Tender For Non Functional Water Supply Scheme Sandhu Chatha, Block Kapurthala, District Kapurthala. (Under Head 15Th Fc)
Tender Value
26.42 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
7 days left
EMD
52859
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kapurthala → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Non Functional Water Supply Scheme Sandhu Chatha, Block Kapurthala, District Kapurthala. (Under Head 15Th Fc)
BOQ
| Sl. No. | Item Description |
| 1 | Development of tubewell |
| 2 | Development and Stabilizing of the tubwell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 3 | Capacity of Air compressor 300 cfm at 250 PSI |
| 4 | Development and Stabilizing of the tubwell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 5 | Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis) |
| 6 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) |
| 7 | Distribution network |
| 8 | Providing, Laying, fixing & jointing of P.V.C. Pipes Type-A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenhes to correct alignment and gradients, cutting, jointing and testing complete as per specifications.For more than 3 mtr street width with Mechanically Excavation including specials |
| 9 | 63mm o/d pipe of 6 kgf. / sqcm |
| 10 | 75mm o/d pipe of 6 kgf. / sqcm |
| 11 | 90mm o/d pipe of 6 kgf. / sqcm |
| 12 | 110mm o/d pipe of 6 kgf. / sqcm |
| 13 | 160mm o/d pipe of 6 kgf. / sqcm |
| 14 | Providing, Laying, fixing & jointing of P.V.C. Pipes Type-A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenhes to correct alignment and gradients, cutting, jointing and testing complete as per specifications.For Less than 3 mtr street width Manual Excavation including specials |
| 15 | 63mm o/d pipe of 6 kgf. / sqcm |
| 16 | 75mm o/d pipe of 6 kgf. / sqcm |
| 17 | 90mm o/d pipe of 6 kgf. / sqcm |
| 18 | Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position |
| 19 | 63mm o/d pipe of 6 kgf. / sqcm |
| 20 | 90mm o/d pipe of 6 kgf. / sqcm |
| 21 | Dismantling of interlock tile 80mm thick cement concrete interlocking paver block including Refixing of interlock tile 80mm thick cement concrete interlocking paver block of M-40 grade machine made rubber moulded smooth finish by strong vibratory process or with vibro-hydraulic compaction machine and of approved size and design/ shape laid in ordinary grey color and pattern over including 40mm thick |
| 22 | 63mm o/d pipe of 6 kgf. / sqcm |
| 23 | 90mm o/d pipe of 6 kgf. / sqcm |
| 24 | Dismantling of cement concrete road and restoration in original condition |
| 25 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in- charge). |
| 26 | Class PN-1 as per ISI |
| 27 | 100mm i/d Sluice Valves flanged |
| 28 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department |
| 29 | Size 0.6 m. x 0.6 m. |
| 30 | Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. |
| 31 | Earth work upto 1.5 m. Depth |
| 32 | All classes of soil except rocky |
| 33 | Supplying and fixing of ISI Marked CI D-joint (complete with nut, bolts & rubber ring) as per IS:8794 for repair of pipe line including cutting, jointing and testing etc. but excluding cost of excavation complete. |
| 34 | 80 mm |
| 35 | 100 mm |
| 36 | Connection with existing PVC pipe including cost of tee earth work in excavation and back filling complete in all respect |
| 37 | Pumping machinery |
| 38 | Providing and fixing electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps, Kit-Kat etc., complete in all respect(For existing pumping machinery 10.00 BHP) |
| 39 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 40 | Overall size 4.0sq.mm (84/0.3mm), 3Core |
| 41 | Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete |
| 42 | C.I Double air valve (Size 40mm) |
| 43 | Repair of OHSR Capacity 25000 ltr |
| 44 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks , roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/subway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystlline slurry : 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing premeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm |
| 45 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks , roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/subway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystlline slurry : 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing premeability of concrete by more than 90% compared with controlconcrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @ 1.10 kg per sqm. |
| 46 | 12.5 mm thick cement plaster 1:2 |
| 47 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in- charge). |
| 48 | Class PN-1 as per ISI |
| 49 | 100mm i/d Sluice Valves flanged |
| 50 | Supplying, fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects. |
| 51 | Plinth Protection of 25000 ltr capacity OHSR |
| 52 | Repair of expansion Joint |
| 53 | 80mm i/d |
| 54 | 100mm i/d |
| 55 | Cleaning of OHSR |
| 56 | Repair of Rising Main |
| 57 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). |
| 58 | Class PN-1 as per ISI |
| 59 | 100mm i/d Sluice Valves flanged |
| 60 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department |
| 61 | Size 0.6 m. x 0.6 m. |
| 62 | Repair of Pump Chamber size 3.70 x 4.30 |
| 63 | Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete |
| 64 | Finishing walls with cement based water soluble paint such as snowcem, robbiacem etc. two or more coats to give an even shade |
| 65 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 66 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 67 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 68 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. |
| 69 | Glass panes 3mm or 8.44 kg per sqm upto 0.4 sqm area |
| 70 | RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: |
| 71 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 72 | Wiring fan point (With fan box) |
| 73 | Wiring light point |
| 74 | Wiring 6Amp. Plug control comprising wall socket point |
| 75 | Wiring 16/20Amp. power plug control point |
| 76 | Household water connection on PVC Pipe line |
| 77 | Providing proposed water connection to household up to wall with providing, laying, jointing, testing GI pipe lines 15mm i/d B-Class, (Above GL), Prov. & fixing MDPE pipe 15mm i/d with speicals (Below GL), including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading and testing in trenches in ground and ISI marked 15mm i/d GM furrule as per IS:2692 and 3\\" i/d clamp with C.I. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make complete in all respects. |
| 78 | Disinfection Unit |
| 79 | Disinfection Unit Providing Installing, testing & commissioning one no. Electronically actuated, Diaphragm operated, Metering System, Chemical Dosing, Chlorinator, Suitable for delivering 0.5 to 6 Litres fo Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg. cm2 and suction lift not less than 1.5 m, as per DWSS standard specifications |
| 80 | Development of water works |
| 81 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing |
| 82 | Providing and fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI makred) wire 4mm dia fencing pole size at bottom 4\\" x 4\\", size top 3\\" x 4\\", length 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respect |
| 83 | Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing |
| 84 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing |
| 85 | Construction of Cement Concrete Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing |
| 86 | Painting of MS Sign board as per standard size of DWSS as per standard Drawing |
| 87 | Credit of Old Sluice valve |
| 88 | Credit of Old Sluice valve(3 nos. for OHSR and 2 nos. for Rising main) |
| 89 | 100mm i/d Sluice Valves flanged Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender