Tender For Infrastructure Development At Chc. Botalama Under Ama Hospital Building In The District Of Khordha

Issued by Government Departments · Khordha, Odisha
Tender Value
3 Crore
Estimated cost
Bid Submission
13 Aug 2026
15 days left
EMD
3.01 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Infrastructure Development At Chc. Botalama Under Ama Hospital Building In The District Of Khordha

BOQ

Name of Work:- Infrastructure Development at CHC. Botalama under AMA Hospital Building in the District of Khordha
Sl. No. Item Description
1CIVIL WORK Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.Ground Floor
2Earth work in Ordinary soil with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth and the Earth transported by transport vehicles as directed by the Engineer in charge.Ground Floor
3Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer In charge.
4Diluting and injecting chemical emulsion for PRE CONSTRUCTIONAL Anti termite treatment and creating a continuous chemical barrier under and all round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated sorroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
5Disposal of Surplus Earth/Debris staked at work site by mechanical means including loading and unloading and disposing the same within a lead of 5 km with hire running charges of all machineries, cost of all labour, labour cess, T&P required for the work etc. complete as directed by Engineer In Charge.
6Supplying and filling in foundation and plinth with sand including watering and ramming, poking and compacting including cost, conveyance, royalties, taxes of the materials and cost of all labour, labour cess, T&P etc. required for the work complete as directed by the engineer in charge.Ground Floor
7Providing and laying Plain Cement Concrete of proportion (1:3:6) using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including the cost of all materials, cost of labour, conveyance, taxes, royalties, loading, unloading, shuttering, centering, curing, labour cess, T&P, etc. all complete as per the direction of engineer in charge.Ground Floor
8Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Foundation and Footing Bases of Columns Mass Concrete Pre Cast Slab etc.Ground Floor
9Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Grade Beams,Ground Floor
10Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Columns & Roof Beams,Ground Floor
11Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Columns & Roof Beams,First Floor
12Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Lintels,Ground Floor
13Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Lintels,,First Floor
14Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Chajja,Ground Floor
15Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Chajja,First Floor
16Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Shelve,Ground Floor
17Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Stair Case,Ground Floor
18Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Floor and Roof Slab, Landing, Balconies, Projecting Sun Shades and Chajjas up to 4.3 Mtr. Height.Ground Floor
19Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,R.C.C. Floor and Roof Slab, Landing, Balconies, Projecting Sun Shades and Chajjas up to 4.3 Mtr. Height.,First Floor
20Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,RCC Drain Slab
21Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M 20 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer in charge but excluding the cost of steel reinforcement.,RCC Drain Wall
22Cutting, Straightening, coiled or bent up MS Road of TOR steel using SAIL/RINL/TATA/JINDAL/SHYAM Steel including bending, binding,welding and joining if necessary and tying the grills and placing in position as required for RCC work and hoisting, lowering laying icluding cost, conveyance, taxes of MS rod or TOR steel and binding wire of 18 to 20 gauge and labour required for the work for bending,binding and tying the grills etc. complete.Ground Floor
23Cutting, Straightening, coiled or bent up MS Road of TOR steel using SAIL/RINL/TATA/JINDAL/SHYAM Steel including bending, binding,welding and joining if necessary and tying the grills and placing in position as required for RCC work and hoisting, lowering laying icluding cost, conveyance, taxes of MS rod or TOR steel and binding wire of 18 to 20 gauge and labour required for the work for bending,binding and tying the grills etc. complete.,Terrace Floor
24Providing Fly Ash Brick masonry work in F&P using Fly Ash Bricks of size 250mm x 120mm x80mm having crushing strength not less than 75Kg/Sqcm in cement mortar (1:6) including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, labour cess, scaffolding, curing for required period, T&P, etc. all complete as per the direction of the engineer in charge.Ground Floor
25Providing Fly Ash Brick masonry work in Superstructure using Fly Ash Bricks of size 250mm x 120mm x80mm having crushing strength not less than 75Kg/Sqcm in cement mortar (1:6) including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, labour cess, scaffolding, curing for required period, T&P, etc. all complete as per the direction of the engineer in charge.Ground Floor
26Providing Fly Ash Brick masonry work in Superstructure using Fly Ash Bricks of size 250mm x 120mm x80mm having crushing strength not less than 75Kg/Sqcm in cement mortar (1:6) including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, labour cess, scaffolding, curing for required period, T&P, etc. all complete as per the direction of the engineer in charge.,First Floor
27Providing Fly Ash Brick masonry work in Superstructure using Fly Ash Bricks of size 250mm x 120mm x80mm having crushing strength not less than 75Kg/Sqcm in cement mortar (1:4) with provision for two no.s of 6 mm dia after each 4th layer. including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, labour cess, scaffolding, curing for required period, T&P, etc. all complete as per the direction of the engineer in charge.Ground Floor
28Providing 12 mm thick cement plaster in cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats with proper plumbs and level including the cost of all materials, labour, conveyance, taxes, loading and unloading, labour cess, royalties, scaffolding, watering and curing, T&P etc. complete as per direction of the engineer in charge.Ground Floor
29Providing 12 mm thick cement plaster in cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats with proper plumbs and level including the cost of all materials, labour, conveyance, taxes, loading and unloading, labour cess, royalties, scaffolding, watering and curing, T&P etc. complete as per direction of the engineer in charge.First Floor
30Providing 12mm thick Cement Plaster in Cement Mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer in charge.Ground Floor
31Providing 16 mm thick cement plaster in cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats with proper plumbs and level including the cost of all materials, labour, conveyance, taxes, loading and unloading, labour cess, royalties, scaffolding, watering and curing, T&P etc. complete as per direction of the engineer in charge.Ground Floor
32Providing 16 mm thick cement plaster in cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats with proper plumbs and level including the cost of all materials, labour, conveyance, taxes, loading and unloading, labour cess, royalties, scaffolding, watering and curing, T&P etc. complete as per direction of the engineer in charge.First Floor
33Providing 6 mm thick cement plaster in cement mortar of (1:4) to RCC work including roughening, scraping, cleaning and finishing the plastered surface smooth using wooden floats with proper plumbs and level including the cost of all materials, cost of labour, conveyance, loading and unloading, all taxes and royalties, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer in charge.Ground Floor
34Providing 6 mm thick cement plaster in cement mortar of (1:4) to RCC work including roughening, scraping, cleaning and finishing the plastered surface smooth using wooden floats with proper plumbs and level including the cost of all materials, cost of labour, conveyance, loading and unloading, all taxes and royalties, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer in charge.,First Floor
35Finishing the wall surface with Acrylic wall putty (water based) of approved make and finishing smooth even surface to receive painting including cost of all T&P and materials etc complete and as per specification and direction of the Engineer in Charge.Ground Floor
36Finishing the wall surface with Acrylic wall putty (water based) of approved make and finishing smooth even surface to receive painting including cost of all T&P and materials etc complete and as per specification and direction of the Engineer in Charge.,First Floor
37Priming over the plastered surface with one coat of water bound cement primer of approved quality and make including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of engineer in charge.Ground Floor
38Priming over the plastered surface with one coat of water bound cement primer of approved quality and make including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of engineer in charge,First Floor
39Providing and painting with two coats of Weather Coat of approved quality, make and shade to give an even surface including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete.Ground Floor
40Providing and painting with two coats of Weather Coat of approved quality, make and shade to give an even surface including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete.,First Floor
41Providing & Painting with two coats of Plastic emulsion paint of approved quality, make and shade to give an even surface including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete.Ground Floor
42Providing and Painting two coats of synthetic enamel paint of approved quality, make and shade on Iron / Wood Works over one coat of primer including the cost of sand papering, surface polishing, cost of all materials, cost of labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. as per direction of engineer in charge.Ground Floor
43Supplying, fitting and fixing Vitrified Tiles in floors of size 600mm x 600mm (Plain/Ivory) of approved make confirming to IS:13755 laid on 20mm thick cement mortar (1:4) (1 cement : 4 Course Sand) and filling joints with white cement of approved quality including cost, conveyance, taxes, cost of all labour, labour cess, etc. all complete.Ground Floor
44Supplying, fitting and fixing vitrified tiles in dados, skirting and risers of steps on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with colouring pigments to match the colour and shade including the cost of washing, polishing, cost of materials, cost of all labour, conveyance, taxes, loading & unloading, T&P, watering and curing etc. complete.Ground Floor
45Supplying, fitting and fixing of 10 mm thick Granite stone in dados/skirting using granite stone of approved quality,colur and size over 12mm thick cement mortar (1:3) including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade,machine grinding, cleaning with oxalic acid, mirror polishing the surface including cost of all labour, materials, taxes, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer in Charge.Ground Floor
46Providing & laying granite stone flooring using 20 mm thick granite stone of approved quality, colour and size in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials, taxes, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer in Charge.Ground Floor
47Supplying and fixing GCI sheeet on roof drilling hole in wind ties including fixing of ridges valley wind ties etc excluding cost of fittings etc complete.
48Providing and fixing 35mm thick flush door shutters made out of 32mm thick BWR Block Board including the cost of hardware fittings like 125mm MS Butt Hinges, 250mm MS Aldrop, 150mm MS Handle, 150mm MS tower bolt, door stopper, Cost of labour, coveyance, taxes, loading, unloading, T&P, etc. all complete.Ground Floor
49Supplying, fitting and fixing of MS. doors/windows/grill gate made out of square bars, angle, channel, flat, plate, Hollow Pipes, etc painted with red oxide primer cost of all materials, labour, conveyance, taxes, loading, unloading, T&P, etc. all complete.Ground Floor
50Labour charges for fitting, fixing M.S. gates (M.S. Door, Window with grills, Grills, collapsible gates) as per approved design including cost of all labour, T&P etc. complete.
51Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.Ground Floor
52Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer in charge.Ground Floor
53Providing and laying 25mm thick grading Concrete of proportion (1:2:2) using 6mm size crusher broken black hard granite chips from approved quarry, scraping and cleaning the surface, fininishing smooth to proper slope and gradient including cost of all materials, cost of labour, conveyance, taxes, loading, unloading, curing,T&P, etc. all complete as per the direction of the engineer in charge.Ground Floor
54Providing and laying 25mm thick grading Concrete of proportion (1:2:2) using 6mm size crusher broken black hard granite chips from approved quarry, scraping and cleaning the surface, fininishing smooth to proper slope and gradient including cost of all materials, cost of labour, conveyance, taxes, loading, unloading, curing,T&P, etc. all complete as per the direction of the engineer in charge.,First Floor
55Providing and laying Plain Cement Concrete of proportion M 20 Grade using 20mm to 10mm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including the cost of all materials, cost of labour, conveyance, taxes, royalties, loading, unloading, shuttering, centering, curing, labour cess, T&P, etc. all complete as per the direction of engineer in charge.
56Earth work in all kind of soil with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth and the Earth transported by transport vehicles as directed by the Engineer in charge.
57Loosening, Levelling & compacting original ground supporting to Embankment scarified to a depth of 150mm mixed with water at OMC & then Compacted by rolling to achieve minimum dry density as per Specifications.
58Construction of granular sub base by providing close graded Grading VI material of table 400 1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density including cost of all materials, cost of labour, conveyance, taxes, loading, unloading, T&P, etc. all complete as per the clause of MoSRT&H specification for road and bridge work.
59Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works (4th Revision).
60Supplying and fixing of 80mm thick cement concrete interlocking paver block of M 40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP 63:2018.
61Supplying, Fitting & Fixing of Precast Kerb Stone of size 600x300x150mm of M 30 Grade Design & size made by Block making machine with Proper Compaction fixed in required Pattern complete in all respect confirming to IS 5758 1984.
62Scrapping the wall surface and removing the old paint manually as per necessity preparing the surface by washing with soap water etc.Engineer in charge.
63Dismantling & removing old damaged tile from Floor / walls and removing the debris away from work site after stacking the useful materials for reuse as per direction of the Engineer in charge.
64Dismantling & removing old damaged Grading Concrete from roof including racking out joints and removing the debris away from work site within 50m. lead etc. complete as per direction of the Engineer in charge.
65Dismantling & removing old damaged A.C. / GCI sheet from roof and removing the debris away from work site after stacking the useful materials for reuse as per direction of the Engineer in charge.
66Dismantling & removing old damaged Grill and removing the debris away from work site after stacking the useful materials for reuse as per direction of the Engineer in charge.
67Dismantling old damaged Door, Window shutter, and Ventilator removing the debris away from the work site after stacking the useful materials for reuse as per direction of the Engineer in charge.
68Supplying, Fitting &Fixing of two track UPVC Sliding Window of approved make with 6mm thick glass of approved quality complete with frame, shutters all fitting & fixtures all comp.
69Supplying, Fitting &Fixing of UPVC Openable Door of approved make with 6mm thick glass of approved quality complete with frame, shutters all fitting & fixtures all comp.
70Proding fitting & fixing of false ceilling with Aluminium anodised T Section No. 3215 with 2 0 center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2 0 x2 0 suspended from ceilling etc. complete. (As per A.R. 237/3)
71Supplying fitting fixing of M.S Tabular Roofing member approved Quality in proper position including cost of all materials labour T&P etc complete.
72Dismantling and removing damaged cement concrete including stacking the usefull materials for reuse and removing the debris within 50 M lead.
73Dismantling brick or stone masonry in lime or cement mortar above 3.0M height including stacking the usefull materials for reuse and removing the debris within 50 M lead.
74Dismantling and removing RCC Columns, beams, slabs, staircase, landing, lintel, etc. including stacking the usefull materials for reuse and removing the debris within 50 M lead.
75Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead
76PH WORK Supplying all materials, labour, T&P and Providing and fixing Chlorinated Polyvinyl Chloride (CPVC/UPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (Supreme/Ashirvad/Oriplast/Shaakya)In ground floor = 20mm dia C PVC pipes
77Supplying all materials, labour, T&P and Providing and fixing Chlorinated Polyvinyl Chloride (CPVC/UPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (Supreme/Ashirvad/Oriplast/Shaakya),25mm dia C PVC pipes
78Supplying all materials, labour, T&P and Providing and fixing Chlorinated Polyvinyl Chloride (CPVC/UPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (Supreme/Ashirvad/Oriplast/Shaakya),25mm dia UPVC ASTM D pipes
79Supplying all materials, labour, T&P and Providing and fixing Chlorinated Polyvinyl Chloride (CPVC/UPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (Supreme/Ashirvad/Oriplast/Shaakya),32mm dia UPVC ASTM D pipes
80Supplying all materials, labour, T&P and Providing and fixing Chlorinated Polyvinyl Chloride (CPVC/UPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (Supreme/Ashirvad/Oriplast/Shaakya),32 mm dia HDPE Pipe
81Supplying all materials, labour, T&P and Providing and fixing Chlorinated Polyvinyl Chloride (CPVC/UPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (Supreme/Ashirvad/Oriplast/Shaakya),,40mm dia UPVC ASTM D pipes
82Supplying all materials, labour, T&P and Providing and fixing Chlorinated Polyvinyl Chloride (CPVC/UPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (Supreme/Ashirvad/Oriplast/Shaakya),,In 1st. Floor 50mm dia UPVC ASTM D pipes
83Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.,In ground floor 250mm thick wall
84Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge,In ground floor 250mm to 375mm thick wall.
85Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.,In ground floor
86Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge,15mm dia long body Bib Cock cock (Jaquar) CON CHR 107KN
8715mm dia CP angle stop cock (FLR ACR 5053N)
8815mm dia CP Pillar cock (Jaquar)CON CHR 021KN
89HAND SHOWER (HEALTH FAUCET) WITH 1 METER (Jaquar ALD CHR 565
9015mm dia Two way Bib Cock (Jaquar) CON CHR 041KN
9125mm dia brass or gun metal full way valve(shakti make)
9232mm dia brass or gun metal full way valve(shakti make)
9340mm dia brass or gun metal full way valve(shakti make)
9450mm dia brass or gun metal full way valve(shakti make)
9515mm dia CP Flange
9615mm dia CP Extention Nipple
97125mm CP grating
98Supplying all materials, labour, T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701 1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge,2000 Ltr PVC water storage tank (3 Layer White) on 1nd. Floor
99Supplying all materials, labour, T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701 1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge,500 Ltr PVC water storage tank (3 Layer White) on 1nd. Floor
100Supplying all materials, labour, T&P and fixing Wash Down Water Closet (European type W.C pan) with integral S or P trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification and direction of the Engineer in charge,E.W.C. S trap plain (Parryware/Hindware/Neycer)
101Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci P or S trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer in charge. 580mmx440mm size Orissa pan ((Parryware/Hendware/Cera/Somany/Kerovit)
102Supplying all materials, labour T&P and and fixing 10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main etc all complete as per the specification and direction of the Engineer in charge,10 litres capacity PVC LL cistern (Parryware/Hindware/Neycer)
103Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771 part 3 1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar/Parryware / Hindware make). URS WHT 13253N Urinal (Back Inlet)
10415mm dia urinal spreader
10532mm dia C.P. dome waste
106Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556 part 4 2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge Under Counter Basin (560x455) (H)10095 white
107550mmx400mm size Wash hand basin with Porcelain Pedestal (Parryware/Hindware/Neycer)
108Supplying all materials, labour, T&P and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast/Shaakya),110mm dia U PVC SWR pipe
10975 mm dia UPVC SWR Pipe
110110mm U PVC Door Tee
111110mm U PVC Plain Tee
112110mm U PVC Door Bend
113110mm U PVC Plain Bend
114110mm dia U PVC 45o bend
115110mm dia U PVC P trap
116110mm U PVC Cowl.
11775 mm dia UPVC plain bend (supreme/ashirvad)
11875 mm dia UPVC plain Tee (supreme/ashirvad)
119PVC clamp suitable for 75 mm to 110mm dia pipe
120Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail
121CP Towel ring
122Supplying all materials ,labour ,T&P and fixing CP Soap Holder complete with CP brass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as per specification and direction of Engineer in charge. CP soap holder
123Supplying all materials, labour, T&P and fixing standard sized glass shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge.600mmx125mm glass shelf with CP/NP guard rails
124Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438 1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware)
125Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 80 PSS UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge.
126Supplying all materials,labour,T&P and dismantling the damaged squatting type water closet and urinal plates etc and mending good the damages to the floors and removing the debris at a safe distance as per direction of the Engineer in charge.Squatting type water closet
127Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking of the useful materials for reuse and removing the debris within 50 m lead etc all complete as per specification and direction of the Engineer in charge.
128Dismantling and removing old tile flooring including stacking the useful materials for reuse and removing the debris within 50 m lead etc all complete as per specification and direction of the Engineer in charge.
129Dismantling and removing old tile dado from walls including racking out joints 12mm deep and removing the debris within 50 m lead etc all complete as per specification and direction of the Engineer in charge.
130Dismantling and removing old lime or cement plaster from walls including racking out joints 12mm deep and removing the debris within 50 m lead etc all complete as per specification and direction of the Engineer in charge
131Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV TIFAC composites Design Centre s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type I(ISI marked) size 100mm are to be fitted on one side of shutter.
132Factory made Solid WPC door frame of size 95mmx55mm fabricated. The door frame consist of four segments which are provided with plug in socket arrangement in situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
133Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etcall complete as per direction of the Engineer in charge.
134Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer in charge
135Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chipsincluding watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
136Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.
137Supplying all materials, labour, T&P and providing Ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete. Size 600mmx600mm (Kajaria / Somany / Johnson/Equivalent) to be pre approved by the Engineer in charge.
138Supplying all materials, labour, T&P and fixing Porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete. Size 600mmx300mm (Kajaria / Somany / Johnson/Equivalent ) plain/printed to be pre approved by the Engineer in charge.
139Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge,Gully trap chamber of size 250mmx250mm with R.C.C cover slab
140Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge,Inspection chamber Inside size 760mmx760mmx460mm
141RCPC Cover (18 round)
142Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge,Man hole chamber Inside size 910mmx910mmx910mm
143RCPC Cover (24 round)
144Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit
145Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class 3(0.60mpa) including jointing with supply of approved solvent cement by non heat application method/as per manufacturer s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C 1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.,110mm dia u pvc pipe alround concrete
146160mm dia u pvc pipe alround concrete
147Construction of 50 users RCC septic tank 1 No ,Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in Charge.
148Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. 1x6.10x2.70x0.30
149Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department.
150Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
151Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
152Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
153Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
154Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge,R.C.C floor and roof slabs up to 4.30m height
155R.C.C beams,columns,girder and bressmer etc.
156Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
157Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
158Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
159Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
160Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge,In F&P
161Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
162Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
163Supplying all materials, labour,T&P and providing 25mm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips on new work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
164Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
165Dewatering with 5 H.P diesel engine pump during excavation
166Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 150mx150mx150m as per P.H.D.specification and direction of the E.I.C.
167Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
168Supplying all materials, labour, T&P and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non heat application method/as per manufacturer s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. ,110mm diameter U PVC SWR pipes(Supreme/Ashirvad)
169110mm U PVC cowl
170EI WORK Sub Head I (modular Wiring Items),Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make Schneider(Zencelo)/legrand( Myrius NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make Schneider(Zencelo)/legrand( Myrius NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP A
171Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make Schneider(Zencelo)/legrand( Myrius NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make Schneider(Zencelo)/legrand( Myrius NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP B
172Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make Schneider(Zencelo)/legrand( Myrius NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make Schneider(Zencelo)/legrand( Myrius NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. ,GROUP C
173Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. in Charge. Make Schneider(Zencelo)/legrand( Myrius NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
174Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg in charge..Make Schneider(Zencelo)/legrand( Myrius NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
175Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg in charge.. Make Schneider(Zencelo)/legrand( Myrius NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
176Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg in charge..Make Schneider(Zencelo)/legrand( Myrius NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
177Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg in charge. Make Schneider (Zencelo)/ legrand( ( Myrius NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
178Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
179Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
180Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
181Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
182Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)
183Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
184Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg. in Charge .Make AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV) 20 MM
185Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg. in Charge .Make AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV) 25 MM
186S/F of 16 amps, modular socket, ISI marked
187Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage 230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg. in Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
188Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make Havells/Anchor as required as per direction of Engg. in Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
189S/F of Bakelite angle holder/batten holder (make Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS 1258/1987 in place of ceiling rose as per direction of Engg. in Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
190Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg. in Charge. Replacement Warranty will be 2 years.
191Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg. in Charge. Replacement Warranty will be 2 years.
192Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3/min Make Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg. in Charge,Replacement Warranty will be 4 years.(With fan Regulator)
193Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die cast Alluminium housing with high quality frosted diffuser for glare free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg. in Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
194Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 25W and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700 6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140 270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty)supply .as required as per direction of Engg. in Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2 years.
195Supplying, installation, testing and commssioning of 400 mm sweep white/milky colour wall fan Make Crompton /Havells /Polar Winpro ) including wiring with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg. in Charge,Replacement Warranty will be 4 years.. .
196Supplying an fixing of recess/surface mounted 2 x2 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700 6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg. in Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years.
197SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 40 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg. in Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
198Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg. in Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
199Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439 3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make LEGRAND Ekinox3 DB/ Siemens Betaguard/ Schneider Acti 9 /ABB ITUS as per direction of Engg. in Charge. 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439 3 with configuration of incomming I 8 modules,sub incommer 12 module & out going 12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43 IK09 with metal door Warranty on DB is 3 years
200Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
201Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439 3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make LEGRAND Ekinox3 DB/ Siemens Betaguard/ Schneider Acti 9 /ABB ITUS as per direction of Engg. in Charge. . 8Way(8+(4x3)+(8x3)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439 3 with configuration of incomming I 8 modules,sub incommer 12 module & out going 24 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43 IK09 with metal door Warranty on DB is 3 years
202Supplying and fixing 25Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make LEGRAND DX3/ Siemens Betaguard/ Schneider Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg. in Charge. The MCB should be Replacement Warranty will be 3 years.
203Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make LEGRAND DX3 / Siemens Betaguard/ Schneider Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg. in Charge. .Warranty on MCB is 1 years.
204Supplying and fixing 6 32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make LEGRAND DX3 / Siemens Betaguard/ Schneider Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg. in Charge. .. The MCB should be Replacement Warranty will be 1 years..
205Supplying and fixing 63Amps 4P 415 volts MCB Make LEGRAND DX3 / Siemens Betaguard/ Schneider Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg. in Charge..Warranty on MCB is 1 years.
206Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec 50kA,with response time<25 nanosec in the incommer of Distribution board, Make LEGRAND DX3 / Siemens Betaguard/ Schneider Acti 9 in the existing MCB DB with connections as per direction of Engg. in Charge.The SPD should have Replacement Warranty will be 1 years.
207Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer in charge.
208Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg. in Charge.
209Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg. in Charge. 2core x 10 sq mm
210Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg. in Charge. 2core x 6 sq mm
211Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg. in charge.
212Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg. in Charge. 2core x 10 sq mm
213Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg. in Charge. 2core x 6 sq mm
214Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg. in Charge. 50 mm dia
215MAIN CONTROL PANEL S/I/T&Commissioning of CPRI tested 16/ 18 SWG panel box 2x(36x36)+(15x36)+(36x15) sq. inchLT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg. in Charge.Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.
216Provision of internal wiring to equipment installed in the pannel board with required size of copper multistrand single core cables duly crimped with copper lugs and all connections 2x(36x36)+(15x36)+(36x15) including cost of copper conductor and other fittings like gasket ,screw , nut and bolt , insulating materials etc.
217In commer 2 01 number of 250A 4P Icu=100%Ics,25kA LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make LEGRAND DPX3 / Siemens 3VA Model/ Schneider CVS) (DG 160 KVA INCOMMER)
218In commer 2 01 no of 160A 4P onload changeover switch ( DG 01 NO)(Make HPL/L&T/Siemens/Schneider)
219Busbar 1&2 04 numbers of 400Amps copper busbar with 1.6A/SQ.MM current carring capacity. 25mm X 5mm busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)
220Out going 2 numbers of 63A rating,25 KA breaking capacity, 4P MCCB with micro processor based release Electrical locking for normal (Make LEGRAND DX3/ Siemens Betaguard/ Schneider Acti 9)
221Out going 1 numbers of 63A rating,10 KA breaking capacity,C series, DP MCB (Make LEGRAND DX3/ Siemens Betaguard/ Schneider Acti 9)
222Out going 2 numbers of 63A rating,10 KA breaking capacity,C series, 4P MCB (Make LEGRAND DX3/ Siemens Betaguard/ Schneider Acti 9)
223Instrument (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.
224S/F of CT Coil
225SITC of digital type multifunction meter for voltage,current,frequency,PF,THD indication with COMPACTIVITY FOR bms data.
226SITC of 16/ 18 SWG feeder panel box 2x(36x24)+(15x36)+(24x15) sq. inch for double door made out of CR sheet of 16/ 18 SWG and boarder angle frame to provide above pannel with proper space ,hinges, and other accessories , hinged door etc. with powder coating for external street light
227Provision of internal wiring to equipment installed in the pannel board with required size of copper multistrand single core cables duly crimped with copper lugs and all connections 2x(36x36)+(15x36)+(36x15) including cost of copper conductor and other fittings like gasket ,screw , nut and bolt , insulating materials etc.
228Supplying and laying 25mm X 5mm copper strip on surface or in recess for connection etc as required.
229S/F of CT Coil
230S/F of Indicator lamp with trangular switch
231S/F of Kitkat (porcelain fuse carrier and base ISI Marked) (Make Havells/ L&T/ Or equivalent) 400A/ 415V
232Supply and fixing of 400A 50KA DPX3 4pole MCCB with Thermal Mangnetic Protecton unit in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required.(Make Legrand/ Hager/ Simens/ schneider)equivalent)as per direction of Engineer in charge
233POWER BACKUP: S/F of 1750VA inverter (Make Microtek/Equivalent)as per direction of Engineer in charge)
234S/F of 220Ah inverter Battery with platic container (Make Exide/Equivalent as per direction of Engineer in charge)
235Supply of 12.5 mtr LED High mast suitable for 180km/hr wind speed and suitable for maunting maz 06 nos of luminaries and consisting of following accessories. Head frame mobable lantern carriage Double Drum winch6mm 304 grade S.S Hoisting ropes of 7/19 constructiontrailing cable 5 core X 2.5 sqmm 1 per mast (round) Foundation bolts & nutsAnchor plate & templateLighting finalTwin aviation light (GLS Type)Power tool (integral)
236Supply of 1 X 200W LED Flood light (Make Bajaj/ Philips/Crompton)
237Feeder pillar for autometic operation
238Design & Consting of suitable foundation with concrete for 12.5 mtr LED High Mast including installation & commissioning
239Erection of high mast
240Supply of laying of 16sqmm X 4 core cable with 1.15 G.I. Pipe (Approx 65mtr)
241S/F of Street light 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty)
242Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge.
243Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge.
244Supply of Elegant look 60 W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of 10000 lumens and having lumen efficacy not less than equal to160 lm/w) as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company s letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 MPPT Efficiency , 5. IEC61547 , 6. IEC61000 3 2 EMC , 7. IEC 60598 2 3 ,8. IEC 62109 1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make (Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect.
245Supply of 6 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate 260x260x16 mm and 4 nos. Jtype En 8 grade foundation bolts (M24X750 mm) to withstand 180 KM / HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the top of the pole .The bidder shall also furnish wind load test report of the solar fixture and wind load test of the pole considering the weight and dimension of 1 no 60 W AIO Solar light to be fitted in the pole to sustain wind speed of 180km/hr or more from third party /central/state govt accredited NABL lab after award of the work.(Make Bajaj/RR ispat//Valmont/Vakrangee/Utkarsh)
246Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade POLYCAB/KEI/HAVELLS/Gloster/Finolex/RR Kabel of following size cables as per direction of Engg. in Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials 4core x 16 sq mm
247Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade POLYCAB/KEI/HAVELLS/Gloster/Finolex/RR Kabel of following size cables as per direction of Engg. in Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials4core x 6 sq mm
248Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg. in charge.
249Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg. in Charge. 4core x 16 sq mm
250Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg. in Charge. 4core x 6 sq mm
251Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg. in Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make POLYCAB/KEI/HAVELLS/Gloster/Finolex/RR Kabel
252Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg. in Charge. 32mm
253S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg. in Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials
254FIRE SUPPRESSION SYSTEMSupply & Installation of 60 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 0.6 m3) , EN 15276 1:2019 and EN 15276 2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non corrosive, non conductive, non toxic, activation temperature 70 deg 180 deg Celcius including all accessories as per the direction ofEngineer in Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. Replacement warranty on the product shall be 3 years and shell life of 10 years. Make Pyrogen/Genefire/Stat x/Equivalent
255Supply and installation of linear heat detection cable compatible with aerosol based fire extinguisher as per the direction of Engineer in charge. Make Pyrogen/Genefire/Stat x/Equivalent
256ELV WORKSSITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA 568 C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from 20° to 70°C Cable support Conductor Resistance 9.38 /100m Max., Cable support Delay Skew: 45 ns/100m, Operating Voltage: 72V , Impedance: 100 15 @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit
257SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold 0.8.The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94 V O certified. Make: Systimax, Legrand, Panduit
258SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold 0.8 . The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94 V O certified. Make: Systimax, Legrand, Panduit
259SITC of Cat 6, 24 port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
260SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA 568 C.2 Standard. Supports Data Networks Speeds Up to 10/100 Base T and 1000 Base T. Available In LSZH Jacket Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50 Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length)
261SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA 568 C.2 Standard. Supports Data Networks Speeds Up to 10/100 Base T and 1000 Base T. Available In LSZH Jacket Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50 Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length)
262SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173 1:2002 / IEC 60794 1/IEC 60793 2 50 class B1.3 / EN 60793 2 50: class B1.3 / ITU Recommendation G.652.D the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
263SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C 50°C ,Power Supply AC: 100 240V. Make: Digisol, Cisco, HP
264SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19 ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR 326 Core . Make: Systimax, Legrand, Panduit
265SITC of OFC Patch Cor, SM (OS2), Duplex LC SC, LC LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
266SITC of 10G LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear
267SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068 2 11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian Standard 06 Socket Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
268SITC of Rack mount Draw Type 24 port Loaded LIU available in Standard 19 ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR 326 Core . Make: Systimax, Legrand, Panduit
269P.A SystemSupply & Installation of PA Amplifire with 2 mic point & 1 Aux. point, built in MP3 player with USB reader and remote, 120 watt AC & 12 Volt DC Operation( make ahuja/equivalent as per direction of E.I.C)
270Supply of high quality ABS wall mount speaker for indoor 6 & 6 watt / 100 volt( make ahuja/equivalent as per direction of E.I.C)
271hand held Microphone with base( make ahuja/equivalent as per direction of E.I.C)
272Supplying and drawing of speaker cable Single pair, 2 core, 1.5 sqmm
273(IP CCTV System)Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low Light IR Fixed Lens Dome/Bullet Camera, 1/2.8 CMOS or better, 5MP (2592 x 1944) 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 1/30,000; Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 2.8mm, Field of View FoV H:90°, V:62°, BLC, HLC, WDR, 3DNR, White Balance Auto/Manual, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES 128/256, SSH/Telnet closed, Stream Encryption, 2 Way Audio Full Duplex Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE (802.3 af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast Aluminium Housing, Having Operating temp range 40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130 4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA/STQC compliant. Make Honeywell(Series 20), Pelco, Axis,BOSCH
274Supply & Installation of 32Channel fully Featured NVR with High decoding capability for Ultra 4K HD viewing and recording, up to 12MP(4K) resolution live view, Preview & Playback, Internal storage supports 4 HDDs expandable up to 24 TB (6 TB each). Record bit Rate (320Mbps), 2 HDMI/VGA simultaneous video, usb ports 3 (2 rear USB3.0; 1 front 5 USB2.0. RS232 1 port (for PC communications and keyboard).) The Quick Wizard and full PoE support (for up to 16 channels) make setup fast and easy. Monitor from anywhere using the mobile apps for both Apple and Android devices (smartphones, tablet computers, and laptops). EU: EN60950 1, North America UL listed to UL/CSA, 60950 1 Make ( Wbox/Honeywell )
275Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake: WD/Segate/Toshiba
276SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer
277SITC of 55 UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio 1200:1, Response Time (G to G) 8 ms, Refresh Rate. 60 Hz, Life span (hrs) 30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
278Outdoor LED Display BoardS/F & Commissioning of LED display 65 with bracket (Model 65AJ690 SAMSUNG/Commercial )
279S/F & Commissioning of CAT6 Extender for TV connectivity (4set) receiver
280HVAC System1.5 TR high wall 3 star inverter type split A.C machine (BTU/Hr 18000)with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 10 years warranty on compressor (Make:Carrier/Diakin/Hitachi/ equivalent as per direction of E.I.C)
281MS Angle stand for outer units of AC machines
282S/F of 4KVA voltage stabilizer (make V guard VEI 400 plus/ equivalent as per direction of E.I.C.)
283S/F of 20mm pvc drainage pipe line system for A.C machine
284S/F of 15A Top
285S/F of extra foam for cover of copper pipe for AC machine for split ac machine
286S/F of 3core X 2.5mm2 cord wire for A.C machine for split ac machine
287S/F of extra 1/2 & 1/4 copper cooling pipe for A.C. Machine Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56698038
AUTHORITY Government Departments
TENDER VALUE 3 Crore
LAST DATE 13-08-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Infrastructure Development At Chc. Botalama Under Ama Hospital Building In The District Of Khordha
Basic Detail
Tender No CCE-05/2026-27
Bidding Type Tender
Location
City Khordha
State Odisha
Key Dates
Publish Date 28 Jul 2026
Submission Date 13 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 3 Crore
Tender Fee 10000
EMD 3.01 Lakhs
Exemption Available
Document List
0898ac7a-02d0-422e-910a-f4d0feb2baed.html
BOQ_603570.xls
Tendernotice_1 (10).pdf
Tendernotice_2 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

0898ac7a-02d0-422e-910a-f4d0feb2baed.html

xls

BOQ_603570.xls

pdf

Tendernotice_1 (10).pdf

pdf

Tendernotice_2 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders