Project Description

Tender for Purchase Of Mill Vfd Panel For 450Kw Motor , Mill Vfd Panel For 450 Kw Motor , Motor Duty Class Iv- Accordingly Vfd To Be Selected • Vfd Rating: 560 Kw (Suitable For Constant Torque) • Input Supply: 415V, 3Phase, 50 Hz • Vfd Rated Current: 1035A Minimum • Vfd Type: 6 Pulse • The Vfd Should Be Rated For Minimum 1035A At 50 Deg C Ambient Temp. And After Derating For 4 Khz Switching Frequency For Smooth Operation Of Motor At Entire Speed Range (Vfd Sizing/Derating Calculation To Be Provided To Match This Specification And Motor Overload Class) • Overload Class-Iv For Mill Application: 150% Overload For 1 Hour 200% Overload For 120 Sec Scope Of Supply • Ip-42 Floor Mount Panel, Ral 7035, Bottom Cable Entry, (Make: Rita/Bch/Eldon/Vfd Oem) • Lcd Graphical Hmi On Panel Door • Input Acb-1250A Mdo Type, 3 Phase • Multi Function Meter • External Input/Dc Choke- 3% Impedance For Harmonic Suppression • Vfd Output Filter- Lc Filter/Choke- Minimum 3% Impedance • Ac Vfd Module Withrs 485 Modbus Communication, Ai- 3 Nos, Ao- 3 Nos & Relay Output - 3 Nos. • Vfd Start/Stop/Reset Push Button On Panel Door • Vfd Speed Inc-Dec Push Button On Panel Door • Ryb/Run/Trip Indication • Control Wiring Should Be From Tin Platted Copper Cable To Avoid Corrosion. (Control Function Shall Be Suitable For Mill Application) • Local/Remote/Dcs Selector Switch (One Ai/2 Ao/ 3 Do/2 Di For Dcs Operation) • Galvanic Isolators For All 3 Analog Input & Outputs • Auxiliary Contractor- (Relays Are Not Acceptable) • Back Curved High Speed Cooling Fan With Mcb • Control Supply Transformer With Mcb • Temperature Scanner -8 Window For Mill Motor • Common Mode Filter For Reduces Motor Bearing Noise And Bearing Current, Thereby Increasing Motor Bearing Life. • Dol Starter For Motor Cooling With Mpcb • Panel Space Heater With Thermostat • Panel Light With Door Switch Lcs/Remote Station • Ip55 Enclosure • Start/Stop Push Buttom, Vfd Run/ Trip Indication) & Fwd/Rev Switch • Rpm Meter- 0 To 1500 Rpm Make: Amtech, Abb, Delta & Cg Note: Your Organization Is Responsible For The Installation, Commission And Operation Of The Drive For The Crushing Season 2026-27 , Motor Duty Class Iv- Accordingly Vfd To Be Selected • Vfd Rating: 630 Kw (Suitable For Constant Torque) • Input Supply: 415V, 3Phase, 50 Hz • Vfd Rated Current: 1190A Minimum • Vfd Type: 6 Pulse (Control= Dtc & Safety= Sto) • The Vfd Should Be Rated For Minimum 1190A At 50 Deg C Ambient Temp. And After Derating For 4 Khz Switching Frequency For Smooth Operation Of Motor At Entire Speed Range (Vfd Sizing/Derating Calculation To Be Provided To Match This Specification And Motor Overload Class) • Overload Class-Iv For Mill Application: 150% Overload For 1 Hour 200% Overload For 120 Sec Scope Of Supply • Ip-42 Floor Mount Panel, Ral 7035, Bottom Cable Entry, (Make: Rita/Bch/Eldon/Vfd Oem) • Lcd Graphical Hmi On Panel Door • Input Acb-1250A Mdo Type, 3 Phase • Multi Function Meter • External Input/Dc Choke- 3% Impedance For Harmonic Suppression • Vfd Output Filter- Lc Filter/Choke- Minimum 3% Impedance • Ac Vfd Module Withrs 485 Modbus Communication, Ai- 3 Nos, Ao- 3 Nos & Relay Output - 3 Nos. • Vfd Start/Stop/Reset Push Button On Panel Door • Vfd Speed Inc-Dec Push Button On Panel Door • Ryb/Run/Trip Indication • Control Wiring Should Be From Tin Platted Copper Cable To Avoid Corrosion. (Control Function Shall Be Suitable For Mill Application) • Local/Remote/Dcs Selector Switch (One Ai/2 Ao/ 3 Do/2 Di For Dcs Operation) • Galvanic Isolators For All 3 Analog Input & Outputs • Auxiliary Contractor- (Relays Are Not Acceptable) • Back Curved High Speed Cooling Fan With Mcb • Control Supply Transformer With Mcb • Temperature Scanner -8 Window For Mill Motor • Common Mode Filter For Reduces Motor Bearing Noise And Bearing Current, Thereby Increasing Motor Bearing Life. • Dol Starter For Motor Cooling With Mpcb • Panel Space Heater With Thermostat • Panel Light With Door Switch Lcs/Remote Station • Ip55 Enclosure • Start/Stop Push Buttom, Vfd Run/ Trip Indication) & Fwd/Rev Switch • Rpm Meter- 0 To 1500 Rpm Make: Amtech, Abb, Delta & Cg Note: Your Organization Is Responsible For The Installation, Commission And Operation Of The Drive For The Crushing Season 2026-27 , Motor Duty Class Iv-Accordingly Vfd To Be Selected • Vfd Rating: 630Kw (Suitable For Constant Torque) • Input Supply: 415V, 3 Phase, 50 Hz • Vfd Rated Current: 1190A Minimum • Vfd Type: 6 Pulse • The Vfd Should Be Rated For Minimum 1190A At 50 Deg C Ambient Temp. And After Derating For 4 Khz Switching Frequency For Smooth Operation Of Motor At Entire Speed Rang ( Vfd Sizing/Derating Calculation To Be Provided To Match This Specification And Motor Overload Class) • Overload Class-Iv For Mill Application: • 150% Overload For 1 Hour • 200% Overload For 120 Sec (Control= Dtc & Safety= Sto) Make: Amtech, Abb, Delta & Cg , Motor Duty Class Iv-Accordingly Vfd To Be Selected • Vfd Rating: 560Kw (Suitable For Constant Torque) • Input Supply: 415V, 3 Phase, 50 Hz • Vfd Rated Current: 1035A Minimum • Vfd Type: 6 Pulse • The Vfd Should Be Rated For Minimum 1035A At 50 Deg C Ambient Temp. And After Derating For 4 Khz Switching Frequency For Smooth Operation Of Motor At Entire Speed Rang ( Vfd Sizing/Derating Calculation To Be Provided To Match This Specification And Motor Overload Class) • Overload Class-Iv For Mill Application: • 150% Overload For 1 Hour • 200% Overload For 120 Sec (Control= Dtc & Safety= Sto) Make: Amtech, Abb, Delta & Cg

BOQ

Name of Work:- PURCHASE OF MILL VFD PANEL FOR 450KW MOTOR
Sl. No. Item Description
1MILL VFD PANEL FOR 450 KW MOTOR
2Motor Duty Class IV- Accordingly VFD to be selected• VFD Rating: 560 kw (Suitable for Constant Torque)• Input Supply: 415V, 3Phase, 50 Hz• VFD Rated Current: 1035A Minimum• VFD Type: 6 Pulse• The VFD should be rated for minimum 1035A at 50 Deg C Ambient Temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed range (VFD sizing/Derating Calculation to be provided to match this specification and motor overload class)• Overload class-IV for Mill application: 150% Overload for 1 Hour200% Overload for 120 SecScope of Supply• IP-42 floor mount panel, RAL 7035, bottom cable entry, (Make: Rita/BCH/Eldon/VFD OEM)• LCD Graphical HMI on Panel Door• Input ACB-1250A MDO Type, 3 Phase• Multi Function Meter• External input/DC Choke- 3% impedance for Harmonic Suppression• VFD Output Filter- LC Filter/Choke- Minimum 3% Impedance• AC VFD Module withRS 485 Modbus Communication, AI- 3 Nos, AO- 3 Nos & Relay Output – 3 Nos.• VFD Start/Stop/Reset Push button on panel door• VFD Speed inc-Dec push button on panel door• RYB/Run/Trip indication• Control wiring should be from Tin Platted Copper cable to avoid corrosion. (Control function shall be suitable for Mill application)• Local/Remote/DCS Selector switch (One AI/2 AO/ 3 DO/2 DI for DCS operation)• Galvanic Isolators for all 3 Analog input & Outputs• Auxiliary contractor- (Relays are not acceptable)• Back Curved high speed Cooling fan with MCB• Control supply transformer with MCB• Temperature Scanner -8 Window for Mill Motor• Common mode Filter for reduces motor bearing noise and bearing current, thereby increasing motor bearing life.• DOL Starter for Motor cooling with MPCB• Panel space heater with thermostat• Panel light with door switchLCS/Remote Station• IP55 Enclosure• Start/Stop Push buttom, VFD Run/ Trip Indication) & FWD/REV Switch• RPM Meter- 0 to 1500 RPMMake: Amtech, ABB, Delta & CGNote: Your Organization is responsible for the installation, commission and operation of the drive for the crushing season 2026-27
3Motor Duty Class IV- Accordingly VFD to be selected• VFD Rating: 630 kw (Suitable for Constant Torque)• Input Supply: 415V, 3Phase, 50 Hz• VFD Rated Current: 1190A Minimum• VFD Type: 6 Pulse (Control= DTC & safety= STO)• The VFD should be rated for minimum 1190A at 50 Deg C Ambient Temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed range (VFD sizing/Derating Calculation to be provided to match this specification and motor overload class)• Overload class-IV for Mill application: 150% Overload for 1 Hour200% Overload for 120 SecScope of Supply• IP-42 floor mount panel, RAL 7035, bottom cable entry, (Make: Rita/BCH/Eldon/VFD OEM)• LCD Graphical HMI on Panel Door• Input ACB-1250A MDO Type, 3 Phase• Multi Function Meter• External input/DC Choke- 3% impedance for Harmonic Suppression• VFD Output Filter- LC Filter/Choke- Minimum 3% Impedance• AC VFD Module withRS 485 Modbus Communication, AI- 3 Nos, AO- 3 Nos & Relay Output – 3 Nos.• VFD Start/Stop/Reset Push button on panel door• VFD Speed inc-Dec push button on panel door• RYB/Run/Trip indication• Control wiring should be from Tin Platted Copper cable to avoid corrosion. (Control function shall be suitable for Mill application)• Local/Remote/DCS Selector switch (One AI/2 AO/ 3 DO/2 DI for DCS operation)• Galvanic Isolators for all 3 Analog input & Outputs• Auxiliary contractor- (Relays are not acceptable)• Back Curved high speed Cooling fan with MCB• Control supply transformer with MCB• Temperature Scanner -8 Window for Mill Motor• Common mode Filter for reduces motor bearing noise and bearing current, thereby increasing motor bearing life.• DOL Starter for Motor cooling with MPCB• Panel space heater with thermostat• Panel light with door switchLCS/Remote Station• IP55 Enclosure• Start/Stop Push buttom, VFD Run/ Trip Indication) & FWD/REV Switch• RPM Meter- 0 to 1500 RPMMake: Amtech, ABB, Delta & CGNote: Your Organization is responsible for the installation, commission and operation of the drive for the crushing season 2026-27
4Motor Duty Class IV-Accordingly VFD to be selected• VFD Rating: 630kw (Suitable for Constant Torque)• Input Supply: 415V, 3 Phase, 50 Hz• VFD Rated Current: 1190A Minimum• VFD Type: 6 Pulse• The VFD Should be rated for minimum 1190A at 50 Deg C Ambient Temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed rang ( VFD sizing/Derating Calculation to be provided to match this specification and motor overload Class)• Overload Class-IV for Mill Application:• 150% Overload for 1 Hour• 200% Overload for 120 Sec(Control= DTC & Safety= STO) Make: Amtech, ABB, Delta & CG
5Motor Duty Class IV-Accordingly VFD to be selected• VFD Rating: 560kw (Suitable for Constant Torque)• Input Supply: 415V, 3 Phase, 50 Hz• VFD Rated Current: 1035A Minimum• VFD Type: 6 Pulse• The VFD Should be rated for minimum 1035A at 50 Deg C Ambient Temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed rang ( VFD sizing/Derating Calculation to be provided to match this specification and motor overload Class)• Overload Class-IV for Mill Application:• 150% Overload for 1 Hour• 200% Overload for 120 Sec (Control= DTC & Safety= STO) Make: Amtech, ABB, Delta & CG Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56695812
AUTHORITY Cooperative
TENDER VALUE 8 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Sugar Federation
Work Description Tender for Purchase Of Mill Vfd Panel For 450Kw Motor , Mill Vfd Panel For 450 Kw Motor , Motor Duty Class Iv- Accordingly Vfd To Be Selected • Vfd Rating: 560 Kw (Suitable For Constant Torque) • Input Supply: 415V, 3Phase, 50 Hz • Vfd Rated Current: 1035A Minimum • Vfd Type: 6 Pulse • The Vfd Should Be Rated For Minimum 1035A At 50 Deg C Ambient Temp. And After Derating For 4 Khz Switching Frequency For Smooth Operation Of Motor At Entire Speed Range (Vfd Sizing/Derating Calculation To Be Provided To Match This Specification And Motor Overload Class) • Overload Class-Iv For Mill Application: 150% Overload For 1 Hour 200% Overload For 120 Sec Scope Of Supply • Ip-42 Floor Mount Panel, Ral 7035, Bottom Cable Entry, (Make: Rita/Bch/Eldon/Vfd Oem) • Lcd Graphical Hmi On Panel Door • Input Acb-1250A Mdo Type, 3 Phase • Multi Function Meter • External Input/Dc Choke- 3% Impedance For Harmonic Suppression • Vfd Output Filter- Lc Filter/Choke- Minimum 3% Impedance • Ac Vfd Module Withrs 485 Modbus Communication, Ai- 3 Nos, Ao- 3 Nos & Relay Output - 3 Nos. • Vfd Start/Stop/Reset Push Button On Panel Door • Vfd Speed Inc-Dec Push Button On Panel Door • Ryb/Run/Trip Indication • Control Wiring Should Be From Tin Platted Copper Cable To Avoid Corrosion. (Control Function Shall Be Suitable For Mill Application) • Local/Remote/Dcs Selector Switch (One Ai/2 Ao/ 3 Do/2 Di For Dcs Operation) • Galvanic Isolators For All 3 Analog Input & Outputs • Auxiliary Contractor- (Relays Are Not Acceptable) • Back Curved High Speed Cooling Fan With Mcb • Control Supply Transformer With Mcb • Temperature Scanner -8 Window For Mill Motor • Common Mode Filter For Reduces Motor Bearing Noise And Bearing Current, Thereby Increasing Motor Bearing Life. • Dol Starter For Motor Cooling With Mpcb • Panel Space Heater With Thermostat • Panel Light With Door Switch Lcs/Remote Station • Ip55 Enclosure • Start/Stop Push Buttom, Vfd Run/ Trip Indication) & Fwd/Rev Switch • Rpm Meter- 0 To 1500 Rpm Make: Amtech, Abb, Delta & Cg Note: Your Organization Is Responsible For The Installation, Commission And Operation Of The Drive For The Crushing Season 2026-27 , Motor Duty Class Iv- Accordingly Vfd To Be Selected • Vfd Rating: 630 Kw (Suitable For Constant Torque) • Input Supply: 415V, 3Phase, 50 Hz • Vfd Rated Current: 1190A Minimum • Vfd Type: 6 Pulse (Control= Dtc & Safety= Sto) • The Vfd Should Be Rated For Minimum 1190A At 50 Deg C Ambient Temp. And After Derating For 4 Khz Switching Frequency For Smooth Operation Of Motor At Entire Speed Range (Vfd Sizing/Derating Calculation To Be Provided To Match This Specification And Motor Overload Class) • Overload Class-Iv For Mill Application: 150% Overload For 1 Hour 200% Overload For 120 Sec Scope Of Supply • Ip-42 Floor Mount Panel, Ral 7035, Bottom Cable Entry, (Make: Rita/Bch/Eldon/Vfd Oem) • Lcd Graphical Hmi On Panel Door • Input Acb-1250A Mdo Type, 3 Phase • Multi Function Meter • External Input/Dc Choke- 3% Impedance For Harmonic Suppression • Vfd Output Filter- Lc Filter/Choke- Minimum 3% Impedance • Ac Vfd Module Withrs 485 Modbus Communication, Ai- 3 Nos, Ao- 3 Nos & Relay Output - 3 Nos. • Vfd Start/Stop/Reset Push Button On Panel Door • Vfd Speed Inc-Dec Push Button On Panel Door • Ryb/Run/Trip Indication • Control Wiring Should Be From Tin Platted Copper Cable To Avoid Corrosion. (Control Function Shall Be Suitable For Mill Application) • Local/Remote/Dcs Selector Switch (One Ai/2 Ao/ 3 Do/2 Di For Dcs Operation) • Galvanic Isolators For All 3 Analog Input & Outputs • Auxiliary Contractor- (Relays Are Not Acceptable) • Back Curved High Speed Cooling Fan With Mcb • Control Supply Transformer With Mcb • Temperature Scanner -8 Window For Mill Motor • Common Mode Filter For Reduces Motor Bearing Noise And Bearing Current, Thereby Increasing Motor Bearing Life. • Dol Starter For Motor Cooling With Mpcb • Panel Space Heater With Thermostat • Panel Light With Door Switch Lcs/Remote Station • Ip55 Enclosure • Start/Stop Push Buttom, Vfd Run/ Trip Indication) & Fwd/Rev Switch • Rpm Meter- 0 To 1500 Rpm Make: Amtech, Abb, Delta & Cg Note: Your Organization Is Responsible For The Installation, Commission And Operation Of The Drive For The Crushing Season 2026-27 , Motor Duty Class Iv-Accordingly Vfd To Be Selected • Vfd Rating: 630Kw (Suitable For Constant Torque) • Input Supply: 415V, 3 Phase, 50 Hz • Vfd Rated Current: 1190A Minimum • Vfd Type: 6 Pulse • The Vfd Should Be Rated For Minimum 1190A At 50 Deg C Ambient Temp. And After Derating For 4 Khz Switching Frequency For Smooth Operation Of Motor At Entire Speed Rang ( Vfd Sizing/Derating Calculation To Be Provided To Match This Specification And Motor Overload Class) • Overload Class-Iv For Mill Application: • 150% Overload For 1 Hour • 200% Overload For 120 Sec (Control= Dtc & Safety= Sto) Make: Amtech, Abb, Delta & Cg , Motor Duty Class Iv-Accordingly Vfd To Be Selected • Vfd Rating: 560Kw (Suitable For Constant Torque) • Input Supply: 415V, 3 Phase, 50 Hz • Vfd Rated Current: 1035A Minimum • Vfd Type: 6 Pulse • The Vfd Should Be Rated For Minimum 1035A At 50 Deg C Ambient Temp. And After Derating For 4 Khz Switching Frequency For Smooth Operation Of Motor At Entire Speed Rang ( Vfd Sizing/Derating Calculation To Be Provided To Match This Specification And Motor Overload Class) • Overload Class-Iv For Mill Application: • 150% Overload For 1 Hour • 200% Overload For 120 Sec (Control= Dtc & Safety= Sto) Make: Amtech, Abb, Delta & Cg
Basic Detail
Tender No FAZILKA/PURCHASE/26-27/4
Bidding Type Tender
Location
City Fazilka
State Punjab
Key Dates
Publish Date 28 Jul 2026
Submission Date 17 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 8 Lakhs
Tender Fee 100
EMD Ref. Documents
Exemption Not Available
Document List
505625eb-4459-4f28-8098-20cb84933319.html
BOQ_351239.xls
Tendernotice_1 (10).pdf
VFDBID.pdf
VFDNIT.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

505625eb-4459-4f28-8098-20cb84933319.html

xls

BOQ_351239.xls

pdf

Tendernotice_1 (10).pdf

pdf

VFDBID.pdf

pdf

VFDNIT.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders