand as per USGA standard at site including royalty and carriage and Laying of root zone sand on the top of aggragate as per desired level.Football field
28Supply and laying of labour and material for Base preparation of grassing and fertilizer apllication in the required proportion specified or directed by the Officer-in-charge.Football field
29Supply & Planting Bermuda grass on site by Planting method directed by engineer in charge. The grass must be weed fee. Rate including all required fertilizer, pesticider & Chemical etc. complete for growing the turf. Spec. No.:- As directed by Engineer in charge. (Including cost of 6 month of Maintenance of football Ground) Football field
30Supplying, stacking, laying and compaction of a consolidated layer, 50 mm thick, of graded material of 4.75 mm to 2.36 mm mixed with cohesive material for stability and grip, etc., as per the direction of the engineer-in-charge.Atheltic track
31Volleyball court
32Kho kho,Kabadi court
33Providing and laying in trenches DWC perforated pipe@ 100mm dia conforming to IS 16098 (Part-2) with all fitting accessories and jointing, including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately).The cost inclusive of labour,material,fitting and fixing,conveyance,loading and unloading etc all complete as per the direction of Engineer-in-charge.
34Providing and laying in trenches DWC non perforated pipe@ 110mm dia conforming to IS 16098 (Part-2) with all fitting accessories and jointing, including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately).The cost inclusive of labour,material,fitting and fixing, conveyance, loading and unloading etc all complete as per the direction of Engineer-in-charge.
35Providing and laying in trenches DWC non perforated pipe@ 160mm dia conforming to IS 16098 (Part-2) with all fitting accessories and jointing, including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately).The cost inclusive of labour,material,fitting and fixing, conveyance, loading and unloading etc all complete as per the direction of Engineer-in-charge.
36Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. Volleyball court
37Kho kho,Kabadi court
38Internal road and pathwaya
39Approch road
40Earth work in excavation of foundation trenches in all kind of soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge. Facility centre
41Security room and Gate complex
42Drainage
43Drainage peripherial
44Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. Facility centre
45Internal road and pathwaya
46Security room and Gate complex
47Drainage
48Approch road
49Drainage peripherial
50Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. Facility centre
51Internal road and pathwaya
52Security room and Gate complex
53Approch road
54Land development and surface filling
55Pathway Football field peripherial
56Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.(make-premise-BAYER,Paxton-FMC,ozie-KALYANI). Facility centre
57Security room and Gate complex
58Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.Facility centre
59Internal road and pathwaya
60Security room and Gate complex
61Drainage
62Drainage peripherial
63Pathway Football field peripherial
64Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge. Facility centre
65Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Facility centre
66Security room and Gate complex
67Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Facility centre-Ground floor
68Security room and Gate complex
69Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Facility centre-Ground floor
70Security room and Gate complex
71Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.Facility centreFooting
72Pedestal
73Column upto plinth
74Plinth beam
75Column
76Lintel
77Roof Beam
78Roof Slab
79Security room and Gate complex Footing
80Column upto plinth
81Plinth beam
82Column
83Lintel
84Roof Beam
85Roof Slab
86Drainage Foundation
87RCC wall
88Drainage peripherialFoundation
89RCC wall
90Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. Facility centre
91Security room and Gate complex
92Drainage
93Drainage peripherial
94Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Facility centre
95Security room and Gate complex
96Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Facility centre
97Security room and Gate complex
98Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Facility centre
99Security room and Gate complex
100Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.Facility centre
101Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.Facility centre
102Providing full body matt finish vitrified tile flooring using vitrified tiles having thickness of min 10mm conforming to IS 13755 of 600x600 of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.Facility centre
103Security room and Gate complex
104Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm homogeneous coloured/ printed series of approved make (JOHNSON / SOMANY/ KAJARIA/ RAK) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects.Facility centre
105Fixing of Ceramic wall tiles of premium grade having thickness 6.50mm to 7.00mm confirming to IS 13753 of size 60cm x 30cm special plain / printed series in dados skirting & riser of steps on 12mm thick cement plaster 1:3 joined with neat cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.(make-Somany, Johnson, RAK, Kajaria) Security room and Gate complex
106Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in floors over 20mm thick bed of cement mortar 1:4 (1cement:4course sand)and filling the joint with white cement mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge.Facility centre
107Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in Dado over 12mm thick bed of cement mortar 1:3 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance & royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge.Facility centre
108Supplying, fitting and fixing vetrified Industrial tiles in floors of premium grade having thickness 8mm to 10mm of size 300mm x 300mm confirming to IS 4457 with colour / printed series of approved make (JOHNSON /RAK / SOMANY/ KAJARIA ) on 20mm thick bed of C.M. (1:4) including cost of all materials, labour, T&P etc. required for the work in all respect as directed by the Engineer in charge.Facility centre
109Providing & Fixinng factory made 100% Solid WPC ( Wood Polymer Composite )- Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comparising of virgin PVC polymer of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm & an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of ( Min. 990 N ),Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght, , all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company. (Make-Green Land / Century/ Alstone) Facility centre
110Security room and Gate complex
111Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.Facility centre
112Security room and Gate complex
113Supplying and fixing of Powder coated 50-60 microns approved colour of Aluminium 40mm Casement series Door Unit with suitable aluminium extrude profiles. the system is designed to accommodate 12mm clear toughened glass of make-Saint gobain/AIS/Gardian/modi. the rate quoted inclusive of hardwares like antilift,roller, Espag lock cum handle,epdm gaskets,T mullion ,Fly Mullion ,bottom adopter ,mid transom ,glazing clip for 12 mm glass felt along with all accessories etc complete. the gap between the wall and window will be filled with silicon weather sealant in the outer side. Casement Door Outer frame - 40mm x 45.3mm Series x 1.4mm thickness, Fly mullion - 44 x 60 mm x 1.4mm thickness, T Mullion 40 x 78.4mm x 1.4mm thickness, Transom - 40.28 x 125.8 x 1.75 mm thickness, Bottom adopter - 34.6 x 26 x 1.5mm thickness, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Jindal,Hindalco,schueco). Facility centre
114Supplying and installing UPVC- 3 track 3 shutter sliding windows with Outer dimension - 104 x 49 sash dimension of 61mm x 39mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 5mm reflective toughened glass . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge.(Make-(Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance). Facility centre
115Security room and Gate complex
116Supplying and installing uPVC- Ventilator windows having section of 55 mm x 50 mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 1.5 mm. The outer will be fitted with 3.5mm pinhead glass . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge. (Make- (Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance). Facility centre
117Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. Facility centre
118Security room and Gate complex
119Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Ground floor Facility centre
120Security room and Gate complex
121Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Ground floor Facility centre
122Security room and Gate complex
123Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. Ground floor Facility centre
124Security room and Gate complex
125Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Ground floor Facility centre
126Security room and Gate complex
127Painting two coat with approved synthetic enamel paint to new wood work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Facility centre
128Security room and Gate complex
129Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Facility centre
130Security room and Gate complex
131Internal road
132Pathway Football field peripherial
133Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. Facility centre
134Waterproofing application:- Providing and application of two component polymer modified flexible cementitious waterproofing coating at a thickness of 1.5 -2.5 mm The membrane should have Elongation equal or more than: 30% Crack Bridging ability : Up to 1 mmAdhesive strength: 1.0 N/mm² @ 28dTensile elongation: 60% @ 20°CShore A Hardness >85 (between 3 - 7 days)etc. as per direction of E.I.C (For longer span, in terrace panel of 4m*4m should be done by groove cutting, and filling with PU Sealant)(make-Myk,Fosroc,Sika). Facility centre
135Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 6 mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. Facility centre
136Security room and Gate complex
137Providing & Installation of GFRC GFRC JALI (Glass Fiber Reinforced Concrete) thickness of 25-30 mm & Border thickness of 50 mm with Pattern, design, and colour of approved make to be fixed on/between RCC /Block work Column or structural work with Dry Fixing method with appropriate SS Pipe & Cleats frame work, using fasteners, and necessary hardware etc. The element shall be made from '53 grade' Portland Cement make Birla/ 'JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass fibre make 'Owens Corning' or equivalent, Super plasticizers / Additives make by 'BASF' or equivalent, Polymers make 'BASF' or equivalent and U.V resistant Synthetic inorganic pigments shall be used for pigmentation make 'BAYFERROX (Germany)' or equivalent. The material casting shall take place in Synthetic Rubber / FRP Mould manufactured by Mould / Tool / Mould Grade Resin of Revex/ 'Reckli'.(Make-Unistone,Samudyam,Eco Vision) Facility centre
138Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x600x50mm, reinforced with 8mm dia four nos longitudinal & 9 nos cross sectional T.M.T hoop bars, including providing 50mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50mmx1.6 mm complete, all as per direction of Engineer-in-charge. Drainage
139Drainage peripherial
140Providing and laying of 80mm thick factory made cement concrete interlocking Paver block of M-40 grade and approved make ,variety,colour and size made by block making machine with strong vibratory compaction of approved design and shape laid in required colour and pattern over 50 mm thick compacted bed of coarse sand filling the joint with fine sand etc.all complete including cost ,conveyance ,royalty of all materials, labour,T&P etc.Complete as per direction of all Engineer-in-charge. Internal road and pathwaya
141Pathway Football field peripherial
142Supplying and fixing of precast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. Internal road and pathwaya
143Pathway Football field peripherial
144Construction , Providing , Supplying and fixing the pre-cast , pre tensioned SFRC compound wall poles having finished dimention of 2000mm x 200mm x 50mm long, (providing the construction joint at the interval of 15.4 mtr) made in M 30 grade concrete with 10 Nos of 4mm dea. HTPC ( High Tension Pre Coated) wire, fixed in cast in situ PCC m 20 concrete in foundation footing of size 600 mm dia 750 mm depth from top inside the pre cast RCC collar ( NP 2) of 600 mm Internal dia. and length of 750 mm placed over a base of PCC (1:4:8) of size 680mm dia, 100 mm depth including excavating foundation pit for each pole, kind of soil of size 680mm dia, 850mm depth ( at expansion joint of 15.4 m interval where combined poles are to be places with 900mm internal dia of NP 2 collar of 750mm height) including watering & curing for required days along with supplying, fitting & fixing of pre cast , pre tensioned, SFRC slab having dimention of 2100mm (long) x 300mm (Wide)x 50 ( thick) 7.5 Nos. per span, made with M-30 grade concrete with 4mm dia. GI HTPC wire 4 Nos. covering the top of the compound wall poles with a pre cast SFRC cover of size ( 300x300x150) mm in order the prevent the slab panels from removing . all complete as a set to be measured in term of running meter including such pre cast , SFRC top cover, slab, pole, including painting two coats of approved weather coat paint over a coat of wall primer including curing cost and conveyance of all materials, royalties, taxes all labour, labour cess, T&P required for the work etc. complete including dewatering if required as per the direction of the Engineer in Charge(Excluding cost of GST) Compound wall
145Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre. Compound wall
146EARTH FILLING-Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2. Land development and surface filling
147Supply & Installation of AIFF/FIFA Compliant Portable & Movable Football Goal Post , Size 7.32 M X 2.44 M Inner to Inner, With 8 Inch Non Marking solid Galvanised Wheels for smooth movement, Main pipe made of 100mm Round Powder Coated High Grade Aluminium Alloy Pipe of 3mm thickness, Back Support made of 60mm Round Powder Coated High Grade Aluminium Alloy Pipe of 2.5 mm thickness, No sharp edges, All corners fully welded and ground smooth, 220 Pcs Polyproplene unbreakable net clips no sharp edges, including transportation, Installation, testing & commissioning as per Engineer-In-Charge Must be of reputed make like Stag Global, Nelco, SodexSport.
148Supply & Installation of FIVB Compliant Portable & Movable telescopic Volleyball Post, Made of heavy duty 100mm round Aluminium Alloy Pipe with crank system for height adjustment 2.43 m for mens & 2.24m for womens, With 120kgs Weight Stacks for stability. Steel pulley on top, including transportation, Installation, testing & commissioning as per Engineer-In-Charge. Must be of reputed make like Stag Global, Nelco, Senoh
149Supply & Installation of Kho Kho Pole,Two rigid poles of 1.20 m height from ground level, Heavy Duty 4 inch Dia Smooth & Round Steel Uprights, No sharp edges to prevent injury. Must be of reputed brands like Nelco, StagGlobal, Gravolite
150Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing, specification and direction of Engineer-in-charge. Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm.
151Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm.
152Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.( Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).
153Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge.
154Providing and fixing post delineators made of ABS round body fitted with 2 nos 100 mm dia high reflective reflectors and mounted on MS pipe of 65 mm dia duly powder coated anti-rust and anti theft steel to be installed as per direction of Engineer-in-charge.
155Providing and fixing letters made out of acrylic sheet with light arrangement as per the architectural drawing/design complete with all materials cost, coveyance, loading and unloading, royalties and cost of all labour, T&P, sundries, with necessary scafolding & accessories complete in all respects as per the direction of architect / engineer in charge.600mm height
156300mm height
157Plastic Waste bin Rectangular alongwith fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level. Capacity-60 350x350 mm Top Dia.250x250 mm Bottom Dia.850 mm Height pair Sintex, Nilkamal, Otto, Aristo
158Plastic Waste bin without Wheel with Push type Top load along with fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level capacity 60 pair 350x350 mm Top Dia. 250x250 mm Bottom Dia. 850 mm Height Sintex, Nilkamal, Otto, Aristo
159Plastic Waste bin without Wheel with Swing lid type Top load along with fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level. Capacity-60 pair 350x350 mm Top Dia. 250x250 mm Bottom Dia. 850 mm Height Sintex, Nilkamal, Otto, Aristo
160Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of land manure before and after flooding trench with water (excluding the cost of imported earth, sludge or manure).
161Supplying and stacking of good earth at site (Earth measured in stacks will be reduced by 20% for payment) with all lead and lift.
162Supplying and stacking sludge at site (sludge measured in stacks will be reduced by 8% for payment) with all lead and lift.
163Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment).Screened through sieve of I.S. designation 20 mm.
164Screened through sieve of I.S. designation 16 mm
165Screened through sieve of I.S. designation 4.75 mm
166Rough Dressing the trenched ground including breaking clods etc.all complete as per the direction of Engineer-in-charge.
167Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
168Fine dressing of the ground
169Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
170Mixing earth and sludge or manure in proportion specified or directed.
171Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge
172Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.
173Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 60 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (The manure/sludge shall be paid for separately).
174Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately). Holes 60 cm dia, and 60 cm deep
175Holes 45 cm dia, and 45 cm deep
176Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge.
177Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal and 4 nos vertical U shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows and height, all complete as per direction of Officer in charge.Top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall thickness of 25.4 mm
178Filling of the following size empty pots with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer incharge. (The cost of good earth, earthen pots & manure will be paid separately.) Size of Empty Pots 35cm Top dia, 25cm Bottom Dia & 35cm Perpendicular height.
179Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.
180Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge.
181Plantation of Trees Shrub and Hedge at site ic watering and removal of unserveiceable materials as per direction of officer in charge (excluding cast of plant and water). Trees Plant
182Shrubs Plant
183Hedge Plant
184Providing and displaying of Aglaonema dove variety Plant, having ht. 30 cm to 45 cm with 8 to 10 leaves, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
185Providing and displaying of Aglaonema Snow-White hybrid plant (three in one), having ht. 30 cm & above with 6 to 8 leaves, bright colour, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot . (Specimen Plant) & as per direction of the officer-in-charge.
186Providing and displaying of Areca Palm plant, having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 20 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
187Providing and displaying of Croton Challanger variety plant, having ht. 30cm and above, well developed with full of fresh and healthy leaves in 20 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
188Providing and displaying of Croton Baby Golden plant (three in one), having ht. 30cm, multi branches, well developed with fresh and healthy foliage in 25 cm size of Earthen pot / Plastic pot. as per direction of the officer-incharge.
189Providing and displaying of Dracaena Song of India plant (three in one), having ht. 30 cm and above, multibranched, well developed with fresh and healthy leaves in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
190Providing and displaying of Money Plant Broad Leaves mounted on moss stick 90 cm ht., 3 to 4 plants in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot / Plastic pot . & as per direction of the officer-in-charge.
191Providing and displaying of Phoenix palm plant, having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
192Providing and Displaying plants Cladium Hybrid variety 3 to 4 plants in a pot well developed with fresh & healthy foliage 30 to 45 cm ht. in different colour 25 cm Earthen Pot/Plastic Pot and as per direction of the officer incharge.
193Providing and Displaying plants Cosmos well developed fresh & healthy 20 to 25 cm ht. attractive colours multi branching at blooming stage in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
194Providing and Displaying plants Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.
195Providing and Displaying plants Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.
196Providing and Displaying Acalypha green plant well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot bushy plant as per direction of the officer-in-charge.
197Providing and Displaying Bamboo Buddha vally variety with umbrella shape plant having 120 to 135 ht. with fresh & healthy foliage well developed in 40 cm Cement pot multy branch, bushy plant as per direction of the officer-in-charge.
198Providing and fixing overhead type sprinkler system with self closing valve type 25mm X 20mm with self closing spring made up of alluminium alloy and brass fittings including cost of all materials, labour, T & P etc complete as per direction of Engineer-in-charge.
199Supplying all materials, labour, T&P and fixing 15mm dia CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
200Supplying all materials, labours, T&P and fitting and fixing of the 20mm dia CPVC pipe confirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge. (Concealed)
201Chair BEAT HIGH BACKSEAT BACK ASSEMBLY The seat and back is made up of 1.2 0.1cm thk. hot pressed plywood measured as per QA method described in OCP QLTA PL1418 upholstered with synthetic leather over moulded High Resilience Fixed Armrest Top is PU moulded over metal insert.FRONT PIVOT SYNCHRO MECHANISM The adjustable tilting mechanism is designed with the following features. 360 revolving type.Single point control. Front-pivot for tilt with feet resting on ground ensuring more comfort. Tilt tension adjustment. 4 position locking with anti shock feature. Back height adjustability is applicable for for High back and Mid back chair.PNEUMATIC HEIGHT ADJUSTMENT The pneumatic height adjustment has an adjustment stroke of 10.0 0.3 cm. Facility centre
202Almirah Storwel Plain (1981H x 916W x 486D)Storwel plain shall have an overall size of 916mm(W)x486mm(D)x1980mm(H) with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA D grade high yield strength as per IS 513. The Storwel Plain should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (10). Plenty of colour options and shelving options shall be available. Facility centre
203EASY RACK 6615 (SIZE - 1800Hx900Wx450) IN MMSlotted Angle 4 nos, with 6 nos Self. Facility centre.
204Table Model- Enterprise 1500 W/o CPU hanger (SIZE - 1500W x 750D x 740H) IN MMOverall size of 4 - Door PLU + Lkr (Base) shall be 380mm(W)x450mm(D)x1830mm(H). Stackability shall have add - on units that can be stacked width wise to form bank of lockers having common side panel. Locking shall have 10 Lever cam lock with lock lever plus option of hasp arrangement . Material shall be CRCA 0.6 mm thickness . Construction shall be Rigid Knockdown construction , shelf shall be uniformly distributed load capacity per each shelf level is 35 Kg maximum . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Handle/Label holder shall be Aesthetically appealing Snap fit ABS plastic handle . Ventilation shall be attractive punched pattern for ventilation. Facility centre
2054 - Door PLU LockerOverall size of 4 - Door PLU + Lkr (Base) shall be 380mm(W)x450mm(D)x1830mm(H). Stackability shall have add - on units that can be stacked width wise to form bank of lockers having common side panel. Locking shall have 10 Lever cam lock with lock lever plus option of hasp arrangement . Material shall be CRCA 0.6 mm thickness . Construction shall be Rigid Knockdown construction , shelf shall be uniformly distributed load capacity per each shelf level is 35 Kg maximum . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Handle/Label holder shall be Aesthetically appealing Snap fit ABS plastic handle . Ventilation shall be attractive punched pattern for ventilation. Facility centre.
206LOOP BENCH INGRID V2Overall size of 4 - Door PLU + Lkr (Base) shall be 380mm(W)x450mm(D)x1830mm(H). Stackability shall have add - on units that can be stacked width wise to form bank of lockers having common side panel. Locking shall have 10 Lever cam lock with lock lever plus option of hasp arrangement . Material shall be CRCA 0.6 mm thickness . Construction shall be Rigid Knockdown construction , shelf shall be uniformly distributed load capacity per each shelf level is 35 Kg maximum . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Handle/Label holder shall be Aesthetically appealing Snap fit ABS plastic handle . Ventilation shall be attractive punched pattern for ventilation. Facility centre
207PH WORKCommon Facility Centre & Gate ComplexSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge. (Supreem/Ashirvad/Oriplast/AKG) Ground Floor 25mm dia PVC ASTM pipe (sch-80)
20832mm dia PVC ASTM pipe (sch-80)
209First Floor-40mm dia PVC ASTM pipe (sch-80)
21050 mm dia PVC ASTM pipe (sch-80)
211Supplying all materials, labour, T&P and providing and fixing to the wall or ceiling and floor CPVC pipes conforming to IS:15778, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00. spacing. This includes the jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge. (Supreem/Ashirvad/Oriplast/AKG) Ground Floor20mm dia CPVC pipe.
21225mm dia CPVC pipe
213Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall Ground Floor
214Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge. Ground Floor
215Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.Ground Floor
216Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15 mm dia 2 WAY BIB COCK WITH WALL FLANGE (FLR-CHR-5041N ) ( Jaquar/Cera/hindware/equivalent Make)
21715mm dia CP Health Faucet (ALD-CHR- 577) Jaquar/Cera/hindware/equivalent Make
21815mm dia CP Long body bib cock( Jaquar/Cera/hindware/equivalent Make)CON-CHR-107KN
21915mm dia CP ANGULAR STOP COCK WITH WALL FLANGE (FLR-MCH-5053N Jaquar Make )
22020mm dia CP CONCEALED STOP COCK EXT HVY WTH WITH FLANGE(FLR-MCH-5083N Jaquar/Cera/hindware/equivalent Make
22132mm dia CP Bottle trap Jaquar/Cera/hindware/equivalent Make -ALD -CHR-769L -300x190cm,
222Auto closing concealed urinal flush valve Jaquar/Cera/hindware/equivalent Make -PRS-CHR-077
22315 mm dia CP pillar cock auto closing system Jaquar/Cera/hindware/equivalent Make -PRS-CHR-031
22415mm dia CP SINK cock (Jaquar)FLR-CHR-5347N
225Soap Dispenser with glass bottle(ACN-CHR-1135N) Jaquar/Cera/hindware/equivalent Make
226CP soap Dish holder (Jaquar make)-AKP-ABR-35731P Jaquar/Cera/hindware/equivalent Make
227Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN), Jaquar/Cera/hindware/equivalent Make
228600mm long CP towel rail(Jaquar)-ACN-IVY-1111NM, Jaquar/Cera/hindware/equivalent Make
229Caot hook(Jaquar)No.ACN-CPG-1161
23025mm dia brass or gun metal fullway valve(shakti /equivalent Make)
23132mm dia brass or gun metal fullway valve shakti/equivalent Make )
23240mm dia brass or gun metal fullway valve shakti /equivalent Make
23350mm dia brass or gun metal fullway valve shakti /equivalent Make
23415mm dia CP flange
23515mm dia CP extension piece
236Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge.15mm dia CP revolving shower With shower arm Jaquar/Cera/hindware/equivalent Make OHS-CHR-1985+SHA-CHR-477
237Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Hindware / Parryware /Make)
238Supplying all materials ,labour ,T&P and fixing wash kitchen sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste , fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc. including cutting holes in walls and making good the damages etc.all complete as per specification and direction of Engineer-in-charge.600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make)
239Supplying all materials, labour, TandP and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non heat application method as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge(Supreem/Ashirvad/Oriplast/AKG) In ground floor 110mm dia U PVC SWR pipe
24075 mm dia UPVC SWR Pipe
24150mm Dia UPVC Class-IV Pipes
242110mm U-PVC door tee
243110mm U-PVC Plain tee
244110mm U-PVC door bend
245110mm U-PVC plain bend
246110mm dia U-PVC 'P' trap
247110mm dia U-PVC Plain Shoe Bend
248110mm dia U-PVC offset with out ear
249110mm dia U-PVC cowl
25075 mm dia UPVC plain bend (supreme/ashirvad)
25175 mm dia UPVC plain Tee (supreme/ashirvad)
252125mm dia CP grating
253PVC clamp suitable for 75 mm to 110mm dia pipe
254Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall.
255Supplying all materials, labour, TandP and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral P or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with S trap plain with seat cover (Parryware/Hindware/Equivalent)
256Supplying all materials, labour, Tand P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI P or S trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge.580mm size Orissa pan (Parryware/Hendware/Equivalent make )
257Supplying all materials, labour, TandP and fixing wash basins with hole for pillar taps conforming to IS 2556 part 4 2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in chargeHalf pedestal Basin(Hindware)No.91049 91115
258Table top basin JDS-WHT-25935 (Jaquar make)
259Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge. Design mirror
260Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Parryware / Hindware make)
26115mm dia urinal spreader
26232mm dia C.P. dome waste
263Supplying all materials, labour, T&P and fitting & fixing of toilet front partition size 0.12x0.5 with door made 12mm thick solid compact laminated (Phenolic core board) reinforced with celluse fibres, the partision fixed in wall hanging with clamps complete etc as per specification and direction of the Engineer in charge.Urinal Partition wall-size - 0.90x0.50
264Supplying all materials, labour, T&PProviding,fitting & fixing of toilet Cubicle made out of the material and specification as detailed below:(Cubicle)(1000mm(W)81550mm(D)x2003mm(H)Providing Intermediate panel,Plaster & door: The intermediate panel is one continued panel without any joints. All intermediate panel is one continued panel without any joints. All intermediate panels,pilasters and doors shall be 12mm thick with edges chamfered. The solid compact laminate(Phenolic Core board)is based on thermosetting resins,homogeneously reinforced with celluloselfibres. Top surface on both sides is melamine coated which is scratch and impact resistant.Providing Hardware and fixing: All pilasters are to be supported by adjustable foot and non corrosive inserts. Top rail and wall fixing with and exteror polyamid coating quarantees resistance to breakage,heat,humidity and chemicals. The base of the adjustable foot will be anchored to the floor with a clearance height of 100mm. Aluminum U-Channel will be used for the fixing of intermediate panels to the wall.1 unit. Compact laminated cubicle L Partition with door
265Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor
266Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor
267Supplying all materials.labour.T&P and providing brick work with KB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar(1:4) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge.
268Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
269Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge.
270Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. 0.80 qntl/ cum
271Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. Ground Floor
272Supplying all materials, labour, T&P and providing vitrified tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany / Johnson to be pre-approved 600 x 600mm of size.
273Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 600x 300 size. Ground Floor
274Supplying all materials, labour, T&P and fixing Granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge In Ground floor
275Supplying all materials, labour, T&P and providing distempering 2 coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in charge.
276Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.
277Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter.
278Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
279Supplying all materials,labour,T&P and fixing 2000 ltr Rotational moulded polyethylene cylindrical vertical water storage tanks(3 layers) conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge.In First floor
280500 liters capacity PVC water storage tank roof of 1st floor
281Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV (Eureka Forbes)of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge.
282EXTERNAL P.H. WORK-Sinking of 200mmx150mm dia large Tube well(2 Nos.)Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore.Labour for Drilling of 200 mm dia bore 0mtr to 120mtr
283Labour for Drilling of 150 mm dia bore 0mtr to 120mtr
284Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.Lowering of 200 mm dia GI/P.V.C/MS casing pipes 0 mtr to 30 mtrs
285Lowering of 200mm dia GI/P.V.C/MS casing pipes 31 mtr to 45 mtrs
286Cost of 200 mm dia ASTM-D-1785/89 P.V.C schedule-80 pipe
287Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge.By DTH
288Supplying all materials and labour,tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level(as per drawing)to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock the bottom to ensure sanitary sealing(excluding cost of cement which willbe supplied by the Department). Submerssible Pump Set 1.5 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 6110 L.M.P with outlet dia of 32 mm.
289DOL control panel
2902.50 sqmm cable
29132mm dia steel short piece
29232 mm dia HDPE Pipe
293Bore Cap
294C.I.Bracket
295Rope Wire
296Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site.
297Supply all materials,labours,T&P and construction bore well protection chamber of the inside size 650x650x1000 height with cement concrete ( 1;3;6) using 40 mm size hard granite metal on foundation,1st class fly ash brickwork incement motar(1:3),with base cement concrete (1:2:4) useing 12 mm size h.g chips ,12 mm thick cement plaster (1:4) inside and out site ,R CC cover slab in (1:1.5:3) using 12 mm size h.g chips earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering ,curing,convayance of all materials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of the engineer-in -charge. Bore well protection chamber.
298Supplying all materials, labour, Tand P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS 4985 2000 of the following outside dia for class 3(0.60mpa) including jointing with supply of approved solvent cement by non heat application method as per manufacturers specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C 1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia U PVC Alround Concrete(Supreem/Ashirvad/Oriplast/AKG)
299160mm dia U-PVC Alround Concrete
300Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm
301Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm .
302---- do --- addl depth of 0.15m upto 0.90m
303R.C.P.C.Manhole Cover
304Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
305R.C.P.C.Manhole Cover
306Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit.
307Construction 1 nos 100 users RCC Septic tankEarth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
308- do - with addl. Depth of 1.5 m
309Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
310Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
311Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
312Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
313Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.For Roof slab
314For RCC wall
315Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
316Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
317Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge
318Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
319Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
320Construction of 50000 Litres RCC Underground Reservoir of Inside size- 7.00 X 3.50 X2.30mEarth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department.
321-do- with Ist additional depth of 1.50 m over the initial lead and lift
322Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
323Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
324Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement and shuttering.
325Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.
326Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.RCC floor roof, chajja etc
327RCC Beam, Column, wall etc
328RCC Plinth bend/ Raft
329Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site.
330Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
331Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.
332Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge
333Construction of 6.75mx3.60m x 1.40m(h) Rain water harvesting system- 3 Nos.Sinking of tube well through D.T.H.Rig.200mm dia- 0.0m to 30.00m
334Lowering of PVC casing pipe inside bore.200mm dia- 0.0m to 30.00m
335Cost.of 200mm dia (Sch.80)Pipe
336Cutting slot in casing pipe for recharge of rain water
337Labour for packing gravel outside the tube well1x25.0mx22/28{(0.40)²-(0.20)²}=2.36
338Cost of washed gravel.
339Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge.
340Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
341Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
342Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
343Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
344Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
345Supplying all materials, labour, T&P and providing reinforced cement concrete work of M-25 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
346Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
347Providing and filling filter media40mm size bolder-1x1x6.0x2.50x0.85=12.75
34820mm size washed gravel-1x1x6.0x2.50x0.40=6.00
349Course sand-1x1x6.0x2.50x0.30=
350Providing fitting and fixing M.S.grill,Jalli cover over the harvesty pindi
351BASIC IRRIGATION SYSTEM (SPINKLER SYSTEM)Providing, laying & jointing in position MS/PVC pipe conforming to ISI standard 4985:2000 and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instruction, PVC PIPE 110mm-6 kg/cm2
352Earth work excavation and refilling 300x450mm
353SPRINKLERS & ACCESSORIESSupply Installation Testing & Commisioining of ST-1200 BR having Radius: 20.4 m to 35.1 m ,Nozzle choices: 12,Nozzle trajectory: 22.5°,Isolated, grease-lubricated gear drive,Nozzle barrels: short and long (included),Movable stops (left and right) arc adjustment,Arc setting: 40° to non-reversing 360°,Ratcheting nozzle turret,Recommended pressure range: 2.0 to 6.0 bar; 200 to 600 kPa,Flow: 6.13 to 29.76 m3/hr; 102.1 to 495.9 l/min
354Supply & Installtion of, 2\\" QCV Connection Assembly etc. item complete.
355Supply & Installtion of PVC/ HDPE service saddle of varying size 2\\" item complete.
356VALVES & ACCESSORIESProviding & fixing of Isolation Valve in mainline for bypass and flow diversion of approved quality 100 MM
357Providing and fixing of PVC Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem non mechanical ,with a base which permits maximum penetration into the valve of size 63mm.
358Providing & fixing of a double acting 1\\" Air release valve, The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar. Including service saddle and riser assembly.
359Providing & fixing of 12\\" Rectangular Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout
360Providing & fixing of 6\\"Round box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout
361PUMPING UNITProviding & Fixing of (Monoblock/Openwell submersible) pumpset of having discharge 6 lps@ 52 mtr head Model no.-1050 . suitable for pumpset having panel box and fixed alongwith following accessories starter ,start / stop push buttons , Ammeter, Voltmeter , Indicating lamps, MCB , with cable, etc.
362Cpvc Pipe header assembly as per requirements
363Providing & fixing of Non Return Valve 4\\" to prevent back flow
364Providing and fixing of Pressure Release Valve 2\\".
365E.I WORKCOMMON FACILITY CENTER Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make of Modular GI box - Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) NB:All the electrical,Fire fighting,HVAC,ELV drawings,LUX Level design of the arena lighting, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP-A
366GROUP-B
367GROUP-C
368Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
369Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
370Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
371Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
372Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
373Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
374Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
375Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
376Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4)
377Supply, delivery, installation & testing of Modular G.I. box 18 SWG Sheet ISI marked with Modular base & cover for 2 moudle tv socket outlet.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)
378Wiring to Telephone Socket Outlet from Junction Box with 0.5 mm2 Four Pair Copper Conductor Telephone Wire run inside prelaid PVC Conduit complete including termination, testing etc complete as required and as per Direction of Engineer-In-Charge.
379Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused complete as required and as per Direction of Engineer-In-Charge.
380Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
381Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . In case, the distance between ODU and IDU exceeds 3 mtr, then only the item of copper pipe shall be executed without any joint and equivalent mtr shall be deducted from the copper pipe item. 1.5 TR with 5 Star BEE Rating (LG-AS-Q20JWZE/ O General-ASGG18CGWA-B/ Daikin-FTKU50XV16)
382Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.
383Supply,installation & fabrication of MS base frame for outdoor unit and other nesessary material to complete the job.
384Supply,installation & fabrication of 25 mm Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.
385Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV) 20 MM
38625 MM
387Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
388driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow 1500 CFM @ 15mm MMWG static pressure
389Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata) 22 gauge (0.80 mm thickness)
39024 gauge (0.63 mm thickness)
391Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire
392Supplying, installation, testing and commssioning of 1200 mm sweep white milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3 min Make Crompton Energion Groove Havells Efficiencia Neo Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg. in Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) .
393S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
394SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
395SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)
396Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
397Supply, Installation, Testing & Commissioning of of IP65 (10-12)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-LITE/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro
398Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
399Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
400Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year.
401Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year.
402Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year
403Supply ,installation ,testing & commissioning of 5KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer of 1ph in put to 1 ph output,230V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 26AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for services building
404Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (with charcoal and salt) as required and as per direction of Engineer-in-charge.
405Providing and fixing 6 swg GI wire on surface or in recess for loop earthing as required and as per direction of Engineer-in-charge..
406Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
407S/I/T&Commissioning of LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA. In commer--01 number of 125 Amps MCCB 25 KA , tmr based, Ics=100%Icu, (Legrand-dpx3/abb-formula/schneider-cvs/siemens-3va) 01 number of 125 Amps 4P onload type Changeover with both source ON/OFF indication (Make-Siemens/Sc hneider/ABB/LEGRAND) Busbar- 04 numbers of 200A Aluinuium busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (ii) 03 nos 63A 4P MCB 10kA,C series , 03 nos 63A DP MCB 10kA,C series, 02 nos 32A DP MCB 10kA,C series LIGHT BDB AC IDU BDB/LIGHT BDB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 03 nos 63A 4P Amps MCCB 16 KA,tmr based, Ics=100%Icu for volley court.(Legrand-dpx3/abb-formula/schneider-cvs/siemens-3va) Instrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication for both the source with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).. (ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Siemens/Schneider/ABB/Legrand) with CTs 63/5A 3 nos class 1 type(Make-Siemens/Schneider/ABB/Legrand) (iv) 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA for the incomer.Make of SPD-Siemens/Schneider/ABB/Legrand/OBO/Dehn. Make of MCB-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200
408Supplying and fixing 32amps rating,double pole mcb type changeover 240 volts, C series,10KA breaking capacity, of Make-LEGRAND/ Siemens/ Schneider/ABB the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. for UPS Outgoing )
409Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 50 sq mm
410Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x50 sq mm
411Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
412Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m)
413Danger Board.
414Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
415Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog .4.5 kg capacity
416Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog.6 kg capacity
417SITC of 4 pair Cat6 23 awg U UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI TIA 568 C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from 20 to 70 C Cable support Conductor Resistance 9.38 100m Max., Cable support Delay Skew 45 ns100m, Operating Voltage 72V , Impedance 100 15 100 MHz. and Propagation Delay 250 MHz 536 ns 100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make Systimax, Legrand, Panduit.
418SITC of Cat6 I O with single Face plate The Outlet shall meet or exceed requirement as per ANSI TIA 568C.2,ISO IEC 11801, and EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 250Mhz and CAT6A 500Mhz. The information outlet connector shall be of gold nickel, thickness of gold 0.8 m. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS UL94 V O certified. Make Systimax, Legrand, Panduit
419SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
420SITC of Cat6 UTP 23 AWG Patch Cord Patch cord 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI TIA EIA-568 C.2 Standard. Supports Data Networks Speeds Up to 10 100 Base T and 1000 Base T. Available In LSZH Jacket Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50 Gold Plated Contacts , 100 Factory Tested , Transparent Boot Cable Assemblies. Make Systimax, Legrand, Panduit(1 mtr length)
421SITC of Cat6 UTP 23 AWG Patch Cord Patch cord 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI TIA EIA 568 C.2 Standard. Supports Data Networks Speeds Up to 10 100 Base T and 1000 Base T. Available In LSZH Jacket Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50 Gold Plated Contacts , 100 Factory Tested , Transparent Boot Cable Assemblies. Make Systimax, Legrand, Panduit(2 mtr length)
422SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
423SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19 ,Dimensions (mm) 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR 326 Core . Make Systimax, Legrand, Panduit
424SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
425SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear
426SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 380W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP
427SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
428Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low Light IR Fixed Lens Dome/Bullet Camera, 1/2.8 CMOS or better, 5MP (2592 x 1944) 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 1/100,000 Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H 96.5 V 73.8 (dome)/ Field of View FoV H 94.1 V:71 (bullet), BLC, HLC, WDR, 2D/3DNR, White Balance Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics Video Motion Detection, Tampering, Loitering, Intrusion, and People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES 128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range 30 C to 60 C. Certifications ONVIF Profile S/G/T compliant CE (EN 50130 4), FCC Part 15, EN 55032 and RoHS (EN63000),NDA,STQC compliant. Make Honeywell Value series/Pelco/Axis/Bosch
429Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low Light IR motorized Lens Dome/Bullet Camera, 1/2.8 CMOS or better, 5MP (2592 x 1944) 25fps or better, four stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 1/100,000 Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7 13.5mm motorized, Field of View FoV H 100 28.5 V 73 21.4 BLC, HLC, WDR, 2D/3DNR, White Balance Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics Video Motion Detection, Tampering, Loitering, Intrusion, and People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES 128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 and IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range 30 C to 60 C. Certifications ONVIF Profile S/G/T compliant CE (EN 50130 4), FCC Part 15, EN 55032 and RoHS (EN63000),NDA,STQC compliant. Make Honeywell value series/Pelco/Axis/Bosch
430Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).Make-Honeywell value series /Pelco/Axis/Bosch
431Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba
432SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
433S/I/T&Commissioning of LT Outdoor CPRI tested floor mounted cubical type electrical control panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 40X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.Provision of 65kA 3P+N type 1+2 SPD alongwith 100A, 4P, MCCB,25 kA , with TMR based release with adjustable overload ,Icu=100%Ics, . Make-LEGRAND-DPX3/ Siemens-3VA/ Schneider- CVS/ ABB FORMULA is to be given in the incomer.Mandatory provision of cable alley is to be given. In commer- 01 no 400 A 4P MCCB 36kA with LSIG Microprocessor release ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula),320 A 4P Manual Changeove Busbar- 04 numbers of 500Amps aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator .Out going- 04 nos 125A 4P MCCB 25 kA , with TMR based release with adjustable overload ,Icu=100%Ics, . Make-LEGRAND-DPX3/ Siemens-3VA/ Schneider- CVS/ ABB FORMULA . 01 nos 250A 4P MCCB 25 kA , with TMR based release with adjustable overload ,Icu=100%Ics, . Make-LEGRAND-DPX3/ Siemens-3VA/ Schneider- CVS/ ABB FORMULA.Instrument- (i)3 numbers phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) (ii) Provision of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand) for all the incoming and outgoing feeders. (iii)Provision of 3 ph digital type Ammeter(Make-Siemens/Schneider/ABB/Legrand) with CTs 3 nos class 1 typeof suitable rating for all the incoming and outgoing feeders. Make of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula (To be placed near the transformer)
434Volley,Kho kho, kabaddi areaSITC of high quality integrated LED Flood Light with a minimum system lumen of 26K Lm or higher and nominal efficacy of 130 lumen/watt or higher. CCT of 5700K with SDCM of 5 and CRI 80. The housing should be of pressure die cast aluminum (ADC12) to with stand extreme environments. The luminaire should come with with PF 0.95, THD 10, Lifetime of 50K hours L70. Product should be suitable for continuous operation (10 12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COBs are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications average lighting level shall be 500 LUX ,min to average shall be 0.7, min to max shall be 0.5 and shall be approved by SEEC(R&B) and CE,Bdgs,O,BBSR before final procurement. Only sport series flood light will be accepted.Make Philips/ Lighting Technologies/ Schréder
435Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 6nos. or more of flood light as per final lux level design) manufactured from HT steel having base dia if 210 mm & top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/HR or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Valmont /Vakrangee
436Excavation in all types of soil for foundation pit size 1.4m×1.4m×1.8m depth including shoring/strutting if required, stacking excavated material and disposal within 50m lead Plain Cement Concrete M10 (1:3:6) for PCC bed below footing, 100 mm thick, including mixing, placing and curing (Size: 1.5m×1.5m),Reinforced Cement Concrete M25 (fck=25 N/mm², Fe500 TMT rebar) for RCC footing 1400×1400×600 mm, including formwork, placing, vibrating and curing ,Reinforced Cement Concrete M25 for RCC pedestal 650×650×1200 mm height, including formwork, placing, vibrating and curingFe500 TMT reinforcement bars for footing and pedestal (T12 @ 150 c/c both ways bottom mat, 8T12 vertical pedestal bars, T8 @ 150 stirrups) including cutting, bending, binding and placing Backfilling around foundation with excavated/selected earth in 150 mm layers, watered and compacted to 95% MDD using plate compactor Cement mortar (1:3) grouting under base plate after pole erection, finished neat and flush with pedestal top.The foundation design should be approved from concerned SE/CCE(Civil wing) before execution of the work.
437SUB PANEL:S/I/T&Commissioning of LT outdoor floor mounted doubledoor CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given. Incomer:63 A 4P MCCB (16 KA) with adjustable thermal setting Ics = 100% of Icu Bus bar: 4 nos. 100A aluminum busbar duly sleeved Instruments: 1 set.LED type phase indicating lamps with control fuses Outgoing :12 Nos 6A DP MCB. (10 KA), C series complete as per the direction of Engineer-in-charge MAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Make of MCBs- LEGRAND-DPX3/Siemens-Betaguard-Schneider-Acti-9/ABB SB200
438Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.Power Cable 3.5C 25sq mm Aluminium Armored Cable : 3.5 core 25sq mm Armored aluminium cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating.
439Power Cable 3C* 2.5sq mm Copper UnArmored Cable : 3 core 2.5 sq mm multistand unarmored cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating..
440Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
441EARTHINGSupplying,installation,testing & commissioning Of Earthing with GI earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge.
442Providing and fixing 6 swg GI wire on surface or in recess for loop earthing as required and as per direction of Engineer-in-charge..
443Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
444Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
445Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB
446Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
447Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB
448Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB
449Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
450Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB
451Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OOBO/Dehn/ABB
452Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB
453Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
454Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB
455Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB
456Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
457Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB
458Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB
459Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB
460Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB
461Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB
462Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB
463Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
464Fire Fighting SystemSupplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame, with RCC foundation for motor as per the manufacturer's standard installation specification.The installation height of motor must be above 450 mm. Make-Wilo/KSB/Kirloskar/Grundfoss
465Supply, installation, testing and commissioning of CPRI Approved Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MPCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF/TRIP indication lamps, Auto manual switch, provision for interlocking with pressure switch should be provided and ON/OFF push button.as per direction of engineer in charge.make-Legrand/schneider/Siemens/ABB
466Supplying, Installing, Testing and commissioning of 1100 V GRADE POWER/CONTROL CABLES :SITC of FRLS, PVC outer sheateh, steel armoured, copper, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge. Make - Polycab / KEI/Gloster/RR kabel/Havells/Finolex 2 C x 1.5 mmsq
467Supply & Laying ofAl armoured XLPE power cable of 1.1 KV grade of following size on Cable 3C X 16 sqmm xlpe Armoued cable
468End Termination 3C X 16 sqmm
469Supplying, installation testing and commissioning of the following C class MS Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pyp kote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS 10221 for corrosion protection of pipes for the underground installation.Note The piping installation has to be put to hydraulic test to1.5 times the working pressure and as per latest applicable codes and standard before applying paint or pipe coating or wrapping etc. complete. Make TATA/JINDAL/SAIL100mm NB
47080mm NB
47125mm NB
472Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C.Make-Zoloto/AUDCO/Leader 100mm NB
473Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/AUDCO/Leader 100mm NB
474Supply,Installation,Testing & Commissioning of orifice plate made of 6mm thick stainless steel with orifice of required size in between flane and landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 Kg/ sq cm complete as required.
475Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.MAKE: H.GURU/G.GURU
476Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.MAKE: DANFOSS/INDFOSS make
477Supply,Installation,Testing & Commissioning of 100 MM stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/AUDCO/Leader
478250mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint as required
479Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
480Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
481Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
482Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
483Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
484Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge.
485Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 100mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Minimax/Newage/Fireshield/Safex
486Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire/Flameklog/Kalpex .4.5 kg capacity
487Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire/Flameklog/Kalpex .6 kg capacity
488Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets.
489Supply & Installation of 8 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.08 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x
490Supply & Installation of 20 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.2 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x
491Supply & Installation of 30 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 0.3 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x
492Supply and installation of linear heat detection cable compatible with aerosol based fire extinguisher as per the direction of Engineer-in-charge. Make-Make-Pyrogen/Firepro/Stat-x
493SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages
494EXTERNAL ILLUMINATIONsystem power of 120W, CCT in 5700K as per ANSI) ,CRI>70, SDCM<3 , LEDs used should have a life of 50,000 burning hrs. & Lumen maintenance as per L70. The Luminaire System lumens should be >=19,200 Lumens @5700K. The fixture housing must be Made of ADC 12 PDC Aluminium housing for rapid thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have a Ingress protection of IP66 and Impact Resistance of IK08. The light engine should use Metal Core PCB with high grade aluminium (AL5052) and should have a thermal conductivity of >2W/mK. The fixture should have an UV stabilized Injection moulded special PC lens optics(Glass not allowed) ensuring low glare & best in class uniformity. The light and the driver compartment should be thermally isolated by a natural airgap. Luminaire housing and optical compartment both should carry OEM's logo embossed / engraved (no stickering is allowed). The luminaire must have Integral encapsulated high efficiency electronic thermally isolated driver having a Aluminium extrusion construction with rated voltage of 100-300V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of min 6KV and upgraded with integrated IP67 protected SPD of 20KV/10KA surge protection with all necessary safety protection like mis-wiring, Over voltage, Short circuit, Reverse Polarity protection. . The compartment should be bottom openable for ease of maintenance at site. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. Following documents to be submitted after award of contract: Luminaire and Driver TDS, Photometry report, Type test certificate, IP, IK, Vibration and salt spray test certificates from NABL accredited Laboratory, LM80 from LED OEM., CE Certification, ROHS compliant, BIS Certificate for Luminaires & Drivers. The warranty on light fixture shall be 5 years. (Make: PHILIPS/WIPRO/BAJAJ/Crompton/PANASONIC/LT/HAVELLS)
495Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee/Valmont as per direction of Engg. in Charge.
496Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative DOUBLE arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee/Valmont as per direction of Engg. in Charge.
497Construction of RCC foundation by using M20 grade RCC and Fe 415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing the 4 nos. fdn bolts in that foundation for installation of pole with street light on that foundation(Details Drawing of the foundation attached). The work shall be excuted as per the direction of EIC.The structural calculation, wind load calculation and civil foundation shall be duly approved by the competent authority from civil wing (SE/CCE/Competant authority)before execution of the work.
498STREET LIGHT: S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 16A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials
499Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.3.5 core x 25 sq mm Aluminium armoured Cable.(FOR street PANEL)
5004 core x 10 sqmm
501Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
502Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
503Supply of Elegant look 60 W AIO LED Solar Street lights having extruded alluminium housing 180Wp or more (subjected to final panel backup calculation with dimming profile of 100 output for 2 hrs 90 output for 1 hr 60 output for 1 hr and 50 output for 8 hrs per day. The calculation is to approved by SE Electrical Circle (RandB) before final procurement of the product.) Mono Crystalline Panel Laminates fixed on the top of the luminaire housing maintenance free 12.8 volts 96 Ah or more (subjected to final battery calculation with dimming profile of 100 output for 2 hrs 90 output for 1 hr 60 output for 1 hr and 50 output for 8 hrs per day. The calculation is to approved by SE Electrical Circle (RandB) before final procurement of the product.) LiFePO4 battery(BIS certified) BMS MPPT charge controller PIR sensor.The solar panel and battery should be designed to provide 2 days (24 hrs ) back up The luminaire is having IP 65 protection for critical components IK 08 and having lumen output of 10000 lumens and having lumen efficacy not less than equal to 167 lm/w) as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output and lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central state govt accredited NABL lab reports to justify the lumen efficacy luminaire output IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their companys letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE Electrical Circle (RandB) for the technical acceptance of the products. 1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 MPPT Efficiency 5. IEC61547 6. IEC61000 3 2 EMC 7. IEC 60598 2 3 ,8. IEC 62109 1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar NB The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. The battery and panel figures are indicative only. Final procurement shall be done after approval of panel and battery backup calculation from Superintending Engineer, Electrical Circle (R&B) Odisha, Bhubaneswar. light ) Make-(Philips/Panasonic/Wipro/Crompton/Bajaj/Havells/LT ).
504Supply of 8 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate and 4 nos. Jtype En 8 grade foundation bolts to withstand 180 KM / HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the pole.The bidder shall also furnish wind load test report of the solar fixture and wind load test of the pole considering the weight and dimension of 1 nos 60 W AIO Solar light to be fitted in the pole to sustain wind speed of 180km/hr or more from third party /central/state govt accredited NABL lab after award of the work.The reports are to be duly approved by the competant authority from civil wing (concerned SE/CCE/Competant authority) before execution of the work.The structural design of the pole foundation shall be approved by concerned civil wing(SE/CCE/Competant authority) before execution of the work. (Make - Bajaj/RR ispat//Valmont/Vakrangee/Utkarsh/Equivalent)
505Construction of RCC foundation by using M20 grade RCC and Fe 415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing the 4 nos. fdn bolts in that foundation for installation of pole with Solar light on that foundation (Details Drawing of the foundation attached). The work shall be excuted as per the direction of EIC.The structural calculation, wind load calculation and civil foundation shall be duly approved by the competent authority from civil wing (SE/CCE/Competant authority) before execution of the work.
506Installation of 8 mtr pole on the adaptor plate/ foundation after fixing the 60 W AIO Light in the pole by using suitable machinery by taking all safety precautions as per the direction of EIC.
507External CCTVSITC of outdoor type double jacketed 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA 568 C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from 20 to 70 C Cable support Conductor Resistance 9.38 100m Max., Cable support Delay Skew 45 ns/100m, Operating Voltage 72V , Impedance 100 15 100 MHz. and Propagation Delay 250 MHz 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make Systimax, Legrand, Panduit.
508SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
509SITC of Cat6 UTP 23 AWG Patch Cord Patch cord 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA 568 C.2 Standard. Supports Data Networks Speeds Up to 10/100 Base T and 1000 Base T. Available In LSZH Jacket Reduced Toxic Gasses Emitted During Combustion RJ45, 8P8C, 2 FORK 50 Gold Plated Contacts , 100 Factory Tested , Transparent Boot Cable Assemblies. Make Systimax, Legrand, Panduit(1 mtr length)
510SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
511SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19 ,Dimensions (mm) 430 X 220 X 1U Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR 326 Core . Make Systimax, Legrand, Panduit
512SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
513SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear
514SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 380W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear
515SITC of 9U/500D outdoor type IP67 fLOOR Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
516Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low Light IR Fixed Lens Dome/Bullet Camera, 1/2.8 CMOS or better, 5MP (2592 x 1944) 25fps or better, four stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 1/100,000 Adavance Video Compression technology such as H.265 HEVC H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5 V 73.8 (dome)/ Field of View FoV H 94.1 V 71(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics Video Motion Detection, Tampering, Loitering, Intrusion, and People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES 128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 and IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range 30 C to 60 C. Certifications ONVIF Profile S/G/T compliant,, CE (EN 50130 4), FCC Part 15, EN 55032 and RoHS (EN63000),NDA,STQC compliant. Make Honeywell Value series/Pelco/Axis/Bosch
517Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low Light IR motorized Lens Dome/Bullet Camera, 1/2.8 CMOS or better, 5MP (2592 x 1944) 25fps or better, four stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 1/100,000 Adavance Video Compression technology such as H.265 HEVC H.264 / MJPEG , Fixed Lens 2.7 13.5mm motorized, Field of View FoV H 100-28.5 V 73-21.4 BLC, HLC, WDR, 2D/3DNR, White Balance Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES 128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 and IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range 30 C to 60 C. Certifications ONVIF Profile S/G/T compliant CE (EN 50130 4), FCC Part 15, EN 55032 and RoHS (EN63000),NDA,STQC compliant. Make Honeywell value series/Pelco/Axis/Bosch
518Supply Installation Testing and Commissioning of 7.5 kVA, single phase hybrid Solar Photovoltaic Power Plant,08 NOS. 150Ah C10 Solar tubular battery, 550W ,14 nos. solar panel conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT bifacial Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 550Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 22%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years
519Maintenance (Civil and PH items) -Internal Work-A) First year-(A) Routine maintenance of all civil structure and sports facilities constructed including labour & materials for all Civil works for 5 years including all types of minor repairof flooring, plastering ,door windows ,celling, coloring the entire structure both internal and external etc as per standard maintenance procedure , codal provision andspecifications, special conditions, additional conditions etc. and as per agreement provisions to complete repair work as per direction of Engineer-in-charge.
520B) Second year-
521C) Third year-
522D) Fourth year-
523E) Fifth year-
524Maintenance (Civil and PH items) -External Work-A) First year-(A) Routine maintenance of all civil structure and sports facilities constructed including labour & materials for all Civil works for 5 years including all types of minor repairof flooring, plastering ,door windows ,celling, coloring the entire structure both internal and external etc as per standard maintenance procedure , codal provision andspecifications, special conditions, additional conditions etc. and as per agreement provisions to complete repair work as per direction of Engineer-in-charge.
525B) Second year-
526C) Third year-
527D) Fourth year-
528E) Fifth year-
529Maintenance (Electrical items) -Internal work-A) First year-(B) Routine inspection and preventive maintenance of main LT panels, sub-distribution boards, MCC panels,and control panels, checking of internal wiring circuits for lighting, power, and specialized medical equipment, regular maintenance of internal lighting (general and emergency), corridor and ward lights, and external compound lighting, operation and maintenance of DG sets, automatic changeover panels, and UPS systems for critical medical areas , periodic testing of earthing pits and recording resistance values, replacement of damaged switches, fuses, indicators, damaged wires, damaged light, driver as required. Cleaning of filters, cooling coils, drain trays, checking refrigerant levels, compressor condition, and electrical controls, cleaningof air ducts, grills, and diffusers to maintain hygiene standards and air quality, operation and maintenance of exhaust fans, fresh air units, and ventilation systems in toilets, laboratories, and isolation wards, supply and replacement of consumables like filters, belts, bearings, lubricants, etc., as per schedule. Deployment of qualified and licensed electricians and trained HVAC
530B) Second year-
531C) Third year-
532D) Fourth year-
533E) Fifth year-
534Maintenance (Electrical items) -External work-A) First year-(B) Routine inspection and preventive maintenance of main LT panels, sub-distribution boards, MCC panels,and control panels, checking of internal wiring circuits for lighting, power, and specialized medical equipment, regular maintenance of internal lighting (general and emergency), corridor and ward lights, and external compound lighting, operation and maintenance of DG sets, automatic changeover panels, and UPS systems for critical medical areas , periodic testing of earthing pits and recording resistance values, replacement of damaged switches, fuses, indicators, damaged wires, damaged light, driver as required. Cleaning of filters, cooling coils, drain trays, checking refrigerant levels, compressor condition, and electrical controls, cleaningof air ducts, grills, and diffusers to maintain hygiene standards and air quality, operation and maintenance of exhaust fans, fresh air units, and ventilation systems in toilets, laboratories, and isolation wards, supply and replacement of consumables like filters, belts, bearings, lubricants, etc., as per schedule. Deployment of qualified and licensed electricians and trained HVAC
535B) Second year-
536C) Third year-
537D) Fourth year-
538E) Fifth year- Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56698041
AUTHORITY Government Departments
TENDER VALUE 7.93 Crore
LAST DATE 13-08-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Construction Of Block Level Stadium (Without Indoor Hall) In Ranpur Block Under Nayagarh District
Basic Detail
Tender No CCE-05/2026-27
Bidding Type Tender
Location
City Nayagarh
State Odisha
Key Dates
Publish Date 28 Jul 2026
Submission Date 13 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 7.93 Crore
Tender Fee 10000
EMD 7.94 Lakhs
Exemption Available
Document List
BOQ_603551.xls
da659b67-7b2a-4ee6-8861-a2506ed9a6e0.html
Tendernotice_1 (10).pdf
Tendernotice_2 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_603551.xls

html

da659b67-7b2a-4ee6-8861-a2506ed9a6e0.html

pdf

Tendernotice_1 (10).pdf

pdf

Tendernotice_2 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders